Vulnerabilites related to ABB - Relion protection relays - REX640 PCL3
CVE-2021-22283 (GCVE-0-2021-22283)
Vulnerability from cvelistv5
Published
2023-02-28 04:21
Modified
2025-03-07 18:12
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-665 - Improper Initialization
Summary
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.
References
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | ABB | Relion protection relays - 611 series |
Version: 1.0.0 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:37:18.488Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2021-22283", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-07T18:11:58.860932Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-07T18:12:14.516Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Relion protection relays - 611 series", "vendor": "ABB", "versions": [ { "lessThan": "2.0.3", "status": "affected", "version": "1.0.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - 615 series IEC 4.0 FP1", "vendor": "ABB", "versions": [ { "lessThan": " 4.1.9", "status": "affected", "version": "4.1.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - 615 series CN 4.0 FP1", "vendor": "ABB", "versions": [ { "lessThan": "4.1.8", "status": "affected", "version": "4.1.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - 615 series IEC 5.0", "vendor": "ABB", "versions": [ { "lessThan": "5.0.12", "status": "affected", "version": "5.0.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - 615 series IEC 5.0 FP1", "vendor": "ABB", "versions": [ { "lessThan": "5.1.20", "status": "affected", "version": "5.1.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - 620 series IEC/CN 2.0", "vendor": "ABB", "versions": [ { "lessThan": "2.0.11", "status": "affected", "version": "2.0.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - 620 series IEC/CN 2.0 FP1", "vendor": "ABB", "versions": [ { "lessThan": "2.1.15", "status": "affected", "version": "2.1.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - REX640 PCL1", "vendor": "ABB", "versions": [ { "lessThan": "1.0.8", "status": "affected", "version": "1.0.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - REX640 PCL2", "vendor": "ABB", "versions": [ { "lessThan": "1.1.4", "status": "affected", "version": "1.1.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - REX640 PCL3", "vendor": "ABB", "versions": [ { "lessThan": "1.2.1", "status": "affected", "version": "1.2.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - RER615", "vendor": "ABB", "versions": [ { "lessThan": "2.0.3", "status": "affected", "version": "2.0.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Remote Monitoring and Control - REC615", "vendor": "ABB", "versions": [ { "lessThan": "2.0.3", "status": "affected", "version": "1.0.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Merging Unit- SMU615", "vendor": "ABB", "versions": [ { "lessThan": "1.0.2", "status": "affected", "version": "1.0.0", "versionType": "firmware" } ] } ], "datePublic": "2022-12-18T18:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.\u003cp\u003eThis issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.\u003c/p\u003e" } ], "value": "Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.\n\n" } ], "impacts": [ { "capecId": "CAPEC-216", "descriptions": [ { "lang": "en", "value": "CAPEC-216 Communication Channel Manipulation" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-665", "description": "CWE-665 Improper Initialization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-28T04:21:41.776Z", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "references": [ { "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "source": { "discovery": "UNKNOWN" }, "title": "MMS File Transfer Vulnerability impact on Distribution Automation products", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2021-22283", "datePublished": "2023-02-28T04:21:41.776Z", "dateReserved": "2021-01-05T17:31:49.081Z", "dateUpdated": "2025-03-07T18:12:14.516Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }