Vulnerabilites related to Mitsubishi Electric Corporation - MELSEC iQ-R Series R04/08/16/32/120ENCPU
CVE-2022-40265 (GCVE-0-2022-40265)
Vulnerability from cvelistv5
Published
2022-11-30 00:04
Modified
2025-04-24 18:45
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-20 - Improper Input Validation
Summary
Improper Input Validation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series RJ71EN71 Firmware version "65" and prior and Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120ENCPU Network Part Firmware version "65" and prior allows a remote unauthenticated attacker to cause a Denial of Service condition by sending specially crafted packets. A system reset is required for recovery.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Mitsubishi Electric Corporation | MELSEC iQ-R Series RJ71EN71 |
Version: Firmware version "65" and prior |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T12:14:40.016Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-017_en.pdf" }, { "tags": [ "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU94702422" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-40265", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-04-24T18:44:56.498040Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-04-24T18:45:03.895Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "MELSEC iQ-R Series RJ71EN71", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "Firmware version \"65\" and prior" } ] }, { "product": "MELSEC iQ-R Series R04/08/16/32/120ENCPU", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "Network Part Firmware version \"65\" and prior" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Input Validation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series RJ71EN71 Firmware version \"65\" and prior and Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120ENCPU Network Part Firmware version \"65\" and prior allows a remote unauthenticated attacker to cause a Denial of Service condition by sending specially crafted packets. A system reset is required for recovery." } ], "value": "Improper Input Validation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series RJ71EN71 Firmware version \"65\" and prior and Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120ENCPU Network Part Firmware version \"65\" and prior allows a remote unauthenticated attacker to cause a Denial of Service condition by sending specially crafted packets. A system reset is required for recovery." } ], "impacts": [ { "descriptions": [ { "lang": "en", "value": "Denial of Service" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-11-30T00:04:43.069Z", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-017_en.pdf" }, { "url": "https://jvn.jp/vu/JVNVU94702422" } ], "source": { "discovery": "UNKNOWN" }, "title": "Denial of Service (DoS) Vulnerability in MELSEC iQ-R Series Ethernet Interface Module", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2022-40265", "datePublished": "2022-11-30T00:04:43.069Z", "dateReserved": "2022-09-08T19:40:16.931Z", "dateUpdated": "2025-04-24T18:45:03.895Z", "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }