Vulnerabilites related to tenda - ac7
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromAddressNat" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro page de la funci\u00f3n fromAddressNat para una petici\u00f3n POST, el valor se emplea directamente en una llamada sprintf a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18708", "lastModified": "2024-11-21T03:56:25.030", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:05.617", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-04-25 20:29
Modified
2024-11-21 03:49
Severity ?
Summary
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | * | |
tenda | ac7 | - | |
tenda | ac9_firmware | * | |
tenda | ac9 | - | |
tenda | ac10_firmware | * | |
tenda | ac10 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B16592CE-98A8-478A-94E1-DF628ADE67E7", "versionEndIncluding": "15.03.06.44_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73D523BB-7EB3-4125-90C4-4C85F4AE1815", "versionEndIncluding": "15.03.05.19\\(6318\\)_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9BDE03D1-5D87-4FCD-BB03-D483AB9BC186", "versionEndIncluding": "15.03.06.23_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow." }, { "lang": "es", "value": "Se descubri\u00f3 un problema en los dispositivos Tenda AC7 con firmware a trav\u00e9s de la versi\u00f3n V15.03.06.44_CN (AC7), dispositivos AC9 con firmware a trav\u00e9s de la versi\u00f3n V15.03.05.19 (6318) _CN (AC9), y dispositivos AC10 con firmware a trav\u00e9s de la versi\u00f3n V15.03.06.23_CN ( AC10). Existe una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router (httpd). Cuando son procesados los par\u00e1metros list para una solicitud post, el valor se escribe directamente con sprintf en una variable local colocada en la pila, que anula la direcci\u00f3n de retorno de la funci\u00f3n, lo que provoca un desbordamiento del b\u00fafer." } ], "id": "CVE-2018-14559", "lastModified": "2024-11-21T03:49:18.637", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-04-25T20:29:00.287", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | f1203_firmware | 2.0.1.6 | |
tenda | f1203 | - | |
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function." } ], "id": "CVE-2023-38930", "lastModified": "2024-11-21T08:14:27.803", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:10.907", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the 'mac' parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer basado en memoria din\u00e1mica (heap) en el servidor web del router, httpd. Al procesar el par\u00e1metro mac para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable en el heap, que puede filtrar informaci\u00f3n sensible o secuestrar el flujo de control del programa." } ], "id": "CVE-2018-18729", "lastModified": "2024-11-21T03:56:28.197", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 8.5, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:07.617", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceList' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro deviceList para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18727", "lastModified": "2024-11-21T03:56:27.863", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:07.400", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-26 19:15
Modified
2025-01-22 17:52
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWirelessRepeat.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257942 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.257942 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.300362 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWirelessRepeat.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257942 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257942 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.300362 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC7 15.03.06.44 y clasificada como cr\u00edtica. La funci\u00f3n fromSetWirelessRepeat del archivo /goform/WifiExtraSet es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento wpapsk_crypto provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-257942 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2899", "lastModified": "2025-01-22T17:52:49.950", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-26T19:15:49.410", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWirelessRepeat.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257942" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257942" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300362" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWirelessRepeat.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257942" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257942" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300362" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-05-16 21:15
Modified
2025-05-24 01:12
Severity ?
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://lavender-bicycle-a5a.notion.site/Tenda-AC7-formSetRebootTimer-1ed53a41781f80f78851c1c9dfc4f216?pvs=4 | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.309265 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.309265 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.573643 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC7 15.03.06.44. Se ha declarado cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n formSetRebootTimer del archivo /goform/SetRebootTimer. La manipulaci\u00f3n del argumento reboot_time provoca un desbordamiento del b\u00fafer en la pila. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-4810", "lastModified": "2025-05-24T01:12:25.480", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-05-16T21:15:35.583", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-formSetRebootTimer-1ed53a41781f80f78851c1c9dfc4f216?pvs=4" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.309265" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.309265" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.573643" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-26 18:15
Modified
2025-01-22 17:53
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257938 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.257938 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.300358 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257938 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257938 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.300358 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC7 15.03.06.44. Ha sido declarada cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n formWifiWpsOOB del archivo /goform/WifiWpsOOB. La manipulaci\u00f3n del \u00edndice de argumentos conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-257938 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2895", "lastModified": "2025-01-22T17:53:34.827", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-26T18:15:10.893", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257938" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257938" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300358" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257938" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257938" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300358" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-30 18:29
Modified
2025-03-20 21:03
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md | Exploit, Third Party Advisory, Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md | Exploit, Third Party Advisory, Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | * | |
tenda | ac7 | - | |
tenda | ac9_firmware | * | |
tenda | ac9 | - | |
tenda | ac10_firmware | * | |
tenda | ac10 | - |
{ "cisaActionDue": "2022-05-03", "cisaExploitAdd": "2021-11-03", "cisaRequiredAction": "Apply updates per vendor instructions.", "cisaVulnerabilityName": "Tenda AC7, AC9, and AC10 Routers Command Injection Vulnerability", "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B16592CE-98A8-478A-94E1-DF628ADE67E7", "versionEndIncluding": "15.03.06.44_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73D523BB-7EB3-4125-90C4-4C85F4AE1815", "versionEndIncluding": "15.03.05.19\\(6318\\)_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9BDE03D1-5D87-4FCD-BB03-D483AB9BC186", "versionEndIncluding": "15.03.06.23_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 con firmware hasta la versi\u00f3n V15.03.06.44_CN(AC7), dispositivos AC9 devices con firmware hasta la versi\u00f3n V15.03.05.19(6318)_CN(AC9) y dispositivos AC10 con firmware hasta la versi\u00f3n V15.03.06.23_CN(AC10). Una vulnerabilidad de inyecci\u00f3n de comandos permite que los atacantes ejecuten comandos arbitrarios del sistema operativo mediante una petici\u00f3n goform/setUsbUnload. Esto ocurre debido a que la funci\u00f3n \"formsetUsbUnload\" ejecuta una funci\u00f3n dosystemCmd con entradas no fiables." } ], "id": "CVE-2018-14558", "lastModified": "2025-03-20T21:03:53.180", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2018-10-30T18:29:00.580", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-10-28 20:15
Modified
2025-03-17 14:40
Severity ?
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda AC7 v.15.03.06.44 ate_ifconfig_set has pre-authentication command injection allowing remote attackers to execute arbitrary code.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ixout/iotVuls/blob/main/Tenda/ac7_005/report.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 v.15.03.06.44 ate_ifconfig_set has pre-authentication command injection allowing remote attackers to execute arbitrary code." }, { "lang": "es", "value": "Tenda AC7 v.15.03.06.44 ate_ifconfig_set tiene inyecci\u00f3n de comando de pre-autenticaci\u00f3n que permite a atacantes remotos ejecutar c\u00f3digo arbitrario." } ], "id": "CVE-2024-48825", "lastModified": "2025-03-17T14:40:19.617", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.0, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.1, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-10-28T20:15:06.173", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ixout/iotVuls/blob/main/Tenda/ac7_005/report.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-26 18:15
Modified
2025-01-22 17:53
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsStart.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257939 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.257939 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.300359 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsStart.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257939 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257939 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.300359 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC7 15.03.06.44. Ha sido calificada como cr\u00edtica. Este problema afecta a la funci\u00f3n formWifiWpsStart del archivo /goform/WifiWpsStart. La manipulaci\u00f3n del \u00edndice de argumentos conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-257939. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2896", "lastModified": "2025-01-22T17:53:24.233", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-26T18:15:11.543", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsStart.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257939" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257939" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300359" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsStart.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257939" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257939" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300359" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-03-02 17:15
Modified
2025-07-16 14:13
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/Raining-101/IOT_cve/blob/main/Tenda%20a7%20V15.03.06.44%20Command%20injection.md | Broken Link | |
cna@vuldb.com | https://vuldb.com/?ctiid.298092 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.298092 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.504429 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se ha detectado una vulnerabilidad clasificada como cr\u00edtica en Tenda AC7 1200M 15.03.06.44. La funci\u00f3n TendaTelnet del archivo /goform/telnet est\u00e1 afectada. La manipulaci\u00f3n del argumento lan_ip provoca la inyecci\u00f3n de comandos del sistema operativo. Es posible lanzar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse." } ], "id": "CVE-2025-1819", "lastModified": "2025-07-16T14:13:01.587", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.4, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "LOW", "vulnConfidentialityImpact": "LOW", "vulnIntegrityImpact": "LOW", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-03-02T17:15:11.483", "references": [ { "source": "cna@vuldb.com", "tags": [ "Broken Link" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/Tenda%20a7%20V15.03.06.44%20Command%20injection.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.298092" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.298092" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.504429" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" }, { "lang": "en", "value": "CWE-78" } ], "source": "cna@vuldb.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-03-03 05:15
Modified
2025-04-10 13:32
Severity ?
Summary
A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/Raining-101/IOT_cve/blob/main/ac7_V15.03.06.44_SetFirewallCfg.md | Broken Link | |
cna@vuldb.com | https://vuldb.com/?ctiid.298119 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.298119 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.505271 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product | |
134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://github.com/Raining-101/IOT_cve/blob/main/ac7_V15.03.06.44_SetFirewallCfg.md | Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | * | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3314DA98-9AA3-492C-9A65-C529585C4FC0", "versionEndExcluding": "15.03.06.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Hasta la versi\u00f3n 15.03.06.44 se ha detectado una vulnerabilidad clasificada como cr\u00edtica en Tenda AC7. Afecta a la funci\u00f3n formSetFirewallCfg del archivo /goform/SetFirewallCfg. La manipulaci\u00f3n del argumento firewallEn provoca un desbordamiento del b\u00fafer basado en la pila. Es posible iniciar el ataque de forma remota. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-1851", "lastModified": "2025-04-10T13:32:42.863", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Primary" } ] }, "published": "2025-03-03T05:15:10.867", "references": [ { "source": "cna@vuldb.com", "tags": [ "Broken Link" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/ac7_V15.03.06.44_SetFirewallCfg.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.298119" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.298119" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.505271" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "tags": [ "Broken Link" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/ac7_V15.03.06.44_SetFirewallCfg.md" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-03-24 21:15
Modified
2025-04-01 19:58
Severity ?
Summary
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function." }, { "lang": "es", "value": "Una vulnerabilidad de desbordamiento de b\u00fafer basada en pila en Tenda AC7 V15.03.06.44 permite a un atacante remoto ejecutar c\u00f3digo arbitrario a trav\u00e9s de un ataque de desbordamiento de pila utilizando el par\u00e1metro de seguridad de la funci\u00f3n formWifiBasicSet." } ], "id": "CVE-2025-29135", "lastModified": "2025-04-01T19:58:46.270", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-03-24T21:15:17.787", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://gist.github.com/Raining-101/1651dd3901efdbb38d94a156a54bbc62" }, { "source": "cve@mitre.org", "tags": [ "Exploit" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/a7_formWifiBasic_Setsecurity_stackoverflow.md" }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "tags": [ "Exploit" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/a7_formWifiBasic_Setsecurity_stackoverflow.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'ntpServer' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro ntpServer para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18732", "lastModified": "2024-11-21T03:56:28.703", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:07.960", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-06-09 05:15
Modified
2025-06-09 19:03
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://lavender-bicycle-a5a.notion.site/Tenda-AC7-fromadvsetlanip-20a53a41781f80038f4fc4b9d927eb9a?source=copy_link | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.311620 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.311620 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.591960 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product | |
134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://lavender-bicycle-a5a.notion.site/Tenda-AC7-fromadvsetlanip-20a53a41781f80038f4fc4b9d927eb9a | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se ha detectado una vulnerabilidad en Tenda AC7 15.03.06.44, clasificada como cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n fromadvsetlanip del archivo /goform/AdvSetLanip. La manipulaci\u00f3n del argumento lanMask provoca un desbordamiento del b\u00fafer. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-5861", "lastModified": "2025-06-09T19:03:01.067", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "PROOF_OF_CONCEPT", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-06-09T05:15:20.297", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-fromadvsetlanip-20a53a41781f80038f4fc4b9d927eb9a?source=copy_link" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.311620" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.311620" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.591960" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-fromadvsetlanip-20a53a41781f80038f4fc4b9d927eb9a" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-120" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'startIp' and 'endIp' parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar los par\u00e1metros startIp y endIp para una petici\u00f3n POST, cada valor se emplea directamente en una llamada sprintf a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18730", "lastModified": "2024-11-21T03:56:28.363", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:07.727", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-07-22 14:15
Modified
2025-08-01 20:02
Severity ?
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/Thir0th/Thir0th-CVE/blob/main/Tenda_AC7%20V1.0_V15.03.06.44%20has%20a%20stack%20overflow%20vulnerability%20in%20parse_macfilter_rule.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.317220 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.317220 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.619364 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC7 15.03.06.44. Se ha clasificado como cr\u00edtica. La funci\u00f3n formSetMacFilterCfg del archivo /goform/setMacFilterCfg del componente httpd est\u00e1 afectada. La manipulaci\u00f3n del argumento deviceList provoca un desbordamiento del b\u00fafer basado en la pila. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-8017", "lastModified": "2025-08-01T20:02:50.773", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "PROOF_OF_CONCEPT", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-07-22T14:15:48.403", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Thir0th/Thir0th-CVE/blob/main/Tenda_AC7%20V1.0_V15.03.06.44%20has%20a%20stack%20overflow%20vulnerability%20in%20parse_macfilter_rule.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.317220" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.317220" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.619364" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "ssid" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro ssid para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18707", "lastModified": "2024-11-21T03:56:24.870", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:05.507", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac10_firmware | 15.03.06.23 | |
tenda | ac10 | 1.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | f1203_firmware | 2.0.1.6 | |
tenda | f1203 | - | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | fh1203_firmware | 2.0.1.6 | |
tenda | fh1203 | - | |
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - | |
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function." } ], "id": "CVE-2023-38933", "lastModified": "2024-11-21T08:14:28.333", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:11.133", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/fromAddressNat/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/fromAddressNat/1.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat." } ], "id": "CVE-2023-41557", "lastModified": "2024-11-21T08:21:17.497", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-30T13:15:14.100", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromAddressNat/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromAddressNat/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-17 13:15
Modified
2025-03-17 14:35
Severity ?
Summary
Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formexecommand.md | Exploit, Third Party Advisory, Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formexecommand.md | Exploit, Third Party Advisory, Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter." }, { "lang": "es", "value": "El firmware Tenda AC7V1.0 v15.03.06.44 contiene una vulnerabilidad de inyecci\u00f3n de comandos en la funci\u00f3n formexeCommand a trav\u00e9s del par\u00e1metro cmdinput." } ], "id": "CVE-2024-32281", "lastModified": "2025-03-17T14:35:04.940", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-04-17T13:15:08.247", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formexecommand.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formexecommand.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/form_fast_setting_wifi_set/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/form_fast_setting_wifi_set/1.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac9_firmware | 5.03.06.42_multi | |
tenda | ac9 | 3.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:5.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "F4DB0137-7B0F-46BF-9178-83D695531170", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set." } ], "id": "CVE-2023-41552", "lastModified": "2024-11-21T08:21:16.707", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-30T13:15:13.087", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/form_fast_setting_wifi_set/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/form_fast_setting_wifi_set/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-10-23 14:15
Modified
2024-11-01 14:03
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md | Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.281555 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.281555 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.426417 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - | |
tenda | ac10u_firmware | 15.03.06.48 | |
tenda | ac10u_firmware | 15.03.06.49 | |
tenda | ac10u | - | |
tenda | ac500_firmware | 1.0.0.14 | |
tenda | ac500_firmware | 1.0.0.16 | |
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - | |
tenda | ac18_firmware | 15.03.05.05 | |
tenda | ac18_firmware | 15.03.05.19\(6318\) | |
tenda | ac18 | - | |
tenda | ac9_firmware | 15.03.2.13 | |
tenda | ac9_firmware | 15.03.05.14 | |
tenda | ac9_firmware | 15.03.05.19\(6318\) | |
tenda | ac9 | 1.0 | |
tenda | ac9_firmware | 15.03.06.42 | |
tenda | ac9 | 3.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac10_firmware | 16.03.10.13 | |
tenda | ac10_firmware | 16.03.10.20 | |
tenda | ac10 | 4.0 | |
tenda | ac10_firmware | 16.03.48.19 | |
tenda | ac10_firmware | 16.03.48.23 | |
tenda | ac10 | 5.0 | |
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8_firmware | 16.03.34.09 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*", "matchCriteriaId": "1C2AFD04-833D-4085-BAD6-32A2715FA785", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*", "matchCriteriaId": "0F101E88-BEA9-4017-9048-860DF3D1BBBC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10u:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDBE5E26-7967-4FDD-A29F-7740B29C4B8E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*", "matchCriteriaId": "61BA4026-93A8-4D83-815E-397A2EC0A279", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*", "matchCriteriaId": "816A7A37-5952-4B22-80F7-8CD09383E079", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*", "matchCriteriaId": "4D5CB727-FC6B-4212-A61E-2888A0DADFB0", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*", "matchCriteriaId": "3AC468E5-44D1-4B94-B308-C1025DB1BB7B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.13:*:*:*:*:*:*:*", "matchCriteriaId": "3473D6FD-4D42-46D0-9D96-F95D6D856E8E", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.14:*:*:*:*:*:*:*", "matchCriteriaId": "DA7503C5-02C6-4016-A4C6-414146719BFF", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*", "matchCriteriaId": "D8F25141-8B57-463D-AB97-F52C0143973C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42:*:*:*:*:*:*:*", "matchCriteriaId": "5B0A5168-9E0C-43F7-BF7B-3943A3316CB8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*", "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.20:*:*:*:*:*:*:*", "matchCriteriaId": "A19C486B-52A3-4C3E-851D-F349E8E0A706", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.48.19:*:*:*:*:*:*:*", "matchCriteriaId": "DABA74C0-297A-4372-B84D-00BA0D334318", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.48.23:*:*:*:*:*:*:*", "matchCriteriaId": "AC3020CA-7422-4B9A-AA7B-C2B1A03A4450", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:5.0:*:*:*:*:*:*:*", "matchCriteriaId": "2BCFFBD6-3DAD-4FEA-9B5D-D7CBFC36572D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*", "matchCriteriaId": "EE69F412-6FC7-470D-BC7E-B3AAC6B4585F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se ha detectado una vulnerabilidad en Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 y AC1206 hasta 20241022. Se ha calificado como problem\u00e1tica. Este problema afecta a la funci\u00f3n websReadEvent del archivo /goform/GetIPTV. La manipulaci\u00f3n del argumento Content-Length provoca la desreferenciaci\u00f3n de puntero nulo. El ataque puede iniciarse de forma remota. El exploit se ha hecho p\u00fablico y puede utilizarse." } ], "id": "CVE-2024-10280", "lastModified": "2024-11-01T14:03:20.267", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 6.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2024-10-23T14:15:04.500", "references": [ { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.281555" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.281555" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.426417" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-476" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac10_firmware | 15.03.06.23 | |
tenda | ac10 | 1.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | f1203_firmware | 2.0.1.6 | |
tenda | f1203 | - | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | ac10_firmware | 16.03.10.13 | |
tenda | ac10 | 4.0 | |
tenda | fh1203_firmware | 2.0.1.6 | |
tenda | fh1203 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*", "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function." } ], "id": "CVE-2023-38931", "lastModified": "2024-11-21T08:14:28.000", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:10.977", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac9_firmware | 5.03.06.42_multi | |
tenda | ac9 | 3.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:5.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "F4DB0137-7B0F-46BF-9178-83D695531170", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind." } ], "id": "CVE-2023-41556", "lastModified": "2024-11-21T08:21:17.330", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-30T13:15:13.697", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-07-14 00:15
Modified
2024-11-21 08:12
Severity ?
Summary
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | f1202_firmware | 1.2.0.20\(408\) | |
tenda | f1202 | - | |
tenda | fh1202_firmware | 1.2.0.19_en | |
tenda | fh1202 | - | |
tenda | f1202_firmware | 1.0br | |
tenda | f1202 | - | |
tenda | ac10_firmware | 1.0 | |
tenda | ac10 | - | |
tenda | ac1206_firmware | 1.0 | |
tenda | ac1206 | - | |
tenda | ac7_firmware | 1.0 | |
tenda | ac7 | - | |
tenda | ac5_firmware | 1.0 | |
tenda | ac5 | - | |
tenda | ac9_firmware | 3.0 | |
tenda | ac9 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "25D11FC4-85C7-4F6C-81A2-AF9CB6BE1507", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "37DF507C-5EDA-46A0-851E-ED8BC0B54F88", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.19_en:*:*:*:*:*:*:*", "matchCriteriaId": "C36B9BA7-B171-453D-951B-23CA2F19111A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "4A632A11-60A0-457C-A039-BED32F83BD52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1202_firmware:1.0br:*:*:*:*:*:*:*", "matchCriteriaId": "83FA7DD8-061F-4893-ADBB-1FD1E6849107", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "37DF507C-5EDA-46A0-851E-ED8BC0B54F88", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "54F7AF9E-E4EC-4060-B1F4-29A891970DDE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF48C35A-8042-4E7B-B672-8904B999E9AE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "FD539CFA-4D45-4776-9E62-66EB123456BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "6A71BB02-CEFA-4B73-8B24-D4217C261D39", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*", "matchCriteriaId": "0A74C4FD-76A0-4E7C-94E0-EC293F379DD2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "D7D1050F-CA28-4365-8C46-6D6AF7572EAA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient." } ], "id": "CVE-2023-37717", "lastModified": "2024-11-21T08:12:10.257", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-07-14T00:15:09.477", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-26 20:15
Modified
2025-01-22 17:51
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/saveParentControlInfo_deviceId.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257943 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.257943 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.300364 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/saveParentControlInfo_deviceId.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257943 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257943 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.300364 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC7 15.03.06.44 y clasificada como cr\u00edtica. Esto afecta a la funci\u00f3n saveParentControlInfo del archivo /goform/saveParentControlInfo. La manipulaci\u00f3n del argumento ID de dispositivo/hora/url conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible iniciar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-257943. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2900", "lastModified": "2025-01-22T17:51:57.717", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-26T20:15:10.500", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/saveParentControlInfo_deviceId.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257943" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257943" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300364" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/saveParentControlInfo_deviceId.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257943" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257943" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300364" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md | Exploit, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md | Exploit, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac10_firmware | 15.03.06.23 | |
tenda | ac10 | 1.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | f1203_firmware | 2.0.1.6 | |
tenda | f1203 | - | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | fh1203_firmware | 2.0.1.6 | |
tenda | fh1203 | - | |
tenda | fh1205_firmware | 2.0.0.7\(775\) | |
tenda | fh1205 | - | |
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*", "matchCriteriaId": "706158B7-6114-4AA8-A1A0-BB24119A3264", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E92D910-72BB-443F-9927-1E72AC8C8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function." } ], "id": "CVE-2023-38936", "lastModified": "2024-11-21T08:14:28.797", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:11.343", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Vendor Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Vendor Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-04-07 10:15
Modified
2025-05-27 14:22
Severity ?
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/CH13hh/tmp_store_cc/blob/main/AC7formSetPPTPServer/formSetPPTPServer.md | Broken Link | |
cna@vuldb.com | https://vuldb.com/?ctiid.303560 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.303560 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.551927 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC7 15.03.06.44. Se ha clasificado como cr\u00edtica. Este problema afecta a la funci\u00f3n formSetPPTPServer del archivo /goform/SetPptpServerCfg. La manipulaci\u00f3n del argumento pptp_server_start_ip/pptp_server_end_ip provoca un desbordamiento del b\u00fafer. El ataque puede ejecutarse remotamente. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-3346", "lastModified": "2025-05-27T14:22:29.283", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-04-07T10:15:15.153", "references": [ { "source": "cna@vuldb.com", "tags": [ "Broken Link" ], "url": "https://github.com/CH13hh/tmp_store_cc/blob/main/AC7formSetPPTPServer/formSetPPTPServer.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.303560" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.303560" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.551927" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-120" } ], "source": "cna@vuldb.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet." } ], "id": "CVE-2023-41562", "lastModified": "2024-11-21T08:21:18.267", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-30T13:15:14.573", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro page de la funci\u00f3n fromDhcpListClient para una petici\u00f3n, se emplea directamente en una llamada sprintf a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18706", "lastModified": "2024-11-21T03:56:24.723", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:05.400", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/fromSetSysTime/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/fromSetSysTime/1.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg." } ], "id": "CVE-2023-41558", "lastModified": "2024-11-21T08:21:17.650", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-30T13:15:14.190", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetSysTime/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetSysTime/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-26 19:15
Modified
2025-01-22 17:52
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetRouteStatic.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257941 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.257941 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.300361 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetRouteStatic.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257941 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257941 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.300361 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC7 15.03.06.44 y clasificada como cr\u00edtica. La funci\u00f3n fromSetRouteStatic del archivo /goform/SetStaticRouteCfg es afectada por esta vulnerabilidad. La manipulaci\u00f3n de la lista de argumentos provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-257941. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2898", "lastModified": "2025-01-22T17:52:16.723", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-26T19:15:49.130", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetRouteStatic.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257941" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257941" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300361" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetRouteStatic.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257941" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257941" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300361" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "firewallEn" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro firewallEn para una petici\u00f3n POST, el valor se emplea directamente en una llamada strcpy a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18709", "lastModified": "2024-11-21T03:56:25.177", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:05.727", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-26 20:15
Modified
2025-01-22 17:51
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/setSchedWifi.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257944 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.257944 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.300367 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/setSchedWifi.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257944 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257944 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.300367 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad ha sido encontrada en Tenda AC7 15.03.06.44 y clasificada como cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n setSchedWifi del archivo /goform/openSchedWifi. La manipulaci\u00f3n del argumento schedEndTime provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-257944. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2901", "lastModified": "2025-01-22T17:51:47.007", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-26T20:15:10.933", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/setSchedWifi.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257944" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257944" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300367" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/setSchedWifi.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257944" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257944" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300367" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-07-14 00:15
Modified
2024-11-21 08:12
Severity ?
Summary
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromRouteStatic/report.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromRouteStatic/report.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | f1202_firmware | 1.2.0.20\(408\) | |
tenda | f1202 | - | |
tenda | fh1202_firmware | 1.2.0.19_en | |
tenda | fh1202 | - | |
tenda | f1202_firmware | 1.0br | |
tenda | f1202 | - | |
tenda | ac7_firmware | 1.0 | |
tenda | ac7 | - | |
tenda | pw201a_firmware | - | |
tenda | pw201a | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "25D11FC4-85C7-4F6C-81A2-AF9CB6BE1507", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "37DF507C-5EDA-46A0-851E-ED8BC0B54F88", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.19_en:*:*:*:*:*:*:*", "matchCriteriaId": "C36B9BA7-B171-453D-951B-23CA2F19111A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "4A632A11-60A0-457C-A039-BED32F83BD52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1202_firmware:1.0br:*:*:*:*:*:*:*", "matchCriteriaId": "83FA7DD8-061F-4893-ADBB-1FD1E6849107", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "37DF507C-5EDA-46A0-851E-ED8BC0B54F88", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "FD539CFA-4D45-4776-9E62-66EB123456BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:pw201a_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFFCCB05-EB78-4E03-9D16-1391F0496E07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:pw201a:-:*:*:*:*:*:*:*", "matchCriteriaId": "7614AEA9-9216-4872-A29C-C51736516F54", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic." } ], "id": "CVE-2023-37714", "lastModified": "2024-11-21T08:12:09.720", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-07-14T00:15:09.340", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromRouteStatic/report.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromRouteStatic/report.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-26 17:15
Modified
2025-01-22 17:57
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257937 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.257937 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.300357 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257937 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257937 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.300357 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC7 15.03.06.44. Ha sido clasificada como cr\u00edtica. Esto afecta a la funci\u00f3n formSetQosBand del archivo /goform/SetNetControlList. La manipulaci\u00f3n de la lista de argumentos provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible iniciar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-257937. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2894", "lastModified": "2025-01-22T17:57:21.890", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-26T17:15:48.080", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257937" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257937" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300357" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257937" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257937" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300357" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-26 16:15
Modified
2025-01-22 17:58
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetCfm.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257935 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.257935 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.300355 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetCfm.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257935 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257935 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.300355 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad ha sido encontrada en Tenda AC7 15.03.06.44 y clasificada como cr\u00edtica. La funci\u00f3n formSetCfm del archivo /goform/setcfm es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento funcpara1 provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-257935. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2892", "lastModified": "2025-01-22T17:58:23.927", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-26T16:15:13.853", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetCfm.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257935" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257935" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300355" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetCfm.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257935" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257935" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300355" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-26 17:15
Modified
2025-01-22 17:58
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetDeviceName_devName.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257936 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.257936 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.300356 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetDeviceName_devName.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257936 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257936 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.300356 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC7 15.03.06.44 y clasificada como cr\u00edtica. La funci\u00f3n formSetDeviceName del archivo /goform/SetOnlineDevName es afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento devName provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede lanzarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-257936. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2893", "lastModified": "2025-01-22T17:58:17.153", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-26T17:15:47.810", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetDeviceName_devName.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257936" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257936" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300356" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetDeviceName_devName.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257936" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257936" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300356" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-26 14:15
Modified
2025-01-22 17:51
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formQuickIndex.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257934 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.257934 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.300354 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formQuickIndex.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257934 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257934 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.300354 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC7 15.03.06.44 y clasificada como cr\u00edtica. La funci\u00f3n formQuickIndex del fichero /goform/QuickIndex es afectada por la vulnerabilidad. La manipulaci\u00f3n del argumento PPPOEPassword provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible lanzar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-257934 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2891", "lastModified": "2025-01-22T17:51:29.227", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-26T14:15:09.530", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formQuickIndex.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257934" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257934" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300354" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formQuickIndex.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257934" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257934" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://vuldb.com/?submit.300354" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting." } ], "id": "CVE-2023-41559", "lastModified": "2024-11-21T08:21:17.803", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-30T13:15:14.280", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac10_firmware | 15.03.06.23 | |
tenda | ac10 | 1.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | ac10_firmware | 16.03.10.13 | |
tenda | ac10 | 4.0 | |
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*", "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function." } ], "id": "CVE-2023-38937", "lastModified": "2024-11-21T08:14:28.943", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:11.413", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-05-16 20:15
Modified
2025-05-24 01:11
Severity ?
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://lavender-bicycle-a5a.notion.site/Tenda-AC7-fromSafeSetMacFilter-1ed53a41781f80cbbf13c8d4cc405ed1?pvs=4 | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.309264 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.309264 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.573642 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC7 15.03.06.44. Se ha clasificado como cr\u00edtica. La funci\u00f3n fromSafeSetMacFilter del archivo /goform/setMacFilterCfg est\u00e1 afectada. La manipulaci\u00f3n del argumento deviceList provoca un desbordamiento del b\u00fafer basado en la pila. Es posible ejecutar el ataque de forma remota. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-4809", "lastModified": "2025-05-24T01:11:08.893", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-05-16T20:15:22.773", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-fromSafeSetMacFilter-1ed53a41781f80cbbf13c8d4cc405ed1?pvs=4" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.309264" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.309264" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.573642" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-30 13:15
Modified
2024-11-21 08:21
Severity ?
Summary
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/peris-navince/founded-0-days/blob/main/formWifiBasicSet/1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/peris-navince/founded-0-days/blob/main/formWifiBasicSet/1.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet." } ], "id": "CVE-2023-41555", "lastModified": "2024-11-21T08:21:17.177", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-30T13:15:13.560", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/formWifiBasicSet/1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/formWifiBasicSet/1.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-26 20:15
Modified
2025-01-22 17:51
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWifiGusetBasic.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257945 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.257945 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.300449 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWifiGusetBasic.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257945 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257945 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.300449 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad fue encontrada en Tenda AC7 15.03.06.44 y clasificada como cr\u00edtica. Este problema afecta a la funci\u00f3n SetWifiGusetBasic del archivo /goform/WifiGuestSet. La manipulaci\u00f3n del argumento shareSpeed provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-257945. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2902", "lastModified": "2025-01-22T17:51:36.857", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-26T20:15:11.203", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWifiGusetBasic.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257945" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257945" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300449" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWifiGusetBasic.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257945" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257945" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300449" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-26 21:15
Modified
2025-01-22 17:48
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/GetParentControlInfo.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257946 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.257946 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.300452 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/GetParentControlInfo.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257946 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257946 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.300452 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC7 15.03.06.44. Ha sido clasificada como cr\u00edtica. La funci\u00f3n GetParentControlInfo del fichero /goform/GetParentControlInfo es afectada por la vulnerabilidad. La manipulaci\u00f3n del argumento mac conduce a un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible lanzar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-257946 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2903", "lastModified": "2025-01-22T17:48:48.723", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-26T21:15:53.343", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/GetParentControlInfo.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257946" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257946" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300452" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/GetParentControlInfo.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257946" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257946" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300452" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2018-10-29 12:29
Modified
2024-11-21 03:56
Severity ?
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceMac' parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44_cn | |
tenda | ac7 | - | |
tenda | ac9_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac9 | - | |
tenda | ac10_firmware | 15.03.06.23_cn | |
tenda | ac10 | - | |
tenda | ac15_firmware | 15.03.05.19_cn | |
tenda | ac15 | - | |
tenda | ac18_firmware | 15.03.05.19\(6318\)_cn | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44_cn:*:*:*:*:*:*:*", "matchCriteriaId": "EA048307-E3FA-4868-81E2-489CBCD6D27F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "D433B9D2-8F7E-45B7-99EF-50E96B14B324", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23_cn:*:*:*:*:*:*:*", "matchCriteriaId": "39FE2B83-C4C4-4A4B-9F40-A6E340F067A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19_cn:*:*:*:*:*:*:*", "matchCriteriaId": "A7FDBF96-9556-4B5C-ADBD-ED5E83557159", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\)_cn:*:*:*:*:*:*:*", "matchCriteriaId": "9AA6A0CA-46AB-4C6F-B4F8-8F3A4D9A71F5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." }, { "lang": "es", "value": "Se ha descubierto un problema en dispositivos Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN y AC18 V15.03.05.19(6318)_CN. Es una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router, httpd. Al procesar el par\u00e1metro deviceMac para una petici\u00f3n POST, el valor se emplea directamente en una llamada sprintf a una variable local colocada en la pila, que sobrescribe la direcci\u00f3n de retorno de la funci\u00f3n." } ], "id": "CVE-2018-18731", "lastModified": "2024-11-21T03:56:28.527", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-10-29T12:29:07.837", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-07-14 00:15
Modified
2024-11-21 08:12
Severity ?
Summary
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | f1202_firmware | 1.2.0.20\(408\) | |
tenda | f1202 | - | |
tenda | fh1202_firmware | 1.2.0.19_en | |
tenda | fh1202 | - | |
tenda | f1202_firmware | 1.0br | |
tenda | f1202 | - | |
tenda | ac10_firmware | 1.0 | |
tenda | ac10 | - | |
tenda | ac1206_firmware | 1.0 | |
tenda | ac1206 | - | |
tenda | ac7_firmware | 1.0 | |
tenda | ac7 | - | |
tenda | ac5_firmware | 1.0 | |
tenda | ac5 | - | |
tenda | ac9_firmware | 3.0 | |
tenda | ac9 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\\(408\\):*:*:*:*:*:*:*", "matchCriteriaId": "25D11FC4-85C7-4F6C-81A2-AF9CB6BE1507", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "37DF507C-5EDA-46A0-851E-ED8BC0B54F88", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.19_en:*:*:*:*:*:*:*", "matchCriteriaId": "C36B9BA7-B171-453D-951B-23CA2F19111A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "4A632A11-60A0-457C-A039-BED32F83BD52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1202_firmware:1.0br:*:*:*:*:*:*:*", "matchCriteriaId": "83FA7DD8-061F-4893-ADBB-1FD1E6849107", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*", "matchCriteriaId": "37DF507C-5EDA-46A0-851E-ED8BC0B54F88", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "54F7AF9E-E4EC-4060-B1F4-29A891970DDE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF48C35A-8042-4E7B-B672-8904B999E9AE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "FD539CFA-4D45-4776-9E62-66EB123456BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "6A71BB02-CEFA-4B73-8B24-D4217C261D39", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*", "matchCriteriaId": "0A74C4FD-76A0-4E7C-94E0-EC293F379DD2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "D7D1050F-CA28-4365-8C46-6D6AF7572EAA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting." } ], "id": "CVE-2023-37716", "lastModified": "2024-11-21T08:12:10.067", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-07-14T00:15:09.430", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-03-26 19:15
Modified
2025-01-22 17:53
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257940. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWriteFacMac.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.257940 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.257940 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.300360 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWriteFacMac.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.257940 | Permissions Required, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.257940 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.300360 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257940. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad ha sido encontrada en Tenda AC7 15.03.06.44 y clasificada como cr\u00edtica. La funci\u00f3n formWriteFacMac del fichero /goform/WriteFacMac es afectada por la vulnerabilidad. La manipulaci\u00f3n del argumento mac conduce a la inyecci\u00f3n de comandos del sistema operativo. Es posible lanzar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-257940. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-2897", "lastModified": "2025-01-22T17:53:14.800", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.4, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-26T19:15:48.857", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWriteFacMac.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257940" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257940" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300360" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWriteFacMac.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.257940" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.257940" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.300360" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-17 13:15
Modified
2025-03-17 14:37
Severity ?
Summary
Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromWizardHandle.md | Exploit, Third Party Advisory, Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromWizardHandle.md | Exploit, Third Party Advisory, Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function." }, { "lang": "es", "value": "El firmware Tenda AC7V1.0 v15.03.06.44 tiene una vulnerabilidad de desbordamiento de pila a trav\u00e9s del par\u00e1metro PPW en la funci\u00f3n fromWizardHandle." } ], "id": "CVE-2024-32301", "lastModified": "2025-03-17T14:37:20.667", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-04-17T13:15:08.293", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromWizardHandle.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromWizardHandle.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-10-28 20:15
Modified
2025-03-17 14:41
Severity ?
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda AC7 v.15.03.06.44 ate_iwpriv_set has pre-authentication command injection allowing remote attackers to execute arbitrary code.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/ixout/iotVuls/blob/main/Tenda/ac7_006/report.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 v.15.03.06.44 ate_iwpriv_set has pre-authentication command injection allowing remote attackers to execute arbitrary code." }, { "lang": "es", "value": "Tenda AC7 v.15.03.06.44 ate_iwpriv_set tiene inyecci\u00f3n de comando de pre-autenticaci\u00f3n que permite a atacantes remotos ejecutar c\u00f3digo arbitrario." } ], "id": "CVE-2024-48826", "lastModified": "2025-03-17T14:41:08.920", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.0, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.1, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-10-28T20:15:06.237", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/ixout/iotVuls/blob/main/Tenda/ac7_006/report.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2025-06-09 05:15
Modified
2025-06-09 19:02
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://lavender-bicycle-a5a.notion.site/Tenda-AC7-formSetPPTPUserList-20a53a41781f806ca124cbdf99bff931?source=copy_link | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.311621 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.311621 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.591980 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product | |
134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://lavender-bicycle-a5a.notion.site/Tenda-AC7-formSetPPTPUserList-20a53a41781f806ca124cbdf99bff931 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC7 15.03.06.44, clasificada como cr\u00edtica. Este problema afecta a la funci\u00f3n formSetPPTPUserList del archivo /goform/setPptpUserList. La manipulaci\u00f3n de la lista de argumentos provoca un desbordamiento del b\u00fafer. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-5862", "lastModified": "2025-06-09T19:02:54.097", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "PROOF_OF_CONCEPT", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-06-09T05:15:21.887", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-formSetPPTPUserList-20a53a41781f806ca124cbdf99bff931?source=copy_link" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.311621" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.311621" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.591980" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-formSetPPTPUserList-20a53a41781f806ca124cbdf99bff931" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-120" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-04-25 20:29
Modified
2024-11-21 03:49
Severity ?
Summary
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | * | |
tenda | ac7 | - | |
tenda | ac9_firmware | * | |
tenda | ac9 | - | |
tenda | ac10_firmware | * | |
tenda | ac10 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B16592CE-98A8-478A-94E1-DF628ADE67E7", "versionEndIncluding": "15.03.06.44_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73D523BB-7EB3-4125-90C4-4C85F4AE1815", "versionEndIncluding": "15.03.05.19\\(6318\\)_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FD1430E-DC2E-4042-9389-1FD90ECDBE4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9BDE03D1-5D87-4FCD-BB03-D483AB9BC186", "versionEndIncluding": "15.03.06.23_cn", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow." }, { "lang": "es", "value": "Se descubri\u00f3 un problema en los dispositivos Tenda AC7 con firmware a trav\u00e9s de la versi\u00f3n V15.03.06.44_CN (AC7), dispositivos AC9 con firmware a trav\u00e9s de la versi\u00f3n V15.03.05.19 (6318) _CN (AC9), y dispositivos AC10 con firmware a trav\u00e9s de la versi\u00f3n V15.03.06.23_CN ( AC10). Existe una vulnerabilidad de desbordamiento de b\u00fafer en el servidor web del router (httpd). Cuando son procesados los par\u00e1metros page para una solicitud post, el valor se escribe directamente con sprintf hacia una variable local colocada en la pila, que anula la direcci\u00f3n de retorno de la funci\u00f3n, lo que provoca un desbordamiento del b\u00fafer." } ], "id": "CVE-2018-14557", "lastModified": "2024-11-21T03:49:18.313", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-04-25T20:29:00.240", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-03-19 16:15
Modified
2025-04-01 20:37
Severity ?
Summary
Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set function, which can cause RCE.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set function, which can cause RCE." }, { "lang": "es", "value": "Tenda AC7 V1.0 V15.03.06.44 encontr\u00f3 un desbordamiento de b\u00fafer causado por el par\u00e1metro timeZone en la funci\u00f3n form_fast_setting_wifi_set, que puede causar RCE." } ], "id": "CVE-2025-29137", "lastModified": "2025-04-01T20:37:02.110", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-03-19T16:15:31.677", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/tenda-ac7form_fast_setting_wifi_set%20timeZone.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
CVE-2024-2891 (GCVE-0-2024-2891)
Vulnerability from cvelistv5
Published
2024-03-26 14:00
Modified
2024-08-01 19:25
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2891", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-01T18:36:55.001433Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-01T18:37:43.390Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.202Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257934 | Tenda AC7 QuickIndex formQuickIndex stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257934" }, { "name": "VDB-257934 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257934" }, { "name": "Submit #300354 | Tenda AC7 AC7V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.300354" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formQuickIndex.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda AC7 15.03.06.44 gefunden. Sie wurde als kritisch eingestuft. Betroffen hiervon ist die Funktion formQuickIndex der Datei /goform/QuickIndex. Mittels Manipulieren des Arguments PPPOEPassword mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-26T14:00:07.492Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257934 | Tenda AC7 QuickIndex formQuickIndex stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257934" }, { "name": "VDB-257934 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257934" }, { "name": "Submit #300354 | Tenda AC7 AC7V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.300354" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formQuickIndex.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-26T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-26T10:30:30.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 QuickIndex formQuickIndex stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2891", "datePublished": "2024-03-26T14:00:07.492Z", "dateReserved": "2024-03-26T09:25:25.245Z", "dateUpdated": "2024-08-01T19:25:42.202Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-32281 (GCVE-0-2024-32281)
Vulnerability from cvelistv5
Published
2024-04-17 00:00
Modified
2024-08-02 02:06
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-32281", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-01T15:41:09.439899Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-77", "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:52:08.614Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T02:06:44.067Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formexecommand.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-17T13:07:00.975833", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formexecommand.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-32281", "datePublished": "2024-04-17T00:00:00", "dateReserved": "2024-04-12T00:00:00", "dateUpdated": "2024-08-02T02:06:44.067Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5862 (GCVE-0-2025-5862)
Vulnerability from cvelistv5
Published
2025-06-09 05:00
Modified
2025-06-09 13:23
Severity ?
VLAI Severity ?
EPSS score ?
Summary
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5862", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-06-09T13:23:54.451652Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-09T13:23:57.463Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-formSetPPTPUserList-20a53a41781f806ca124cbdf99bff931" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda AC7 15.03.06.44 gefunden. Es geht hierbei um die Funktion formSetPPTPUserList der Datei /goform/setPptpUserList. Mit der Manipulation des Arguments list mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-09T05:00:20.243Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-311621 | Tenda AC7 setPptpUserList formSetPPTPUserList buffer overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.311621" }, { "name": "VDB-311621 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.311621" }, { "name": "Submit #591980 | Tenda AC7 V1.0 V15.03.06.44 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.591980" }, { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-formSetPPTPUserList-20a53a41781f806ca124cbdf99bff931?source=copy_link" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-06-08T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-06-08T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-06-08T15:30:36.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 setPptpUserList formSetPPTPUserList buffer overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-5862", "datePublished": "2025-06-09T05:00:20.243Z", "dateReserved": "2025-06-08T13:25:28.966Z", "dateUpdated": "2025-06-09T13:23:57.463Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-8017 (GCVE-0-2025-8017)
Vulnerability from cvelistv5
Published
2025-07-22 13:32
Modified
2025-07-22 13:47
Severity ?
VLAI Severity ?
EPSS score ?
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-8017", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-07-22T13:47:30.375394Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-07-22T13:47:43.904Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "modules": [ "httpd" ], "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "liuchangwei (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 ausgemacht. Es betrifft die Funktion formSetMacFilterCfg der Datei /goform/setMacFilterCfg der Komponente httpd. Mit der Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-22T13:32:07.104Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-317220 | Tenda AC7 httpd setMacFilterCfg formSetMacFilterCfg stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.317220" }, { "name": "VDB-317220 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.317220" }, { "name": "Submit #619364 | Tenda AC7 \u003c= Firmware v1.0_v15.03.06.44 RCE", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.619364" }, { "tags": [ "exploit" ], "url": "https://github.com/Thir0th/Thir0th-CVE/blob/main/Tenda_AC7%20V1.0_V15.03.06.44%20has%20a%20stack%20overflow%20vulnerability%20in%20parse_macfilter_rule.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-07-22T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-07-22T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-07-22T09:21:05.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 httpd setMacFilterCfg formSetMacFilterCfg stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-8017", "datePublished": "2025-07-22T13:32:07.104Z", "dateReserved": "2025-07-22T07:15:51.690Z", "dateUpdated": "2025-07-22T13:47:43.904Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-29135 (GCVE-0-2025-29135)
Vulnerability from cvelistv5
Published
2025-03-24 00:00
Modified
2025-03-26 14:35
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-29135", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-26T14:34:36.298519Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-26T14:35:07.458Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/a7_formWifiBasic_Setsecurity_stackoverflow.md" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-24T20:42:53.302Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Raining-101/IOT_cve/blob/main/a7_formWifiBasic_Setsecurity_stackoverflow.md" }, { "url": "https://gist.github.com/Raining-101/1651dd3901efdbb38d94a156a54bbc62" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-29135", "datePublished": "2025-03-24T00:00:00.000Z", "dateReserved": "2025-03-11T00:00:00.000Z", "dateUpdated": "2025-03-26T14:35:07.458Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-2903 (GCVE-0-2024-2903)
Vulnerability from cvelistv5
Published
2024-03-26 20:31
Modified
2024-08-15 15:54
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.219Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257946 | Tenda AC7 GetParentControlInfo stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257946" }, { "name": "VDB-257946 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257946" }, { "name": "Submit #300452 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.300452" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/GetParentControlInfo.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2903", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-15T15:52:57.072819Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-15T15:54:17.573Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 ausgemacht. Hiervon betroffen ist die Funktion GetParentControlInfo der Datei /goform/GetParentControlInfo. Durch das Manipulieren des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-26T20:31:04.040Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257946 | Tenda AC7 GetParentControlInfo stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257946" }, { "name": "VDB-257946 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257946" }, { "name": "Submit #300452 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.300452" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/GetParentControlInfo.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-26T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-26T10:31:50.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 GetParentControlInfo stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2903", "datePublished": "2024-03-26T20:31:04.040Z", "dateReserved": "2024-03-26T09:26:47.360Z", "dateUpdated": "2024-08-15T15:54:17.573Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-2893 (GCVE-0-2024-2893)
Vulnerability from cvelistv5
Published
2024-03-26 16:31
Modified
2024-08-12 13:37
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.172Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257936 | Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257936" }, { "name": "VDB-257936 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257936" }, { "name": "Submit #300356 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.300356" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetDeviceName_devName.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2893", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-15T19:38:25.903653Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-12T13:37:09.831Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC7 15.03.06.44 gefunden. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion formSetDeviceName der Datei /goform/SetOnlineDevName. Durch Manipulieren des Arguments devName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-26T16:31:04.545Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257936 | Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257936" }, { "name": "VDB-257936 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257936" }, { "name": "Submit #300356 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.300356" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetDeviceName_devName.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-26T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-26T10:30:40.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 SetOnlineDevName formSetDeviceName stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2893", "datePublished": "2024-03-26T16:31:04.545Z", "dateReserved": "2024-03-26T09:25:34.223Z", "dateUpdated": "2024-08-12T13:37:09.831Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-2901 (GCVE-0-2024-2901)
Vulnerability from cvelistv5
Published
2024-03-26 20:00
Modified
2024-08-29 19:09
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.161Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257944 | Tenda AC7 openSchedWifi setSchedWifi stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257944" }, { "name": "VDB-257944 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257944" }, { "name": "Submit #300367 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.300367" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/setSchedWifi.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2901", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-20T20:50:19.200809Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-29T19:09:39.749Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC7 15.03.06.44 wurde eine kritische Schwachstelle gefunden. Hierbei betrifft es die Funktion setSchedWifi der Datei /goform/openSchedWifi. Mittels dem Manipulieren des Arguments schedEndTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-26T20:00:06.887Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257944 | Tenda AC7 openSchedWifi setSchedWifi stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257944" }, { "name": "VDB-257944 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257944" }, { "name": "Submit #300367 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.300367" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/setSchedWifi.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-26T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-26T10:31:39.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 openSchedWifi setSchedWifi stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2901", "datePublished": "2024-03-26T20:00:06.887Z", "dateReserved": "2024-03-26T09:26:24.727Z", "dateUpdated": "2024-08-29T19:09:39.749Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-38930 (GCVE-0-2023-38930)
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-15 19:35
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.646Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0,V15.03.06.44" }, { "status": "affected", "version": "F1203 V2.0.1.6," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0,V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0,V15.03.06.42_multi" }, { "status": "affected", "version": "FH1205 V2.0.0.7(775)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38930", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-15T19:31:04.398117Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-15T19:35:44.164Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/addWifiMacFilter/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38930", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-15T19:35:44.164Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-38936 (GCVE-0-2023-38936)
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-15 20:05
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.689Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.0.7(775)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38936", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-15T20:02:03.283677Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-15T20:05:36.911Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38936", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-15T20:05:36.911Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-2898 (GCVE-0-2024-2898)
Vulnerability from cvelistv5
Published
2024-03-26 18:31
Modified
2024-08-01 19:25
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2898", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-16T21:02:27.145376Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-16T21:03:00.476Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.160Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257941 | Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257941" }, { "name": "VDB-257941 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257941" }, { "name": "Submit #300361 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.300361" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetRouteStatic.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC7 15.03.06.44 wurde eine kritische Schwachstelle entdeckt. Das betrifft die Funktion fromSetRouteStatic der Datei /goform/SetStaticRouteCfg. Mit der Manipulation des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-26T18:31:05.622Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257941 | Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257941" }, { "name": "VDB-257941 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257941" }, { "name": "Submit #300361 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.300361" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetRouteStatic.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-26T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-26T10:31:07.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 SetStaticRouteCfg fromSetRouteStatic stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2898", "datePublished": "2024-03-26T18:31:05.622Z", "dateReserved": "2024-03-26T09:26:00.834Z", "dateUpdated": "2024-08-01T19:25:42.160Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-32301 (GCVE-0-2024-32301)
Vulnerability from cvelistv5
Published
2024-04-17 00:00
Modified
2024-10-25 20:11
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-32301", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-06-13T19:36:42.677995Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125 Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-25T20:11:07.556Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T02:06:44.023Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromWizardHandle.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-17T13:01:42.760399", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromWizardHandle.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-32301", "datePublished": "2024-04-17T00:00:00", "dateReserved": "2024-04-12T00:00:00", "dateUpdated": "2024-10-25T20:11:07.556Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-18729 (GCVE-0-2018-18729)
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router's web server -- httpd. While processing the 'mac' parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.404Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18729", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a heap-based buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027mac\u0027 parameter for a post request, the value is directly used in a strcpy to a variable placed on the heap, which can leak sensitive information or even hijack program control flow." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/heapoverflow1.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18729", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.404Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-10280 (GCVE-0-2024-10280)
Vulnerability from cvelistv5
Published
2024-10-23 13:31
Modified
2024-10-23 17:41
Severity ?
7.1 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-476 - NULL Pointer Dereference
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.09" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.48.23" }, { "status": "affected", "version": "16.03.48.19" }, { "status": "affected", "version": "16.03.48.20" }, { "status": "affected", "version": "16.03.48.13" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.42" }, { "status": "affected", "version": "15.03.05.19\\(6318_\\)" }, { "status": "affected", "version": "15.03.05.14" }, { "status": "affected", "version": "15.03.2.13" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac18_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.05" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac18_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.19\\(6318\\)" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.1.9\\(1307\\)" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.16" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10u_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.48" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10u_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.49" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.19" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-10280", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-10-23T17:28:19.760214Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-23T17:41:57.370Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC6", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC9", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC10", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC10U", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC18", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC500", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC1206", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "minipython (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.8, "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-23T13:31:07.315Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.281555" }, { "name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.281555" }, { "name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.426417" }, { "tags": [ "exploit" ], "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2024-10-23T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-10-23T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-10-23T08:07:55.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-10280", "datePublished": "2024-10-23T13:31:07.315Z", "dateReserved": "2024-10-23T06:02:03.363Z", "dateUpdated": "2024-10-23T17:41:57.370Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-41557 (GCVE-0-2023-41557)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 19:36
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:01:35.298Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromAddressNat/1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0_v15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0rtl_v15.03.06.28" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-41557", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-01T19:35:12.448972Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-01T19:36:24.229Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-30T12:23:38.395267", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromAddressNat/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-41557", "datePublished": "2023-08-30T00:00:00", "dateReserved": "2023-08-30T00:00:00", "dateUpdated": "2024-10-01T19:36:24.229Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-18707 (GCVE-0-2018-18707)
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "ssid" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
► | URL | Tags |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.407Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-27T22:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18707", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"ssid\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-07/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18707", "datePublished": "2018-10-27T22:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.407Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-2902 (GCVE-0-2024-2902)
Vulnerability from cvelistv5
Published
2024-03-26 20:00
Modified
2024-08-12 13:35
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.155Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257945 | Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257945" }, { "name": "VDB-257945 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257945" }, { "name": "Submit #300449 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.300449" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWifiGusetBasic.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2902", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-15T19:37:20.952602Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-12T13:35:50.633Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda AC7 15.03.06.44 gefunden. Davon betroffen ist die Funktion fromSetWifiGusetBasic der Datei /goform/WifiGuestSet. Mittels Manipulieren des Arguments shareSpeed mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-26T20:00:08.534Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257945 | Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257945" }, { "name": "VDB-257945 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257945" }, { "name": "Submit #300449 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.300449" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWifiGusetBasic.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-26T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-26T10:31:44.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 WifiGuestSet fromSetWifiGusetBasic stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2902", "datePublished": "2024-03-26T20:00:08.534Z", "dateReserved": "2024-03-26T09:26:38.442Z", "dateUpdated": "2024-08-12T13:35:50.633Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-2895 (GCVE-0-2024-2895)
Vulnerability from cvelistv5
Published
2024-03-26 17:31
Modified
2024-08-01 19:25
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2895", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-06-05T19:51:36.570635Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-05T19:52:13.147Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.160Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257938 | Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257938" }, { "name": "VDB-257938 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257938" }, { "name": "Submit #300358 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.300358" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC7 15.03.06.44 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion formWifiWpsOOB der Datei /goform/WifiWpsOOB. Durch Beeinflussen des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-26T17:31:04.304Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257938 | Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257938" }, { "name": "VDB-257938 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257938" }, { "name": "Submit #300358 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.300358" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsOOB.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-26T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-26T10:30:51.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 WifiWpsOOB formWifiWpsOOB stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2895", "datePublished": "2024-03-26T17:31:04.304Z", "dateReserved": "2024-03-26T09:25:44.223Z", "dateUpdated": "2024-08-01T19:25:42.160Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-4810 (GCVE-0-2025-4810)
Vulnerability from cvelistv5
Published
2025-05-16 20:31
Modified
2025-05-17 02:25
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-4810", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-05-17T02:24:15.430149Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-05-17T02:25:49.517Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "In Tenda AC7 15.03.06.44 wurde eine kritische Schwachstelle ausgemacht. Es geht um die Funktion formSetRebootTimer der Datei /goform/SetRebootTimer. Dank der Manipulation des Arguments reboot_time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-05-16T20:31:06.542Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-309265 | Tenda AC7 SetRebootTimer formSetRebootTimer stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.309265" }, { "name": "VDB-309265 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.309265" }, { "name": "Submit #573643 | Tenda AC7 V1.0 V15.03.06.44 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.573643" }, { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-formSetRebootTimer-1ed53a41781f80f78851c1c9dfc4f216?pvs=4" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-05-16T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-05-16T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-05-16T10:49:18.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 SetRebootTimer formSetRebootTimer stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-4810", "datePublished": "2025-05-16T20:31:06.542Z", "dateReserved": "2025-05-16T08:44:12.481Z", "dateUpdated": "2025-05-17T02:25:49.517Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-37714 (GCVE-0-2023-37714)
Vulnerability from cvelistv5
Published
2023-07-14 00:00
Modified
2024-10-30 15:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:23:26.313Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromRouteStatic/report.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1202", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0BR_V1.2.0.20(408)" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1202", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.2.0.19_EN" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37714", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-30T15:46:41.128360Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-30T15:47:50.206Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromRouteStatic." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-14T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromRouteStatic/report.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-37714", "datePublished": "2023-07-14T00:00:00", "dateReserved": "2023-07-10T00:00:00", "dateUpdated": "2024-10-30T15:47:50.206Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-18731 (GCVE-0-2018-18731)
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceMac' parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.376Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18731", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceMac\u0027 parameter for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack4.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18731", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.376Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5861 (GCVE-0-2025-5861)
Vulnerability from cvelistv5
Published
2025-06-09 04:31
Modified
2025-06-09 13:24
Severity ?
VLAI Severity ?
EPSS score ?
Summary
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5861", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-06-09T13:24:25.807553Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-09T13:24:28.589Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-fromadvsetlanip-20a53a41781f80038f4fc4b9d927eb9a" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_backup (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "In Tenda AC7 15.03.06.44 wurde eine kritische Schwachstelle gefunden. Es geht um die Funktion fromadvsetlanip der Datei /goform/AdvSetLanip. Dank Manipulation des Arguments lanMask mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-09T04:31:06.939Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-311620 | Tenda AC7 AdvSetLanip fromadvsetlanip buffer overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.311620" }, { "name": "VDB-311620 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.311620" }, { "name": "Submit #591960 | Tenda AC7 V1.0 V15.03.06.44 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.591960" }, { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-fromadvsetlanip-20a53a41781f80038f4fc4b9d927eb9a?source=copy_link" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-06-08T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-06-08T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-06-08T15:30:34.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 AdvSetLanip fromadvsetlanip buffer overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-5861", "datePublished": "2025-06-09T04:31:06.939Z", "dateReserved": "2025-06-08T13:25:26.572Z", "dateUpdated": "2025-06-09T13:24:28.589Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-18708 (GCVE-0-2018-18708)
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromAddressNat" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
► | URL | Tags |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.428Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-27T22:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18708", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromAddressNat\" for a post request, the value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-05/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18708", "datePublished": "2018-10-27T22:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.428Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-1851 (GCVE-0-2025-1851)
Vulnerability from cvelistv5
Published
2025-03-03 05:00
Modified
2025-03-03 17:19
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
Summary
A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Tenda | AC7 |
Version: 15.03.06.0 Version: 15.03.06.1 Version: 15.03.06.2 Version: 15.03.06.3 Version: 15.03.06.4 Version: 15.03.06.5 Version: 15.03.06.6 Version: 15.03.06.7 Version: 15.03.06.8 Version: 15.03.06.9 Version: 15.03.06.10 Version: 15.03.06.11 Version: 15.03.06.12 Version: 15.03.06.13 Version: 15.03.06.14 Version: 15.03.06.15 Version: 15.03.06.16 Version: 15.03.06.17 Version: 15.03.06.18 Version: 15.03.06.19 Version: 15.03.06.20 Version: 15.03.06.21 Version: 15.03.06.22 Version: 15.03.06.23 Version: 15.03.06.24 Version: 15.03.06.25 Version: 15.03.06.26 Version: 15.03.06.27 Version: 15.03.06.28 Version: 15.03.06.29 Version: 15.03.06.30 Version: 15.03.06.31 Version: 15.03.06.32 Version: 15.03.06.33 Version: 15.03.06.34 Version: 15.03.06.35 Version: 15.03.06.36 Version: 15.03.06.37 Version: 15.03.06.38 Version: 15.03.06.39 Version: 15.03.06.40 Version: 15.03.06.41 Version: 15.03.06.42 Version: 15.03.06.43 Version: 15.03.06.44 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-1851", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-03T17:19:37.187929Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-03T17:19:41.764Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/ac7_V15.03.06.44_SetFirewallCfg.md" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.0" }, { "status": "affected", "version": "15.03.06.1" }, { "status": "affected", "version": "15.03.06.2" }, { "status": "affected", "version": "15.03.06.3" }, { "status": "affected", "version": "15.03.06.4" }, { "status": "affected", "version": "15.03.06.5" }, { "status": "affected", "version": "15.03.06.6" }, { "status": "affected", "version": "15.03.06.7" }, { "status": "affected", "version": "15.03.06.8" }, { "status": "affected", "version": "15.03.06.9" }, { "status": "affected", "version": "15.03.06.10" }, { "status": "affected", "version": "15.03.06.11" }, { "status": "affected", "version": "15.03.06.12" }, { "status": "affected", "version": "15.03.06.13" }, { "status": "affected", "version": "15.03.06.14" }, { "status": "affected", "version": "15.03.06.15" }, { "status": "affected", "version": "15.03.06.16" }, { "status": "affected", "version": "15.03.06.17" }, { "status": "affected", "version": "15.03.06.18" }, { "status": "affected", "version": "15.03.06.19" }, { "status": "affected", "version": "15.03.06.20" }, { "status": "affected", "version": "15.03.06.21" }, { "status": "affected", "version": "15.03.06.22" }, { "status": "affected", "version": "15.03.06.23" }, { "status": "affected", "version": "15.03.06.24" }, { "status": "affected", "version": "15.03.06.25" }, { "status": "affected", "version": "15.03.06.26" }, { "status": "affected", "version": "15.03.06.27" }, { "status": "affected", "version": "15.03.06.28" }, { "status": "affected", "version": "15.03.06.29" }, { "status": "affected", "version": "15.03.06.30" }, { "status": "affected", "version": "15.03.06.31" }, { "status": "affected", "version": "15.03.06.32" }, { "status": "affected", "version": "15.03.06.33" }, { "status": "affected", "version": "15.03.06.34" }, { "status": "affected", "version": "15.03.06.35" }, { "status": "affected", "version": "15.03.06.36" }, { "status": "affected", "version": "15.03.06.37" }, { "status": "affected", "version": "15.03.06.38" }, { "status": "affected", "version": "15.03.06.39" }, { "status": "affected", "version": "15.03.06.40" }, { "status": "affected", "version": "15.03.06.41" }, { "status": "affected", "version": "15.03.06.42" }, { "status": "affected", "version": "15.03.06.43" }, { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "Raining101 (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda AC7 bis 15.03.06.44 gefunden. Betroffen hiervon ist die Funktion formSetFirewallCfg der Datei /goform/SetFirewallCfg. Durch Manipulieren des Arguments firewallEn mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-03T05:00:07.574Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-298119 | Tenda AC7 SetFirewallCfg formSetFirewallCfg stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.298119" }, { "name": "VDB-298119 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.298119" }, { "name": "Submit #505271 | Tenda ac7 V15.03.06.44 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.505271" }, { "tags": [ "exploit" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/ac7_V15.03.06.44_SetFirewallCfg.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-03-02T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-03-02T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-03-02T21:09:38.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 SetFirewallCfg formSetFirewallCfg stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-1851", "datePublished": "2025-03-03T05:00:07.574Z", "dateReserved": "2025-03-02T20:04:35.439Z", "dateUpdated": "2025-03-03T17:19:41.764Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-37716 (GCVE-0-2023-37716)
Vulnerability from cvelistv5
Published
2023-07-14 00:00
Modified
2024-10-30 15:44
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:23:26.317Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1202", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0BR_V1.2.0.20(408)" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1202", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.2.0.19_EN" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v.1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v3.0" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37716", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-30T15:41:48.422746Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-30T15:44:13.700Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-14T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromNatStaticSetting/report.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-37716", "datePublished": "2023-07-14T00:00:00", "dateReserved": "2023-07-10T00:00:00", "dateUpdated": "2024-10-30T15:44:13.700Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-2894 (GCVE-0-2024-2894)
Vulnerability from cvelistv5
Published
2024-03-26 17:00
Modified
2024-08-15 18:17
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.177Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257937 | Tenda AC7 SetNetControlList formSetQosBand stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257937" }, { "name": "VDB-257937 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257937" }, { "name": "Submit #300357 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.300357" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2894", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-15T18:15:35.740727Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-15T18:17:10.564Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda AC7 15.03.06.44 ausgemacht. Sie wurde als kritisch eingestuft. Es geht dabei um die Funktion formSetQosBand der Datei /goform/SetNetControlList. Durch das Beeinflussen des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-26T17:00:07.831Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257937 | Tenda AC7 SetNetControlList formSetQosBand stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257937" }, { "name": "VDB-257937 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257937" }, { "name": "Submit #300357 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.300357" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetQosBand.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-26T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-26T10:30:46.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 SetNetControlList formSetQosBand stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2894", "datePublished": "2024-03-26T17:00:07.831Z", "dateReserved": "2024-03-26T09:25:39.103Z", "dateUpdated": "2024-08-15T18:17:10.564Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-2897 (GCVE-0-2024-2897)
Vulnerability from cvelistv5
Published
2024-03-26 18:31
Modified
2024-08-01 19:25
Severity ?
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
VLAI Severity ?
EPSS score ?
CWE
- CWE-78 - OS Command Injection
Summary
A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257940. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-2897", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-04-15T14:30:45.791519Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:30:55.078Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.169Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257940 | Tenda AC7 WriteFacMac formWriteFacMac os command injection", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257940" }, { "name": "VDB-257940 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257940" }, { "name": "Submit #300360 | Tenda AC7 V1.0 V15.03.06.44 command injection", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.300360" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWriteFacMac.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257940. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 entdeckt. Es betrifft die Funktion formWriteFacMac der Datei /goform/WriteFacMac. Dank Manipulation des Arguments mac mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.5, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 OS Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-26T18:31:04.287Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257940 | Tenda AC7 WriteFacMac formWriteFacMac os command injection", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257940" }, { "name": "VDB-257940 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257940" }, { "name": "Submit #300360 | Tenda AC7 V1.0 V15.03.06.44 command injection", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.300360" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWriteFacMac.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-26T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-26T10:31:02.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 WriteFacMac formWriteFacMac os command injection" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2897", "datePublished": "2024-03-26T18:31:04.287Z", "dateReserved": "2024-03-26T09:25:55.503Z", "dateUpdated": "2024-08-01T19:25:42.169Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-18730 (GCVE-0-2018-18730)
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'startIp' and 'endIp' parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.429Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18730", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027startIp\u0027 and \u0027endIp\u0027 parameters for a post request, each value is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack3.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18730", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.429Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-37717 (GCVE-0-2023-37717)
Vulnerability from cvelistv5
Published
2023-07-14 00:00
Modified
2024-10-30 15:39
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:23:27.232Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1202", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0BR_V1.2.0.20(408)" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1202", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.2.0.19_EN" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37717", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-30T15:36:28.731124Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-30T15:39:40.848Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-14T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/fromDhcpListClient/repot.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-37717", "datePublished": "2023-07-14T00:00:00", "dateReserved": "2023-07-10T00:00:00", "dateUpdated": "2024-10-30T15:39:40.848Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-41558 (GCVE-0-2023-41558)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 19:34
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:01:35.321Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetSysTime/1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0_v15.03.06.44" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-41558", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-01T19:33:24.853303Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-01T19:34:20.132Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-30T12:21:30.792655", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetSysTime/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-41558", "datePublished": "2023-08-30T00:00:00", "dateReserved": "2023-08-30T00:00:00", "dateUpdated": "2024-10-01T19:34:20.132Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-29137 (GCVE-0-2025-29137)
Vulnerability from cvelistv5
Published
2025-03-19 00:00
Modified
2025-03-19 20:44
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set function, which can cause RCE.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-29137", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-19T20:36:41.623980Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-19T20:44:09.904Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set function, which can cause RCE." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-19T15:27:39.561Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Raining-101/IOT_cve/blob/main/tenda-ac7form_fast_setting_wifi_set%20timeZone.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-29137", "datePublished": "2025-03-19T00:00:00.000Z", "dateReserved": "2025-03-11T00:00:00.000Z", "dateUpdated": "2025-03-19T20:44:09.904Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-48826 (GCVE-0-2024-48826)
Vulnerability from cvelistv5
Published
2024-10-28 00:00
Modified
2024-10-29 18:42
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC7 v.15.03.06.44 ate_iwpriv_set has pre-authentication command injection allowing remote attackers to execute arbitrary code.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-48826", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-29T14:38:16.282384Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-29T18:42:18.709Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 v.15.03.06.44 ate_iwpriv_set has pre-authentication command injection allowing remote attackers to execute arbitrary code." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-28T19:27:53.618429", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/ixout/iotVuls/blob/main/Tenda/ac7_006/report.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-48826", "datePublished": "2024-10-28T00:00:00", "dateReserved": "2024-10-08T00:00:00", "dateUpdated": "2024-10-29T18:42:18.709Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-4809 (GCVE-0-2025-4809)
Vulnerability from cvelistv5
Published
2025-05-16 20:00
Modified
2025-05-17 02:29
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-4809", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-05-17T02:29:39.364436Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-05-17T02:29:55.165Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 ausgemacht. Betroffen hiervon ist die Funktion fromSafeSetMacFilter der Datei /goform/setMacFilterCfg. Durch Beeinflussen des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-05-16T20:00:14.307Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-309264 | Tenda AC7 setMacFilterCfg fromSafeSetMacFilter stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.309264" }, { "name": "VDB-309264 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.309264" }, { "name": "Submit #573642 | Tenda AC7 V1.0 V15.03.06.44 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.573642" }, { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC7-fromSafeSetMacFilter-1ed53a41781f80cbbf13c8d4cc405ed1?pvs=4" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-05-16T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-05-16T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-05-16T10:49:17.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 setMacFilterCfg fromSafeSetMacFilter stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-4809", "datePublished": "2025-05-16T20:00:14.307Z", "dateReserved": "2025-05-16T08:44:09.877Z", "dateUpdated": "2025-05-17T02:29:55.165Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-18732 (GCVE-0-2018-18732)
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'ntpServer' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.422Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18732", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027ntpServer\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack2.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18732", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.422Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-2899 (GCVE-0-2024-2899)
Vulnerability from cvelistv5
Published
2024-03-26 19:00
Modified
2025-04-10 18:28
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2899", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-16T17:43:12.540684Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-04-10T18:28:47.028Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.223Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257942 | Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257942" }, { "name": "VDB-257942 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257942" }, { "name": "Submit #300362 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.300362" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWirelessRepeat.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda AC7 15.03.06.44 entdeckt. Dies betrifft die Funktion fromSetWirelessRepeat der Datei /goform/WifiExtraSet. Durch die Manipulation des Arguments wpapsk_crypto mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-26T19:00:07.170Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257942 | Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257942" }, { "name": "VDB-257942 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257942" }, { "name": "Submit #300362 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.300362" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/fromSetWirelessRepeat.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-26T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-26T10:31:13.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 WifiExtraSet fromSetWirelessRepeat stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2899", "datePublished": "2024-03-26T19:00:07.170Z", "dateReserved": "2024-03-26T09:26:06.184Z", "dateUpdated": "2025-04-10T18:28:47.028Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-9023 (GCVE-0-2025-9023)
Vulnerability from cvelistv5
Published
2025-08-15 08:32
Modified
2025-08-15 16:01
Severity ?
VLAI Severity ?
EPSS score ?
Summary
A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-9023", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-08-15T15:59:19.714899Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-08-15T16:01:28.497Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.19" }, { "status": "affected", "version": "15.03.06.44" } ] }, { "product": "AC18", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.05.19" }, { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "zezhifu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Dabei betrifft es die Funktion formSetSchedLed der Datei /goform/SetLEDCfg. Durch Beeinflussen des Arguments Time mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-08-15T08:32:07.431Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-320088 | Tenda AC7/AC18 SetLEDCfg formSetSchedLed buffer overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.320088" }, { "name": "VDB-320088 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.320088" }, { "name": "Submit #629692 | Tenda AC7 V15.03.06.44 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.629692" }, { "name": "Submit #629696 | Tenda AC18 V15.03.05.19(6318) Buffer Overflow (Duplicate)", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.629696" }, { "tags": [ "related" ], "url": "https://github.com/zezhifu1/cve_report/blob/main/AC7/formsetschedled.md" }, { "tags": [ "exploit" ], "url": "https://github.com/zezhifu1/cve_report/blob/main/AC18/formsetschedled.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-08-14T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-08-14T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-08-14T09:13:33.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7/AC18 SetLEDCfg formSetSchedLed buffer overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-9023", "datePublished": "2025-08-15T08:32:07.431Z", "dateReserved": "2025-08-14T07:07:03.862Z", "dateUpdated": "2025-08-15T16:01:28.497Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-18706 (GCVE-0-2018-18706)
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "page" parameter of the function "fromDhcpListClient" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function.
References
► | URL | Tags |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.389Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-27T22:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18706", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"page\" parameter of the function \"fromDhcpListClient\" for a request, it is directly used in a sprintf to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-06/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18706", "datePublished": "2018-10-27T22:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.389Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-2896 (GCVE-0-2024-2896)
Vulnerability from cvelistv5
Published
2024-03-26 18:00
Modified
2024-08-01 19:25
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2896", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-06-26T19:44:29.669077Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-26T19:49:54.294Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.175Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257939 | Tenda AC7 WifiWpsStart formWifiWpsStart stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257939" }, { "name": "VDB-257939 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257939" }, { "name": "Submit #300359 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.300359" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsStart.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC7 15.03.06.44 ausgemacht. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formWifiWpsStart der Datei /goform/WifiWpsStart. Dank der Manipulation des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-26T18:00:06.676Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257939 | Tenda AC7 WifiWpsStart formWifiWpsStart stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257939" }, { "name": "VDB-257939 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257939" }, { "name": "Submit #300359 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.300359" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formWifiWpsStart.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-26T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-26T10:30:56.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 WifiWpsStart formWifiWpsStart stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2896", "datePublished": "2024-03-26T18:00:06.676Z", "dateReserved": "2024-03-26T09:25:50.265Z", "dateUpdated": "2024-08-01T19:25:42.175Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-41556 (GCVE-0-2023-41556)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 19:40
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:01:35.265Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0_v15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "3.0_v15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0rtl_v15.03.06.28" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-41556", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-01T19:38:05.672947Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-01T19:40:15.233Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-30T12:25:24.881206", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromSetIpMacBind/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-41556", "datePublished": "2023-08-30T00:00:00", "dateReserved": "2023-08-30T00:00:00", "dateUpdated": "2024-10-01T19:40:15.233Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-41552 (GCVE-0-2023-41552)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 19:49
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:01:35.281Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/form_fast_setting_wifi_set/1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0_v15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "3.0_v15.03.06.42_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-41552", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-01T19:48:17.214882Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-01T19:49:40.131Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-30T12:28:31.907320", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/form_fast_setting_wifi_set/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-41552", "datePublished": "2023-08-30T00:00:00", "dateReserved": "2023-08-30T00:00:00", "dateUpdated": "2024-10-01T19:49:40.131Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-18709 (GCVE-0-2018-18709)
Vulnerability from cvelistv5
Published
2018-10-27 22:00
Modified
2024-08-05 11:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router's web server -- httpd. When processing the "firewallEn" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
► | URL | Tags |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.371Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-27T22:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18709", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. It is a buffer overflow vulnerability in the router\u0027s web server -- httpd. When processing the \"firewallEn\" parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-08/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18709", "datePublished": "2018-10-27T22:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.371Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-2900 (GCVE-0-2024-2900)
Vulnerability from cvelistv5
Published
2024-03-26 19:31
Modified
2024-08-01 19:25
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2900", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-01T18:06:26.520903Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-01T18:08:23.914Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.144Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257943 | Tenda AC7 saveParentControlInfo stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257943" }, { "name": "VDB-257943 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257943" }, { "name": "Submit #300364 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.300364" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/saveParentControlInfo_deviceId.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda AC7 15.03.06.44 gefunden. Dabei betrifft es die Funktion saveParentControlInfo der Datei /goform/saveParentControlInfo. Durch Manipulation des Arguments deviceId/time/urls mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-26T19:31:04.524Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257943 | Tenda AC7 saveParentControlInfo stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257943" }, { "name": "VDB-257943 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257943" }, { "name": "Submit #300364 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.300364" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/saveParentControlInfo_deviceId.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-26T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-26T10:31:26.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 saveParentControlInfo stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2900", "datePublished": "2024-03-26T19:31:04.524Z", "dateReserved": "2024-03-26T09:26:11.290Z", "dateUpdated": "2024-08-01T19:25:42.144Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-41555 (GCVE-0-2023-41555)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 19:42
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:01:35.250Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/formWifiBasicSet/1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0_v15.03.06.44" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-41555", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-01T19:41:30.498142Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-01T19:42:23.000Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-30T12:27:06.027581", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/formWifiBasicSet/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-41555", "datePublished": "2023-08-30T00:00:00", "dateReserved": "2023-08-30T00:00:00", "dateUpdated": "2024-10-01T19:42:23.000Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-14557 (GCVE-0-2018-14557)
Vulnerability from cvelistv5
Published
2019-04-25 19:42
Modified
2024-08-05 09:29
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow.
References
► | URL | Tags |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T09:29:51.699Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-04-25T19:42:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-14557", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the page parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, a causing buffer overflow." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-03/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-14557", "datePublished": "2019-04-25T19:42:41", "dateReserved": "2018-07-23T00:00:00", "dateUpdated": "2024-08-05T09:29:51.699Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-38937 (GCVE-0-2023-38937)
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-17 14:40
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.643Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4 V16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4.0 V16.03.10.13" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38937", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-17T14:37:17.298133Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-17T14:40:31.909Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38937", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-17T14:40:31.909Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-3346 (GCVE-0-2025-3346)
Vulnerability from cvelistv5
Published
2025-04-07 09:31
Modified
2025-04-07 16:11
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
Summary
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-3346", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-04-07T16:11:19.829467Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-04-07T16:11:42.026Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "CH13hh (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda AC7 15.03.06.44 ausgemacht. Davon betroffen ist die Funktion formSetPPTPServer der Datei /goform/SetPptpServerCfg. Durch Manipulation des Arguments pptp_server_start_ip/pptp_server_end_ip mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-04-07T09:31:08.740Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-303560 | Tenda AC7 SetPptpServerCfg formSetPPTPServer buffer overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.303560" }, { "name": "VDB-303560 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.303560" }, { "name": "Submit #551927 | Shenzhen Tenda Technology Co.,Ltd. AC7 V15.03.06.44 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.551927" }, { "tags": [ "exploit" ], "url": "https://github.com/CH13hh/tmp_store_cc/blob/main/AC7formSetPPTPServer/formSetPPTPServer.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-04-06T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-04-06T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-04-06T16:43:57.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 SetPptpServerCfg formSetPPTPServer buffer overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-3346", "datePublished": "2025-04-07T09:31:08.740Z", "dateReserved": "2025-04-06T14:38:54.203Z", "dateUpdated": "2025-04-07T16:11:42.026Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-1819 (GCVE-0-2025-1819)
Vulnerability from cvelistv5
Published
2025-03-02 16:31
Modified
2025-03-03 20:10
Severity ?
5.3 (Medium) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
VLAI Severity ?
EPSS score ?
Summary
A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-1819", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-03T17:15:11.891552Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-03T20:10:12.362Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC7 1200M", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "Raining101 (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda AC7 1200M 15.03.06.44 gefunden. Sie wurde als kritisch eingestuft. Es geht dabei um die Funktion TendaTelnet der Datei /goform/telnet. Durch die Manipulation des Arguments lan_ip mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.5, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "OS Command Injection", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-77", "description": "Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-02T16:31:05.928Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-298092 | Tenda AC7 1200M telnet TendaTelnet os command injection", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.298092" }, { "name": "VDB-298092 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.298092" }, { "name": "Submit #504429 | Tenda AC7 1200M large household 11ac dual-band wireless router V15.03.06.44 Command injection", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.504429" }, { "tags": [ "exploit" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/Tenda%20a7%20V15.03.06.44%20Command%20injection.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-03-01T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-03-01T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-03-01T15:37:10.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 1200M telnet TendaTelnet os command injection" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-1819", "datePublished": "2025-03-02T16:31:05.928Z", "dateReserved": "2025-03-01T14:32:01.743Z", "dateUpdated": "2025-03-03T20:10:12.362Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-41562 (GCVE-0-2023-41562)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 18:55
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:01:35.185Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0_v15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "3.0_v15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0rtl_v15.03.06.28" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-41562", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-01T18:52:45.696202Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-01T18:55:00.806Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-30T12:17:16.245089", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-41562", "datePublished": "2023-08-30T00:00:00", "dateReserved": "2023-08-30T00:00:00", "dateUpdated": "2024-10-01T18:55:00.806Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-38931 (GCVE-0-2023-38931)
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-17 13:55
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.242Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4 V16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4.0 V16.03.10.13" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38931", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-17T13:52:20.173225Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-17T13:55:25.786Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38931", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-17T13:55:25.786Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-18727 (GCVE-0-2018-18727)
Vulnerability from cvelistv5
Published
2018-10-28 00:00
Modified
2024-08-05 11:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server -- httpd. While processing the 'deviceList' parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:16:00.390Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-10-27T00:00:00", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-28T00:57:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-18727", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router\u0027s web server -- httpd. While processing the \u0027deviceList\u0027 parameter for a post request, the value is directly used in a strcpy to a local variable placed on the stack, which overrides the return address of the function." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md", "refsource": "MISC", "url": "https://github.com/ZIllR0/Routers/blob/master/Tenda/stack1.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-18727", "datePublished": "2018-10-28T00:00:00", "dateReserved": "2018-10-27T00:00:00", "dateUpdated": "2024-08-05T11:16:00.390Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-14558 (GCVE-0-2018-14558)
Vulnerability from cvelistv5
Published
2018-10-30 18:00
Modified
2025-07-30 01:46
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
References
► | URL | Tags |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T09:29:51.678Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2018-14558", "options": [ { "Exploitation": "active" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-04T20:44:12.590931Z", "version": "2.0.3" }, "type": "ssvc" } }, { "other": { "content": { "dateAdded": "2021-11-03", "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2018-14558" }, "type": "kev" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-30T01:46:12.082Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "timeline": [ { "lang": "en", "time": "2021-11-03T00:00:00+00:00", "value": "CVE-2018-14558 added to CISA KEV" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2018-07-21T00:00:00.000Z", "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-10-30T17:57:01.000Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-14558", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the \"formsetUsbUnload\" function executes a dosystemCmd function with untrusted input." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-14558", "datePublished": "2018-10-30T18:00:00.000Z", "dateReserved": "2018-07-23T00:00:00.000Z", "dateUpdated": "2025-07-30T01:46:12.082Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-38933 (GCVE-0-2023-38933)
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-17 13:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.649Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1205", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.0.7(775)" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38933", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-17T13:48:33.206945Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-17T13:51:46.931Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38933", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-17T13:51:46.931Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2018-14559 (GCVE-0-2018-14559)
Vulnerability from cvelistv5
Published
2019-04-25 19:44
Modified
2024-08-05 09:29
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router's web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow.
References
► | URL | Tags |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T09:29:51.666Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-04-25T19:44:46", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2018-14559", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A buffer overflow vulnerability exists in the router\u0027s web server (httpd). When processing the list parameters for a post request, the value is directly written with sprintf to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md", "refsource": "MISC", "url": "https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-02/Tenda.md" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2018-14559", "datePublished": "2019-04-25T19:44:46", "dateReserved": "2018-07-23T00:00:00", "dateUpdated": "2024-08-05T09:29:51.666Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-41559 (GCVE-0-2023-41559)
Vulnerability from cvelistv5
Published
2023-08-30 00:00
Modified
2024-10-01 19:28
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:01:35.261Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0_v15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "3.0_v15.03.06.42_multi," } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0rtl_v15.03.06.28" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-41559", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-01T19:26:04.363328Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-01T19:28:01.330Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-30T12:19:49.860110", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/peris-navince/founded-0-days/blob/main/fromNatStaticSetting/1.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-41559", "datePublished": "2023-08-30T00:00:00", "dateReserved": "2023-08-30T00:00:00", "dateUpdated": "2024-10-01T19:28:01.330Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-48825 (GCVE-0-2024-48825)
Vulnerability from cvelistv5
Published
2024-10-28 00:00
Modified
2024-10-29 18:43
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC7 v.15.03.06.44 ate_ifconfig_set has pre-authentication command injection allowing remote attackers to execute arbitrary code.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-48825", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-29T14:38:33.628036Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-29T18:43:24.763Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC7 v.15.03.06.44 ate_ifconfig_set has pre-authentication command injection allowing remote attackers to execute arbitrary code." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-28T19:24:54.714272", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/ixout/iotVuls/blob/main/Tenda/ac7_005/report.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-48825", "datePublished": "2024-10-28T00:00:00", "dateReserved": "2024-10-08T00:00:00", "dateUpdated": "2024-10-29T18:43:24.763Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-2892 (GCVE-0-2024-2892)
Vulnerability from cvelistv5
Published
2024-03-26 16:00
Modified
2024-08-29 19:09
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T19:25:42.154Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-257935 | Tenda AC7 setcfm formSetCfm stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.257935" }, { "name": "VDB-257935 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.257935" }, { "name": "Submit #300355 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.300355" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetCfm.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-2892", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-20T20:56:27.735043Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-29T19:09:59.106Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC7 15.03.06.44 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Es geht um die Funktion formSetCfm der Datei /goform/setcfm. Durch das Manipulieren des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-26T16:00:05.583Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-257935 | Tenda AC7 setcfm formSetCfm stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.257935" }, { "name": "VDB-257935 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.257935" }, { "name": "Submit #300355 | Tenda AC7 V1.0 V15.03.06.44 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.300355" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC7/v1/formSetCfm.md" } ], "timeline": [ { "lang": "en", "time": "2024-03-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-03-26T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-03-26T10:30:35.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC7 setcfm formSetCfm stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-2892", "datePublished": "2024-03-26T16:00:05.583Z", "dateReserved": "2024-03-26T09:25:27.601Z", "dateUpdated": "2024-08-29T19:09:59.106Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }