Vulnerabilites related to siemens - 7kg9501-0aa01-0aa1_firmware
CVE-2021-44165 (GCVE-0-2021-44165)
Vulnerability from cvelistv5
Published
2021-12-14 12:06
Modified
2024-08-04 04:17
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens | POWER METER SICAM Q100 |
Version: All versions < V2.41 |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:17:24.538Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.41" } ] }, { "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.41" } ] }, { "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.41" } ] }, { "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.41" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-14T12:06:52", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-44165", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "POWER METER SICAM Q100", "version": { "version_data": [ { "version_value": "All versions \u003c V2.41" } ] } }, { "product_name": "POWER METER SICAM Q100", "version": { "version_data": [ { "version_value": "All versions \u003c V2.41" } ] } }, { "product_name": "POWER METER SICAM Q100", "version": { "version_data": [ { "version_value": "All versions \u003c V2.41" } ] } }, { "product_name": "POWER METER SICAM Q100", "version": { "version_data": [ { "version_value": "All versions \u003c V2.41" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-121: Stack-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-44165", "datePublished": "2021-12-14T12:06:52", "dateReserved": "2021-11-23T00:00:00", "dateUpdated": "2024-08-04T04:17:24.538Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2021-12-14 12:15
Modified
2024-11-21 06:30
Severity ?
Summary
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:7kg9501-0aa01-2aa1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96EDF0C8-91BF-48C2-8FDC-C3AFBC8878D0", "versionEndExcluding": "2.41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:7kg9501-0aa01-2aa1:-:*:*:*:*:*:*:*", "matchCriteriaId": "275E9296-AACA-4F3B-B8FA-D52A59E729DE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:7kg9501-0aa31-0aa1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B100E1D3-4D10-4066-9067-799076DD6643", "versionEndExcluding": "2.41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:7kg9501-0aa31-0aa1:-:*:*:*:*:*:*:*", "matchCriteriaId": "B09F87C0-1A7D-43F6-A02F-D808C880FF74", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:7kg9501-0aa31-2aa1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27616240-C04A-4F45-8A6D-B8044242CF5C", "versionEndExcluding": "2.41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:7kg9501-0aa31-2aa1:-:*:*:*:*:*:*:*", "matchCriteriaId": "DC260D4F-53BD-433C-AE8F-FA2FA47BC921", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:7kg9501-0aa01-0aa1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD0414B9-4EF2-4486-A2BA-926CD0A1D23A", "versionEndExcluding": "2.41", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:7kg9501-0aa01-0aa1:-:*:*:*:*:*:*:*", "matchCriteriaId": "632E89F3-80E7-4E2F-A3D3-0A6183F4A444", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en POWER METER SICAM Q100 (Todas las versiones anteriores a V2.41), POWER METER SICAM Q100 (Todas las versiones anteriores a V2.41), POWER METER SICAM Q100 (Todas las versiones anteriores a V2.41), POWER METER SICAM Q100 (Todas las versiones anteriores a V2.41). El firmware afectado contiene una vulnerabilidad de desbordamiento de b\u00fafer en la aplicaci\u00f3n web que podr\u00eda permitir a un atacante remoto con privilegios de ingeniero o administrador realizar potencialmente una ejecuci\u00f3n de c\u00f3digo remota" } ], "id": "CVE-2021-44165", "lastModified": "2024-11-21T06:30:28.937", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-14T12:15:10.923", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }