Vulnerabilites related to Synology - Replication Service
CVE-2024-10442 (GCVE-0-2024-10442)
Vulnerability from cvelistv5
Published
2025-03-19 02:14
Modified
2025-03-19 14:13
Severity ?
CWE
Summary
Off-by-one error vulnerability in the transmission component in Synology Replication Service before 1.0.12-0066, 1.2.2-0353 and 1.3.0-0423 and Synology Unified Controller (DSMUC) before 3.1.4-23079 allows remote attackers to execute arbitrary code, potentially leading to a broader impact across the system via unspecified vectors.
Impacted products
Vendor Product Version
Synology Unified Controller (DSMUC) Version: 3.1   
Create a notification for this product.
   Synology Replication Service Version: *   
Version: *   
Version: *   
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-10442",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-19T14:05:08.214212Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-19T14:13:16.719Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Unified Controller (DSMUC)",
          "vendor": "Synology",
          "versions": [
            {
              "lessThan": "3.1.4-23079",
              "status": "affected",
              "version": "3.1",
              "versionType": "semver"
            },
            {
              "lessThan": "3.1",
              "status": "unknown",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "Replication Service",
          "vendor": "Synology",
          "versions": [
            {
              "lessThan": "1.2.2-0353",
              "status": "affected",
              "version": "*",
              "versionType": "semver"
            },
            {
              "lessThan": "1.0.12-0066",
              "status": "affected",
              "version": "*",
              "versionType": "semver"
            },
            {
              "lessThan": "1.3.0-0423",
              "status": "affected",
              "version": "*",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Jack Dates | RET2 Systems jack@ret2.io"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Off-by-one error vulnerability in the transmission component in Synology Replication Service before 1.0.12-0066, 1.2.2-0353 and 1.3.0-0423 and Synology Unified Controller (DSMUC) before 3.1.4-23079 allows remote attackers to execute arbitrary code, potentially leading to a broader impact across the system via unspecified vectors."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-193",
              "description": "Off-by-one Error",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-19T02:14:03.691Z",
        "orgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
        "shortName": "synology"
      },
      "references": [
        {
          "name": "Synology-SA-24:22 Replication Service (PWN2OWN 2024)",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.synology.com/en-global/security/advisory/Synology_SA_24_22"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "db201096-a0cc-46c7-9a55-61d9e221bf01",
    "assignerShortName": "synology",
    "cveId": "CVE-2024-10442",
    "datePublished": "2025-03-19T02:14:03.691Z",
    "dateReserved": "2024-10-28T02:29:33.711Z",
    "dateUpdated": "2025-03-19T14:13:16.719Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}