Vulnerabilites related to tendacn - a301
CVE-2024-7581 (GCVE-0-2024-7581)
Vulnerability from cvelistv5
Published
2024-08-07 15:00
Modified
2024-08-07 15:40
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. This affects the function formWifiBasicSet of the file /goform/WifiBasicSet. The manipulation of the argument security leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:a301_firmware:15.13.08.12:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "a301_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.13.08.12" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-7581", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-07T15:40:05.246414Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-07T15:40:44.206Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "A301", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.13.08.12" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "BeaCox (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. This affects the function formWifiBasicSet of the file /goform/WifiBasicSet. The manipulation of the argument security leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda A301 15.13.08.12 entdeckt. Sie wurde als kritisch eingestuft. Hiervon betroffen ist die Funktion formWifiBasicSet der Datei /goform/WifiBasicSet. Mittels dem Manipulieren des Arguments security mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-07T15:00:09.496Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-273861 | Tenda A301 WifiBasicSet formWifiBasicSet stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.273861" }, { "name": "VDB-273861 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.273861" }, { "name": "Submit #382745 | Tenda A301 V15.13.08.12 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.382745" }, { "tags": [ "exploit" ], "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/A301/WifiBasicSet_bof" } ], "timeline": [ { "lang": "en", "time": "2024-08-07T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-08-07T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-08-07T08:57:59.000Z", "value": "VulDB entry last update" } ], "title": "Tenda A301 WifiBasicSet formWifiBasicSet stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-7581", "datePublished": "2024-08-07T15:00:09.496Z", "dateReserved": "2024-08-07T06:52:40.823Z", "dateUpdated": "2024-08-07T15:40:44.206Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-6189 (GCVE-0-2024-6189)
Vulnerability from cvelistv5
Published
2024-06-20 14:00
Modified
2024-08-01 21:33
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:a301:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "a301", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.13.08.12" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-6189", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-06-25T15:32:07.042197Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-25T15:40:00.073Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T21:33:05.173Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-269160 | Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.269160" }, { "name": "VDB-269160 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.269160" }, { "name": "Submit #355264 | Tenda A301V2.0 Firmware V15.13.08.12 Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.355264" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "A301", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.13.08.12" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "seuilping (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda A301 15.13.08.12 ausgemacht. Es betrifft die Funktion fromSetWirelessRepeat der Datei /goform/WifiExtraSet. Dank Manipulation des Arguments wpapsk_crypto mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-20T14:00:05.817Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-269160 | Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.269160" }, { "name": "VDB-269160 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.269160" }, { "name": "Submit #355264 | Tenda A301V2.0 Firmware V15.13.08.12 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.355264" }, { "tags": [ "exploit" ], "url": "https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd" } ], "timeline": [ { "lang": "en", "time": "2024-06-20T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-06-20T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-06-20T07:44:13.000Z", "value": "VulDB entry last update" } ], "title": "Tenda A301 WifiExtraSet fromSetWirelessRepeat stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-6189", "datePublished": "2024-06-20T14:00:05.817Z", "dateReserved": "2024-06-20T05:38:53.981Z", "dateUpdated": "2024-08-01T21:33:05.173Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-6402 (GCVE-0-2024-6402)
Vulnerability from cvelistv5
Published
2024-06-28 17:00
Modified
2024-08-01 21:41
Severity ?
7.1 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:a301_firmware:15.13.08.12:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "a301_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.13.08.12" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-6402", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-29T19:29:21.840575Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-29T19:30:25.108Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T21:41:03.185Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-269947 | Tenda A301 SetOnlineDevName fromSetWirelessRepeat stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.269947" }, { "name": "VDB-269947 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.269947" }, { "name": "Submit #360696 | Tenda A301V2.0 Firmware V15.13.08.12 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.360696" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "A301", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.13.08.12" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "dexter_zg (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda A301 15.13.08.12 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion fromSetWirelessRepeat der Datei /goform/SetOnlineDevName. Durch das Manipulieren des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.8, "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-28T17:00:05.443Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-269947 | Tenda A301 SetOnlineDevName fromSetWirelessRepeat stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.269947" }, { "name": "VDB-269947 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.269947" }, { "name": "Submit #360696 | Tenda A301V2.0 Firmware V15.13.08.12 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.360696" }, { "tags": [ "exploit" ], "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md" } ], "timeline": [ { "lang": "en", "time": "2024-06-28T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-06-28T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-06-28T14:19:48.000Z", "value": "VulDB entry last update" } ], "title": "Tenda A301 SetOnlineDevName fromSetWirelessRepeat stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-6402", "datePublished": "2024-06-28T17:00:05.443Z", "dateReserved": "2024-06-28T12:14:38.593Z", "dateUpdated": "2024-08-01T21:41:03.185Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-6403 (GCVE-0-2024-6403)
Vulnerability from cvelistv5
Published
2024-06-28 17:00
Modified
2024-08-01 21:41
Severity ?
7.1 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:a301_firmware:15.13.08.12:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "a301_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.13.08.12" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-6403", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-02T19:38:09.935913Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-08T20:33:19.325Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T21:41:03.307Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-269948 | Tenda A301 SetOnlineDevName formWifiBasicSet stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.269948" }, { "name": "VDB-269948 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.269948" }, { "name": "Submit #360752 | Tenda A301V2.0 A301V2.0 Firmware V15.13.08.12 Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.360752" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "A301", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.13.08.12" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "C9Y_57 (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda A301 15.13.08.12 entdeckt. Betroffen davon ist die Funktion formWifiBasicSet der Datei /goform/SetOnlineDevName. Durch Manipulieren des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.8, "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-28T17:00:07.083Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-269948 | Tenda A301 SetOnlineDevName formWifiBasicSet stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.269948" }, { "name": "VDB-269948 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.269948" }, { "name": "Submit #360752 | Tenda A301V2.0 A301V2.0 Firmware V15.13.08.12 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.360752" }, { "tags": [ "exploit" ], "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md" } ], "timeline": [ { "lang": "en", "time": "2024-06-28T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-06-28T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-06-28T14:19:50.000Z", "value": "VulDB entry last update" } ], "title": "Tenda A301 SetOnlineDevName formWifiBasicSet stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-6403", "datePublished": "2024-06-28T17:00:07.083Z", "dateReserved": "2024-06-28T12:14:41.333Z", "dateUpdated": "2024-08-01T21:41:03.307Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2024-08-07 15:15
Modified
2024-08-07 19:59
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. This affects the function formWifiBasicSet of the file /goform/WifiBasicSet. The manipulation of the argument security leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/BeaCox/IoT_vuln/tree/main/tenda/A301/WifiBasicSet_bof | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.273861 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.273861 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.382745 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tendacn | a301_firmware | 15.13.08.12 | |
tendacn | a301 | 2.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:a301_firmware:15.13.08.12:*:*:*:*:*:*:*", "matchCriteriaId": "C9D764F0-DC30-42AA-85BA-891AB544DD4D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:a301:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "0CF182E3-DCA1-45AC-AB73-E4CDFB7925C1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical has been found in Tenda A301 15.13.08.12. This affects the function formWifiBasicSet of the file /goform/WifiBasicSet. The manipulation of the argument security leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad ha sido encontrada en Tenda A301 15.13.08.12 y clasificada como cr\u00edtica. Esto afecta a la funci\u00f3n formWifiBasicSet del fichero /goform/WifiBasicSet. La manipulaci\u00f3n del argumento seguridad conduce a un desbordamiento del b\u00fafer basado en la pila. Es posible iniciar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-7581", "lastModified": "2024-08-07T19:59:00.853", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2024-08-07T15:15:56.787", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/BeaCox/IoT_vuln/tree/main/tenda/A301/WifiBasicSet_bof" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.273861" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.273861" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.382745" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-06-28 17:15
Modified
2024-11-21 09:49
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.269947 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.269947 | Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?submit.360696 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.269947 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.269947 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.360696 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tendacn | a301_firmware | 15.13.08.12 | |
tendacn | a301 | 2.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:a301_firmware:15.13.08.12:*:*:*:*:*:*:*", "matchCriteriaId": "C9D764F0-DC30-42AA-85BA-891AB544DD4D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:a301:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "0CF182E3-DCA1-45AC-AB73-E4CDFB7925C1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda A301 15.13.08.12. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-269947. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda A301 15.13.08.12 y clasificada como cr\u00edtica. La funci\u00f3n fromSetWirelessRepeat del archivo /goform/SetOnlineDevName es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento devName provoca un desbordamiento del b\u00fafer basado en pila. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-269947. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-6402", "lastModified": "2024-11-21T09:49:34.953", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 6.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2024-06-28T17:15:03.810", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.269947" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.269947" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?submit.360696" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.269947" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.269947" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?submit.360696" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-06-28 17:15
Modified
2024-11-21 09:49
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.269948 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.269948 | Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?submit.360752 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.269948 | Permissions Required | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.269948 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.360752 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tendacn | a301_firmware | 15.13.08.12 | |
tendacn | a301 | 2.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:a301_firmware:15.13.08.12:*:*:*:*:*:*:*", "matchCriteriaId": "C9D764F0-DC30-42AA-85BA-891AB544DD4D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:a301:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "0CF182E3-DCA1-45AC-AB73-E4CDFB7925C1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda A301 15.13.08.12. Affected by this issue is the function formWifiBasicSet of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269948. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda A301 15.13.08.12 y clasificada como cr\u00edtica. La funci\u00f3n formWifiBasicSet del archivo /goform/SetOnlineDevName es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento devName provoca un desbordamiento del b\u00fafer basado en pila. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-269948. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-6403", "lastModified": "2024-11-21T09:49:35.110", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 6.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2024-06-28T17:15:04.140", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.269948" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.269948" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?submit.360752" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/General-Offensive/iot_vuldb/blob/main/Tenda/A301/formSetDeviceName_devName.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.269948" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.269948" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?submit.360752" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-06-20 14:15
Modified
2024-11-21 09:49
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.269160 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.269160 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.355264 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.269160 | Permissions Required, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.269160 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.355264 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tendacn | a301_firmware | 15.13.08.12 | |
tendacn | a301 | 2.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tendacn:a301_firmware:15.13.08.12:*:*:*:*:*:*:*", "matchCriteriaId": "C9D764F0-DC30-42AA-85BA-891AB544DD4D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tendacn:a301:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "0CF182E3-DCA1-45AC-AB73-E4CDFB7925C1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda A301 15.13.08.12. Ha sido clasificada como cr\u00edtica. La funci\u00f3n fromSetWirelessRepeat del fichero /goform/WifiExtraSet es afectada por la vulnerabilidad. La manipulaci\u00f3n del argumento wpapsk_crypto provoca un desbordamiento del b\u00fafer basado en pila. Es posible lanzar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-269160. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-6189", "lastModified": "2024-11-21T09:49:09.203", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2024-06-20T14:15:12.370", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.269160" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.269160" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.355264" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://military-hail-377.notion.site/Tenda-A301V2-0-stack-overflow-c95f23f03b2b4eb5b8ffd3912e9982fd" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.269160" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.269160" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.355264" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }