Vulnerabilites related to Silver Peak Systems, Inc. - ECOS
CVE-2020-12148 (GCVE-0-2020-12148)
Vulnerability from cvelistv5
Published
2020-12-11 15:24
Modified
2024-09-16 23:05
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
A command injection flaw identified in the nslookup API in Silver Peak Unity ECOSTM (ECOS) appliance software could allow an attacker to execute arbitrary commands with the privileges of the web server running on the EdgeConnect appliance. An attacker could exploit this vulnerability to establish an interactive channel, effectively taking control of the target system. This vulnerability can be exploited by an attacker with authenticated access to the Orchestrator UI or EdgeConnect UI. This affects all ECOS versions prior to : 8.1.9.15, 8.3.0.8, 8.3.1.2, 8.3.2.0, 9.0.2.0, and 9.1.0.0.
References
► | URL | Tags |
---|---|---|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Silver Peak Systems, Inc. | ECOS |
Version: All current ECOS versions prior to 8.1.9.15 Version: 8.3.0.8 Version: 8.3.1.2 Version: 8.3.2.0 Version: 9.0.2.0 Version: and 9.1.0.0 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:48:58.361Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.silver-peak.com/support/user-documentation/security-advisories" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "ECOS", "vendor": "Silver Peak Systems, Inc.", "versions": [ { "status": "affected", "version": "All current ECOS versions prior to 8.1.9.15" }, { "status": "affected", "version": "8.3.0.8" }, { "status": "affected", "version": "8.3.1.2" }, { "status": "affected", "version": "8.3.2.0" }, { "status": "affected", "version": "9.0.2.0" }, { "status": "affected", "version": "and 9.1.0.0" } ] } ], "credits": [ { "lang": "en", "value": "This vulnerability was reported to Silver Peak by Alexander Smye and Jonathan Letham from the security team at NCC Group." } ], "datePublic": "2020-11-30T00:00:00", "descriptions": [ { "lang": "en", "value": "A command injection flaw identified in the nslookup API in Silver Peak Unity ECOSTM (ECOS) appliance software could allow an attacker to execute arbitrary commands with the privileges of the web server running on the EdgeConnect appliance. An attacker could exploit this vulnerability to establish an interactive channel, effectively taking control of the target system. This vulnerability can be exploited by an attacker with authenticated access to the Orchestrator UI or EdgeConnect UI. This affects all ECOS versions prior to : 8.1.9.15, 8.3.0.8, 8.3.1.2, 8.3.2.0, 9.0.2.0, and 9.1.0.0." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 OS Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-15T16:13:57", "orgId": "83cc1b1a-46b0-4ac1-94f2-bbef3319bc4c", "shortName": "Silver Peak" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.silver-peak.com/support/user-documentation/security-advisories" } ], "source": { "advisory": "2020-11-15-01-001", "discovery": "EXTERNAL" }, "title": "OS Command Injection - nslookup API", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "sirt@silver-peak.com", "DATE_PUBLIC": "2020-11-30T17:30:00.000Z", "ID": "CVE-2020-12148", "STATE": "PUBLIC", "TITLE": "OS Command Injection - nslookup API" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "ECOS", "version": { "version_data": [ { "version_value": "All current ECOS versions prior to 8.1.9.15" }, { "version_value": "8.3.0.8" }, { "version_value": "8.3.1.2" }, { "version_value": "8.3.2.0" }, { "version_value": "9.0.2.0" }, { "version_value": "and 9.1.0.0" } ] } } ] }, "vendor_name": "Silver Peak Systems, Inc." } ] } }, "credit": [ { "lang": "eng", "value": "This vulnerability was reported to Silver Peak by Alexander Smye and Jonathan Letham from the security team at NCC Group." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A command injection flaw identified in the nslookup API in Silver Peak Unity ECOSTM (ECOS) appliance software could allow an attacker to execute arbitrary commands with the privileges of the web server running on the EdgeConnect appliance. An attacker could exploit this vulnerability to establish an interactive channel, effectively taking control of the target system. This vulnerability can be exploited by an attacker with authenticated access to the Orchestrator UI or EdgeConnect UI. This affects all ECOS versions prior to : 8.1.9.15, 8.3.0.8, 8.3.1.2, 8.3.2.0, 9.0.2.0, and 9.1.0.0." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" } ] }, { "description": [ { "lang": "eng", "value": "CWE-78 OS Command Injection" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.silver-peak.com/support/user-documentation/security-advisories", "refsource": "MISC", "url": "https://www.silver-peak.com/support/user-documentation/security-advisories" } ] }, "source": { "advisory": "2020-11-15-01-001", "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "83cc1b1a-46b0-4ac1-94f2-bbef3319bc4c", "assignerShortName": "Silver Peak", "cveId": "CVE-2020-12148", "datePublished": "2020-12-11T15:24:23.056324Z", "dateReserved": "2020-04-24T00:00:00", "dateUpdated": "2024-09-16T23:05:48.430Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2020-12149 (GCVE-0-2020-12149)
Vulnerability from cvelistv5
Published
2020-12-11 15:23
Modified
2024-09-16 23:26
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
The configuration backup/restore function in Silver Peak Unity ECOSTM (ECOS) appliance software was found to directly incorporate the user-controlled config filename in a subsequent shell command, allowing an attacker to manipulate the resulting command by injecting valid OS command input. This vulnerability can be exploited by an attacker with authenticated access to the Orchestrator UI or EdgeConnect UI. This affects all ECOS versions prior to: 8.1.9.15, 8.3.0.8, 8.3.1.2, 8.3.2.0, 9.0.2.0, and 9.1.0.0.
References
► | URL | Tags |
---|---|---|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Silver Peak Systems, Inc. | ECOS |
Version: All current ECOS versions prior to 8.1.9.15 Version: 8.3.0.8 Version: 8.3.1.2 Version: 8.3.2.0 Version: 9.0.2.0 Version: and 9.1.0.0 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T11:48:58.307Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.silver-peak.com/support/user-documentation/security-advisories" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "ECOS", "vendor": "Silver Peak Systems, Inc.", "versions": [ { "status": "affected", "version": "All current ECOS versions prior to 8.1.9.15" }, { "status": "affected", "version": "8.3.0.8" }, { "status": "affected", "version": "8.3.1.2" }, { "status": "affected", "version": "8.3.2.0" }, { "status": "affected", "version": "9.0.2.0" }, { "status": "affected", "version": "and 9.1.0.0" } ] } ], "credits": [ { "lang": "en", "value": "This vulnerability was reported to Silver Peak by Alexander Smye and Jonathan Letham from the security team at NCC Group." } ], "datePublic": "2020-11-30T00:00:00", "descriptions": [ { "lang": "en", "value": "The configuration backup/restore function in Silver Peak Unity ECOSTM (ECOS) appliance software was found to directly incorporate the user-controlled config filename in a subsequent shell command, allowing an attacker to manipulate the resulting command by injecting valid OS command input. This vulnerability can be exploited by an attacker with authenticated access to the Orchestrator UI or EdgeConnect UI. This affects all ECOS versions prior to: 8.1.9.15, 8.3.0.8, 8.3.1.2, 8.3.2.0, 9.0.2.0, and 9.1.0.0." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 OS Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-15T16:14:01", "orgId": "83cc1b1a-46b0-4ac1-94f2-bbef3319bc4c", "shortName": "Silver Peak" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.silver-peak.com/support/user-documentation/security-advisories" } ], "solutions": [ { "lang": "en", "value": "The backup/restore functions in the patched versions of ECOS software have been modified to only accept alphanumeric characters, along with the period, hyphen, and underscore characters. This change ensures that OS commands cannot be injected via filename." } ], "source": { "advisory": "2020-11-15-01-002", "discovery": "EXTERNAL" }, "title": "OS Command Injection - Management File Upload", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "sirt@silver-peak.com", "DATE_PUBLIC": "2020-11-30T17:30:00.000Z", "ID": "CVE-2020-12149", "STATE": "PUBLIC", "TITLE": "OS Command Injection - Management File Upload" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "ECOS", "version": { "version_data": [ { "version_value": "All current ECOS versions prior to 8.1.9.15" }, { "version_value": "8.3.0.8" }, { "version_value": "8.3.1.2" }, { "version_value": "8.3.2.0" }, { "version_value": "9.0.2.0" }, { "version_value": "and 9.1.0.0" } ] } } ] }, "vendor_name": "Silver Peak Systems, Inc." } ] } }, "credit": [ { "lang": "eng", "value": "This vulnerability was reported to Silver Peak by Alexander Smye and Jonathan Letham from the security team at NCC Group." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The configuration backup/restore function in Silver Peak Unity ECOSTM (ECOS) appliance software was found to directly incorporate the user-controlled config filename in a subsequent shell command, allowing an attacker to manipulate the resulting command by injecting valid OS command input. This vulnerability can be exploited by an attacker with authenticated access to the Orchestrator UI or EdgeConnect UI. This affects all ECOS versions prior to: 8.1.9.15, 8.3.0.8, 8.3.1.2, 8.3.2.0, 9.0.2.0, and 9.1.0.0." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" } ] }, { "description": [ { "lang": "eng", "value": "CWE-78 OS Command Injection" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.silver-peak.com/support/user-documentation/security-advisories", "refsource": "MISC", "url": "https://www.silver-peak.com/support/user-documentation/security-advisories" } ] }, "solution": [ { "lang": "en", "value": "The backup/restore functions in the patched versions of ECOS software have been modified to only accept alphanumeric characters, along with the period, hyphen, and underscore characters. This change ensures that OS commands cannot be injected via filename." } ], "source": { "advisory": "2020-11-15-01-002", "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "83cc1b1a-46b0-4ac1-94f2-bbef3319bc4c", "assignerShortName": "Silver Peak", "cveId": "CVE-2020-12149", "datePublished": "2020-12-11T15:23:32.991669Z", "dateReserved": "2020-04-24T00:00:00", "dateUpdated": "2024-09-16T23:26:33.482Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }