Vulnerabilites related to Rockwell Automation - RSLinx Classic
CVE-2018-14827 (GCVE-0-2018-14827)
Vulnerability from cvelistv5
Published
2018-09-20 20:00
Modified
2024-09-16 19:14
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-400 - UNCONTROLLED RESOURCE CONSUMPTION ('RESOURCE EXHAUSTION')
Summary
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. A remote, unauthenticated threat actor may intentionally send specially crafted Ethernet/IP packets to Port 44818, causing the software application to stop responding and crash. The user must restart the software to regain functionality.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Rockwell Automation | RSLinx Classic |
Version: 4.00.01 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T09:38:13.995Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "RSLinx Classic", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "4.00.01 and prior" } ] } ], "datePublic": "2018-09-20T00:00:00", "descriptions": [ { "lang": "en", "value": "Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. A remote, unauthenticated threat actor may intentionally send specially crafted Ethernet/IP packets to Port 44818, causing the software application to stop responding and crash. The user must restart the software to regain functionality." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "UNCONTROLLED RESOURCE CONSUMPTION (\u0027RESOURCE EXHAUSTION\u0027) CWE-400", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-09-20T19:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-09-20T00:00:00", "ID": "CVE-2018-14827", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "RSLinx Classic", "version": { "version_data": [ { "version_value": "4.00.01 and prior" } ] } } ] }, "vendor_name": "Rockwell Automation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. A remote, unauthenticated threat actor may intentionally send specially crafted Ethernet/IP packets to Port 44818, causing the software application to stop responding and crash. The user must restart the software to regain functionality." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "UNCONTROLLED RESOURCE CONSUMPTION (\u0027RESOURCE EXHAUSTION\u0027) CWE-400" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-14827", "datePublished": "2018-09-20T20:00:00Z", "dateReserved": "2018-08-01T00:00:00", "dateUpdated": "2024-09-16T19:14:30.799Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-6553 (GCVE-0-2019-6553)
Vulnerability from cvelistv5
Published
2019-04-04 18:59
Modified
2024-08-04 20:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - STACK-BASED BUFFER OVERFLOW
Summary
A vulnerability was found in Rockwell Automation RSLinx Classic versions 4.10.00 and prior. An input validation issue in a .dll file of RSLinx Classic where the data in a Forward Open service request is passed to a fixed size buffer, allowing an attacker to exploit a stack-based buffer overflow condition.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Rockwell Automation | RSLinx Classic |
Version: 4.10.00 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:21.569Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-064-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "RSLinx Classic", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "4.10.00 and prior" } ] } ], "datePublic": "2019-03-05T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Rockwell Automation RSLinx Classic versions 4.10.00 and prior. An input validation issue in a .dll file of RSLinx Classic where the data in a Forward Open service request is passed to a fixed size buffer, allowing an attacker to exploit a stack-based buffer overflow condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "STACK-BASED BUFFER OVERFLOW CWE-121", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-04-04T18:59:09", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-064-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2019-6553", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "RSLinx Classic", "version": { "version_data": [ { "version_value": "4.10.00 and prior" } ] } } ] }, "vendor_name": "Rockwell Automation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability was found in Rockwell Automation RSLinx Classic versions 4.10.00 and prior. An input validation issue in a .dll file of RSLinx Classic where the data in a Forward Open service request is passed to a fixed size buffer, allowing an attacker to exploit a stack-based buffer overflow condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "STACK-BASED BUFFER OVERFLOW CWE-121" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-064-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-064-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2019-6553", "datePublished": "2019-04-04T18:59:09", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:21.569Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-14821 (GCVE-0-2018-14821)
Vulnerability from cvelistv5
Published
2018-09-20 20:00
Modified
2024-09-17 00:35
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-122 - HEAP-BASED BUFFER OVERFLOW
Summary
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing the RSLinx Classic application to terminate. The user will need to manually restart the software to regain functionality.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Rockwell Automation | RSLinx Classic |
Version: 4.00.01 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T09:38:13.969Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2018-26" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "RSLinx Classic", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "4.00.01 and prior" } ] } ], "datePublic": "2018-09-20T00:00:00", "descriptions": [ { "lang": "en", "value": "Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing the RSLinx Classic application to terminate. The user will need to manually restart the software to regain functionality." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "HEAP-BASED BUFFER OVERFLOW CWE-122", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-09-21T09:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2018-26" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-09-20T00:00:00", "ID": "CVE-2018-14821", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "RSLinx Classic", "version": { "version_data": [ { "version_value": "4.00.01 and prior" } ] } } ] }, "vendor_name": "Rockwell Automation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing the RSLinx Classic application to terminate. The user will need to manually restart the software to regain functionality." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "HEAP-BASED BUFFER OVERFLOW CWE-122" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02" }, { "name": "https://www.tenable.com/security/research/tra-2018-26", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2018-26" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-14821", "datePublished": "2018-09-20T20:00:00Z", "dateReserved": "2018-08-01T00:00:00", "dateUpdated": "2024-09-17T00:35:32.767Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-14829 (GCVE-0-2018-14829)
Vulnerability from cvelistv5
Published
2018-09-20 20:00
Modified
2024-09-16 23:12
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - STACK-BASED BUFFER OVERFLOW
Summary
Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote threat actor to intentionally send a malformed CIP packet to Port 44818, causing the software application to stop responding and crash. This vulnerability also has the potential to exploit a buffer overflow condition, which may allow the threat actor to remotely execute arbitrary code.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Rockwell Automation | RSLinx Classic |
Version: 4.00.01 and prior |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T09:38:13.983Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2018-26" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "RSLinx Classic", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "4.00.01 and prior" } ] } ], "datePublic": "2018-09-20T00:00:00", "descriptions": [ { "lang": "en", "value": "Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote threat actor to intentionally send a malformed CIP packet to Port 44818, causing the software application to stop responding and crash. This vulnerability also has the potential to exploit a buffer overflow condition, which may allow the threat actor to remotely execute arbitrary code." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "STACK-BASED BUFFER OVERFLOW CWE-121", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-09-21T09:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2018-26" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-09-20T00:00:00", "ID": "CVE-2018-14829", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "RSLinx Classic", "version": { "version_data": [ { "version_value": "4.00.01 and prior" } ] } } ] }, "vendor_name": "Rockwell Automation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote threat actor to intentionally send a malformed CIP packet to Port 44818, causing the software application to stop responding and crash. This vulnerability also has the potential to exploit a buffer overflow condition, which may allow the threat actor to remotely execute arbitrary code." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "STACK-BASED BUFFER OVERFLOW CWE-121" } ] } ] }, "references": { "reference_data": [ { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-263-02" }, { "name": "https://www.tenable.com/security/research/tra-2018-26", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2018-26" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-14829", "datePublished": "2018-09-20T20:00:00Z", "dateReserved": "2018-08-01T00:00:00", "dateUpdated": "2024-09-16T23:12:03.232Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }