Vulnerabilites related to Siemens AG - Automation License Manager 5
CVE-2018-11456 (GCVE-0-2018-11456)
Vulnerability from cvelistv5
Published
2018-08-07 15:00
Modified
2024-08-05 08:10
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-284 - Improper Access Control
Summary
A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is required. The impact is limited to determining whether or not a port on a target system is accessible by the affected device.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens AG | Automation License Manager 5 |
Version: Automation License Manager 5 : All versions < 5.3.4.4 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T08:10:14.363Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "105114", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/105114" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-920962.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Automation License Manager 5", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "Automation License Manager 5 : All versions \u003c 5.3.4.4" } ] } ], "datePublic": "2018-08-07T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Automation License Manager 5 (All versions \u003c 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is required. The impact is limited to determining whether or not a port on a target system is accessible by the affected device." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284: Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-08-21T09:57:01", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "105114", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/105114" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-920962.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2018-11456", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Automation License Manager 5", "version": { "version_data": [ { "version_value": "Automation License Manager 5 : All versions \u003c 5.3.4.4" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Automation License Manager 5 (All versions \u003c 5.3.4.4). An attacker with network access to the device could send specially crafted network packets to determine whether or not a network port on another remote system is accessible or not. This allows the attacker to do basic network scanning using the victims machine. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges, no user interaction is required. The impact is limited to determining whether or not a port on a target system is accessible by the affected device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-284: Improper Access Control" } ] } ] }, "references": { "reference_data": [ { "name": "105114", "refsource": "BID", "url": "http://www.securityfocus.com/bid/105114" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-920962.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-920962.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-11456", "datePublished": "2018-08-07T15:00:00", "dateReserved": "2018-05-25T00:00:00", "dateUpdated": "2024-08-05T08:10:14.363Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-7583 (GCVE-0-2020-7583)
Vulnerability from cvelistv5
Published
2020-08-14 15:24
Modified
2024-08-04 09:33
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-285 - Improper Authorization
Summary
A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions < V6.0.8). The application does not properly validate the users' privileges when executing some operations, which could allow a user with low permissions to arbitrary modify files that should be protected against writing.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | Automation License Manager 5 |
Version: All versions |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.886Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-388646.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Automation License Manager 5", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "Automation License Manager 6", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V6.0.8" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions \u003c V6.0.8). The application does not properly validate the users\u0027 privileges when executing some operations, which could allow a user with low permissions to arbitrary modify files that should be protected against writing." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-285", "description": "CWE-285: Improper Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-08-14T15:24:06", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-388646.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-7583", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Automation License Manager 5", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "Automation License Manager 6", "version": { "version_data": [ { "version_value": "All versions \u003c V6.0.8" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions \u003c V6.0.8). The application does not properly validate the users\u0027 privileges when executing some operations, which could allow a user with low permissions to arbitrary modify files that should be protected against writing." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-285: Improper Authorization" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-388646.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-388646.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7583", "datePublished": "2020-08-14T15:24:06", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.886Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }