Vulnerabilites related to B&R Industrial Automation - Windows Settings Changer (LTSC)
CVE-2024-2637 (GCVE-0-2024-2637)
Vulnerability from cvelistv5
Published
2024-05-14 18:49
Modified
2025-04-24 06:52
CWE
  • CWE-427 - Uncontrolled Search Path Element
Summary
An Uncontrolled Search Path Element vulnerability in B&R Industrial Automation Scene Viewer, B&R Industrial Automation Automation Runtime, B&R Industrial Automation mapp Vision, B&R Industrial Automation mapp View, B&R Industrial Automation mapp Cockpit, B&R Industrial Automation mapp Safety, B&R Industrial Automation VC4, B&R Industrial Automation APROL, B&R Industrial Automation CAN Driver, B&R Industrial Automation CAN Driver CC770, B&R Industrial Automation CAN Driver SJA1000, B&R Industrial Automation Tou0ch Lock, B&R Industrial Automation B&R Single-Touch Driver, B&R Industrial Automation Serial User Mode Touch Driver, B&R Industrial Automation Windows Settings Changer (LTSC), B&R Industrial Automation Windows Settings Changer (2019 LTSC), B&R Industrial Automation Windows 10 Recovery Solution, B&R Industrial Automation ADI driver universal, B&R Industrial Automation ADI Development Kit, B&R Industrial Automation ADI .NET SDK, B&R Industrial Automation SRAM driver, B&R Industrial Automation HMI Service Center, B&R Industrial Automation HMI Service Center Maintenance, B&R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC, B&R Industrial Automation KCF Editor could allow an authenticated local attacker to execute malicious code by placing specially crafted files in the loading search path..This issue affects Scene Viewer: before 4.4.0; Automation Runtime: before J4.93; mapp Vision: before 5.26.1; mapp View: before 5.24.2; mapp Cockpit: before 5.24.2; mapp Safety: before 5.24.2; VC4: before 4.73.2; APROL: before 4.4-01; CAN Driver: before 1.1.0; CAN Driver CC770: before 3.3.0; CAN Driver SJA1000: before 1.3.0; Tou0ch Lock: before 2.1.0; B&R Single-Touch Driver: before 2.0.0; Serial User Mode Touch Driver: before 1.7.1; Windows Settings Changer (LTSC): before 3.2.0; Windows Settings Changer (2019 LTSC): before 2.2.0; Windows 10 Recovery Solution: before 3.2.0; ADI driver universal: before 3.2.0; ADI Development Kit: before 5.5.0; ADI .NET SDK: before 4.1.0; SRAM driver: before 1.2.0; HMI Service Center: before 3.1.0; HMI Service Center Maintenance: before 2.1.0; Windows 10 IoT Enterprise 2019 LTSC: through 1.1; KCF Editor: before 1.1.0.
Impacted products
Vendor Product Version
B&R Industrial Automation Scene Viewer Version: 0   < 4.4.0
Create a notification for this product.
   B&R Industrial Automation Automation Runtime Version: 0   < J4.93
Create a notification for this product.
   B&R Industrial Automation mapp Vision Version: 0   < 5.26.1
Create a notification for this product.
   B&R Industrial Automation mapp View Version: 0   < 5.24.2
Create a notification for this product.
   B&R Industrial Automation mapp Cockpit Version: 0   < 5.24.2
Create a notification for this product.
   B&R Industrial Automation mapp Safety Version: 0   < 5.24.2
Create a notification for this product.
   B&R Industrial Automation VC4 Version: 0   < 4.73.2
Create a notification for this product.
   B&R Industrial Automation APROL Version: 0   < 4.4-01
Create a notification for this product.
   B&R Industrial Automation CAN Driver Version: 0   < 1.1.0
Create a notification for this product.
   B&R Industrial Automation CAN Driver CC770 Version: 0   < 3.3.0
Create a notification for this product.
   B&R Industrial Automation CAN Driver SJA1000 Version: 0   < 1.3.0
Create a notification for this product.
   B&R Industrial Automation Tou0ch Lock Version: 0   < 2.1.0
Create a notification for this product.
   B&R Industrial Automation B&R Single-Touch Driver Version: 0   < 2.0.0
Create a notification for this product.
   B&R Industrial Automation Serial User Mode Touch Driver Version: 0   < 1.7.1
Create a notification for this product.
   B&R Industrial Automation Windows Settings Changer (LTSC) Version: 0   < 3.2.0
Create a notification for this product.
   B&R Industrial Automation Windows Settings Changer (2019 LTSC) Version: 0   < 2.2.0
Create a notification for this product.
   B&R Industrial Automation Windows 10 Recovery Solution Version: 0   < 3.2.0
Create a notification for this product.
   B&R Industrial Automation ADI driver universal Version: 0   < 3.2.0
Create a notification for this product.
   B&R Industrial Automation ADI Development Kit Version: 0   < 5.5.0
Create a notification for this product.
   B&R Industrial Automation ADI .NET SDK Version: 0   < 4.1.0
Create a notification for this product.
   B&R Industrial Automation SRAM driver Version: 0   < 1.2.0
Create a notification for this product.
   B&R Industrial Automation HMI Service Center Version: 0   < 3.1.0
Create a notification for this product.
   B&R Industrial Automation HMI Service Center Maintenance Version: 0   < 2.1.0
Create a notification for this product.
   B&R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC Version: 0   <
Create a notification for this product.
   B&R Industrial Automation KCF Editor Version: 0   < 1.1.0
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:br-automation:scene_viewer:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "scene_viewer",
            "vendor": "br-automation",
            "versions": [
              {
                "lessThan": "4.4.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:br-automation:automation_runtime:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "automation_runtime",
            "vendor": "br-automation",
            "versions": [
              {
                "lessThan": "j4.93",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:br-automation:mapp_vision:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mapp_vision",
            "vendor": "br-automation",
            "versions": [
              {
                "lessThan": "5.26.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:br-automation:mapp_view:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mapp_view",
            "vendor": "br-automation",
            "versions": [
              {
                "lessThan": "5.24.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:br-automation:mapp_cockpit:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mapp_cockpit",
            "vendor": "br-automation",
            "versions": [
              {
                "lessThan": "5.24.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:br-automation:vc4:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "vc4",
            "vendor": "br-automation",
            "versions": [
              {
                "lessThan": "4.73.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2637",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-14T19:33:12.195778Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-06T14:56:12.677Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:18:48.124Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.br-automation.com/fileadmin/SA24P005_Insecure_Loading_of_Code-c7d9e49c.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Scene Viewer",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "4.4.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Automation Runtime",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "J4.93",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mapp Vision",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "5.26.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mapp View",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "5.24.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mapp Cockpit",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "5.24.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "mapp Safety",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "5.24.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "VC4",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "4.73.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "APROL",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "4.4-01",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CAN Driver",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "1.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CAN Driver CC770",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "3.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CAN Driver SJA1000",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "1.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Tou0ch Lock",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "2.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "B\u0026R Single-Touch Driver",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Serial User Mode Touch Driver",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "1.7.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Windows Settings Changer (LTSC)",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "3.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Windows Settings Changer (2019 LTSC)",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "2.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Windows 10 Recovery Solution",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "3.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ADI driver universal",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "3.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ADI Development Kit",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "5.5.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ADI .NET SDK",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SRAM driver",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "1.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "HMI Service Center",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "3.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "HMI Service Center Maintenance",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "2.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Windows 10 IoT Enterprise 2019 LTSC",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThanOrEqual": "1.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "KCF Editor",
          "vendor": "B\u0026R Industrial Automation",
          "versions": [
            {
              "lessThan": "1.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2025-04-02T18:50:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Uncontrolled Search Path Element vulnerability\u0026nbsp;in B\u0026amp;R Industrial Automation Scene Viewer, B\u0026amp;R Industrial Automation Automation Runtime, B\u0026amp;R Industrial Automation mapp Vision, B\u0026amp;R Industrial Automation mapp View, B\u0026amp;R Industrial Automation mapp Cockpit, B\u0026amp;R Industrial Automation mapp Safety, B\u0026amp;R Industrial Automation VC4, B\u0026amp;R Industrial Automation APROL, B\u0026amp;R Industrial Automation CAN Driver, B\u0026amp;R Industrial Automation CAN Driver CC770, B\u0026amp;R Industrial Automation CAN Driver SJA1000, B\u0026amp;R Industrial Automation Tou0ch Lock, B\u0026amp;R Industrial Automation B\u0026amp;R Single-Touch Driver, B\u0026amp;R Industrial Automation Serial User Mode Touch Driver, B\u0026amp;R Industrial Automation Windows Settings Changer (LTSC), B\u0026amp;R Industrial Automation Windows Settings Changer (2019 LTSC), B\u0026amp;R Industrial Automation Windows 10 Recovery Solution, B\u0026amp;R Industrial Automation ADI driver universal, B\u0026amp;R Industrial Automation ADI Development Kit, B\u0026amp;R Industrial Automation ADI .NET SDK, B\u0026amp;R Industrial Automation SRAM driver, B\u0026amp;R Industrial Automation HMI Service Center, B\u0026amp;R Industrial Automation HMI Service Center Maintenance, B\u0026amp;R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC, B\u0026amp;R Industrial Automation KCF Editor could allow an authenticated local attacker to execute malicious code by placing specially crafted files in the loading search path..\u003cp\u003eThis issue affects Scene Viewer: before 4.4.0; Automation Runtime: before J4.93; mapp Vision: before 5.26.1; mapp View: before 5.24.2; mapp Cockpit: before 5.24.2; mapp Safety: before 5.24.2; VC4: before 4.73.2; APROL: before 4.4-01; CAN Driver: before 1.1.0; CAN Driver CC770: before 3.3.0; CAN Driver SJA1000: before 1.3.0; Tou0ch Lock: before 2.1.0; B\u0026amp;R Single-Touch Driver: before 2.0.0; Serial User Mode Touch Driver: before 1.7.1; Windows Settings Changer (LTSC): before 3.2.0; Windows Settings Changer (2019 LTSC): before 2.2.0; Windows 10 Recovery Solution: before 3.2.0; ADI driver universal: before 3.2.0; ADI Development Kit: before 5.5.0; ADI .NET SDK: before 4.1.0; SRAM driver: before 1.2.0; HMI Service Center: before 3.1.0; HMI Service Center Maintenance: before 2.1.0; Windows 10 IoT Enterprise 2019 LTSC: through 1.1; KCF Editor: before 1.1.0.\u003c/p\u003e"
            }
          ],
          "value": "An Uncontrolled Search Path Element vulnerability\u00a0in B\u0026R Industrial Automation Scene Viewer, B\u0026R Industrial Automation Automation Runtime, B\u0026R Industrial Automation mapp Vision, B\u0026R Industrial Automation mapp View, B\u0026R Industrial Automation mapp Cockpit, B\u0026R Industrial Automation mapp Safety, B\u0026R Industrial Automation VC4, B\u0026R Industrial Automation APROL, B\u0026R Industrial Automation CAN Driver, B\u0026R Industrial Automation CAN Driver CC770, B\u0026R Industrial Automation CAN Driver SJA1000, B\u0026R Industrial Automation Tou0ch Lock, B\u0026R Industrial Automation B\u0026R Single-Touch Driver, B\u0026R Industrial Automation Serial User Mode Touch Driver, B\u0026R Industrial Automation Windows Settings Changer (LTSC), B\u0026R Industrial Automation Windows Settings Changer (2019 LTSC), B\u0026R Industrial Automation Windows 10 Recovery Solution, B\u0026R Industrial Automation ADI driver universal, B\u0026R Industrial Automation ADI Development Kit, B\u0026R Industrial Automation ADI .NET SDK, B\u0026R Industrial Automation SRAM driver, B\u0026R Industrial Automation HMI Service Center, B\u0026R Industrial Automation HMI Service Center Maintenance, B\u0026R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC, B\u0026R Industrial Automation KCF Editor could allow an authenticated local attacker to execute malicious code by placing specially crafted files in the loading search path..This issue affects Scene Viewer: before 4.4.0; Automation Runtime: before J4.93; mapp Vision: before 5.26.1; mapp View: before 5.24.2; mapp Cockpit: before 5.24.2; mapp Safety: before 5.24.2; VC4: before 4.73.2; APROL: before 4.4-01; CAN Driver: before 1.1.0; CAN Driver CC770: before 3.3.0; CAN Driver SJA1000: before 1.3.0; Tou0ch Lock: before 2.1.0; B\u0026R Single-Touch Driver: before 2.0.0; Serial User Mode Touch Driver: before 1.7.1; Windows Settings Changer (LTSC): before 3.2.0; Windows Settings Changer (2019 LTSC): before 2.2.0; Windows 10 Recovery Solution: before 3.2.0; ADI driver universal: before 3.2.0; ADI Development Kit: before 5.5.0; ADI .NET SDK: before 4.1.0; SRAM driver: before 1.2.0; HMI Service Center: before 3.1.0; HMI Service Center Maintenance: before 2.1.0; Windows 10 IoT Enterprise 2019 LTSC: through 1.1; KCF Editor: before 1.1.0."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-641",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-641 DLL Side-Loading"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-427",
              "description": "CWE-427 Uncontrolled Search Path Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-24T06:52:46.092Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://www.br-automation.com/fileadmin/SA24P005_Insecure_Loading_of_Code-c7d9e49c.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Insecure Loading of Code in B\u0026R Products",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2024-2637",
    "datePublished": "2024-05-14T18:49:28.624Z",
    "dateReserved": "2024-03-19T08:15:24.368Z",
    "dateUpdated": "2025-04-24T06:52:46.092Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",