Vulnerabilites related to Fuji Electric - Monitouch V-SFT
CVE-2024-11933 (GCVE-0-2024-11933)
Vulnerability from cvelistv5
Published
2024-11-27 23:36
Modified
2024-11-29 16:59
CWE
  • CWE-122 - Heap-based Buffer Overflow
Summary
Fuji Electric Monitouch V-SFT X1 File Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of X1 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24548.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:monitouch_v-sft:6.2.3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "monitouch_v-sft",
            "vendor": "fujielectric",
            "versions": [
              {
                "status": "affected",
                "version": "6.2.3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11933",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T16:59:16.877074Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T16:59:46.846Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "6.2.3.0"
            }
          ]
        }
      ],
      "dateAssigned": "2024-11-27T14:52:50.875-06:00",
      "datePublic": "2024-11-27T15:01:43.341-06:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric Monitouch V-SFT X1 File Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of X1 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24548."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-27T23:36:05.162Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1630",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1630/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "kimiya"
      },
      "title": "Fuji Electric Monitouch V-SFT X1 File Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-11933",
    "datePublished": "2024-11-27T23:36:05.162Z",
    "dateReserved": "2024-11-27T20:52:50.825Z",
    "dateUpdated": "2024-11-29T16:59:46.846Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-5597 (GCVE-0-2024-5597)
Vulnerability from cvelistv5
Published
2024-06-10 16:53
Modified
2024-08-01 21:18
CWE
Summary
Fuji Electric Monitouch V-SFT is vulnerable to a type confusion, which could cause a crash or code execution.
Impacted products
Vendor Product Version
Fuji Electric Monitouch V-SFT Version: 0   < 6.2.3.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5597",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-10T20:11:14.382101Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-10T20:12:13.322Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:18:06.595Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "lessThan": "6.2.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "kimiya working with Trend Micro Zero Day Initiative, reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Fuji Electric Monitouch V-SFT\u0026nbsp;\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eis vulnerable to a type confusion, which could cause a crash or code execution.\u003c/span\u003e\n\n"
            }
          ],
          "value": "Fuji Electric Monitouch V-SFT\u00a0is vulnerable to a type confusion, which could cause a crash or code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "CWE-843 Type Confusion",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-10T16:53:50.147Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Fuji Electric recommends users update the product to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://felib.fujielectric.co.jp/en/M10009/M20104/document_detail/55ff739b-bd06-4241-b078-3b9c9728bdfd\"\u003eMonitouch V-SFT v6.2.3.0\u003c/a\u003e.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Fuji Electric recommends users update the product to  Monitouch V-SFT v6.2.3.0 https://felib.fujielectric.co.jp/en/M10009/M20104/document_detail/55ff739b-bd06-4241-b078-3b9c9728bdfd ."
        }
      ],
      "source": {
        "advisory": "ICSA-24-151-02",
        "discovery": "EXTERNAL"
      },
      "title": "Fuji Electric Monitouch V-SFT Type Confusion",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-5597",
    "datePublished": "2024-06-10T16:53:50.147Z",
    "dateReserved": "2024-06-03T13:32:22.404Z",
    "dateUpdated": "2024-08-01T21:18:06.595Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11792 (GCVE-0-2024-11792)
Vulnerability from cvelistv5
Published
2024-11-27 23:34
Modified
2024-11-29 17:09
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
Fuji Electric Monitouch V-SFT V8 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of V8 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24502.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:monitouch_v-sft:6.2.3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "monitouch_v-sft",
            "vendor": "fujielectric",
            "versions": [
              {
                "status": "affected",
                "version": "6.2.3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11792",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T16:43:24.101858Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T17:09:48.771Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "6.2.3.0"
            }
          ]
        }
      ],
      "dateAssigned": "2024-11-26T10:01:44.222-06:00",
      "datePublic": "2024-11-27T14:58:32.703-06:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric Monitouch V-SFT V8 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of V8 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24502."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-27T23:34:28.147Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1618",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1618/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "kimiya"
      },
      "title": "Fuji Electric Monitouch V-SFT V8 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-11792",
    "datePublished": "2024-11-27T23:34:28.147Z",
    "dateReserved": "2024-11-26T16:01:44.192Z",
    "dateUpdated": "2024-11-29T17:09:48.771Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11796 (GCVE-0-2024-11796)
Vulnerability from cvelistv5
Published
2024-11-27 23:34
Modified
2024-11-29 16:59
CWE
Summary
Fuji Electric Monitouch V-SFT V9C File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of V9C files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24506.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:monitouch_v-sft:6.2.3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "monitouch_v-sft",
            "vendor": "fujielectric",
            "versions": [
              {
                "status": "affected",
                "version": "6.2.3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11796",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T16:43:24.101858Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T16:59:47.224Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "6.2.3.0"
            }
          ]
        }
      ],
      "dateAssigned": "2024-11-26T10:02:14.653-06:00",
      "datePublic": "2024-11-27T14:59:35.635-06:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric Monitouch V-SFT V9C File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of V9C files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24506."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-27T23:34:45.779Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1622",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1622/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "kimiya"
      },
      "title": "Fuji Electric Monitouch V-SFT V9C File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-11796",
    "datePublished": "2024-11-27T23:34:45.779Z",
    "dateReserved": "2024-11-26T16:02:14.631Z",
    "dateUpdated": "2024-11-29T16:59:47.224Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11789 (GCVE-0-2024-11789)
Vulnerability from cvelistv5
Published
2024-11-27 23:34
Modified
2024-11-29 17:09
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
Fuji Electric Monitouch V-SFT V10 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of V10 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24448.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:monitouch_v-sft:6.2.3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "monitouch_v-sft",
            "vendor": "fujielectric",
            "versions": [
              {
                "status": "affected",
                "version": "6.2.3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11789",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T16:43:24.101858Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T17:09:49.168Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "6.2.3.0"
            }
          ]
        }
      ],
      "dateAssigned": "2024-11-26T10:01:28.497-06:00",
      "datePublic": "2024-11-27T14:57:48.619-06:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric Monitouch V-SFT V10 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of V10 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24448."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-27T23:34:14.031Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1615",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1615/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "kimiya"
      },
      "title": "Fuji Electric Monitouch V-SFT V10 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-11789",
    "datePublished": "2024-11-27T23:34:14.031Z",
    "dateReserved": "2024-11-26T16:01:28.470Z",
    "dateUpdated": "2024-11-29T17:09:49.168Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11798 (GCVE-0-2024-11798)
Vulnerability from cvelistv5
Published
2024-11-27 23:34
Modified
2024-11-29 16:59
CWE
Summary
Fuji Electric Monitouch V-SFT X1 File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of X1 files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24663.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:monitouch_v-sft:6.2.3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "monitouch_v-sft",
            "vendor": "fujielectric",
            "versions": [
              {
                "status": "affected",
                "version": "6.2.3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11798",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T16:59:20.681042Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T16:59:46.980Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "6.2.3.0"
            }
          ]
        }
      ],
      "dateAssigned": "2024-11-26T10:02:25.810-06:00",
      "datePublic": "2024-11-27T15:00:00.203-06:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric Monitouch V-SFT X1 File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of X1 files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24663."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-27T23:34:53.455Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1624",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1624/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "kimiya"
      },
      "title": "Fuji Electric Monitouch V-SFT X1 File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-11798",
    "datePublished": "2024-11-27T23:34:53.455Z",
    "dateReserved": "2024-11-26T16:02:25.786Z",
    "dateUpdated": "2024-11-29T16:59:46.980Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-5271 (GCVE-0-2024-5271)
Vulnerability from cvelistv5
Published
2024-05-30 19:53
Modified
2025-07-24 14:42
CWE
  • CWE-843 - Access of Resource Using Incompatible Type ('Type Confusion')
Summary
Fuji Electric Monitouch V-SFT is vulnerable to an out-of-bounds write because of a type confusion, which could result in arbitrary code execution.
Impacted products
Vendor Product Version
Fuji Electric Monitouch V-SFT Version: 0   < 6.2.3.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:monitouch_v-sft:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "monitouch_v-sft",
            "vendor": "fujielectric",
            "versions": [
              {
                "lessThanOrEqual": "6.2.3.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5271",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-24T14:42:08.803828Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-24T14:42:21.260Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:11:11.627Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "lessThan": "6.2.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "kimiya working with Trend Micro Zero Day Initiative, reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Fuji Electric Monitouch V-SFT is vulnerable to an out-of-bounds write because of a\n type confusion, which could result in arbitrary code execution."
            }
          ],
          "value": "Fuji Electric Monitouch V-SFT is vulnerable to an out-of-bounds write because of a\n type confusion, which could result in arbitrary code execution."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-843",
              "description": "CWE-843 Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-18T17:45:36.547Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Fuji Electric recommends users update the product to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://felib.fujielectric.co.jp/en/M10009/M20104/document_detail/55ff739b-bd06-4241-b078-3b9c9728bdfd\"\u003eMonitouch V-SFT v6.2.3.0\u003c/a\u003e.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Fuji Electric recommends users update the product to  Monitouch V-SFT v6.2.3.0 https://felib.fujielectric.co.jp/en/M10009/M20104/document_detail/55ff739b-bd06-4241-b078-3b9c9728bdfd ."
        }
      ],
      "source": {
        "advisory": "ICSA-24-151-02",
        "discovery": "EXTERNAL"
      },
      "title": "Fuji Electric Monitouch V-SFT Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-5271",
    "datePublished": "2024-05-30T19:53:30.195Z",
    "dateReserved": "2024-05-23T14:36:06.242Z",
    "dateUpdated": "2025-07-24T14:42:21.260Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11791 (GCVE-0-2024-11791)
Vulnerability from cvelistv5
Published
2024-11-27 23:34
Modified
2024-11-29 17:09
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
Fuji Electric Monitouch V-SFT V8C File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of V8C files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24450.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:monitouch_v-sft:6.2.3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "monitouch_v-sft",
            "vendor": "fujielectric",
            "versions": [
              {
                "status": "affected",
                "version": "6.2.3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11791",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T16:43:24.101858Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T17:09:48.897Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "6.2.3.0"
            }
          ]
        }
      ],
      "dateAssigned": "2024-11-26T10:01:39.133-06:00",
      "datePublic": "2024-11-27T14:58:19.419-06:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric Monitouch V-SFT V8C File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of V8C files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24450."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-27T23:34:23.304Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1617",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1617/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "kimiya"
      },
      "title": "Fuji Electric Monitouch V-SFT V8C File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-11791",
    "datePublished": "2024-11-27T23:34:23.304Z",
    "dateReserved": "2024-11-26T16:01:39.099Z",
    "dateUpdated": "2024-11-29T17:09:48.897Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11787 (GCVE-0-2024-11787)
Vulnerability from cvelistv5
Published
2024-11-27 23:34
Modified
2024-11-29 17:09
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
Fuji Electric Monitouch V-SFT V10 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of V10 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24413.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:monitouch_v-sft:6.2.3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "monitouch_v-sft",
            "vendor": "fujielectric",
            "versions": [
              {
                "status": "affected",
                "version": "6.2.3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11787",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T16:43:24.101858Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T17:09:49.282Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "6.2.3.0"
            }
          ]
        }
      ],
      "dateAssigned": "2024-11-26T10:01:18.991-06:00",
      "datePublic": "2024-11-27T14:57:25.081-06:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric Monitouch V-SFT V10 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of V10 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24413."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-27T23:34:08.859Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1614",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1614/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "kimiya"
      },
      "title": "Fuji Electric Monitouch V-SFT V10 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-11787",
    "datePublished": "2024-11-27T23:34:08.859Z",
    "dateReserved": "2024-11-26T16:01:18.939Z",
    "dateUpdated": "2024-11-29T17:09:49.282Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11794 (GCVE-0-2024-11794)
Vulnerability from cvelistv5
Published
2024-11-27 23:34
Modified
2024-11-29 16:59
CWE
Summary
Fuji Electric Monitouch V-SFT V10 File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of V10 files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24504.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:monitouch_v-sft:6.2.3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "monitouch_v-sft",
            "vendor": "fujielectric",
            "versions": [
              {
                "status": "affected",
                "version": "6.2.3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11794",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T16:43:24.101858Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T16:59:47.461Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "6.2.3.0"
            }
          ]
        }
      ],
      "dateAssigned": "2024-11-26T10:02:03.353-06:00",
      "datePublic": "2024-11-27T14:58:59.212-06:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric Monitouch V-SFT V10 File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of V10 files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24504."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-27T23:34:36.653Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1620",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1620/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "kimiya"
      },
      "title": "Fuji Electric Monitouch V-SFT V10 File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-11794",
    "datePublished": "2024-11-27T23:34:36.653Z",
    "dateReserved": "2024-11-26T16:02:03.326Z",
    "dateUpdated": "2024-11-29T16:59:47.461Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11797 (GCVE-0-2024-11797)
Vulnerability from cvelistv5
Published
2024-11-27 23:34
Modified
2024-11-29 16:59
CWE
Summary
Fuji Electric Monitouch V-SFT V8 File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of V8 files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24662.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:monitouch_v-sft:6.2.3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "monitouch_v-sft",
            "vendor": "fujielectric",
            "versions": [
              {
                "status": "affected",
                "version": "6.2.3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11797",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T16:43:24.101858Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T16:59:47.107Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "6.2.3.0"
            }
          ]
        }
      ],
      "dateAssigned": "2024-11-26T10:02:21.266-06:00",
      "datePublic": "2024-11-27T14:59:46.632-06:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric Monitouch V-SFT V8 File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of V8 files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24662."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-27T23:34:50.024Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1623",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1623/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "kimiya"
      },
      "title": "Fuji Electric Monitouch V-SFT V8 File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-11797",
    "datePublished": "2024-11-27T23:34:50.024Z",
    "dateReserved": "2024-11-26T16:02:21.244Z",
    "dateUpdated": "2024-11-29T16:59:47.107Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-34171 (GCVE-0-2024-34171)
Vulnerability from cvelistv5
Published
2024-05-30 19:55
Modified
2024-08-02 02:51
CWE
Summary
Fuji Electric Monitouch V-SFT is vulnerable to a stack-based buffer overflow, which could allow an attacker to execute arbitrary code.
Impacted products
Vendor Product Version
Fuji Electric Monitouch V-SFT Version: 0   < 6.2.3.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:monitouch_v-sft:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "monitouch_v-sft",
            "vendor": "fujielectric",
            "versions": [
              {
                "lessThan": "6.2.3.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-34171",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-25T18:32:35.936779Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-25T18:33:50.822Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T02:51:09.599Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "lessThan": "6.2.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "kimiya working with Trend Micro Zero Day Initiative, reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\nFuji Electric Monitouch V-SFT \nis vulnerable to a stack-based buffer overflow, which could allow an attacker to execute arbitrary code.\n\n"
            }
          ],
          "value": "Fuji Electric Monitouch V-SFT \nis vulnerable to a stack-based buffer overflow, which could allow an attacker to execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-30T19:55:23.835Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\nFuji Electric recommends users update the product to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://felib.fujielectric.co.jp/en/M10009/M20104/document_detail/55ff739b-bd06-4241-b078-3b9c9728bdfd\"\u003eMonitouch V-SFT v6.2.3.0\u003c/a\u003e.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Fuji Electric recommends users update the product to  Monitouch V-SFT v6.2.3.0 https://felib.fujielectric.co.jp/en/M10009/M20104/document_detail/55ff739b-bd06-4241-b078-3b9c9728bdfd ."
        }
      ],
      "source": {
        "advisory": "ICSA-24-151-02",
        "discovery": "EXTERNAL"
      },
      "title": "Fuji Electric Monitouch V-SFT Stack-Based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-34171",
    "datePublished": "2024-05-30T19:55:23.835Z",
    "dateReserved": "2024-05-20T14:11:06.275Z",
    "dateUpdated": "2024-08-02T02:51:09.599Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11793 (GCVE-0-2024-11793)
Vulnerability from cvelistv5
Published
2024-11-27 23:34
Modified
2024-11-29 16:59
CWE
Summary
Fuji Electric Monitouch V-SFT V9C File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of V9C files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24503.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:monitouch_v-sft:6.2.3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "monitouch_v-sft",
            "vendor": "fujielectric",
            "versions": [
              {
                "status": "affected",
                "version": "6.2.3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11793",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T16:43:24.101858Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T16:59:47.581Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "6.2.3.0"
            }
          ]
        }
      ],
      "dateAssigned": "2024-11-26T10:01:58.448-06:00",
      "datePublic": "2024-11-27T14:58:46.685-06:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric Monitouch V-SFT V9C File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of V9C files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24503."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787: Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-27T23:34:32.078Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1619",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1619/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "kimiya"
      },
      "title": "Fuji Electric Monitouch V-SFT V9C File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-11793",
    "datePublished": "2024-11-27T23:34:32.078Z",
    "dateReserved": "2024-11-26T16:01:58.428Z",
    "dateUpdated": "2024-11-29T16:59:47.581Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11795 (GCVE-0-2024-11795)
Vulnerability from cvelistv5
Published
2024-11-27 23:34
Modified
2024-11-29 16:59
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
Fuji Electric Monitouch V-SFT V8 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of V8 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24505.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:monitouch_v-sft:6.2.3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "monitouch_v-sft",
            "vendor": "fujielectric",
            "versions": [
              {
                "status": "affected",
                "version": "6.2.3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11795",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T16:43:24.101858Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T16:59:47.336Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "6.2.3.0"
            }
          ]
        }
      ],
      "dateAssigned": "2024-11-26T10:02:08.078-06:00",
      "datePublic": "2024-11-27T14:59:24.205-06:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric Monitouch V-SFT V8 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of V8 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24505."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-27T23:34:41.798Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1621",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1621/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "kimiya"
      },
      "title": "Fuji Electric Monitouch V-SFT V8 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-11795",
    "datePublished": "2024-11-27T23:34:41.798Z",
    "dateReserved": "2024-11-26T16:02:08.057Z",
    "dateUpdated": "2024-11-29T16:59:47.336Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-11790 (GCVE-0-2024-11790)
Vulnerability from cvelistv5
Published
2024-11-27 23:34
Modified
2024-11-29 17:09
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
Fuji Electric Monitouch V-SFT V10 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of V10 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24449.
References
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:fujielectric:monitouch_v-sft:6.2.3.0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "monitouch_v-sft",
            "vendor": "fujielectric",
            "versions": [
              {
                "status": "affected",
                "version": "6.2.3.0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11790",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-29T16:43:24.101858Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-29T17:09:49.009Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Monitouch V-SFT",
          "vendor": "Fuji Electric",
          "versions": [
            {
              "status": "affected",
              "version": "6.2.3.0"
            }
          ]
        }
      ],
      "dateAssigned": "2024-11-26T10:01:32.604-06:00",
      "datePublic": "2024-11-27T14:58:07.671-06:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Fuji Electric Monitouch V-SFT V10 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Fuji Electric Monitouch V-SFT. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of V10 files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-24449."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-27T23:34:18.453Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1616",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1616/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "kimiya"
      },
      "title": "Fuji Electric Monitouch V-SFT V10 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-11790",
    "datePublished": "2024-11-27T23:34:18.453Z",
    "dateReserved": "2024-11-26T16:01:32.581Z",
    "dateUpdated": "2024-11-29T17:09:49.009Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}