Vulnerabilites related to Bosch - Smart Home Controller
CVE-2019-11894 (GCVE-0-2019-11894)
Vulnerability from cvelistv5
Published
2019-05-29 20:03
Modified
2024-09-17 00:46
CWE
  • CWE-284 - Improper Access Control
Summary
A potential improper access control vulnerability exists in the backup mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in unauthorized download of a backup. In order to exploit the vulnerability, the adversary needs to download the backup directly after a backup triggered by a legitimate user has been completed.
References
Impacted products
Vendor Product Version
Bosch Smart Home Controller Version: unspecified   < 9.8.905
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.566Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Smart Home Controller",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThan": "9.8.905",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Philip Kazmeier"
        }
      ],
      "datePublic": "2019-05-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential improper access control vulnerability exists in the backup mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in unauthorized download of a backup. In order to exploit the vulnerability, the adversary needs to download the backup directly after a backup triggered by a legitimate user has been completed."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-29T20:03:48",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper access control in the backup mechanism of the Bosch Smart Home Controller (SHC)",
      "x_generator": {
        "engine": "Vulnogram 0.0.6"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2019-05-29T12:00:00.000Z",
          "ID": "CVE-2019-11894",
          "STATE": "PUBLIC",
          "TITLE": "Improper access control in the backup mechanism of the Bosch Smart Home Controller (SHC)"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Smart Home Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.8.905"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Philip Kazmeier"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential improper access control vulnerability exists in the backup mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in unauthorized download of a backup. In order to exploit the vulnerability, the adversary needs to download the backup directly after a backup triggered by a legitimate user has been completed."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.6"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2019-11894",
    "datePublished": "2019-05-29T20:03:48.103119Z",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-09-17T00:46:00.989Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-11892 (GCVE-0-2019-11892)
Vulnerability from cvelistv5
Published
2019-05-29 19:55
Modified
2024-09-16 17:42
CWE
  • CWE-284 - Improper Access Control
Summary
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in reading or modification of the SHC's configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction.
References
Impacted products
Vendor Product Version
Bosch Smart Home Controller Version: unspecified   < 9.8.905
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.471Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Smart Home Controller",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThan": "9.8.905",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Philip Kazmeier"
        }
      ],
      "datePublic": "2019-05-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in reading or modification of the SHC\u0027s configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-29T19:55:13",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)",
      "x_generator": {
        "engine": "Vulnogram 0.0.6"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2019-05-29T12:00:00.000Z",
          "ID": "CVE-2019-11892",
          "STATE": "PUBLIC",
          "TITLE": "Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Smart Home Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.8.905"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Philip Kazmeier"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in reading or modification of the SHC\u0027s configuration or triggering and restoring backups. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.6"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2019-11892",
    "datePublished": "2019-05-29T19:55:13.289812Z",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-09-16T17:42:58.052Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-11896 (GCVE-0-2019-11896)
Vulnerability from cvelistv5
Published
2019-05-29 20:11
Modified
2024-09-16 19:24
CWE
  • CWE-284 - Improper Access Control
Summary
A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app, which requires user interaction.
References
Impacted products
Vendor Product Version
Bosch Smart Home Controller Version: unspecified   < 9.8.907
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.437Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Smart Home Controller",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThan": "9.8.907",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Philip Kazmeier"
        }
      ],
      "datePublic": "2019-05-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app, which requires user interaction."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-29T20:11:00",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Incorrect pviilege assignment in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC)",
      "x_generator": {
        "engine": "Vulnogram 0.0.6"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2019-05-29T12:00:00.000Z",
          "ID": "CVE-2019-11896",
          "STATE": "PUBLIC",
          "TITLE": "Incorrect pviilege assignment in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC)"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Smart Home Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.8.907"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Philip Kazmeier"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app, which requires user interaction."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.6"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2019-11896",
    "datePublished": "2019-05-29T20:11:00.829405Z",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-09-16T19:24:49.342Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-11891 (GCVE-0-2019-11891)
Vulnerability from cvelistv5
Published
2019-05-29 19:40
Modified
2024-09-16 18:13
CWE
  • CWE-266 - Incorrect Privilege Assignment
Summary
A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary's choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack.
References
Impacted products
Vendor Product Version
Bosch Smart Home Controller Version: unspecified   < 9.8.905
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.575Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Smart Home Controller",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThan": "9.8.905",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Philip Kazmeier"
        }
      ],
      "datePublic": "2019-05-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary\u0027s choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-266",
              "description": "CWE-266 Incorrect Privilege Assignment",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-29T19:40:01",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Incorrect privilege assignment in the app pairing mechanism of the Bosch Smart Home Controller (SHC)",
      "x_generator": {
        "engine": "Vulnogram 0.0.6"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2019-05-29T12:00:00.000Z",
          "ID": "CVE-2019-11891",
          "STATE": "PUBLIC",
          "TITLE": "Incorrect privilege assignment in the app pairing mechanism of the Bosch Smart Home Controller (SHC)"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Smart Home Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.8.905"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Philip Kazmeier"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential incorrect privilege assignment vulnerability exists in the app pairing mechanism of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in elevated privileges of the adversary\u0027s choosing. In order to exploit the vulnerability, the adversary needs physical access to the SHC during the attack."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.6"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-266 Incorrect Privilege Assignment"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2019-11891",
    "datePublished": "2019-05-29T19:40:01.253370Z",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-09-16T18:13:51.172Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-11895 (GCVE-0-2019-11895)
Vulnerability from cvelistv5
Published
2019-05-29 20:07
Modified
2024-09-16 18:03
CWE
  • CWE-284 - Improper Access Control
Summary
A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a successful denial of service of the SHC and connected sensors and actuators. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction.
References
Impacted products
Vendor Product Version
Bosch Smart Home Controller Version: unspecified   < 9.8.905
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.614Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Smart Home Controller",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThan": "9.8.905",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Philip Kazmeier"
        }
      ],
      "datePublic": "2019-05-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a successful denial of service of the SHC and connected sensors and actuators. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-29T20:07:39",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)",
      "x_generator": {
        "engine": "Vulnogram 0.0.6"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2019-05-29T12:00:00.000Z",
          "ID": "CVE-2019-11895",
          "STATE": "PUBLIC",
          "TITLE": "Improper access control in the JSON-RPC interface of the Bosch Smart Home Controller (SHC)"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Smart Home Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.8.905"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Philip Kazmeier"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential improper access control vulnerability exists in the JSON-RPC interface of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a successful denial of service of the SHC and connected sensors and actuators. In order to exploit the vulnerability, the adversary needs to have successfully paired an app or service, which requires user interaction."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.6"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2019-11895",
    "datePublished": "2019-05-29T20:07:39.228984Z",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-09-16T18:03:37.169Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-11893 (GCVE-0-2019-11893)
Vulnerability from cvelistv5
Published
2019-05-29 19:58
Modified
2024-09-16 22:46
CWE
  • CWE-266 - Incorrect Privilege Assignment
Summary
A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app with restricted permissions, which required user interaction.
References
Impacted products
Vendor Product Version
Bosch Smart Home Controller Version: unspecified   < 9.8.905
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.449Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Smart Home Controller",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThan": "9.8.905",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Philip Kazmeier"
        }
      ],
      "datePublic": "2019-05-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app with restricted permissions, which required user interaction."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-266",
              "description": "CWE-266 Incorrect Privilege Assignment",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-29T19:58:04",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Incorrect privilege assignment in the app permission update API of the Bosch Smart Home Controller (SHC)",
      "x_generator": {
        "engine": "Vulnogram 0.0.6"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2019-05-29T12:00:00.000Z",
          "ID": "CVE-2019-11893",
          "STATE": "PUBLIC",
          "TITLE": "Incorrect privilege assignment in the app permission update API of the Bosch Smart Home Controller (SHC)"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Smart Home Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "9.8.905"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Philip Kazmeier"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app with restricted permissions, which required user interaction."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.6"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-266 Incorrect Privilege Assignment"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2019-11893",
    "datePublished": "2019-05-29T19:58:04.150033Z",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-09-16T22:46:47.017Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}