Vulnerabilites related to Siemens - SCALANCE S623
CVE-2019-13924 (GCVE-0-2019-13924)
Vulnerability from cvelistv5
Published
2020-02-11 00:00
Modified
2024-08-05 00:05
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-693 - Protection Mechanism Failure
Summary
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens | SCALANCE S602 |
Version: All versions < V4.1 |
||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T00:05:43.919Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf" }, { "tags": [ "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE S602", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE S612", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE S623", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE S627-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1" } ] }, { "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 5.2.4" } ] }, { "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X-200RNA switch family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.7" } ] }, { "product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 4.1.3" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003c V4.1), SCALANCE S612 (All versions \u003c V4.1), SCALANCE S623 (All versions \u003c V4.1), SCALANCE S627-2M (All versions \u003c V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-693", "description": "CWE-693: Protection Mechanism Failure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-13T00:00:00", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-951513.pdf" }, { "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-07" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-13924", "datePublished": "2020-02-11T00:00:00", "dateReserved": "2019-07-18T00:00:00", "dateUpdated": "2024-08-05T00:05:43.919Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-6585 (GCVE-0-2019-6585)
Vulnerability from cvelistv5
Published
2020-03-10 19:16
Modified
2024-08-04 20:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Summary
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens | SCALANCE S602 |
Version: All versions >= V3.0 and < V4.1 |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.461Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE S602", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V3.0 and \u003c V4.1" } ] }, { "product": "SCALANCE S612", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V3.0 and \u003c V4.1" } ] }, { "product": "SCALANCE S623", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V3.0 and \u003c V4.1" } ] }, { "product": "SCALANCE S627-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V3.0 and \u003c V4.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-80", "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-04-22T20:42:19", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6585", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE S602", "version": { "version_data": [ { "version_value": "All versions \u003e= V3.0 and \u003c V4.1" } ] } }, { "product_name": "SCALANCE S612", "version": { "version_data": [ { "version_value": "All versions \u003e= V3.0 and \u003c V4.1" } ] } }, { "product_name": "SCALANCE S623", "version": { "version_data": [ { "version_value": "All versions \u003e= V3.0 and \u003c V4.1" } ] } }, { "product_name": "SCALANCE S627-2M", "version": { "version_data": [ { "version_value": "All versions \u003e= V3.0 and \u003c V4.1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6585", "datePublished": "2020-03-10T19:16:17", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.461Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-13925 (GCVE-0-2019-13925)
Vulnerability from cvelistv5
Published
2020-02-11 15:36
Modified
2024-08-05 00:05
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Summary
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens | SCALANCE S602 |
Version: All versions >= V3.0 and < V4.1 |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T00:05:43.784Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE S602", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V3.0 and \u003c V4.1" } ] }, { "product": "SCALANCE S612", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V3.0 and \u003c V4.1" } ] }, { "product": "SCALANCE S623", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V3.0 and \u003c V4.1" } ] }, { "product": "SCALANCE S627-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V3.0 and \u003c V4.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-04-22T20:42:18", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-13925", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE S602", "version": { "version_data": [ { "version_value": "All versions \u003e= V3.0 and \u003c V4.1" } ] } }, { "product_name": "SCALANCE S612", "version": { "version_data": [ { "version_value": "All versions \u003e= V3.0 and \u003c V4.1" } ] } }, { "product_name": "SCALANCE S623", "version": { "version_data": [ { "version_value": "All versions \u003e= V3.0 and \u003c V4.1" } ] } }, { "product_name": "SCALANCE S627-2M", "version": { "version_data": [ { "version_value": "All versions \u003e= V3.0 and \u003c V4.1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-13925", "datePublished": "2020-02-11T15:36:10", "dateReserved": "2019-07-18T00:00:00", "dateUpdated": "2024-08-05T00:05:43.784Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-13926 (GCVE-0-2019-13926)
Vulnerability from cvelistv5
Published
2020-02-11 15:36
Modified
2024-08-05 00:05
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-400 - Uncontrolled Resource Consumption
Summary
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens | SCALANCE S602 |
Version: All versions >= V3.0 and < V4.1 |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T00:05:43.805Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE S602", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V3.0 and \u003c V4.1" } ] }, { "product": "SCALANCE S612", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V3.0 and \u003c V4.1" } ] }, { "product": "SCALANCE S623", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V3.0 and \u003c V4.1" } ] }, { "product": "SCALANCE S627-2M", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V3.0 and \u003c V4.1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-04-22T20:42:18", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-13926", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE S602", "version": { "version_data": [ { "version_value": "All versions \u003e= V3.0 and \u003c V4.1" } ] } }, { "product_name": "SCALANCE S612", "version": { "version_data": [ { "version_value": "All versions \u003e= V3.0 and \u003c V4.1" } ] } }, { "product_name": "SCALANCE S623", "version": { "version_data": [ { "version_value": "All versions \u003e= V3.0 and \u003c V4.1" } ] } }, { "product_name": "SCALANCE S627-2M", "version": { "version_data": [ { "version_value": "All versions \u003e= V3.0 and \u003c V4.1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE S602 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S612 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S623 (All versions \u003e= V3.0 and \u003c V4.1), SCALANCE S627-2M (All versions \u003e= V3.0 and \u003c V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-591405.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-20-042-10" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-13926", "datePublished": "2020-02-11T15:36:10", "dateReserved": "2019-07-18T00:00:00", "dateUpdated": "2024-08-05T00:05:43.805Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }