Vulnerabilites related to ibm - _ibm_rational_lifecycle_integration_adapter_for_windchill
CVE-2014-4815 (GCVE-0-2014-4815)
Vulnerability from cvelistv5
Published
2014-12-12 02:00
Modified
2024-08-06 11:27
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Session fixation vulnerability in IBM Rational Lifecycle Integration Adapter for Windchill 1.x before 1.0.1 allows remote attackers to hijack web sessions via unspecified vectors.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T11:27:36.804Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "ibm-rlia-cve20144815-fixation(95401)", "tags": [ "vdb-entry", "x_refsource_XF", "x_transferred" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/95401" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www-01.ibm.com/support/docview.wss?uid=swg21691993" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2014-12-10T00:00:00", "descriptions": [ { "lang": "en", "value": "Session fixation vulnerability in IBM Rational Lifecycle Integration Adapter for Windchill 1.x before 1.0.1 allows remote attackers to hijack web sessions via unspecified vectors." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2017-08-28T12:57:01", "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522", "shortName": "ibm" }, "references": [ { "name": "ibm-rlia-cve20144815-fixation(95401)", "tags": [ "vdb-entry", "x_refsource_XF" ], "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/95401" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www-01.ibm.com/support/docview.wss?uid=swg21691993" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@us.ibm.com", "ID": "CVE-2014-4815", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Session fixation vulnerability in IBM Rational Lifecycle Integration Adapter for Windchill 1.x before 1.0.1 allows remote attackers to hijack web sessions via unspecified vectors." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "ibm-rlia-cve20144815-fixation(95401)", "refsource": "XF", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/95401" }, { "name": "http://www-01.ibm.com/support/docview.wss?uid=swg21691993", "refsource": "CONFIRM", "url": "http://www-01.ibm.com/support/docview.wss?uid=swg21691993" } ] } } } }, "cveMetadata": { "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522", "assignerShortName": "ibm", "cveId": "CVE-2014-4815", "datePublished": "2014-12-12T02:00:00", "dateReserved": "2014-07-09T00:00:00", "dateUpdated": "2024-08-06T11:27:36.804Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-34587 (GCVE-0-2021-34587)
Vulnerability from cvelistv5
Published
2022-04-27 15:15
Modified
2024-09-17 02:58
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Bender / ebee | CC612 |
Version: 5.11.x < 5.11.2 Version: 5.12.x < 5.12.5 Version: 5.13.x < 5.13.2 Version: 5.20.x < 5.20.2 |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T00:19:46.977Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert.vde.com/en/advisories/VDE-2021-047" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CC612", "vendor": "Bender / ebee", "versions": [ { "lessThan": "5.11.2", "status": "affected", "version": "5.11.x", "versionType": "custom" }, { "lessThan": "5.12.5", "status": "affected", "version": "5.12.x", "versionType": "custom" }, { "lessThan": "5.13.2", "status": "affected", "version": "5.13.x", "versionType": "custom" }, { "lessThan": "5.20.2", "status": "affected", "version": "5.20.x", "versionType": "custom" } ] }, { "product": "CC613", "vendor": "Bender / ebee", "versions": [ { "lessThan": "5.11.2", "status": "affected", "version": "5.11.x", "versionType": "custom" }, { "lessThan": "5.12.5", "status": "affected", "version": "5.12.x", "versionType": "custom" }, { "lessThan": "5.13.2", "status": "affected", "version": "5.13.x", "versionType": "custom" }, { "lessThan": "5.20.2", "status": "affected", "version": "5.20.x", "versionType": "custom" } ] }, { "product": "ICC15xx", "vendor": "Bender / ebee", "versions": [ { "lessThan": "5.11.2", "status": "affected", "version": "5.11.x", "versionType": "custom" }, { "lessThan": "5.12.5", "status": "affected", "version": "5.12.x", "versionType": "custom" }, { "lessThan": "5.13.2", "status": "affected", "version": "5.13.x", "versionType": "custom" }, { "lessThan": "5.20.2", "status": "affected", "version": "5.20.x", "versionType": "custom" } ] }, { "product": "ICC16xx", "vendor": "Bender / ebee", "versions": [ { "lessThan": "5.11.2", "status": "affected", "version": "5.11.x", "versionType": "custom" }, { "lessThan": "5.12.5", "status": "affected", "version": "5.12.x", "versionType": "custom" }, { "lessThan": "5.13.2", "status": "affected", "version": "5.13.x", "versionType": "custom" }, { "lessThan": "5.20.2", "status": "affected", "version": "5.20.x", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Bender thanks the IT security researchers at OpenSource Security GmbH for their thorough and in-depth work. The issue was coordinated by CERT@VDE." } ], "datePublic": "2022-04-27T00:00:00", "descriptions": [ { "lang": "en", "value": "In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-27T15:15:23", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert.vde.com/en/advisories/VDE-2021-047" } ], "source": { "advisory": "VDE-2021-047", "defect": [ "CERT@VDE#64088" ], "discovery": "EXTERNAL" }, "title": "Bender Charge Controller: Long URL could lead to webserver crash", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2022-04-27T10:00:00.000Z", "ID": "CVE-2021-34587", "STATE": "PUBLIC", "TITLE": "Bender Charge Controller: Long URL could lead to webserver crash" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CC612", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "5.11.x", "version_value": "5.11.2" }, { "version_affected": "\u003c", "version_name": "5.12.x", "version_value": "5.12.5" }, { "version_affected": "\u003c", "version_name": "5.13.x", "version_value": "5.13.2" }, { "version_affected": "\u003c", "version_name": "5.20.x", "version_value": "5.20.2" } ] } }, { "product_name": "CC613", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "5.11.x", "version_value": "5.11.2" }, { "version_affected": "\u003c", "version_name": "5.12.x", "version_value": "5.12.5" }, { "version_affected": "\u003c", "version_name": "5.13.x", "version_value": "5.13.2" }, { "version_affected": "\u003c", "version_name": "5.20.x", "version_value": "5.20.2" } ] } }, { "product_name": "ICC15xx", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "5.11.x", "version_value": "5.11.2" }, { "version_affected": "\u003c", "version_name": "5.12.x", "version_value": "5.12.5" }, { "version_affected": "\u003c", "version_name": "5.13.x", "version_value": "5.13.2" }, { "version_affected": "\u003c", "version_name": "5.20.x", "version_value": "5.20.2" } ] } }, { "product_name": "ICC16xx", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "5.11.x", "version_value": "5.11.2" }, { "version_affected": "\u003c", "version_name": "5.12.x", "version_value": "5.12.5" }, { "version_affected": "\u003c", "version_name": "5.13.x", "version_value": "5.13.2" }, { "version_affected": "\u003c", "version_name": "5.20.x", "version_value": "5.20.2" } ] } } ] }, "vendor_name": "Bender / ebee" } ] } }, "credit": [ { "lang": "eng", "value": "Bender thanks the IT security researchers at OpenSource Security GmbH for their thorough and in-depth work. The issue was coordinated by CERT@VDE." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-121 Stack-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert.vde.com/en/advisories/VDE-2021-047", "refsource": "CONFIRM", "url": "https://cert.vde.com/en/advisories/VDE-2021-047" } ] }, "source": { "advisory": "VDE-2021-047", "defect": [ "CERT@VDE#64088" ], "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2021-34587", "datePublished": "2022-04-27T15:15:24.084444Z", "dateReserved": "2021-06-10T00:00:00", "dateUpdated": "2024-09-17T02:58:12.456Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2022-04-27 16:15
Modified
2024-11-21 06:10
Severity ?
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
Summary
In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable.
References
▶ | URL | Tags | |
---|---|---|---|
info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2021-047 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert.vde.com/en/advisories/VDE-2021-047 | Third Party Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:ibm:_ibm_rational_lifecycle_integration_adapter_for_windchill:1.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "CCBEC040-9566-45BE-9D03-D1E1A5762AAB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bender:cc612_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81AED2C8-71EE-4BFC-949C-D63F998CD1ED", "versionEndExcluding": "5.11.2", "versionStartIncluding": "5.11.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:bender:cc612_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "609125CC-4748-4507-8CF2-1752FF89B203", "versionEndExcluding": "5.12.5", "versionStartIncluding": "5.12.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:bender:cc612_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C6FEC2C0-7F12-434A-9070-9A0F19379D25", "versionEndExcluding": "5.13.2", "versionStartIncluding": "5.13.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:bender:cc612_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E80EBD0C-D852-4EF7-B0EA-89124683939C", "versionEndExcluding": "5.20.2", "versionStartIncluding": "5.20.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bender:cc612:-:*:*:*:*:*:*:*", "matchCriteriaId": "9B48F3A5-C59D-40B6-ADBB-76FA536C78FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bender:cc613_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "51E236CF-B4BA-4A59-BBA5-4A8DED0B1BE9", "versionEndExcluding": "5.11.2", "versionStartIncluding": "5.11.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:bender:cc613_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "651C5E8E-C1CE-4C03-BE87-C8CC0E988217", "versionEndExcluding": "5.12.5", "versionStartIncluding": "5.12.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:bender:cc613_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ABC385CD-C199-4E6C-A3E1-D0A5A140A52A", "versionEndExcluding": "5.13.2", "versionStartIncluding": "5.13.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:bender:cc613_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1501D9BB-A77D-42A0-9960-27F985922D08", "versionEndExcluding": "5.20.2", "versionStartIncluding": "5.20.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bender:cc613:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FEFDDEB-23FB-474C-9A91-EDA35837D34B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B078039-C644-42DE-8122-300415D69854", "versionEndExcluding": "5.11.2", "versionStartIncluding": "5.11.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D687057F-58C9-4463-BEF2-BE4CA428F9AD", "versionEndExcluding": "5.12.5", "versionStartIncluding": "5.12.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "88D208BE-6401-489E-BBE7-1ABBEB14CF52", "versionEndExcluding": "5.13.2", "versionStartIncluding": "5.13.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:bender:icc15xx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0B36AF92-1F52-45AA-BAAF-0D94EB0B2FF2", "versionEndExcluding": "5.20.2", "versionStartIncluding": "5.20.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bender:icc15xx:-:*:*:*:*:*:*:*", "matchCriteriaId": "2C449A16-8C53-46CB-AAAC-E42B41575309", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bender:icc16xx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6070DAAF-CB0D-485F-8CA7-3EC9485441B7", "versionEndExcluding": "5.11.2", "versionStartIncluding": "5.11.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:bender:icc16xx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "97D5D5D9-81DE-4987-8CC0-35591F23181B", "versionEndExcluding": "5.12.5", "versionStartIncluding": "5.12.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:bender:icc16xx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DEB49335-8FD8-451C-8D0B-7835983E0DFE", "versionEndExcluding": "5.13.2", "versionStartIncluding": "5.13.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:bender:icc16xx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9BE60DCB-35EA-47F1-9F60-4FFA275090AD", "versionEndExcluding": "5.20.2", "versionStartIncluding": "5.20.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bender:icc16xx:-:*:*:*:*:*:*:*", "matchCriteriaId": "B96EF215-8AD0-4076-8CBA-E6FA8F21A38E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable." }, { "lang": "es", "value": "En los Controladores de Carga Bender/ebee en m\u00faltiples versiones, una URL larga podr\u00eda conllevar a un bloqueo del servidor web. La URL es usada como entrada de un sprintf a una variable de pila" } ], "id": "CVE-2021-34587", "lastModified": "2024-11-21T06:10:45.670", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "info@cert.vde.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-04-27T16:15:10.617", "references": [ { "source": "info@cert.vde.com", "tags": [ "Third Party Advisory" ], "url": "https://cert.vde.com/en/advisories/VDE-2021-047" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://cert.vde.com/en/advisories/VDE-2021-047" } ], "sourceIdentifier": "info@cert.vde.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "info@cert.vde.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2014-12-12 03:03
Modified
2025-04-12 10:46
Severity ?
Summary
Session fixation vulnerability in IBM Rational Lifecycle Integration Adapter for Windchill 1.x before 1.0.1 allows remote attackers to hijack web sessions via unspecified vectors.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
ibm | _ibm_rational_lifecycle_integration_adapter_for_windchill | 1.0.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:ibm:_ibm_rational_lifecycle_integration_adapter_for_windchill:1.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "CCBEC040-9566-45BE-9D03-D1E1A5762AAB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Session fixation vulnerability in IBM Rational Lifecycle Integration Adapter for Windchill 1.x before 1.0.1 allows remote attackers to hijack web sessions via unspecified vectors." }, { "lang": "es", "value": "Vulnerabilidad de fijaci\u00f3n de sesi\u00f3n en IBM Rational Lifecycle Integration Adapter for Windchill 1.x anterior a 1.0.1 permite a atacantes remotos secuestrar sesiones web a trav\u00e9s de vectores no especificados." } ], "evaluatorComment": "\u003ca href=\"http://cwe.mitre.org/data/definitions/384.html\" target=\"_blank\"\u003eCWE-384: Session Fixation\u003c/a\u003e", "id": "CVE-2014-4815", "lastModified": "2025-04-12T10:46:40.837", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2014-12-12T03:03:18.267", "references": [ { "source": "psirt@us.ibm.com", "tags": [ "Vendor Advisory" ], "url": "http://www-01.ibm.com/support/docview.wss?uid=swg21691993" }, { "source": "psirt@us.ibm.com", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/95401" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://www-01.ibm.com/support/docview.wss?uid=swg21691993" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/95401" } ], "sourceIdentifier": "psirt@us.ibm.com", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }