CVE-2020-8484 (GCVE-0-2020-8484)
Vulnerability from cvelistv5
Published
2020-04-29 01:58
Modified
2024-08-04 10:03
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-264 - Permissions, Privileges, and Access Controls
Summary
Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash.
References
► | URL | Tags |
---|---|---|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
ABB | 800xA for DCI |
Version: all versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:03:45.932Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "800xA for DCI", "vendor": "ABB", "versions": [ { "status": "affected", "version": "all versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-264", "description": "CWE-264 Permissions, Privileges, and Access Controls", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-29T01:58:57", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "source": { "discovery": "UNKNOWN" }, "title": "ABB System 800xA Inter process communication vulnerability - 800xA for DCI", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@ch.abb.com", "ID": "CVE-2020-8484", "STATE": "PUBLIC", "TITLE": "ABB System 800xA Inter process communication vulnerability - 800xA for DCI" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "800xA for DCI", "version": { "version_data": [ { "version_affected": "undefined", "version_value": "all versions" } ] } } ] }, "vendor_name": "ABB" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA for DCI (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-264 Permissions, Privileges, and Access Controls" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "CONFIRM", "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2020-8484", "datePublished": "2020-04-29T01:58:57", "dateReserved": "2020-01-30T00:00:00", "dateUpdated": "2024-08-04T10:03:45.932Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }