Vulnerabilites related to Siemens - SINAMICS S200
CVE-2024-56336 (GCVE-0-2024-56336)
Vulnerability from cvelistv5
Published
2025-03-11 09:48
Modified
2025-03-11 14:03
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.5 (Critical) - CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
9.5 (Critical) - CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-287 - Improper Authentication
Summary
A vulnerability has been identified in SINAMICS S200 (All versions with serial number beginning with SZVS8, SZVS9, SZVS0 or SZVSN and the FS number is 02). The affected device contains an unlocked bootloader. This security oversight enables attackers to inject malicious code, or install untrusted firmware. The intrinsic security features designed to protect against data manipulation and unauthorized access are compromised when the bootloader is not secured.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Siemens | SINAMICS S200 |
Version: 0 < * |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-56336", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-11T14:02:50.112336Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-11T14:03:17.592Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SINAMICS S200", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINAMICS S200 (All versions with serial number beginning with SZVS8, SZVS9, SZVS0 or SZVSN and the FS number is 02). The affected device contains an unlocked bootloader. This security oversight enables attackers to inject malicious code, or install untrusted firmware. The intrinsic security features designed to protect against data manipulation and unauthorized access are compromised when the bootloader is not secured." } ], "metrics": [ { "cvssV3_1": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 9.5, "baseSeverity": "CRITICAL", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287: Improper Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-11T09:48:06.756Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-787280.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-56336", "datePublished": "2025-03-11T09:48:06.756Z", "dateReserved": "2024-12-20T09:08:00.430Z", "dateUpdated": "2025-03-11T14:03:17.592Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }