CVE-2018-4855 (GCVE-0-2018-4855)
Vulnerability from cvelistv5
Published
2018-07-03 14:00
Modified
2024-09-17 03:08
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-311 - Missing Encryption of Sensitive Data
Summary
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). Unencrypted storage of passwords in the client configuration files and during network transmission could allow an attacker in a privileged position to obtain access passwords.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens AG | SICLOCK TC100, SICLOCK TC400 |
Version: SICLOCK TC100 : All versions Version: SICLOCK TC400 : All versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:18:26.644Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "104672", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/104672" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICLOCK TC100, SICLOCK TC400", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "SICLOCK TC100 : All versions" }, { "status": "affected", "version": "SICLOCK TC400 : All versions" } ] } ], "datePublic": "2018-07-03T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). Unencrypted storage of passwords in the client configuration files and during network transmission could allow an attacker in a privileged position to obtain access passwords." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-311", "description": "CWE-311: Missing Encryption of Sensitive Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-07-06T09:57:01", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "104672", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/104672" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "DATE_PUBLIC": "2018-07-03T00:00:00", "ID": "CVE-2018-4855", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICLOCK TC100, SICLOCK TC400", "version": { "version_data": [ { "version_value": "SICLOCK TC100 : All versions" }, { "version_value": "SICLOCK TC400 : All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). Unencrypted storage of passwords in the client configuration files and during network transmission could allow an attacker in a privileged position to obtain access passwords." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-311: Missing Encryption of Sensitive Data" } ] } ] }, "references": { "reference_data": [ { "name": "104672", "refsource": "BID", "url": "http://www.securityfocus.com/bid/104672" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-4855", "datePublished": "2018-07-03T14:00:00Z", "dateReserved": "2018-01-02T00:00:00", "dateUpdated": "2024-09-17T03:08:21.334Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-4851 (GCVE-0-2018-4851)
Vulnerability from cvelistv5
Published
2018-07-03 14:00
Modified
2024-09-17 01:01
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-399 - Resource Management Errors
Summary
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could cause a Denial-of-Service condition by sending certain packets to the device, causing potential reboots of the device. The core functionality of the device could be impacted. The time serving functionality recovers when time synchronization with GPS devices or other NTP servers are completed.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens AG | SICLOCK TC100, SICLOCK TC400 |
Version: SICLOCK TC100 : All versions Version: SICLOCK TC400 : All versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:18:26.689Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "104672", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/104672" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICLOCK TC100, SICLOCK TC400", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "SICLOCK TC100 : All versions" }, { "status": "affected", "version": "SICLOCK TC400 : All versions" } ] } ], "datePublic": "2018-07-03T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could cause a Denial-of-Service condition by sending certain packets to the device, causing potential reboots of the device. The core functionality of the device could be impacted. The time serving functionality recovers when time synchronization with GPS devices or other NTP servers are completed." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-399", "description": "CWE-399: Resource Management Errors", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-07-06T09:57:01", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "104672", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/104672" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "DATE_PUBLIC": "2018-07-03T00:00:00", "ID": "CVE-2018-4851", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICLOCK TC100, SICLOCK TC400", "version": { "version_data": [ { "version_value": "SICLOCK TC100 : All versions" }, { "version_value": "SICLOCK TC400 : All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could cause a Denial-of-Service condition by sending certain packets to the device, causing potential reboots of the device. The core functionality of the device could be impacted. The time serving functionality recovers when time synchronization with GPS devices or other NTP servers are completed." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-399: Resource Management Errors" } ] } ] }, "references": { "reference_data": [ { "name": "104672", "refsource": "BID", "url": "http://www.securityfocus.com/bid/104672" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-4851", "datePublished": "2018-07-03T14:00:00Z", "dateReserved": "2018-01-02T00:00:00", "dateUpdated": "2024-09-17T01:01:16.624Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-4853 (GCVE-0-2018-4853)
Vulnerability from cvelistv5
Published
2018-07-03 14:00
Modified
2024-09-16 17:32
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the firmware of the device.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens AG | SICLOCK TC100, SICLOCK TC400 |
Version: SICLOCK TC100 : All versions Version: SICLOCK TC400 : All versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:18:26.490Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "104672", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/104672" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICLOCK TC100, SICLOCK TC400", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "SICLOCK TC100 : All versions" }, { "status": "affected", "version": "SICLOCK TC400 : All versions" } ] } ], "datePublic": "2018-07-03T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the firmware of the device." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-07-06T09:57:01", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "104672", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/104672" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "DATE_PUBLIC": "2018-07-03T00:00:00", "ID": "CVE-2018-4853", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICLOCK TC100, SICLOCK TC400", "version": { "version_data": [ { "version_value": "SICLOCK TC100 : All versions" }, { "version_value": "SICLOCK TC400 : All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the firmware of the device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "104672", "refsource": "BID", "url": "http://www.securityfocus.com/bid/104672" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-4853", "datePublished": "2018-07-03T14:00:00Z", "dateReserved": "2018-01-02T00:00:00", "dateUpdated": "2024-09-16T17:32:52.281Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-4852 (GCVE-0-2018-4852)
Vulnerability from cvelistv5
Published
2018-07-03 14:00
Modified
2024-09-17 03:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-288 - Authentication Bypass Using an Alternate Path or Channel
Summary
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could potentially circumvent the authentication mechanism if he/she is able to obtain certain knowledge specific to the attacked device.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens AG | SICLOCK TC100, SICLOCK TC400 |
Version: SICLOCK TC100 : All versions Version: SICLOCK TC400 : All versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:18:26.602Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "104672", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/104672" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICLOCK TC100, SICLOCK TC400", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "SICLOCK TC100 : All versions" }, { "status": "affected", "version": "SICLOCK TC400 : All versions" } ] } ], "datePublic": "2018-07-03T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could potentially circumvent the authentication mechanism if he/she is able to obtain certain knowledge specific to the attacked device." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-288", "description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-07-06T09:57:01", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "104672", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/104672" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "DATE_PUBLIC": "2018-07-03T00:00:00", "ID": "CVE-2018-4852", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICLOCK TC100, SICLOCK TC400", "version": { "version_data": [ { "version_value": "SICLOCK TC100 : All versions" }, { "version_value": "SICLOCK TC400 : All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to the device could potentially circumvent the authentication mechanism if he/she is able to obtain certain knowledge specific to the attacked device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-288: Authentication Bypass Using an Alternate Path or Channel" } ] } ] }, "references": { "reference_data": [ { "name": "104672", "refsource": "BID", "url": "http://www.securityfocus.com/bid/104672" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-4852", "datePublished": "2018-07-03T14:00:00Z", "dateReserved": "2018-01-02T00:00:00", "dateUpdated": "2024-09-17T03:07:34.425Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-4856 (GCVE-0-2018-4856)
Vulnerability from cvelistv5
Published
2018-07-03 14:00
Modified
2024-09-17 03:28
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-287 - Improper Authentication
Summary
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with administrative access to the device's management interface could lock out legitimate users. Manual interaction is required to restore the access of legitimate users.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens AG | SICLOCK TC100, SICLOCK TC400 |
Version: SICLOCK TC100 : All versions Version: SICLOCK TC400 : All versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:18:26.641Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "104672", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/104672" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICLOCK TC100, SICLOCK TC400", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "SICLOCK TC100 : All versions" }, { "status": "affected", "version": "SICLOCK TC400 : All versions" } ] } ], "datePublic": "2018-07-03T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with administrative access to the device\u0027s management interface could lock out legitimate users. Manual interaction is required to restore the access of legitimate users." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287: Improper Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-07-06T09:57:01", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "104672", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/104672" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "DATE_PUBLIC": "2018-07-03T00:00:00", "ID": "CVE-2018-4856", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICLOCK TC100, SICLOCK TC400", "version": { "version_data": [ { "version_value": "SICLOCK TC100 : All versions" }, { "version_value": "SICLOCK TC400 : All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with administrative access to the device\u0027s management interface could lock out legitimate users. Manual interaction is required to restore the access of legitimate users." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-287: Improper Authentication" } ] } ] }, "references": { "reference_data": [ { "name": "104672", "refsource": "BID", "url": "http://www.securityfocus.com/bid/104672" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-4856", "datePublished": "2018-07-03T14:00:00Z", "dateReserved": "2018-01-02T00:00:00", "dateUpdated": "2024-09-17T03:28:51.189Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-4854 (GCVE-0-2018-4854)
Vulnerability from cvelistv5
Published
2018-07-03 14:00
Modified
2024-09-16 16:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-306 - Missing Authentication for Critical Function
Summary
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the administrative client stored on the device. If a legitimate user downloads and executes the modified client from the affected device, then he/she could obtain code execution on the client system.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens AG | SICLOCK TC100, SICLOCK TC400 |
Version: SICLOCK TC100 : All versions Version: SICLOCK TC400 : All versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:18:26.578Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "104672", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/104672" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SICLOCK TC100, SICLOCK TC400", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "SICLOCK TC100 : All versions" }, { "status": "affected", "version": "SICLOCK TC400 : All versions" } ] } ], "datePublic": "2018-07-03T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the administrative client stored on the device. If a legitimate user downloads and executes the modified client from the affected device, then he/she could obtain code execution on the client system." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-07-06T09:57:01", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "104672", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/104672" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "DATE_PUBLIC": "2018-07-03T00:00:00", "ID": "CVE-2018-4854", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SICLOCK TC100, SICLOCK TC400", "version": { "version_data": [ { "version_value": "SICLOCK TC100 : All versions" }, { "version_value": "SICLOCK TC400 : All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the administrative client stored on the device. If a legitimate user downloads and executes the modified client from the affected device, then he/she could obtain code execution on the client system." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "104672", "refsource": "BID", "url": "http://www.securityfocus.com/bid/104672" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-4854", "datePublished": "2018-07-03T14:00:00Z", "dateReserved": "2018-01-02T00:00:00", "dateUpdated": "2024-09-16T16:18:48.786Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }