Vulnerabilites related to Dario Health - USB-C Blood Glucose Monitoring System Starter Kit Android Applications
CVE-2025-24843 (GCVE-0-2025-24843)
Vulnerability from cvelistv5
Published
2025-02-28 16:56
Modified
2025-02-28 21:50
CWE
Summary
Insecure file retrieval process that facilitates potential for file manipulation to affect product stability and confidentiality, integrity, authenticity, and attestation of stored data.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-24843",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-28T21:50:31.032336Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-28T21:50:42.235Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "USB-C Blood Glucose Monitoring System Starter Kit Android Applications",
          "vendor": "Dario Health",
          "versions": [
            {
              "lessThan": "5.8.7.0.36",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dario Application Database and Internet-based Server Infrastructure",
          "vendor": "Dario Health",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Noah Cutler and Manuel Del Rio of Accenture reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eInsecure file retrieval process that facilitates potential for file manipulation to affect product stability and confidentiality, integrity, authenticity, and attestation of stored data.\u003c/span\u003e"
            }
          ],
          "value": "Insecure file retrieval process that facilitates potential for file manipulation to affect product stability and confidentiality, integrity, authenticity, and attestation of stored data."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-921",
              "description": "CWE-921",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-28T16:56:11.789Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-058-01"
        },
        {
          "url": "https://www.dariohealth.com/contact/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users."
        }
      ],
      "source": {
        "advisory": "ICSMA-25-058-01",
        "discovery": "EXTERNAL"
      },
      "title": "Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Storage of Sensitive Data in a Mechanism without Access Control",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eDario Health recommends users perform the following mitigations:\u0026nbsp; \u003cbr\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eUpdate the application from trusted sources.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eDon\u0027t use rooted/jailbroken devices.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eAvoid public untrusted network.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eFor more information \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dariohealth.com/contact/\"\u003econtact Dario Health\u003c/a\u003e\u0026nbsp;directly.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dario Health recommends users perform the following mitigations:\u00a0 \n\n\n  *  Update the application from trusted sources.\u00a0 \n\n  *  Don\u0027t use rooted/jailbroken devices.\u00a0 \n\n  *  Avoid public untrusted network.\u00a0 \n\n  *  For more information  contact Dario Health https://www.dariohealth.com/contact/ \u00a0directly."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-24843",
    "datePublished": "2025-02-28T16:56:11.789Z",
    "dateReserved": "2025-01-27T21:33:08.406Z",
    "dateUpdated": "2025-02-28T21:50:42.235Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-24849 (GCVE-0-2025-24849)
Vulnerability from cvelistv5
Published
2025-02-28 16:58
Modified
2025-02-28 21:50
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Summary
Lack of encryption in transit for cloud infrastructure facilitating potential for sensitive data manipulation or exposure.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-24849",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-28T21:49:01.903063Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-28T21:50:19.286Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "USB-C Blood Glucose Monitoring System Starter Kit Android Applications",
          "vendor": "Dario Health",
          "versions": [
            {
              "lessThan": "5.8.7.0.36",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dario Application Database and Internet-based Server Infrastructure",
          "vendor": "Dario Health",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Noah Cutler and Manuel Del Rio of Accenture reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eLack of encryption in transit for cloud infrastructure facilitating potential for sensitive data manipulation or exposure.\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "Lack of encryption in transit for cloud infrastructure facilitating potential for sensitive data manipulation or exposure."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-28T16:58:55.473Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-058-01"
        },
        {
          "url": "https://www.dariohealth.com/contact/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users."
        }
      ],
      "source": {
        "advisory": "ICSMA-25-058-01",
        "discovery": "EXTERNAL"
      },
      "title": "Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Cleartext Transmission of Sensitive Information",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eDario Health recommends users perform the following mitigations:\u0026nbsp; \u003cbr\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eUpdate the application from trusted sources.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eDon\u0027t use rooted/jailbroken devices.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eAvoid public untrusted network.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eFor more information \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dariohealth.com/contact/\"\u003econtact Dario Health\u003c/a\u003e\u0026nbsp;directly.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dario Health recommends users perform the following mitigations:\u00a0 \n\n\n  *  Update the application from trusted sources.\u00a0 \n\n  *  Don\u0027t use rooted/jailbroken devices.\u00a0 \n\n  *  Avoid public untrusted network.\u00a0 \n\n  *  For more information  contact Dario Health https://www.dariohealth.com/contact/ \u00a0directly."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-24849",
    "datePublished": "2025-02-28T16:58:55.473Z",
    "dateReserved": "2025-01-27T21:33:08.429Z",
    "dateUpdated": "2025-02-28T21:50:19.286Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-23405 (GCVE-0-2025-23405)
Vulnerability from cvelistv5
Published
2025-02-28 16:54
Modified
2025-02-28 21:51
CWE
Summary
Unauthenticated log effects metrics gathering incident response efforts and potentially exposes risk of injection attacks (ex log injection).
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-23405",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-28T21:50:54.652348Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-28T21:51:08.124Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "USB-C Blood Glucose Monitoring System Starter Kit Android Applications",
          "vendor": "Dario Health",
          "versions": [
            {
              "lessThan": "5.8.7.0.36",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dario Application Database and Internet-based Server Infrastructure",
          "vendor": "Dario Health",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Noah Cutler and Manuel Del Rio of Accenture reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUnauthenticated log effects metrics gathering incident response efforts and potentially exposes risk of injection attacks (ex log injection).\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "Unauthenticated log effects metrics gathering incident response efforts and potentially exposes risk of injection attacks (ex log injection)."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-117",
              "description": "CWE-117",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-28T16:54:01.759Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-058-01"
        },
        {
          "url": "https://www.dariohealth.com/contact/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users."
        }
      ],
      "source": {
        "advisory": "ICSMA-25-058-01",
        "discovery": "EXTERNAL"
      },
      "title": "Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Improper Output Neutralization For Logs",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eDario Health recommends users perform the following mitigations:\u0026nbsp; \u003cbr\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eUpdate the application from trusted sources.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eDon\u0027t use rooted/jailbroken devices.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eAvoid public untrusted network.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eFor more information \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dariohealth.com/contact/\"\u003econtact Dario Health\u003c/a\u003e\u0026nbsp;directly.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dario Health recommends users perform the following mitigations:\u00a0 \n\n\n  *  Update the application from trusted sources.\u00a0 \n\n  *  Don\u0027t use rooted/jailbroken devices.\u00a0 \n\n  *  Avoid public untrusted network.\u00a0 \n\n  *  For more information  contact Dario Health https://www.dariohealth.com/contact/ \u00a0directly."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-23405",
    "datePublished": "2025-02-28T16:54:01.759Z",
    "dateReserved": "2025-01-27T21:33:08.388Z",
    "dateUpdated": "2025-02-28T21:51:08.124Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-20060 (GCVE-0-2025-20060)
Vulnerability from cvelistv5
Published
2025-02-28 16:51
Modified
2025-02-28 21:58
CWE
Summary
An attacker could expose cross-user personal identifiable information (PII) and personal health information transmitted to the Android device via the Dario Health application database.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-20060",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-28T21:57:51.936930Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-28T21:58:18.544Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "USB-C Blood Glucose Monitoring System Starter Kit Android Applications",
          "vendor": "Dario Health",
          "versions": [
            {
              "lessThan": "5.8.7.0.36",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Dario Application Database and Internet-based Server Infrastructure",
          "vendor": "Dario Health",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Noah Cutler and Manuel Del Rio of Accenture reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn attacker could expose cross-user personal identifiable information (PII) and personal health information transmitted to the Android device via the Dario Health application database.\u003c/span\u003e"
            }
          ],
          "value": "An attacker could expose cross-user personal identifiable information (PII) and personal health information transmitted to the Android device via the Dario Health application database."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-359",
              "description": "CWE-359",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-28T16:51:20.410Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-058-01"
        },
        {
          "url": "https://www.dariohealth.com/contact/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users."
        }
      ],
      "source": {
        "advisory": "ICSMA-25-058-01",
        "discovery": "EXTERNAL"
      },
      "title": "Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Exposure of Private Personal Information to an Unauthorized Actor",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eDario Health recommends users perform the following mitigations:\u0026nbsp; \u003cbr\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eUpdate the application from trusted sources.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eDon\u0027t use rooted/jailbroken devices.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eAvoid public untrusted network.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003cli\u003eFor more information \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dariohealth.com/contact/\"\u003econtact Dario Health\u003c/a\u003e\u0026nbsp;directly.\u0026nbsp; \u003cbr\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Dario Health recommends users perform the following mitigations:\u00a0 \n\n\n  *  Update the application from trusted sources.\u00a0 \n\n  *  Don\u0027t use rooted/jailbroken devices.\u00a0 \n\n  *  Avoid public untrusted network.\u00a0 \n\n  *  For more information  contact Dario Health https://www.dariohealth.com/contact/ \u00a0directly."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2025-20060",
    "datePublished": "2025-02-28T16:51:20.410Z",
    "dateReserved": "2025-01-27T21:33:08.318Z",
    "dateUpdated": "2025-02-28T21:58:18.544Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}