Vulnerabilites related to Johnnson Controls - Metasys System Configuration Tool (SCT)
CVE-2021-36203 (GCVE-0-2021-36203)
Vulnerability from cvelistv5
Published
2022-04-22 14:44
Modified
2024-09-17 02:12
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-918 - Server-Side Request Forgery (SSRF)
Summary
The affected product may allow an attacker to identify and forge requests to internal systems by way of a specially crafted request.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Johnnson Controls | Metasys System Configuration Tool (SCT) |
Version: All < 14.2.2 |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T00:54:50.703Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-111-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Metasys System Configuration Tool (SCT)", "vendor": "Johnnson Controls", "versions": [ { "lessThan": "14.2.2", "status": "affected", "version": "All", "versionType": "custom" } ] }, { "product": "Metasys System Configuration Tool Pro (SCT Pro)", "vendor": "Johnnson Controls", "versions": [ { "lessThan": "14.2.2", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Tony West and Scott Ponte reported this vulnerability to Johnson Controls. Johnson Controls reported this vulnerability to CISA." } ], "datePublic": "2022-04-21T00:00:00", "descriptions": [ { "lang": "en", "value": "The affected product may allow an attacker to identify and forge requests to internal systems by way of a specially crafted request." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-918", "description": "CWE-918 Server-Side Request Forgery (SSRF)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-03T19:29:50", "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01", "shortName": "jci" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-111-02" } ], "solutions": [ { "lang": "en", "value": "Johnson Controls recommends users take the following steps to mitigate this vulnerability:\n\nUpdate SCT/SCT Pro with Patch 14.2.2\nTake proper steps to minimize risks to all building automation systems.\nFor more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2022-03 v1" } ], "source": { "advisory": "ICSA-22-111-02", "discovery": "EXTERNAL" }, "title": "Johnson Controls Metasys SCT Pro", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productsecurity@jci.com", "DATE_PUBLIC": "2022-04-21T17:00:00.000Z", "ID": "CVE-2021-36203", "STATE": "PUBLIC", "TITLE": "Johnson Controls Metasys SCT Pro" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Metasys System Configuration Tool (SCT)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "All", "version_value": "14.2.2" } ] } }, { "product_name": "Metasys System Configuration Tool Pro (SCT Pro)", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "All", "version_value": "14.2.2" } ] } } ] }, "vendor_name": "Johnnson Controls" } ] } }, "credit": [ { "lang": "eng", "value": "Tony West and Scott Ponte reported this vulnerability to Johnson Controls. Johnson Controls reported this vulnerability to CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The affected product may allow an attacker to identify and forge requests to internal systems by way of a specially crafted request." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-918 Server-Side Request Forgery (SSRF)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-111-02", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-111-02" } ] }, "solution": [ { "lang": "en", "value": "Johnson Controls recommends users take the following steps to mitigate this vulnerability:\n\nUpdate SCT/SCT Pro with Patch 14.2.2\nTake proper steps to minimize risks to all building automation systems.\nFor more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2022-03 v1" } ], "source": { "advisory": "ICSA-22-111-02", "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01", "assignerShortName": "jci", "cveId": "CVE-2021-36203", "datePublished": "2022-04-22T14:44:10.638332Z", "dateReserved": "2021-07-06T00:00:00", "dateUpdated": "2024-09-17T02:12:16.472Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }