Vulnerabilites related to Schneider Electric - Triconex Tricon
CVE-2018-8872 (GCVE-0-2018-8872)
Vulnerability from cvelistv5
Published
2018-05-04 17:00
Modified
2024-09-16 16:32
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-119 - Improper Restriction Of Operations Within The Bounds Of A Memory Buffer
Summary
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | Triconex Tricon |
Version: MP model 3008 firmware versions 10.0-10.4 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T07:10:46.217Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02" }, { "name": "103947", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/103947" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Triconex Tricon", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "MP model 3008 firmware versions 10.0-10.4" } ] } ], "datePublic": "2018-04-17T00:00:00", "descriptions": [ { "lang": "en", "value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-05-05T09:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02" }, { "name": "103947", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/103947" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-04-17T00:00:00", "ID": "CVE-2018-8872", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Triconex Tricon", "version": { "version_data": [ { "version_value": "MP model 3008 firmware versions 10.0-10.4" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/", "refsource": "CONFIRM", "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02" }, { "name": "103947", "refsource": "BID", "url": "http://www.securityfocus.com/bid/103947" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-8872", "datePublished": "2018-05-04T17:00:00Z", "dateReserved": "2018-03-20T00:00:00", "dateUpdated": "2024-09-16T16:32:36.977Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-7522 (GCVE-0-2018-7522)
Vulnerability from cvelistv5
Published
2018-05-04 17:00
Modified
2024-09-17 00:02
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-119 - Improper Restriction Of Operations Within The Bounds Of A Memory Buffer
Summary
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Schneider Electric | Triconex Tricon |
Version: MP model 3008 firmware versions 10.0-10.4 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T06:31:04.336Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02" }, { "name": "103947", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/103947" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Triconex Tricon", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "MP model 3008 firmware versions 10.0-10.4" } ] } ], "datePublic": "2018-04-17T00:00:00", "descriptions": [ { "lang": "en", "value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-119", "description": "Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-05-05T09:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02" }, { "name": "103947", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/103947" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2018-04-17T00:00:00", "ID": "CVE-2018-7522", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Triconex Tricon", "version": { "version_data": [ { "version_value": "MP model 3008 firmware versions 10.0-10.4" } ] } } ] }, "vendor_name": "Schneider Electric" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/", "refsource": "CONFIRM", "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02" }, { "name": "103947", "refsource": "BID", "url": "http://www.securityfocus.com/bid/103947" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-7522", "datePublished": "2018-05-04T17:00:00Z", "dateReserved": "2018-02-26T00:00:00", "dateUpdated": "2024-09-17T00:02:25.672Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }