Vulnerabilites related to Schneider Electric - ProClima
CVE-2014-9188 (GCVE-0-2014-9188)
Vulnerability from cvelistv5
Published
2014-12-27 15:00
Modified
2025-07-24 22:39
Severity ?
CWE
Summary
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:40:23.200Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ProClima",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThanOrEqual": "6.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This vulnerability was reported to ZDI by security researchers Ariele Caltabiano, Andrea Micalizzi, and Brian Gorenc."
        }
      ],
      "datePublic": "2014-12-10T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eBuffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514.  NOTE: this may be clarified later based on details provided by researchers.\u003c/p\u003e"
            }
          ],
          "value": "Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514.  NOTE: this may be clarified later based on details provided by researchers."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-24T22:39:42.287Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-350-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSchneider Electric has released an updated version of the ProClima \nsoftware, Version 6.1.7, which mitigates these vulnerabilities. \nCustomers are encouraged to download the new version and update their \ninstallations. It is important that customers first uninstall the \ncurrent version. The new version can be downloaded from Schneider \nElectric\u2019s web site at the following location:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.schneider-electric.com/ww/en/download/document/ProClima_software\"\u003ehttp://www.schneider-electric.com/ww/en/download/document/ProClima_software\u003c/a\u003e\u003c/p\u003e\n\u003cp\u003eFor further information on these vulnerabilities, please see \nSchneider Electric\u2019s security notification (SEVD 2014-344-01) at \nSchneider Electric\u2019s cybersecurity web page:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page%20\"\u003ehttp://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Schneider Electric has released an updated version of the ProClima \nsoftware, Version 6.1.7, which mitigates these vulnerabilities. \nCustomers are encouraged to download the new version and update their \ninstallations. It is important that customers first uninstall the \ncurrent version. The new version can be downloaded from Schneider \nElectric\u2019s web site at the following location:\n\n\n http://www.schneider-electric.com/ww/en/download/document/ProClima_software \n\n\nFor further information on these vulnerabilities, please see \nSchneider Electric\u2019s security notification (SEVD 2014-344-01) at \nSchneider Electric\u2019s cybersecurity web page:\n\n\n http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cyber-security-vulnerabilities-sorted.page%20"
        }
      ],
      "source": {
        "advisory": "ICSA-14-350-01",
        "discovery": "EXTERNAL"
      },
      "title": "Schneider Electric ProClima Command Injection",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-9188",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514.  NOTE: this may be clarified later based on details provided by researchers."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01",
              "refsource": "CONFIRM",
              "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-9188",
    "datePublished": "2014-12-27T15:00:00",
    "dateReserved": "2014-12-02T00:00:00",
    "dateUpdated": "2025-07-24T22:39:42.287Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}