Vulnerabilites related to Siemens - Siveillance Control Pro
CVE-2021-31891 (GCVE-0-2021-31891)
Vulnerability from cvelistv5
Published
2021-09-14 10:47
Modified
2024-08-03 23:10
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Summary
A vulnerability has been identified in Desigo CC (All versions with OIS Extension Module), GMA-Manager (All versions with OIS running on Debian 9 or earlier), Operation Scheduler (All versions with OIS running on Debian 9 or earlier), Siveillance Control (All versions with OIS running on Debian 9 or earlier), Siveillance Control Pro (All versions). The affected application incorrectly neutralizes special elements in a specific HTTP GET request which could lead to command injection. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the system with root privileges.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens | Desigo CC |
Version: All versions with OIS Extension Module |
|||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T23:10:30.639Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-535380.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Desigo CC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions with OIS Extension Module" } ] }, { "product": "GMA-Manager", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions with OIS running on Debian 9 or earlier" } ] }, { "product": "Operation Scheduler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions with OIS running on Debian 9 or earlier" } ] }, { "product": "Siveillance Control", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions with OIS running on Debian 9 or earlier" } ] }, { "product": "Siveillance Control Pro", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Desigo CC (All versions with OIS Extension Module), GMA-Manager (All versions with OIS running on Debian 9 or earlier), Operation Scheduler (All versions with OIS running on Debian 9 or earlier), Siveillance Control (All versions with OIS running on Debian 9 or earlier), Siveillance Control Pro (All versions). The affected application incorrectly neutralizes special elements in a specific HTTP GET request which could lead to command injection. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the system with root privileges." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-14T10:47:31", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-535380.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31891", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Desigo CC", "version": { "version_data": [ { "version_value": "All versions with OIS Extension Module" } ] } }, { "product_name": "GMA-Manager", "version": { "version_data": [ { "version_value": "All versions with OIS running on Debian 9 or earlier" } ] } }, { "product_name": "Operation Scheduler", "version": { "version_data": [ { "version_value": "All versions with OIS running on Debian 9 or earlier" } ] } }, { "product_name": "Siveillance Control", "version": { "version_data": [ { "version_value": "All versions with OIS running on Debian 9 or earlier" } ] } }, { "product_name": "Siveillance Control Pro", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Desigo CC (All versions with OIS Extension Module), GMA-Manager (All versions with OIS running on Debian 9 or earlier), Operation Scheduler (All versions with OIS running on Debian 9 or earlier), Siveillance Control (All versions with OIS running on Debian 9 or earlier), Siveillance Control Pro (All versions). The affected application incorrectly neutralizes special elements in a specific HTTP GET request which could lead to command injection. An unauthenticated remote attacker could exploit this vulnerability to execute arbitrary code on the system with root privileges." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-535380.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-535380.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31891", "datePublished": "2021-09-14T10:47:31", "dateReserved": "2021-04-29T00:00:00", "dateUpdated": "2024-08-03T23:10:30.639Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }