Vulnerabilites related to FATEK Automation - PLC WinProladder
CVE-2020-16234 (GCVE-0-2020-16234)
Vulnerability from cvelistv5
Published
2020-09-30 20:44
Modified
2024-08-04 13:37
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
In PLC WinProladder Version 3.28 and prior, a stack-based buffer overflow vulnerability can be exploited when a valid user opens a specially crafted file, which may allow an attacker to remotely execute arbitrary code.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
FATEK Automation | PLC WinProladder |
Version: unspecified < |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T13:37:53.800Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-254-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "PLC WinProladder", "vendor": "FATEK Automation", "versions": [ { "lessThanOrEqual": "3.28", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "In PLC WinProladder Version 3.28 and prior, a stack-based buffer overflow vulnerability can be exploited when a valid user opens a specially crafted file, which may allow an attacker to remotely execute arbitrary code." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-09-30T20:44:31", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-254-02" } ], "source": { "advisory": "ICSA-20-254-02", "discovery": "UNKNOWN" }, "title": "FATEK Automation PLC WinProladder", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2020-16234", "STATE": "PUBLIC", "TITLE": "FATEK Automation PLC WinProladder" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "PLC WinProladder", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "3.28" } ] } } ] }, "vendor_name": "FATEK Automation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In PLC WinProladder Version 3.28 and prior, a stack-based buffer overflow vulnerability can be exploited when a valid user opens a specially crafted file, which may allow an attacker to remotely execute arbitrary code." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-121 Stack-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-254-02", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-254-02" } ] }, "source": { "advisory": "ICSA-20-254-02", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-16234", "datePublished": "2020-09-30T20:44:31", "dateReserved": "2020-07-31T00:00:00", "dateUpdated": "2024-08-04T13:37:53.800Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }