Vulnerabilites related to Siemens - SENTRON 7KM PAC3120 AC/DC
CVE-2024-21483 (GCVE-0-2024-21483)
Vulnerability from cvelistv5
Published
2024-03-12 10:21
Modified
2025-04-15 15:27
Severity ?
4.6 (Medium) - CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
5.1 (Medium) - CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
5.1 (Medium) - CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
- CWE-284 - Improper Access Control
Summary
A vulnerability has been identified in SENTRON 7KM PAC3120 AC/DC (7KM3120-0BA01-1DA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3120 DC (7KM3120-1BA01-1EA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 AC/DC (7KM3220-0BA01-1DA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 DC (7KM3220-1BA01-1EA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)). The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process.
An attacker with physical access to the device could read out the data.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens | SENTRON 7KM PAC3120 AC/DC |
Version: V3.2.3 < V3.2.4 |
||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-21483", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-03-12T16:21:33.826248Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-04-15T15:27:19.384Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T22:20:40.584Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-792319.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SENTRON 7KM PAC3120 AC/DC", "vendor": "Siemens", "versions": [ { "lessThan": "V3.2.4", "status": "affected", "version": "V3.2.3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SENTRON 7KM PAC3120 DC", "vendor": "Siemens", "versions": [ { "lessThan": "V3.2.4", "status": "affected", "version": "V3.2.3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SENTRON 7KM PAC3220 AC/DC", "vendor": "Siemens", "versions": [ { "lessThan": "V3.2.4", "status": "affected", "version": "V3.2.3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SENTRON 7KM PAC3220 DC", "vendor": "Siemens", "versions": [ { "lessThan": "V3.2.4", "status": "affected", "version": "V3.2.3", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SENTRON 7KM PAC3120 AC/DC (7KM3120-0BA01-1DA0) (All versions \u003e= V3.2.3 \u003c V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3120 DC (7KM3120-1BA01-1EA0) (All versions \u003e= V3.2.3 \u003c V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 AC/DC (7KM3220-0BA01-1DA0) (All versions \u003e= V3.2.3 \u003c V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 DC (7KM3220-1BA01-1EA0) (All versions \u003e= V3.2.3 \u003c V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)). The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process.\r\n\r\nAn attacker with physical access to the device could read out the data." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 5.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284: Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:36:27.347Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-792319.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-21483", "datePublished": "2024-03-12T10:21:52.434Z", "dateReserved": "2023-12-20T13:17:31.508Z", "dateUpdated": "2025-04-15T15:27:19.384Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }