Vulnerabilites related to ABB - ABB PB610 Panel Builder 600
CVE-2019-18994 (GCVE-0-2019-18994)
Vulnerability from cvelistv5
Published
2019-12-18 20:20
Modified
2024-08-05 02:02
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-20 - Improper Input Validation
Summary
Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service.
References
► | URL | Tags |
---|---|---|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
ABB | ABB PB610 Panel Builder 600 |
Version: unspecified < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:02:39.901Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://search.abb.com/library/Download.aspx?DocumentID=3ADR010466\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "ABB PB610 Panel Builder 600", "vendor": "ABB", "versions": [ { "lessThanOrEqual": "2.8.0.424", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "NSFOCUS for providing vulnerability details and proof of concept." } ], "descriptions": [ { "lang": "en", "value": "Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 3.9, "baseSeverity": "LOW", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-12-18T20:20:57", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://search.abb.com/library/Download.aspx?DocumentID=3ADR010466\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "source": { "advisory": "3ADR010466", "defect": [ "ABBVU-RAMF-1908001" ], "discovery": "UNKNOWN" }, "title": "ABB PB610 HMIStudio crashes after launching an empty *.JPR application file", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@ch.abb.com", "ID": "CVE-2019-18994", "STATE": "PUBLIC", "TITLE": "ABB PB610 HMIStudio crashes after launching an empty *.JPR application file" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "ABB PB610 Panel Builder 600", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "2.8.0.424" } ] } } ] }, "vendor_name": "ABB" } ] } }, "credit": [ { "lang": "eng", "value": "NSFOCUS for providing vulnerability details and proof of concept." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 3.9, "baseSeverity": "LOW", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "http://search.abb.com/library/Download.aspx?DocumentID=3ADR010466\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "MISC", "url": "http://search.abb.com/library/Download.aspx?DocumentID=3ADR010466\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "source": { "advisory": "3ADR010466", "defect": [ "ABBVU-RAMF-1908001" ], "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2019-18994", "datePublished": "2019-12-18T20:20:57", "dateReserved": "2019-11-15T00:00:00", "dateUpdated": "2024-08-05T02:02:39.901Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }