Vulnerabilites related to B&R Industrial Automation - Technology Guarding
CVE-2024-0220 (GCVE-0-2024-0220)
Vulnerability from cvelistv5
Published
2024-02-22 10:15
Modified
2024-09-19 17:24
Severity ?
VLAI Severity ?
EPSS score ?
CWE
Summary
B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | B&R Industrial Automation | Automation Studio |
Version: 4.0 |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T17:41:15.976Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:br-automation:automation_studio:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "automation_studio", "vendor": "br-automation", "versions": [ { "lessThan": "4.6", "status": "affected", "version": "4.0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-0220", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-02-22T16:23:26.378691Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-28T16:52:09.908Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "modules": [ "Upgrade Service" ], "product": "Automation Studio", "vendor": "B\u0026R Industrial Automation", "versions": [ { "lessThan": "4.6", "status": "affected", "version": "4.0", "versionType": "patch" } ] }, { "defaultStatus": "unaffected", "product": "Technology Guarding", "vendor": "B\u0026R Industrial Automation", "versions": [ { "lessThan": "1.4.0", "status": "affected", "version": "1.0.0", "versionType": "patch" } ] } ], "datePublic": "2024-02-22T10:10:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "B\u0026amp;R Automation Studio Upgrade Service and B\u0026amp;R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data.\n\n\u003cbr\u003e" } ], "value": "B\u0026R Automation Studio Upgrade Service and B\u0026R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1240", "description": "CWE-1240: Use of a Cryptographic Primitive with a Risky Implementation", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319 Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-94", "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-19T17:24:51.723Z", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "references": [ { "url": "https://www.br-automation.com/fileadmin/SA23P019_Automation_Studio_Upgrade_Service_uses_insufficient_encryption.pdf-1b3b181c.pdf" } ], "source": { "advisory": "2023-P019", "discovery": "INTERNAL" }, "title": "B\u0026R products use insufficient communication encryption", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2024-0220", "datePublished": "2024-02-22T10:15:44.750Z", "dateReserved": "2024-01-03T15:46:41.224Z", "dateUpdated": "2024-09-19T17:24:51.723Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }