Vulnerabilites related to Phoenix Contact - FL COMSERVER
CVE-2021-21002 (GCVE-0-2021-21002)
Vulnerability from cvelistv5
Published
2021-06-25 18:25
Modified
2024-09-17 03:58
CWE
  • CWE-772 - Missing Release of Resource after Effective Lifetime
Summary
In Phoenix Contact FL COMSERVER UNI in versions < 2.40 a invalid Modbus exception response can lead to a temporary denial of service.
References
Impacted products
Vendor Product Version
Phoenix Contact FL COMSERVER Version: UNI 232/422/485 (2313452)   < 2.40
Version: UNI 232/422/485-T (2904817)   < 2.40
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:53:23.033Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en-us/advisories/vde-2021-022"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "FL COMSERVER",
          "vendor": "Phoenix Contact",
          "versions": [
            {
              "lessThan": "2.40",
              "status": "affected",
              "version": "UNI 232/422/485 (2313452)",
              "versionType": "custom"
            },
            {
              "lessThan": "2.40",
              "status": "affected",
              "version": "UNI 232/422/485-T (2904817)",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "This vulnerability was found by Petri Tuomio and reported to PHOENIX CONTACT by Waertsilae PSIRT. PHOENIX CONTACT thanks CERT@VDE for the coordination and support with this publication."
        }
      ],
      "datePublic": "2021-06-23T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Phoenix Contact FL COMSERVER UNI in versions \u003c 2.40 a invalid Modbus exception response can lead to a temporary denial of service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-772",
              "description": "CWE-772 Missing Release of Resource after Effective Lifetime",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-25T18:25:50",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en-us/advisories/vde-2021-022"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Upgrade to the latest firmware, fixed firmware includes versions \u003e= 2.41."
        }
      ],
      "source": {
        "advisory": "VDE-2021-022",
        "defect": [
          "VDE-2021-022"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "Denial of Service in Phoenix Contact FL COMSERVER UNI products",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2021-06-23T10:00:00.000Z",
          "ID": "CVE-2021-21002",
          "STATE": "PUBLIC",
          "TITLE": "Denial of Service in Phoenix Contact FL COMSERVER UNI products"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "FL COMSERVER",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "UNI 232/422/485 (2313452)",
                            "version_value": "2.40"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "UNI 232/422/485-T (2904817)",
                            "version_value": "2.40"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Phoenix Contact"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "This vulnerability was found by Petri Tuomio and reported to PHOENIX CONTACT by Waertsilae PSIRT. PHOENIX CONTACT thanks CERT@VDE for the coordination and support with this publication."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Phoenix Contact FL COMSERVER UNI in versions \u003c 2.40 a invalid Modbus exception response can lead to a temporary denial of service."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-772 Missing Release of Resource after Effective Lifetime"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en-us/advisories/vde-2021-022",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en-us/advisories/vde-2021-022"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Upgrade to the latest firmware, fixed firmware includes versions \u003e= 2.41."
          }
        ],
        "source": {
          "advisory": "VDE-2021-022",
          "defect": [
            "VDE-2021-022"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2021-21002",
    "datePublished": "2021-06-25T18:25:50.373345Z",
    "dateReserved": "2020-12-17T00:00:00",
    "dateUpdated": "2024-09-17T03:58:42.845Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}