CVE-2019-6580 (GCVE-0-2019-6580)
Vulnerability from cvelistv5
Published
2019-06-12 13:47
Modified
2024-08-04 20:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-862 - Missing Authorization
Summary
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change device properties without authorization. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | Siveillance VMS 2017 R2 |
Version: All versions < V11.2a |
|||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.107Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Siveillance VMS 2017 R2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V11.2a" } ] }, { "product": "Siveillance VMS 2018 R1", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.1a" } ] }, { "product": "Siveillance VMS 2018 R2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.2a" } ] }, { "product": "Siveillance VMS 2018 R3", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.3a" } ] }, { "product": "Siveillance VMS 2019 R1", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V13.1a" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP could change device properties without authorization. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-862", "description": "CWE-862: Missing Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-06-14T14:06:47", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6580", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Siveillance VMS 2017 R2", "version": { "version_data": [ { "version_value": "All versions \u003c V11.2a" } ] } }, { "product_name": "Siveillance VMS 2018 R1", "version": { "version_data": [ { "version_value": "All versions \u003c V12.1a" } ] } }, { "product_name": "Siveillance VMS 2018 R2", "version": { "version_data": [ { "version_value": "All versions \u003c V12.2a" } ] } }, { "product_name": "Siveillance VMS 2018 R3", "version": { "version_data": [ { "version_value": "All versions \u003c V12.3a" } ] } }, { "product_name": "Siveillance VMS 2019 R1", "version": { "version_data": [ { "version_value": "All versions \u003c V13.1a" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP could change device properties without authorization. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-862: Missing Authorization" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6580", "datePublished": "2019-06-12T13:47:57", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.107Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-6582 (GCVE-0-2019-6582)
Vulnerability from cvelistv5
Published
2019-06-12 13:47
Modified
2024-08-04 20:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-285 - Improper Authorization
Summary
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP can change user-defined event properties without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises integrity of the user-defined event properties and the availability of corresponding functionality. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | Siveillance VMS 2017 R2 |
Version: All versions < V11.2a |
|||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.276Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Siveillance VMS 2017 R2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V11.2a" } ] }, { "product": "Siveillance VMS 2018 R1", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.1a" } ] }, { "product": "Siveillance VMS 2018 R2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.2a" } ] }, { "product": "Siveillance VMS 2018 R3", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.3a" } ] }, { "product": "Siveillance VMS 2019 R1", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V13.1a" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP can change user-defined event properties without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises integrity of the user-defined event properties and the availability of corresponding functionality. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-285", "description": "CWE-285: Improper Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-06-14T14:07:32", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6582", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Siveillance VMS 2017 R2", "version": { "version_data": [ { "version_value": "All versions \u003c V11.2a" } ] } }, { "product_name": "Siveillance VMS 2018 R1", "version": { "version_data": [ { "version_value": "All versions \u003c V12.1a" } ] } }, { "product_name": "Siveillance VMS 2018 R2", "version": { "version_data": [ { "version_value": "All versions \u003c V12.2a" } ] } }, { "product_name": "Siveillance VMS 2018 R3", "version": { "version_data": [ { "version_value": "All versions \u003c V12.3a" } ] } }, { "product_name": "Siveillance VMS 2019 R1", "version": { "version_data": [ { "version_value": "All versions \u003c V13.1a" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP can change user-defined event properties without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises integrity of the user-defined event properties and the availability of corresponding functionality. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-285: Improper Authorization" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6582", "datePublished": "2019-06-12T13:47:57", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.276Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-6581 (GCVE-0-2019-6581)
Vulnerability from cvelistv5
Published
2019-06-12 13:47
Modified
2024-08-04 20:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-285 - Improper Authorization
Summary
A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions < V11.2a), Siveillance VMS 2018 R1 (All versions < V12.1a), Siveillance VMS 2018 R2 (All versions < V12.2a), Siveillance VMS 2018 R3 (All versions < V12.3a), Siveillance VMS 2019 R1 (All versions < V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens AG | Siveillance VMS 2017 R2 |
Version: All versions < V11.2a |
|||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.105Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Siveillance VMS 2017 R2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V11.2a" } ] }, { "product": "Siveillance VMS 2018 R1", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.1a" } ] }, { "product": "Siveillance VMS 2018 R2", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.2a" } ] }, { "product": "Siveillance VMS 2018 R3", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V12.3a" } ] }, { "product": "Siveillance VMS 2019 R1", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V13.1a" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-285", "description": "CWE-285: Improper Authorization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-06-14T14:07:04", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6581", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Siveillance VMS 2017 R2", "version": { "version_data": [ { "version_value": "All versions \u003c V11.2a" } ] } }, { "product_name": "Siveillance VMS 2018 R1", "version": { "version_data": [ { "version_value": "All versions \u003c V12.1a" } ] } }, { "product_name": "Siveillance VMS 2018 R2", "version": { "version_data": [ { "version_value": "All versions \u003c V12.2a" } ] } }, { "product_name": "Siveillance VMS 2018 R3", "version": { "version_data": [ { "version_value": "All versions \u003c V12.3a" } ] } }, { "product_name": "Siveillance VMS 2019 R1", "version": { "version_data": [ { "version_value": "All versions \u003c V13.1a" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP could change user roles without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises confidentiality, integrity and availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-285: Improper Authorization" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-212009.pdf" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-162-01" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6581", "datePublished": "2019-06-12T13:47:57", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.105Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }