Vulnerabilites related to Tenda - AC500
CVE-2024-10280 (GCVE-0-2024-10280)
Vulnerability from cvelistv5
Published
2024-10-23 13:31
Modified
2024-10-23 17:41
Severity ?
7.1 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-476 - NULL Pointer Dereference
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.09" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.48.23" }, { "status": "affected", "version": "16.03.48.19" }, { "status": "affected", "version": "16.03.48.20" }, { "status": "affected", "version": "16.03.48.13" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.42" }, { "status": "affected", "version": "15.03.05.19\\(6318_\\)" }, { "status": "affected", "version": "15.03.05.14" }, { "status": "affected", "version": "15.03.2.13" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac18_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.05" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac18_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.19\\(6318\\)" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.1.9\\(1307\\)" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.16" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10u_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.48" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10u_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.49" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.19" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-10280", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-10-23T17:28:19.760214Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-23T17:41:57.370Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC6", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC9", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC10", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC10U", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC18", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC500", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC1206", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "minipython (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.8, "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-23T13:31:07.315Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.281555" }, { "name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.281555" }, { "name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.426417" }, { "tags": [ "exploit" ], "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2024-10-23T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-10-23T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-10-23T08:07:55.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-10280", "datePublished": "2024-10-23T13:31:07.315Z", "dateReserved": "2024-10-23T06:02:03.363Z", "dateUpdated": "2024-10-23T17:41:57.370Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-7586 (GCVE-0-2025-7586)
Vulnerability from cvelistv5
Published
2025-07-14 08:02
Modified
2025-07-14 15:22
Severity ?
VLAI Severity ?
EPSS score ?
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation of the argument radio_2g_1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-7586", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-07-14T15:09:40.026670Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-07-14T15:22:29.586Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC500", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.1.9(1307)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "panda_0x1 (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation of the argument radio_2g_1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "In Tenda AC500 2.0.1.9(1307) wurde eine kritische Schwachstelle ausgemacht. Es geht um die Funktion formSetAPCfg der Datei /goform/setWtpData. Mit der Manipulation des Arguments radio_2g_1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-14T08:02:06.975Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-316285 | Tenda AC500 setWtpData formSetAPCfg stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.316285" }, { "name": "VDB-316285 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.316285" }, { "name": "Submit #615169 | Tenda AC500 V2.0.1.9(1307) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.615169" }, { "tags": [ "related" ], "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ac500/formSetAPCfg.md" }, { "tags": [ "exploit" ], "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ac500/formSetAPCfg.md#poc" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-07-13T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-07-13T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-07-13T15:03:11.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC500 setWtpData formSetAPCfg stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-7586", "datePublished": "2025-07-14T08:02:06.975Z", "dateReserved": "2025-07-13T12:58:01.563Z", "dateUpdated": "2025-07-14T15:22:29.586Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-32316 (GCVE-0-2024-32316)
Vulnerability from cvelistv5
Published
2024-04-17 00:00
Modified
2024-08-16 15:25
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T02:06:44.162Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_list1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.1.9\\(1307\\)" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-32316", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-16T15:24:34.642778Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-16T15:25:33.032Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-17T15:58:22.555706", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_list1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-32316", "datePublished": "2024-04-17T00:00:00", "dateReserved": "2024-04-12T00:00:00", "dateUpdated": "2024-08-16T15:25:33.032Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-32318 (GCVE-0-2024-32318)
Vulnerability from cvelistv5
Published
2024-04-17 00:00
Modified
2024-08-02 02:06
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.1.9\\(1307\\)" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-32318", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-22T15:40:37.482036Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:50:36.685Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T02:06:44.050Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromSetVlanInfo_vlan.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-17T15:56:52.322308", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromSetVlanInfo_vlan.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-32318", "datePublished": "2024-04-17T00:00:00", "dateReserved": "2024-04-12T00:00:00", "dateUpdated": "2024-08-02T02:06:44.050Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25234 (GCVE-0-2023-25234)
Vulnerability from cvelistv5
Published
2023-02-27 00:00
Modified
2025-03-10 17:41
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInterface.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:36.264Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113_1" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-25234", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-10T17:40:36.185091Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-10T17:41:03.939Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInterface." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-27T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113_1" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25234", "datePublished": "2023-02-27T00:00:00.000Z", "dateReserved": "2023-02-06T00:00:00.000Z", "dateUpdated": "2025-03-10T17:41:03.939Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-3908 (GCVE-0-2024-3908)
Vulnerability from cvelistv5
Published
2024-04-17 11:31
Modified
2024-08-01 20:26
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
VLAI Severity ?
EPSS score ?
CWE
- CWE-77 - Command Injection
Summary
A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261144. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-3908", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-04-29T19:08:58.012071Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:31:17.567Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:26:57.152Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-261144 | Tenda AC500 WriteFacMac formWriteFacMac command injection", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.261144" }, { "name": "VDB-261144 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.261144" }, { "name": "Submit #313803 | Tenda AC500 V2.0.1.9(1307) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.313803" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formWriteFacMac.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC500", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.1.9(1307)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261144. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda AC500 2.0.1.9(1307) entdeckt. Betroffen hiervon ist die Funktion formWriteFacMac der Datei /goform/WriteFacMac. Durch Manipulation des Arguments mac mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.5, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77 Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-17T11:31:04.525Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-261144 | Tenda AC500 WriteFacMac formWriteFacMac command injection", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.261144" }, { "name": "VDB-261144 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.261144" }, { "name": "Submit #313803 | Tenda AC500 V2.0.1.9(1307) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.313803" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formWriteFacMac.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-17T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-17T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-17T07:53:05.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC500 WriteFacMac formWriteFacMac command injection" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3908", "datePublished": "2024-04-17T11:31:04.525Z", "dateReserved": "2024-04-17T05:42:48.926Z", "dateUpdated": "2024-08-01T20:26:57.152Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-3905 (GCVE-0-2024-3905)
Vulnerability from cvelistv5
Published
2024-04-17 10:31
Modified
2024-08-01 20:26
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-3905", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-04-29T19:10:05.982005Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:31:03.283Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:26:57.134Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-261141 | Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.261141" }, { "name": "VDB-261141 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.261141" }, { "name": "Submit #313790 | Tenda AC500 V2.0.1.9(1307) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.313790" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/R7WebsSecurityHandler.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC500", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.1.9(1307)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_mie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda AC500 2.0.1.9(1307) ausgemacht. Sie wurde als kritisch eingestuft. Hiervon betroffen ist die Funktion R7WebsSecurityHandler der Datei /goform/execCommand. Dank Manipulation des Arguments password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-17T10:31:04.297Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-261141 | Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.261141" }, { "name": "VDB-261141 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.261141" }, { "name": "Submit #313790 | Tenda AC500 V2.0.1.9(1307) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.313790" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/R7WebsSecurityHandler.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-17T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-17T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-17T07:52:41.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC500 execCommand R7WebsSecurityHandler stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3905", "datePublished": "2024-04-17T10:31:04.297Z", "dateReserved": "2024-04-17T05:42:30.657Z", "dateUpdated": "2024-08-01T20:26:57.134Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-3910 (GCVE-0-2024-3910)
Vulnerability from cvelistv5
Published
2024-04-17 12:00
Modified
2024-08-01 20:26
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500", "vendor": "tenda", "versions": [ { "status": "affected", "version": "-" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3910", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-04-23T19:14:35.355698Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:33:24.339Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:26:57.124Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-261146 | Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.261146" }, { "name": "VDB-261146 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.261146" }, { "name": "Submit #313805 | Tenda AC500 V2.0.1.9(1307) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.313805" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_page.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC500", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.1.9(1307)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda AC500 2.0.1.9(1307) entdeckt. Es geht hierbei um die Funktion fromDhcpListClient der Datei /goform/DhcpListClient. Mittels Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-17T12:00:05.651Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-261146 | Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.261146" }, { "name": "VDB-261146 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.261146" }, { "name": "Submit #313805 | Tenda AC500 V2.0.1.9(1307) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.313805" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_page.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-17T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-17T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-17T07:53:13.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC500 DhcpListClient fromDhcpListClient stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3910", "datePublished": "2024-04-17T12:00:05.651Z", "dateReserved": "2024-04-17T05:42:57.816Z", "dateUpdated": "2024-08-01T20:26:57.124Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-32314 (GCVE-0-2024-32314)
Vulnerability from cvelistv5
Published
2024-04-17 00:00
Modified
2024-08-02 02:06
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.1.9" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 3.8, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-32314", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-22T21:39:22.420262Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:50:24.648Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T02:06:44.064Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexecommand_cmdi.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-17T16:01:02.074897", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexecommand_cmdi.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-32314", "datePublished": "2024-04-17T00:00:00", "dateReserved": "2024-04-12T00:00:00", "dateUpdated": "2024-08-02T02:06:44.064Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-32320 (GCVE-0-2024-32320)
Vulnerability from cvelistv5
Published
2024-04-17 00:00
Modified
2024-08-02 02:06
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v2.0.1.9(1307)" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-32320", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-04-22T18:11:57.818708Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:51:17.429Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T02:06:44.086Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetTimeZone.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-17T15:49:54.235216", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetTimeZone.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-32320", "datePublished": "2024-04-17T00:00:00", "dateReserved": "2024-04-12T00:00:00", "dateUpdated": "2024-08-02T02:06:44.086Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-46060 (GCVE-0-2023-46060)
Vulnerability from cvelistv5
Published
2024-04-17 00:00
Modified
2025-03-27 19:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A Buffer Overflow vulnerability in Tenda AC500 v.2.0.1.9 allows a remote attacker to cause a denial of service via the port parameter at the goform/setVlanInfo component.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.1.9" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-46060", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-04-25T18:08:38.809495Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-27T19:07:07.437Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T20:37:39.278Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/Tenda/ac500/fromSetVlanInfo/1.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A Buffer Overflow vulnerability in Tenda AC500 v.2.0.1.9 allows a remote attacker to cause a denial of service via the port parameter at the goform/setVlanInfo component." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-17T15:53:58.862Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/Tenda/ac500/fromSetVlanInfo/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-46060", "datePublished": "2024-04-17T00:00:00.000Z", "dateReserved": "2023-10-16T00:00:00.000Z", "dateUpdated": "2025-03-27T19:07:07.437Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-3906 (GCVE-0-2024-3906)
Vulnerability from cvelistv5
Published
2024-04-17 10:31
Modified
2024-08-01 20:26
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.1.9(1307)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3906", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-04-23T18:24:41.411561Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:33:20.174Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:26:57.104Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-261142 | Tenda AC500 QuickIndex formQuickIndex stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.261142" }, { "name": "VDB-261142 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.261142" }, { "name": "Submit #313801 | Tenda AC500 V2.0.1.9(1307) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.313801" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formQuickIndex.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC500", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.1.9(1307)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC500 2.0.1.9(1307) wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion formQuickIndex der Datei /goform/QuickIndex. Mit der Manipulation des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-17T10:31:05.641Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-261142 | Tenda AC500 QuickIndex formQuickIndex stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.261142" }, { "name": "VDB-261142 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.261142" }, { "name": "Submit #313801 | Tenda AC500 V2.0.1.9(1307) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.313801" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formQuickIndex.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-17T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-17T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-17T07:52:55.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC500 QuickIndex formQuickIndex stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3906", "datePublished": "2024-04-17T10:31:05.641Z", "dateReserved": "2024-04-17T05:42:39.118Z", "dateUpdated": "2024-08-01T20:26:57.104Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-3909 (GCVE-0-2024-3909)
Vulnerability from cvelistv5
Published
2024-04-17 11:31
Modified
2024-08-01 20:26
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.1.9\\(1307\\)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3909", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-04-22T15:10:58.576153Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:31:11.551Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:26:57.136Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-261145 | Tenda AC500 execCommand formexeCommand stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.261145" }, { "name": "VDB-261145 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.261145" }, { "name": "Submit #313804 | Tenda AC500 V2.0.1.9(1307) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.313804" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC500", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.1.9(1307)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC500 2.0.1.9(1307) wurde eine kritische Schwachstelle entdeckt. Es geht um die Funktion formexeCommand der Datei /goform/execCommand. Mittels dem Manipulieren des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-17T11:31:05.865Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-261145 | Tenda AC500 execCommand formexeCommand stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.261145" }, { "name": "VDB-261145 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.261145" }, { "name": "Submit #313804 | Tenda AC500 V2.0.1.9(1307) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.313804" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-17T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-17T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-17T07:53:08.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC500 execCommand formexeCommand stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3909", "datePublished": "2024-04-17T11:31:05.865Z", "dateReserved": "2024-04-17T05:42:53.219Z", "dateUpdated": "2024-08-01T20:26:57.136Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25233 (GCVE-0-2023-25233)
Vulnerability from cvelistv5
Published
2023-02-27 00:00
Modified
2025-03-10 13:53
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInterface.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:36.252Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-25233", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-10T13:51:50.684355Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-10T13:53:20.215Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInterface." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-27T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25233", "datePublished": "2023-02-27T00:00:00.000Z", "dateReserved": "2023-02-06T00:00:00.000Z", "dateUpdated": "2025-03-10T13:53:20.215Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-3907 (GCVE-0-2024-3907)
Vulnerability from cvelistv5
Published
2024-04-17 11:00
Modified
2024-08-01 20:26
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500", "vendor": "tenda", "versions": [ { "status": "affected", "version": "-2.0.1.9(1307)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3907", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-04-22T19:50:29.075942Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:32:54.186Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:26:57.130Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-261143 | Tenda AC500 setcfm formSetCfm stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.261143" }, { "name": "VDB-261143 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.261143" }, { "name": "Submit #313802 | Tenda AC500 V2.0.1.9(1307) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.313802" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetCfm.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC500", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "2.0.1.9(1307)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC500 2.0.1.9(1307) ausgemacht. Sie wurde als kritisch eingestuft. Betroffen davon ist die Funktion formSetCfm der Datei /goform/setcfm. Durch die Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-17T11:00:06.424Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-261143 | Tenda AC500 setcfm formSetCfm stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.261143" }, { "name": "VDB-261143 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.261143" }, { "name": "Submit #313802 | Tenda AC500 V2.0.1.9(1307) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.313802" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetCfm.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-17T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-17T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-17T07:53:02.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC500 setcfm formSetCfm stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3907", "datePublished": "2024-04-17T11:00:06.424Z", "dateReserved": "2024-04-17T05:42:46.647Z", "dateUpdated": "2024-08-01T20:26:57.130Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-25235 (GCVE-0-2023-25235)
Vulnerability from cvelistv5
Published
2023-02-27 00:00
Modified
2025-03-10 17:42
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:36.284Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113_2" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-25235", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-10T17:41:23.130135Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-10T17:42:05.488Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-27T00:00:00.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113_2" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25235", "datePublished": "2023-02-27T00:00:00.000Z", "dateReserved": "2023-02-06T00:00:00.000Z", "dateUpdated": "2025-03-10T17:42:05.488Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2023-02-27 16:15
Modified
2025-03-10 18:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInterface.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113_1 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113_1 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInterface." } ], "id": "CVE-2023-25234", "lastModified": "2025-03-10T18:15:27.940", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-02-27T16:15:13.577", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113_1" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113_1" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-17 16:15
Modified
2025-03-17 14:49
Severity ?
Summary
Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexecommand_cmdi.md | Exploit, Third Party Advisory, Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexecommand_cmdi.md | Exploit, Third Party Advisory, Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter." }, { "lang": "es", "value": "El firmware Tenda AC500 V2.0.1.9(1307) contiene una vulnerabilidad de inyecci\u00f3n de comandos en la funci\u00f3n formexeCommand a trav\u00e9s del par\u00e1metro cmdinput." } ], "id": "CVE-2024-32314", "lastModified": "2025-03-17T14:49:03.973", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 3.8, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 2.5, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-04-17T16:15:08.950", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexecommand_cmdi.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexecommand_cmdi.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-17 12:15
Modified
2025-01-17 21:16
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261144. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formWriteFacMac.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.261144 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.261144 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.313803 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formWriteFacMac.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.261144 | Permissions Required, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.261144 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.313803 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261144. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad ha sido encontrada en Tenda AC500 2.0.1.9(1307) y clasificada como cr\u00edtica. La funci\u00f3n formWriteFacMac del fichero /goform/WriteFacMac es afectada por la vulnerabilidad. La manipulaci\u00f3n del argumento mac conduce a la inyecci\u00f3n de comandos. Es posible lanzar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-261144. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-3908", "lastModified": "2025-01-17T21:16:07.327", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.4, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-04-17T12:15:07.633", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formWriteFacMac.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261144" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.261144" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.313803" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formWriteFacMac.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261144" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.261144" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.313803" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-27 16:15
Modified
2025-03-10 18:15
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113_2 | Exploit, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113_2 | Exploit, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid." } ], "id": "CVE-2023-25235", "lastModified": "2025-03-10T18:15:28.137", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-02-27T16:15:13.637", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Vendor Advisory" ], "url": "https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113_2" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Vendor Advisory" ], "url": "https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113_2" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-17 11:15
Modified
2025-01-17 21:21
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetCfm.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.261143 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.261143 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.313802 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetCfm.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.261143 | Permissions Required, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.261143 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.313802 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC500 2.0.1.9(1307). Ha sido calificada como cr\u00edtica. Este problema afecta a la funci\u00f3n formSetCfm del archivo /goform/setcfm. La manipulaci\u00f3n del argumento funcpara1 provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-261143. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-3907", "lastModified": "2025-01-17T21:21:37.327", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-04-17T11:15:12.160", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetCfm.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261143" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.261143" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.313802" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetCfm.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261143" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.261143" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.313802" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-07-14 08:15
Modified
2025-07-17 17:51
Severity ?
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation of the argument radio_2g_1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/panda666-888/vuls/blob/main/tenda/ac500/formSetAPCfg.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://github.com/panda666-888/vuls/blob/main/tenda/ac500/formSetAPCfg.md#poc | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.316285 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.316285 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.615169 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation of the argument radio_2g_1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC500 2.0.1.9(1307). Se ha declarado cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n formSetAPCfg del archivo /goform/setWtpData. La manipulaci\u00f3n del argumento radio_2g_1 provoca un desbordamiento del b\u00fafer basado en la pila. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-7586", "lastModified": "2025-07-17T17:51:04.283", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "PROOF_OF_CONCEPT", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-07-14T08:15:24.703", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ac500/formSetAPCfg.md" }, { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ac500/formSetAPCfg.md#poc" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.316285" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.316285" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.615169" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-02-27 16:15
Modified
2025-03-10 14:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInterface.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInterface." } ], "id": "CVE-2023-25233", "lastModified": "2025-03-10T14:15:23.970", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-02-27T16:15:13.513", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/113" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-17 16:15
Modified
2025-04-09 14:20
Severity ?
Summary
A Buffer Overflow vulnerability in Tenda AC500 v.2.0.1.9 allows a remote attacker to cause a denial of service via the port parameter at the goform/setVlanInfo component.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/Tenda/ac500/fromSetVlanInfo/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/Tenda/ac500/fromSetVlanInfo/1.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9 | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9:*:*:*:*:*:*:*", "matchCriteriaId": "7738AE83-A76E-47DC-8F78-F0328871FCD8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A Buffer Overflow vulnerability in Tenda AC500 v.2.0.1.9 allows a remote attacker to cause a denial of service via the port parameter at the goform/setVlanInfo component." }, { "lang": "es", "value": "Una vulnerabilidad de desbordamiento de b\u00fafer en Tenda AC500 v.2.0.1.9 permite a un atacante remoto provocar una denegaci\u00f3n de servicio a trav\u00e9s del par\u00e1metro de puerto en el componente goform/setVlanInfo." } ], "id": "CVE-2023-46060", "lastModified": "2025-04-09T14:20:45.230", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-04-17T16:15:07.333", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/Tenda/ac500/fromSetVlanInfo/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/Tenda/ac500/fromSetVlanInfo/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-17 11:15
Modified
2025-01-21 18:39
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/R7WebsSecurityHandler.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.261141 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.261141 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.313790 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/R7WebsSecurityHandler.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.261141 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.261141 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.313790 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC500 2.0.1.9(1307). Ha sido clasificada como cr\u00edtica. Esto afecta a la funci\u00f3n R7WebsSecurityHandler del archivo /goform/execCommand. La manipulaci\u00f3n del argumento contrase\u00f1a provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible iniciar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-261141. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-3905", "lastModified": "2025-01-21T18:39:28.047", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-04-17T11:15:11.620", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/R7WebsSecurityHandler.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261141" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.261141" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.313790" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/R7WebsSecurityHandler.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261141" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.261141" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.313790" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-17 16:15
Modified
2025-03-17 14:48
Severity ?
Summary
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_list1.md | Exploit, Third Party Advisory, Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_list1.md | Exploit, Third Party Advisory, Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function." }, { "lang": "es", "value": "El firmware Tenda AC500 V2.0.1.9(1307) tiene una vulnerabilidad de desbordamiento de pila en la funci\u00f3n fromDhcpListClient." } ], "id": "CVE-2024-32316", "lastModified": "2025-03-17T14:48:51.743", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-04-17T16:15:09.013", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_list1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_list1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-17 12:15
Modified
2025-02-07 01:57
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md | Broken Link | |
cna@vuldb.com | https://vuldb.com/?ctiid.261145 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.261145 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.313804 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md | Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.261145 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.261145 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.313804 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC500 2.0.1.9(1307) y clasificada como cr\u00edtica. La funci\u00f3n formexeCommand del archivo /goform/execCommand es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento cmdinput provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-261145. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-3909", "lastModified": "2025-02-07T01:57:01.643", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-04-17T12:15:07.853", "references": [ { "source": "cna@vuldb.com", "tags": [ "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261145" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.261145" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.313804" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formexeCommand.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261145" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.261145" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.313804" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-17 11:15
Modified
2025-01-21 18:36
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formQuickIndex.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.261142 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.261142 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.313801 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formQuickIndex.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.261142 | Permissions Required, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.261142 | Permissions Required, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.313801 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC500 2.0.1.9(1307). Ha sido declarada cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n formQuickIndex del archivo /goform/QuickIndex. La manipulaci\u00f3n del argumento PPPOEPassword provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-261142 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-3906", "lastModified": "2025-01-21T18:36:45.397", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-04-17T11:15:11.947", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formQuickIndex.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261142" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?id.261142" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.313801" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formQuickIndex.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261142" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?id.261142" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.313801" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-17 12:15
Modified
2025-01-21 17:57
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_page.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.261146 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.261146 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.313805 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_page.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.261146 | Permissions Required, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.261146 | Permissions Required, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.313805 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC500 2.0.1.9(1307) y clasificada como cr\u00edtica. La funci\u00f3n fromDhcpListClient del archivo /goform/DhcpListClient es afectada por esta vulnerabilidad. La manipulaci\u00f3n de la p\u00e1gina de argumentos provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-261146 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-3910", "lastModified": "2025-01-21T17:57:24.917", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-04-17T12:15:08.070", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_page.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261146" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?id.261146" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.313805" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromDhcpListClient_page.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261146" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?id.261146" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.313805" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-10-23 14:15
Modified
2024-11-01 14:03
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md | Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.281555 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.281555 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.426417 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - | |
tenda | ac10u_firmware | 15.03.06.48 | |
tenda | ac10u_firmware | 15.03.06.49 | |
tenda | ac10u | - | |
tenda | ac500_firmware | 1.0.0.14 | |
tenda | ac500_firmware | 1.0.0.16 | |
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - | |
tenda | ac18_firmware | 15.03.05.05 | |
tenda | ac18_firmware | 15.03.05.19\(6318\) | |
tenda | ac18 | - | |
tenda | ac9_firmware | 15.03.2.13 | |
tenda | ac9_firmware | 15.03.05.14 | |
tenda | ac9_firmware | 15.03.05.19\(6318\) | |
tenda | ac9 | 1.0 | |
tenda | ac9_firmware | 15.03.06.42 | |
tenda | ac9 | 3.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac10_firmware | 16.03.10.13 | |
tenda | ac10_firmware | 16.03.10.20 | |
tenda | ac10 | 4.0 | |
tenda | ac10_firmware | 16.03.48.19 | |
tenda | ac10_firmware | 16.03.48.23 | |
tenda | ac10 | 5.0 | |
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8_firmware | 16.03.34.09 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*", "matchCriteriaId": "1C2AFD04-833D-4085-BAD6-32A2715FA785", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*", "matchCriteriaId": "0F101E88-BEA9-4017-9048-860DF3D1BBBC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10u:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDBE5E26-7967-4FDD-A29F-7740B29C4B8E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*", "matchCriteriaId": "61BA4026-93A8-4D83-815E-397A2EC0A279", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*", "matchCriteriaId": "816A7A37-5952-4B22-80F7-8CD09383E079", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*", "matchCriteriaId": "4D5CB727-FC6B-4212-A61E-2888A0DADFB0", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*", "matchCriteriaId": "3AC468E5-44D1-4B94-B308-C1025DB1BB7B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.13:*:*:*:*:*:*:*", "matchCriteriaId": "3473D6FD-4D42-46D0-9D96-F95D6D856E8E", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.14:*:*:*:*:*:*:*", "matchCriteriaId": "DA7503C5-02C6-4016-A4C6-414146719BFF", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*", "matchCriteriaId": "D8F25141-8B57-463D-AB97-F52C0143973C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42:*:*:*:*:*:*:*", "matchCriteriaId": "5B0A5168-9E0C-43F7-BF7B-3943A3316CB8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*", "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.20:*:*:*:*:*:*:*", "matchCriteriaId": "A19C486B-52A3-4C3E-851D-F349E8E0A706", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.48.19:*:*:*:*:*:*:*", "matchCriteriaId": "DABA74C0-297A-4372-B84D-00BA0D334318", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.48.23:*:*:*:*:*:*:*", "matchCriteriaId": "AC3020CA-7422-4B9A-AA7B-C2B1A03A4450", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:5.0:*:*:*:*:*:*:*", "matchCriteriaId": "2BCFFBD6-3DAD-4FEA-9B5D-D7CBFC36572D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*", "matchCriteriaId": "EE69F412-6FC7-470D-BC7E-B3AAC6B4585F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se ha detectado una vulnerabilidad en Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 y AC1206 hasta 20241022. Se ha calificado como problem\u00e1tica. Este problema afecta a la funci\u00f3n websReadEvent del archivo /goform/GetIPTV. La manipulaci\u00f3n del argumento Content-Length provoca la desreferenciaci\u00f3n de puntero nulo. El ataque puede iniciarse de forma remota. El exploit se ha hecho p\u00fablico y puede utilizarse." } ], "id": "CVE-2024-10280", "lastModified": "2024-11-01T14:03:20.267", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 6.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2024-10-23T14:15:04.500", "references": [ { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.281555" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.281555" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.426417" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-476" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-17 16:15
Modified
2025-03-17 14:48
Severity ?
Summary
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetTimeZone.md | Exploit, Third Party Advisory, Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetTimeZone.md | Exploit, Third Party Advisory, Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function." }, { "lang": "es", "value": "El firmware Tenda AC500 V2.0.1.9(1307) tiene una vulnerabilidad de desbordamiento de pila a trav\u00e9s del par\u00e1metro timeZone en la funci\u00f3n formSetTimeZone." } ], "id": "CVE-2024-32320", "lastModified": "2025-03-17T14:48:17.427", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-04-17T16:15:09.190", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetTimeZone.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/formSetTimeZone.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-17 16:15
Modified
2025-03-17 14:48
Severity ?
Summary
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromSetVlanInfo_vlan.md | Exploit, Third Party Advisory, Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromSetVlanInfo_vlan.md | Exploit, Third Party Advisory, Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function." }, { "lang": "es", "value": "El firmware Tenda AC500 V2.0.1.9(1307) tiene una vulnerabilidad de desbordamiento de pila a trav\u00e9s del par\u00e1metro vlan en la funci\u00f3n formSetVlanInfo." } ], "id": "CVE-2024-32318", "lastModified": "2025-03-17T14:48:41.270", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-04-17T16:15:09.130", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromSetVlanInfo_vlan.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC500/fromSetVlanInfo_vlan.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Primary" } ] }