Vulnerabilites related to Dario Health - USB-C Blood Glucose Monitoring System Starter Kit Android Applications
CVE-2025-24843 (GCVE-0-2025-24843)
Vulnerability from cvelistv5
Published
2025-02-28 16:56
Modified
2025-02-28 21:50
Severity ?
5.1 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L
5.1 (Medium) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N
5.1 (Medium) - CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
Summary
Insecure file retrieval process that facilitates potential for file manipulation to affect product stability and confidentiality, integrity, authenticity, and attestation of stored data.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Dario Health | USB-C Blood Glucose Monitoring System Starter Kit Android Applications |
Version: 0 < 5.8.7.0.36 |
||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-24843", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-28T21:50:31.032336Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-28T21:50:42.235Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "USB-C Blood Glucose Monitoring System Starter Kit Android Applications", "vendor": "Dario Health", "versions": [ { "lessThan": "5.8.7.0.36", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Dario Application Database and Internet-based Server Infrastructure", "vendor": "Dario Health", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Noah Cutler and Manuel Del Rio of Accenture reported these vulnerabilities to CISA." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eInsecure file retrieval process that facilitates potential for file manipulation to affect product stability and confidentiality, integrity, authenticity, and attestation of stored data.\u003c/span\u003e" } ], "value": "Insecure file retrieval process that facilitates potential for file manipulation to affect product stability and confidentiality, integrity, authenticity, and attestation of stored data." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 5.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "baseScore": 5.1, "baseSeverity": "MEDIUM", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "LOW", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "LOW", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-921", "description": "CWE-921", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-28T16:56:11.789Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-058-01" }, { "url": "https://www.dariohealth.com/contact/" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.\u003c/span\u003e\n\n\u003cbr\u003e" } ], "value": "Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users." } ], "source": { "advisory": "ICSMA-25-058-01", "discovery": "EXTERNAL" }, "title": "Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Storage of Sensitive Data in a Mechanism without Access Control", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eDario Health recommends users perform the following mitigations:\u0026nbsp; \u003cbr\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eUpdate the application from trusted sources.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eDon\u0027t use rooted/jailbroken devices.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eAvoid public untrusted network.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eFor more information \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dariohealth.com/contact/\"\u003econtact Dario Health\u003c/a\u003e\u0026nbsp;directly.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e" } ], "value": "Dario Health recommends users perform the following mitigations:\u00a0 \n\n\n * Update the application from trusted sources.\u00a0 \n\n * Don\u0027t use rooted/jailbroken devices.\u00a0 \n\n * Avoid public untrusted network.\u00a0 \n\n * For more information contact Dario Health https://www.dariohealth.com/contact/ \u00a0directly." } ], "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2025-24843", "datePublished": "2025-02-28T16:56:11.789Z", "dateReserved": "2025-01-27T21:33:08.406Z", "dateUpdated": "2025-02-28T21:50:42.235Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-24849 (GCVE-0-2025-24849)
Vulnerability from cvelistv5
Published
2025-02-28 16:58
Modified
2025-02-28 21:50
Severity ?
7.1 (High) - CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
7.5 (High) - CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.5 (High) - CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Summary
Lack of encryption in transit for cloud infrastructure facilitating potential for sensitive data manipulation or exposure.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Dario Health | USB-C Blood Glucose Monitoring System Starter Kit Android Applications |
Version: 0 < 5.8.7.0.36 |
||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-24849", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-28T21:49:01.903063Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-28T21:50:19.286Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "USB-C Blood Glucose Monitoring System Starter Kit Android Applications", "vendor": "Dario Health", "versions": [ { "lessThan": "5.8.7.0.36", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Dario Application Database and Internet-based Server Infrastructure", "vendor": "Dario Health", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Noah Cutler and Manuel Del Rio of Accenture reported these vulnerabilities to CISA." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eLack of encryption in transit for cloud infrastructure facilitating potential for sensitive data manipulation or exposure.\u003c/span\u003e\n\n\u003c/span\u003e" } ], "value": "Lack of encryption in transit for cloud infrastructure facilitating potential for sensitive data manipulation or exposure." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "HIGH", "attackRequirements": "PRESENT", "attackVector": "ADJACENT", "baseScore": 7.5, "baseSeverity": "HIGH", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "PASSIVE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319 Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-28T16:58:55.473Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-058-01" }, { "url": "https://www.dariohealth.com/contact/" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.\u003c/span\u003e\n\n\u003cbr\u003e" } ], "value": "Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users." } ], "source": { "advisory": "ICSMA-25-058-01", "discovery": "EXTERNAL" }, "title": "Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Cleartext Transmission of Sensitive Information", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eDario Health recommends users perform the following mitigations:\u0026nbsp; \u003cbr\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eUpdate the application from trusted sources.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eDon\u0027t use rooted/jailbroken devices.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eAvoid public untrusted network.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eFor more information \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dariohealth.com/contact/\"\u003econtact Dario Health\u003c/a\u003e\u0026nbsp;directly.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e" } ], "value": "Dario Health recommends users perform the following mitigations:\u00a0 \n\n\n * Update the application from trusted sources.\u00a0 \n\n * Don\u0027t use rooted/jailbroken devices.\u00a0 \n\n * Avoid public untrusted network.\u00a0 \n\n * For more information contact Dario Health https://www.dariohealth.com/contact/ \u00a0directly." } ], "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2025-24849", "datePublished": "2025-02-28T16:58:55.473Z", "dateReserved": "2025-01-27T21:33:08.429Z", "dateUpdated": "2025-02-28T21:50:19.286Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-23405 (GCVE-0-2025-23405)
Vulnerability from cvelistv5
Published
2025-02-28 16:54
Modified
2025-02-28 21:51
Severity ?
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
6.9 (Medium) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N
6.9 (Medium) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
Summary
Unauthenticated log effects metrics gathering incident response efforts and potentially exposes risk of injection attacks (ex log injection).
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Dario Health | USB-C Blood Glucose Monitoring System Starter Kit Android Applications |
Version: 0 < 5.8.7.0.36 |
||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-23405", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-28T21:50:54.652348Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-28T21:51:08.124Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "USB-C Blood Glucose Monitoring System Starter Kit Android Applications", "vendor": "Dario Health", "versions": [ { "lessThan": "5.8.7.0.36", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Dario Application Database and Internet-based Server Infrastructure", "vendor": "Dario Health", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Noah Cutler and Manuel Del Rio of Accenture reported these vulnerabilities to CISA." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUnauthenticated log effects metrics gathering incident response efforts and potentially exposes risk of injection attacks (ex log injection).\u003c/span\u003e\n\n\u003c/span\u003e" } ], "value": "Unauthenticated log effects metrics gathering incident response efforts and potentially exposes risk of injection attacks (ex log injection)." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 6.9, "baseSeverity": "MEDIUM", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "LOW", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-117", "description": "CWE-117", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-28T16:54:01.759Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-058-01" }, { "url": "https://www.dariohealth.com/contact/" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.\u003c/span\u003e\n\n\u003cbr\u003e" } ], "value": "Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users." } ], "source": { "advisory": "ICSMA-25-058-01", "discovery": "EXTERNAL" }, "title": "Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Improper Output Neutralization For Logs", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eDario Health recommends users perform the following mitigations:\u0026nbsp; \u003cbr\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eUpdate the application from trusted sources.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eDon\u0027t use rooted/jailbroken devices.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eAvoid public untrusted network.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eFor more information \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dariohealth.com/contact/\"\u003econtact Dario Health\u003c/a\u003e\u0026nbsp;directly.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e" } ], "value": "Dario Health recommends users perform the following mitigations:\u00a0 \n\n\n * Update the application from trusted sources.\u00a0 \n\n * Don\u0027t use rooted/jailbroken devices.\u00a0 \n\n * Avoid public untrusted network.\u00a0 \n\n * For more information contact Dario Health https://www.dariohealth.com/contact/ \u00a0directly." } ], "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2025-23405", "datePublished": "2025-02-28T16:54:01.759Z", "dateReserved": "2025-01-27T21:33:08.388Z", "dateUpdated": "2025-02-28T21:51:08.124Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-20060 (GCVE-0-2025-20060)
Vulnerability from cvelistv5
Published
2025-02-28 16:51
Modified
2025-02-28 21:58
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
VLAI Severity ?
EPSS score ?
CWE
Summary
An attacker could expose cross-user personal identifiable information (PII) and personal health information transmitted to the Android device via the Dario Health application database.
References
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Dario Health | USB-C Blood Glucose Monitoring System Starter Kit Android Applications |
Version: 0 < 5.8.7.0.36 |
||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-20060", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-28T21:57:51.936930Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-02-28T21:58:18.544Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "USB-C Blood Glucose Monitoring System Starter Kit Android Applications", "vendor": "Dario Health", "versions": [ { "lessThan": "5.8.7.0.36", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Dario Application Database and Internet-based Server Infrastructure", "vendor": "Dario Health", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Noah Cutler and Manuel Del Rio of Accenture reported these vulnerabilities to CISA." } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn attacker could expose cross-user personal identifiable information (PII) and personal health information transmitted to the Android device via the Dario Health application database.\u003c/span\u003e" } ], "value": "An attacker could expose cross-user personal identifiable information (PII) and personal health information transmitted to the Android device via the Dario Health application database." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] }, { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 8.7, "baseSeverity": "HIGH", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-359", "description": "CWE-359", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-28T16:51:20.410Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-058-01" }, { "url": "https://www.dariohealth.com/contact/" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.\u003c/span\u003e\n\n\u003cbr\u003e" } ], "value": "Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users." } ], "source": { "advisory": "ICSMA-25-058-01", "discovery": "EXTERNAL" }, "title": "Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Exposure of Private Personal Information to an Unauthorized Actor", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\u003cp\u003eDario Health recommends users perform the following mitigations:\u0026nbsp; \u003cbr\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eUpdate the application from trusted sources.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eDon\u0027t use rooted/jailbroken devices.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eAvoid public untrusted network.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eFor more information \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dariohealth.com/contact/\"\u003econtact Dario Health\u003c/a\u003e\u0026nbsp;directly.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e" } ], "value": "Dario Health recommends users perform the following mitigations:\u00a0 \n\n\n * Update the application from trusted sources.\u00a0 \n\n * Don\u0027t use rooted/jailbroken devices.\u00a0 \n\n * Avoid public untrusted network.\u00a0 \n\n * For more information contact Dario Health https://www.dariohealth.com/contact/ \u00a0directly." } ], "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2025-20060", "datePublished": "2025-02-28T16:51:20.410Z", "dateReserved": "2025-01-27T21:33:08.318Z", "dateUpdated": "2025-02-28T21:58:18.544Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }