Vulnerabilites related to tenda - ac8
CVE-2024-10280 (GCVE-0-2024-10280)
Vulnerability from cvelistv5
Published
2024-10-23 13:31
Modified
2024-10-23 17:41
Severity ?
7.1 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-476 - NULL Pointer Dereference
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.09" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.48.23" }, { "status": "affected", "version": "16.03.48.19" }, { "status": "affected", "version": "16.03.48.20" }, { "status": "affected", "version": "16.03.48.13" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac9_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.42" }, { "status": "affected", "version": "15.03.05.19\\(6318_\\)" }, { "status": "affected", "version": "15.03.05.14" }, { "status": "affected", "version": "15.03.2.13" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac18_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.05" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac18_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.19\\(6318\\)" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "2.0.1.9\\(1307\\)" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.16" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac500_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10u_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.48" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10u_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.49" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.18" } ] }, { "cpes": [ "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac15_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "15.03.05.19" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-10280", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-10-23T17:28:19.760214Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-23T17:41:57.370Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC6", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC7", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC9", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC10", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC10U", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC15", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC18", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC500", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] }, { "product": "AC1206", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "20241022" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "minipython (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 bis 20241022 ausgemacht. Sie wurde als problematisch eingestuft. Davon betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.8, "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-23T13:31:07.315Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-281555 | Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.281555" }, { "name": "VDB-281555 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.281555" }, { "name": "Submit #426417 | Tenda AC8v4 V16.03.34.06 NULL Pointer Dereference", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.426417" }, { "tags": [ "exploit" ], "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2024-10-23T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-10-23T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-10-23T08:07:55.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC6/AC7/AC8/AC9/AC10/AC10U/AC15/AC18/AC500/AC1206 GetIPTV websReadEvent null pointer dereference" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-10280", "datePublished": "2024-10-23T13:31:07.315Z", "dateReserved": "2024-10-23T06:02:03.363Z", "dateUpdated": "2024-10-23T17:41:57.370Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-25663 (GCVE-0-2025-25663)
Vulnerability from cvelistv5
Published
2025-02-20 00:00
Modified
2025-02-21 17:27
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
A vulnerability was found in Tenda AC8V4 V16.03.34.06. Affected is the function SUB_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-25663", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-21T17:26:23.767985Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-21T17:27:05.154Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8V4 V16.03.34.06. Affected is the function SUB_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-20T22:32:43.153Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/jangfan/my-vuln/blob/main/Tenda/AC8V4/WifiExtraSet.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-25663", "datePublished": "2025-02-20T00:00:00.000Z", "dateReserved": "2025-02-07T00:00:00.000Z", "dateUpdated": "2025-02-21T17:27:05.154Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-25667 (GCVE-0-2025-25667)
Vulnerability from cvelistv5
Published
2025-02-20 00:00
Modified
2025-02-21 17:22
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-25667", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-21T17:21:48.242898Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-21T17:22:18.470Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-20T22:31:13.839Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/jangfan/my-vuln/blob/main/Tenda/AC8V4/saveParentControlInfo.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-25667", "datePublished": "2025-02-20T00:00:00.000Z", "dateReserved": "2025-02-07T00:00:00.000Z", "dateUpdated": "2025-02-21T17:22:18.470Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-11745 (GCVE-0-2024-11745)
Vulnerability from cvelistv5
Published
2024-11-26 21:00
Modified
2024-11-26 21:20
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
Summary
A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.09" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-11745", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-26T21:18:06.466624Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-26T21:20:43.347Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.34.09" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "hand_king (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC8 16.03.34.09 gefunden. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion route_static_check der Datei /goform/SetStaticRouteCfg. Durch Beeinflussen des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-26T21:00:12.592Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-286142 | Tenda AC8 SetStaticRouteCfg route_static_check stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.286142" }, { "name": "VDB-286142 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.286142" }, { "name": "Submit #449893 | Tenda AC8v4 V16.03.34.09 Stack-based Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.449893" }, { "tags": [ "exploit" ], "url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC8v4-route_static_check-stack-overflow-1460448e6195803087a5d39755d2bb6b?pvs=74" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2024-11-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-11-26T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-11-26T14:41:47.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC8 SetStaticRouteCfg route_static_check stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-11745", "datePublished": "2024-11-26T21:00:12.592Z", "dateReserved": "2024-11-26T13:36:43.822Z", "dateUpdated": "2024-11-26T21:20:43.347Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-33672 (GCVE-0-2023-33672)
Vulnerability from cvelistv5
Published
2023-06-02 00:00
Modified
2025-01-08 20:20
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T15:47:06.687Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N2/README.md" }, { "tags": [ "x_transferred" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N2" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-33672", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-08T20:20:09.780196Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-08T20:20:27.152Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-12T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N2/README.md" }, { "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N2" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-33672", "datePublished": "2023-06-02T00:00:00", "dateReserved": "2023-05-22T00:00:00", "dateUpdated": "2025-01-08T20:20:27.152Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-25668 (GCVE-0-2025-25668)
Vulnerability from cvelistv5
Published
2025-02-20 00:00
Modified
2025-02-21 17:20
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_47D878 function.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-25668", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-21T17:20:12.374501Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-21T17:20:48.279Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_47D878 function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-20T22:29:47.052Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/jangfan/my-vuln/blob/main/Tenda/AC8V4/setMacFilterCfg.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-25668", "datePublished": "2025-02-20T00:00:00.000Z", "dateReserved": "2025-02-07T00:00:00.000Z", "dateUpdated": "2025-02-21T17:20:48.279Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-4066 (GCVE-0-2024-4066)
Vulnerability from cvelistv5
Published
2024-04-23 21:00
Modified
2024-08-01 20:26
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.06" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-4066", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-24T13:09:02.772550Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:55:37.046Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:26:57.266Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-261792 | Tenda AC8 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.261792" }, { "name": "VDB-261792 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.261792" }, { "name": "Submit #316495 | Tenda AC8v4 V16.03.34.09 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.316495" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/fromAdvSetMacMtuWan.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.34.09" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda AC8 16.03.34.09 entdeckt. Es geht dabei um die Funktion fromAdvSetMacMtuWan der Datei /goform/AdvSetMacMtuWan. Durch die Manipulation des Arguments wanMTU/wanSpeed/cloneType/mac/serviceName/serverName mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-23T21:00:08.132Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-261792 | Tenda AC8 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.261792" }, { "name": "VDB-261792 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.261792" }, { "name": "Submit #316495 | Tenda AC8v4 V16.03.34.09 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.316495" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/fromAdvSetMacMtuWan.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-23T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-23T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-23T15:27:32.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC8 AdvSetMacMtuWan fromAdvSetMacMtuWan stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4066", "datePublished": "2024-04-23T21:00:08.132Z", "dateReserved": "2024-04-23T13:22:24.724Z", "dateUpdated": "2024-08-01T20:26:57.266Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-4065 (GCVE-0-2024-4065)
Vulnerability from cvelistv5
Published
2024-04-23 20:00
Modified
2024-08-01 20:26
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8", "vendor": "tenda", "versions": [ { "status": "affected", "version": "-" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-4065", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-24T14:33:54.863413Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:53:56.992Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:26:57.322Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-261791 | Tenda AC8 SetRebootTimer formSetRebootTimer stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.261791" }, { "name": "VDB-261791 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.261791" }, { "name": "Submit #316494 | Tenda AC8v4 V16.03.34.09 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.316494" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/formSetRebootTimer.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.34.09" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda AC8 16.03.34.09 ausgemacht. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion formSetRebootTimer der Datei /goform/SetRebootTimer. Mit der Manipulation des Arguments rebootTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-23T20:00:07.093Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-261791 | Tenda AC8 SetRebootTimer formSetRebootTimer stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.261791" }, { "name": "VDB-261791 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.261791" }, { "name": "Submit #316494 | Tenda AC8v4 V16.03.34.09 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.316494" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/formSetRebootTimer.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-23T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-23T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-23T15:27:31.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC8 SetRebootTimer formSetRebootTimer stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4065", "datePublished": "2024-04-23T20:00:07.093Z", "dateReserved": "2024-04-23T13:22:21.928Z", "dateUpdated": "2024-08-01T20:26:57.322Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-33671 (GCVE-0-2023-33671)
Vulnerability from cvelistv5
Published
2023-06-02 00:00
Modified
2025-01-08 20:24
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T15:47:06.576Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N4/README.md" }, { "tags": [ "x_transferred" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N4" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-33671", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-08T20:24:35.883610Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-08T20:24:40.493Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-12T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N4/README.md" }, { "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N4" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-33671", "datePublished": "2023-06-02T00:00:00", "dateReserved": "2023-05-22T00:00:00", "dateUpdated": "2025-01-08T20:24:40.493Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5799 (GCVE-0-2025-5799)
Vulnerability from cvelistv5
Published
2025-06-06 19:31
Modified
2025-06-09 15:09
Severity ?
VLAI Severity ?
EPSS score ?
Summary
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5799", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-06-09T15:09:19.735542Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-09T15:09:23.510Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC8-fromSetWirelessRepeat-20a53a41781f803d9156f0babaf94fca" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.34.09" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_ (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "In Tenda AC8 16.03.34.09 wurde eine kritische Schwachstelle ausgemacht. Dabei geht es um die Funktion fromSetWirelessRepeat der Datei /goform/WifiExtraSet. Durch das Beeinflussen des Arguments wpapsk_crypto mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-06T19:31:11.477Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-311353 | Tenda AC8 WifiExtraSet fromSetWirelessRepeat stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.311353" }, { "name": "VDB-311353 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.311353" }, { "name": "Submit #591270 | Tenda AC8 v4 V16.03.34.09 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.591270" }, { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC8-fromSetWirelessRepeat-20a53a41781f803d9156f0babaf94fca?source=copy_link" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-06-06T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-06-06T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-06-06T10:39:50.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC8 WifiExtraSet fromSetWirelessRepeat stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-5799", "datePublished": "2025-06-06T19:31:11.477Z", "dateReserved": "2025-06-06T08:34:44.744Z", "dateUpdated": "2025-06-09T15:09:23.510Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-51087 (GCVE-0-2025-51087)
Vulnerability from cvelistv5
Published
2025-07-24 00:00
Modified
2025-07-24 14:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-51087", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-07-24T14:58:36.245472Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-24T14:59:27.449Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-24T14:41:44.415Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "http://tenda.com" }, { "url": "https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51087.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-51087", "datePublished": "2025-07-24T00:00:00.000Z", "dateReserved": "2025-06-16T00:00:00.000Z", "dateUpdated": "2025-07-24T14:59:27.449Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-33675 (GCVE-0-2023-33675)
Vulnerability from cvelistv5
Published
2023-06-02 00:00
Modified
2025-01-08 20:16
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T15:47:06.738Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N5/README.md" }, { "tags": [ "x_transferred" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N5" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-33675", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-08T20:16:14.903911Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-08T20:16:20.812Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-12T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N5/README.md" }, { "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N5" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-33675", "datePublished": "2023-06-02T00:00:00", "dateReserved": "2023-05-22T00:00:00", "dateUpdated": "2025-01-08T20:16:20.812Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-29100 (GCVE-0-2025-29100)
Vulnerability from cvelistv5
Published
2025-03-24 00:00
Modified
2025-03-26 14:36
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the parameter list.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-29100", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-26T14:35:42.750991Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-26T14:36:13.282Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/Tenda%20a8%20V16.03.34.06%20fromSetRouteStatic_stack_overflow.md" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the parameter list." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-24T20:40:39.969Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Raining-101/IOT_cve/blob/main/Tenda%20a8%20V16.03.34.06%20fromSetRouteStatic_stack_overflow.md" }, { "url": "https://gist.github.com/Raining-101/b2bd27d16cdca94d330150a8ead9caa8" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-29100", "datePublished": "2025-03-24T00:00:00.000Z", "dateReserved": "2025-03-11T00:00:00.000Z", "dateUpdated": "2025-03-26T14:36:13.282Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-29101 (GCVE-0-2025-29101)
Vulnerability from cvelistv5
Published
2025-03-20 00:00
Modified
2025-03-24 13:21
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4.0 V16.03.34.06 was discovered to contain a stack overflow via the deviceid parameter in the get_parentControl_list_Info function.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-29101", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-24T13:20:39.043980Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-24T13:21:10.892Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/tenda-ac8_get_parentControl_list_Info_overflow.md" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4.0 V16.03.34.06 was discovered to contain a stack overflow via the deviceid parameter in the get_parentControl_list_Info function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-20T12:46:41.970Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Raining-101/IOT_cve/blob/main/tenda-ac8_get_parentControl_list_Info_overflow.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-29101", "datePublished": "2025-03-20T00:00:00.000Z", "dateReserved": "2025-03-11T00:00:00.000Z", "dateUpdated": "2025-03-24T13:21:10.892Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-38935 (GCVE-0-2023-38935)
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-15 20:07
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.522Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V4 V16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4.0 V16.03.10.13" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38935", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-15T20:06:05.688360Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-15T20:07:56.040Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38935", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-15T20:07:56.040Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-57703 (GCVE-0-2024-57703)
Vulnerability from cvelistv5
Published
2025-01-16 00:00
Modified
2025-02-04 14:46
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-57703", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-04T14:45:58.609932Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-04T14:46:07.370Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-16T22:10:21.679Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Pr0b1em/IoT/blob/master/Tenda%20AC8v4%20V16.03.34.06.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-57703", "datePublished": "2025-01-16T00:00:00.000Z", "dateReserved": "2025-01-09T00:00:00.000Z", "dateUpdated": "2025-02-04T14:46:07.370Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-25664 (GCVE-0-2025-25664)
Vulnerability from cvelistv5
Published
2025-02-20 00:00
Modified
2025-02-21 17:24
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 function.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-25664", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-02-21T17:24:04.639558Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-21T17:24:32.545Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-20T22:28:25.102Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/jangfan/my-vuln/blob/main/Tenda/AC8V4/SetIpMacBind.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-25664", "datePublished": "2025-02-20T00:00:00.000Z", "dateReserved": "2025-02-07T00:00:00.000Z", "dateUpdated": "2025-02-21T17:24:32.545Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-25510 (GCVE-0-2025-25510)
Vulnerability from cvelistv5
Published
2025-02-21 00:00
Modified
2025-02-21 20:48
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the get_parentControl_list_Info function.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-25510", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-02-21T20:47:18.395940Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-21T20:48:05.771Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the get_parentControl_list_Info function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-21T17:03:09.315Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/faqiadegege/IoTVuln/blob/main/tendaAC8_get_parentControl_list_Info_urls_overflow/detail.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-25510", "datePublished": "2025-02-21T00:00:00.000Z", "dateReserved": "2025-02-07T00:00:00.000Z", "dateUpdated": "2025-02-21T20:48:05.771Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-4368 (GCVE-0-2025-4368)
Vulnerability from cvelistv5
Published
2025-05-06 15:31
Modified
2025-05-06 15:43
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
Summary
A vulnerability, which was classified as critical, was found in Tenda AC8 16.03.34.06. Affected is the function formGetRouterStatus of the file /goform/MtuSetMacWan. The manipulation of the argument shareSpeed leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-4368", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-05-06T15:43:00.578584Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-05-06T15:43:26.512Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.34.06" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "fjl1113 (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC8 16.03.34.06. Affected is the function formGetRouterStatus of the file /goform/MtuSetMacWan. The manipulation of the argument shareSpeed leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda AC8 16.03.34.06 gefunden. Sie wurde als kritisch eingestuft. Dabei betrifft es die Funktion formGetRouterStatus der Datei /goform/MtuSetMacWan. Mittels dem Manipulieren des Arguments shareSpeed mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-05-06T15:31:08.687Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-307488 | Tenda AC8 MtuSetMacWan formGetRouterStatus buffer overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.307488" }, { "name": "VDB-307488 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.307488" }, { "name": "Submit #564812 | Tenda Router AC8 V16.03.34.06 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.564812" }, { "tags": [ "broken-link", "exploit" ], "url": "https://github.com/fjl1113/cve/blob/main/Tenda.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-05-05T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-05-05T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-05-05T21:11:49.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC8 MtuSetMacWan formGetRouterStatus buffer overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-4368", "datePublished": "2025-05-06T15:31:08.687Z", "dateReserved": "2025-05-05T19:06:35.443Z", "dateUpdated": "2025-05-06T15:43:26.512Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-33669 (GCVE-0-2023-33669)
Vulnerability from cvelistv5
Published
2023-06-02 00:00
Modified
2025-01-08 20:27
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub_44db3c function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T15:47:06.525Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N1/README.md" }, { "tags": [ "x_transferred" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N1" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-33669", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-08T20:27:39.263347Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-08T20:27:53.950Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub_44db3c function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-12T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N1/README.md" }, { "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N1" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-33669", "datePublished": "2023-06-02T00:00:00", "dateReserved": "2023-05-22T00:00:00", "dateUpdated": "2025-01-08T20:27:53.950Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-10130 (GCVE-0-2024-10130)
Vulnerability from cvelistv5
Published
2024-10-18 21:31
Modified
2024-10-21 17:50
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.06" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-10130", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-21T17:49:08.621948Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-21T17:50:18.674Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.34.06" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "minipython (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC8 16.03.34.06 wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion formSetRebootTimer der Datei /goform/SetSysAutoRebbotCfg. Dank der Manipulation des Arguments rebootTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-18T21:31:06.724Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-280918 | Tenda AC8 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.280918" }, { "name": "VDB-280918 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.280918" }, { "name": "Submit #422141 | Tenda AC8v4 V16.03.34.06 Stack-based Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.422141" }, { "tags": [ "exploit" ], "url": "https://github.com/JohenanLi/router_vuls/blob/main/ac8v4/FUN_004a8838.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2024-10-18T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-10-18T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-10-18T15:59:18.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC8 SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-10130", "datePublished": "2024-10-18T21:31:06.724Z", "dateReserved": "2024-10-18T13:54:15.157Z", "dateUpdated": "2024-10-21T17:50:18.674Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-38931 (GCVE-0-2023-38931)
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-17 13:55
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.242Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4 V16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "f1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4.0 V16.03.10.13" } ] }, { "cpes": [ "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "fh1203", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0.1.6" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38931", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-17T13:52:20.173225Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-17T13:55:25.786Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38931", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-17T13:55:25.786Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-51082 (GCVE-0-2025-51082)
Vulnerability from cvelistv5
Published
2025-07-24 00:00
Modified
2025-07-24 19:43
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/fast_setting_wifi_set. The manipulation of the argument `timeZone` leads to stack-based buffer overflow.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-51082", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-07-24T19:42:31.117294Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-24T19:43:06.169Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/fast_setting_wifi_set. The manipulation of the argument `timeZone` leads to stack-based buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-24T14:32:17.164Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "http://tenda.com" }, { "url": "https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51082.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-51082", "datePublished": "2025-07-24T00:00:00.000Z", "dateReserved": "2025-06-16T00:00:00.000Z", "dateUpdated": "2025-07-24T19:43:06.169Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-5798 (GCVE-0-2025-5798)
Vulnerability from cvelistv5
Published
2025-06-06 19:31
Modified
2025-06-09 15:10
Severity ?
VLAI Severity ?
EPSS score ?
Summary
A vulnerability was found in Tenda AC8 16.03.34.09. It has been classified as critical. Affected is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeType leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-5798", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-06-09T15:09:49.411038Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-06-09T15:10:10.112Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC8-fromSetSysTime-20a53a41781f807b9489fff42f262e11" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.34.09" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_ (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.09. It has been classified as critical. Affected is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeType leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda AC8 16.03.34.09 ausgemacht. Es geht dabei um die Funktion fromSetSysTime der Datei /goform/SetSysTimeCfg. Durch Manipulieren des Arguments timeType mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-06-06T19:31:07.341Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-311352 | Tenda AC8 SetSysTimeCfg fromSetSysTime stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.311352" }, { "name": "VDB-311352 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.311352" }, { "name": "Submit #591266 | Tenda AC8 v4 V16.03.34.09 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.591266" }, { "tags": [ "exploit" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC8-fromSetSysTime-20a53a41781f807b9489fff42f262e11?source=copy_link" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-06-06T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-06-06T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-06-06T10:39:49.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC8 SetSysTimeCfg fromSetSysTime stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-5798", "datePublished": "2025-06-06T19:31:07.341Z", "dateReserved": "2025-06-06T08:34:40.830Z", "dateUpdated": "2025-06-09T15:10:10.112Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-4744 (GCVE-0-2023-4744)
Vulnerability from cvelistv5
Published
2023-09-03 23:31
Modified
2024-09-30 20:37
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T07:37:59.530Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.238633" }, { "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.238633" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/GleamingEyes/vul/blob/main/tenda_ac8/ac8_1.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.06_cn_tdc01" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-4744", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-09-30T20:35:56.096228Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-30T20:37:02.940Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.34.06_cn_TDC01" } ] } ], "credits": [ { "lang": "en", "type": "analyst", "value": "tianwenqi (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability." }, { "lang": "de", "value": "In Tenda AC8 16.03.34.06_cn_TDC01 wurde eine kritische Schwachstelle ausgemacht. Dabei geht es um die Funktion formSetDeviceName. Durch Beeinflussen mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 10, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-24T15:19:25.174Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.238633" }, { "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.238633" }, { "tags": [ "exploit" ], "url": "https://github.com/GleamingEyes/vul/blob/main/tenda_ac8/ac8_1.md" } ], "timeline": [ { "lang": "en", "time": "2023-09-03T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2023-09-03T00:00:00.000Z", "value": "CVE reserved" }, { "lang": "en", "time": "2023-09-03T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2023-09-29T20:07:59.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC8 formSetDeviceName stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2023-4744", "datePublished": "2023-09-03T23:31:04.502Z", "dateReserved": "2023-09-03T06:37:57.663Z", "dateUpdated": "2024-09-30T20:37:02.940Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-46652 (GCVE-0-2024-46652)
Vulnerability from cvelistv5
Published
2024-09-20 00:00
Modified
2024-09-23 14:27
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability in the fromAdvSetMacMtuWan function.
References
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac8v4_firmware:16.03.34.06:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8v4_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.06" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-46652", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-09-23T14:25:14.505298Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-120", "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-23T14:27:17.925Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability in the fromAdvSetMacMtuWan function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-20T15:33:28.968877", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/zp9080/Tenda/blob/main/Tenda-AC8v4%20V16.03.34.06-fromAdvSetMacMtuWan/overview.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-46652", "datePublished": "2024-09-20T00:00:00", "dateReserved": "2024-09-11T00:00:00", "dateUpdated": "2024-09-23T14:27:17.925Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-33673 (GCVE-0-2023-33673)
Vulnerability from cvelistv5
Published
2023-06-02 00:00
Modified
2025-01-08 20:18
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T15:47:06.759Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N6/README.md" }, { "tags": [ "x_transferred" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N6" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-33673", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-08T20:17:56.083854Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-08T20:18:01.131Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-12T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N6/README.md" }, { "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N6" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-33673", "datePublished": "2023-06-02T00:00:00", "dateReserved": "2023-05-22T00:00:00", "dateUpdated": "2025-01-08T20:18:01.131Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-29118 (GCVE-0-2025-29118)
Vulnerability from cvelistv5
Published
2025-03-19 00:00
Modified
2025-03-21 13:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8 V16.03.34.06 was discovered to contain a stack overflow via the src parameter in the function sub_47D878.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-29118", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-21T13:29:40.413124Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-21T13:30:00.600Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8 V16.03.34.06 was discovered to contain a stack overflow via the src parameter in the function sub_47D878." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-19T16:17:00.896Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Raining-101/IOT_cve/blob/main/tenda-ac8_sub_47D878.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-29118", "datePublished": "2025-03-19T00:00:00.000Z", "dateReserved": "2025-03-11T00:00:00.000Z", "dateUpdated": "2025-03-21T13:30:00.600Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-33670 (GCVE-0-2023-33670)
Vulnerability from cvelistv5
Published
2023-06-02 00:00
Modified
2025-01-08 20:26
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T15:47:06.491Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N3/README.md" }, { "tags": [ "x_transferred" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N3" } ], "title": "CVE Program Container" }, { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2023-33670", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-08T20:26:36.535933Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-08T20:26:40.888Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-12T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N3/README.md" }, { "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N3" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-33670", "datePublished": "2023-06-02T00:00:00", "dateReserved": "2023-05-22T00:00:00", "dateUpdated": "2025-01-08T20:26:40.888Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-51088 (GCVE-0-2025-51088)
Vulnerability from cvelistv5
Published
2025-07-24 00:00
Modified
2025-07-24 19:45
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/WifiGuestSet. The manipulation of the argument `shareSpeed` leads to stack-based buffer overflow.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-51088", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-07-24T19:44:54.140938Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-24T19:45:16.091Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/WifiGuestSet. The manipulation of the argument `shareSpeed` leads to stack-based buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-24T14:55:59.073Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "http://tenda.com" }, { "url": "https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51088.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-51088", "datePublished": "2025-07-24T00:00:00.000Z", "dateReserved": "2025-06-16T00:00:00.000Z", "dateUpdated": "2025-07-24T19:45:16.091Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-1853 (GCVE-0-2025-1853)
Vulnerability from cvelistv5
Published
2025-03-03 06:00
Modified
2025-03-12 21:12
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
Summary
A vulnerability was found in Tenda AC8 16.03.34.06 and classified as critical. This issue affects the function sub_49E098 of the file /goform/SetIpMacBind of the component Parameter Handler. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-1853", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-03-03T13:25:29.288026Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-12T21:12:21.882Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "modules": [ "Parameter Handler" ], "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.34.06" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "Raining101 (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.06 and classified as critical. This issue affects the function sub_49E098 of the file /goform/SetIpMacBind of the component Parameter Handler. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda AC8 16.03.34.06 gefunden. Es geht hierbei um die Funktion sub_49E098 der Datei /goform/SetIpMacBind der Komponente Parameter Handler. Durch Beeinflussen des Arguments list mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-119", "description": "Memory Corruption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-03-03T06:00:08.840Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-298121 | Tenda AC8 Parameter SetIpMacBind sub_49E098 stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.298121" }, { "name": "VDB-298121 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.298121" }, { "name": "Submit #505374 | Tenda ac8 V16.03.34.06 Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.505374" }, { "tags": [ "exploit" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/tenda-ac8_sub_49E098.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-03-02T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-03-02T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-03-02T21:15:43.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC8 Parameter SetIpMacBind sub_49E098 stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-1853", "datePublished": "2025-03-03T06:00:08.840Z", "dateReserved": "2025-03-02T20:10:34.302Z", "dateUpdated": "2025-03-12T21:12:21.882Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-57704 (GCVE-0-2024-57704)
Vulnerability from cvelistv5
Published
2025-01-16 00:00
Modified
2025-02-03 20:34
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2024-57704", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-01-17T16:25:27.701516Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-02-03T20:34:12.035Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-16T22:12:12.312Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Pr0b1em/IoT/blob/master/Tenda%20AC8v4%20V16.03.34.06.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2024-57704", "datePublished": "2025-01-16T00:00:00.000Z", "dateReserved": "2025-01-09T00:00:00.000Z", "dateUpdated": "2025-02-03T20:34:12.035Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-51089 (GCVE-0-2025-51089)
Vulnerability from cvelistv5
Published
2025-07-24 00:00
Modified
2025-07-24 19:46
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4 V16.03.34.06` was discovered to contain heap overflow at /goform/GetParentControlInfo.The manipulation of the argument `mac` leads to heap-based buffer overflow.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-51089", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-07-24T19:46:07.805642Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-122", "description": "CWE-122 Heap-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-24T19:46:41.064Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06` was discovered to contain heap overflow at /goform/GetParentControlInfo.The manipulation of the argument `mac` leads to heap-based buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-24T14:58:48.675Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "http://tenda.com" }, { "url": "https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51089.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-51089", "datePublished": "2025-07-24T00:00:00.000Z", "dateReserved": "2025-06-16T00:00:00.000Z", "dateUpdated": "2025-07-24T19:46:41.064Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-51085 (GCVE-0-2025-51085)
Vulnerability from cvelistv5
Published
2025-07-24 00:00
Modified
2025-07-24 19:43
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/SetSysTimeCfg. The manipulation of the argument `timeZone` and `timeType` leads to stack-based buffer overflow.
References
{ "containers": { "adp": [ { "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, { "other": { "content": { "id": "CVE-2025-51085", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-07-24T19:43:27.165337Z", "version": "2.0.3" }, "type": "ssvc" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-24T19:43:55.648Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/SetSysTimeCfg. The manipulation of the argument `timeZone` and `timeType` leads to stack-based buffer overflow." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2025-07-24T14:33:42.955Z", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "http://tenda.com" }, { "url": "https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51085.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2025-51085", "datePublished": "2025-07-24T00:00:00.000Z", "dateReserved": "2025-06-16T00:00:00.000Z", "dateUpdated": "2025-07-24T19:43:55.648Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-10123 (GCVE-0-2024-10123)
Vulnerability from cvelistv5
Published
2024-10-18 19:31
Modified
2024-10-18 20:42
Severity ?
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compare_parentcontrol_time of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This is not the same issue like CVE-2023-33671. The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.06" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-10123", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-18T20:42:10.984477Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-18T20:42:45.158Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.34.06" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "minipython (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compare_parentcontrol_time of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This is not the same issue like CVE-2023-33671. The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC8 16.03.34.06 wurde eine kritische Schwachstelle ausgemacht. Es geht um die Funktion compare_parentcontrol_time der Datei /goform/saveParentControlInfo. Durch Manipulieren des Arguments time mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-18T19:31:05.643Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-280915 | Tenda AC8 saveParentControlInfo compare_parentcontrol_time stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.280915" }, { "name": "VDB-280915 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.280915" }, { "name": "Submit #421340 | Tenda AC8v4 V16.03.34.06 Stack-based Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.421340" }, { "tags": [ "exploit" ], "url": "https://github.com/JohenanLi/router_vuls/blob/main/ac8v4/compare_parentcontrol_time_vul.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2024-10-18T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-10-18T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-10-18T14:19:53.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC8 saveParentControlInfo compare_parentcontrol_time stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-10123", "datePublished": "2024-10-18T19:31:05.643Z", "dateReserved": "2024-10-18T12:13:59.942Z", "dateUpdated": "2024-10-18T20:42:45.158Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2025-0528 (GCVE-0-2025-0528)
Vulnerability from cvelistv5
Published
2025-01-17 14:31
Modified
2025-01-17 14:48
Severity ?
8.6 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
References
► | URL | Tags | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2025-0528", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-01-17T14:48:04.184225Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-01-17T14:48:09.167Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "references": [ { "tags": [ "exploit" ], "url": "https://github.com/Pr0b1em/IoT/blob/master/TendaAC10v16.03.10.20telnet.md" } ], "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "modules": [ "HTTP Request Handler" ], "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.10.20" } ] }, { "modules": [ "HTTP Request Handler" ], "product": "AC10", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.10.20" } ] }, { "modules": [ "HTTP Request Handler" ], "product": "AC18", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.10.20" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "Pr0b1em (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda AC8, AC10 and AC18 16.03.10.20 entdeckt. Dies betrifft einen unbekannten Teil der Datei /goform/telnet der Komponente HTTP Request Handler. Durch Beeinflussen mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV4_0": { "baseScore": 8.6, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } }, { "cvssV3_1": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 7.2, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 8.3, "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-77", "description": "Command Injection", "lang": "en", "type": "CWE" } ] }, { "descriptions": [ { "cweId": "CWE-74", "description": "Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-17T14:31:07.148Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-292412 | Tenda AC8/AC10/AC18 HTTP Request telnet command injection", "tags": [ "vdb-entry" ], "url": "https://vuldb.com/?id.292412" }, { "name": "VDB-292412 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.292412" }, { "name": "Submit #478175 | Tenda AC10v4.0 v16.03.10.20 Command Injection", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.478175" }, { "tags": [ "exploit" ], "url": "https://github.com/Pr0b1em/IoT/blob/master/TendaAC10v16.03.10.20telnet.md" }, { "tags": [ "product" ], "url": "https://www.tenda.com.cn/" } ], "timeline": [ { "lang": "en", "time": "2025-01-17T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2025-01-17T01:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2025-01-17T07:54:02.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC8/AC10/AC18 HTTP Request telnet command injection" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2025-0528", "datePublished": "2025-01-17T14:31:07.148Z", "dateReserved": "2025-01-17T06:28:25.730Z", "dateUpdated": "2025-01-17T14:48:09.167Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-38937 (GCVE-0-2023-38937)
Vulnerability from cvelistv5
Published
2023-08-07 00:00
Modified
2024-10-17 14:40
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:54:39.643Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:ac6:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac6", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V2.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac1206", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V15.03.06.23" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4 V16.03.34.06" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac7", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.44" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac5", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V1.0 V15.03.06.28" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac9", "vendor": "tenda", "versions": [ { "status": "affected", "version": "V3.0 V15.03.06.42_multi" } ] }, { "cpes": [ "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac10", "vendor": "tenda", "versions": [ { "status": "affected", "version": "v4.0 V16.03.10.13" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-38937", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-17T14:37:17.298133Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-17T14:40:31.909Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-07T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-38937", "datePublished": "2023-08-07T00:00:00", "dateReserved": "2023-07-25T00:00:00", "dateUpdated": "2024-10-17T14:40:31.909Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2024-4064 (GCVE-0-2024-4064)
Vulnerability from cvelistv5
Published
2024-04-23 20:00
Modified
2024-09-03 18:17
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
► | URL | Tags | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T20:26:57.300Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-261790 | Tenda AC8 execCommand R7WebsSecurityHandler stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.261790" }, { "name": "VDB-261790 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.261790" }, { "name": "Submit #316493 | Tenda AC8v4 V16.03.34.09 buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.316493" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ac8_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "16.03.34.09" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-4064", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-07T19:08:53.437699Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-03T18:17:48.583Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "AC8", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "16.03.34.09" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda AC8 16.03.34.09 wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Es geht um die Funktion R7WebsSecurityHandler der Datei /goform/execCommand. Dank Manipulation des Arguments password mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-23T20:00:05.584Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-261790 | Tenda AC8 execCommand R7WebsSecurityHandler stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.261790" }, { "name": "VDB-261790 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.261790" }, { "name": "Submit #316493 | Tenda AC8v4 V16.03.34.09 buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.316493" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-23T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-23T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-23T15:27:29.000Z", "value": "VulDB entry last update" } ], "title": "Tenda AC8 execCommand R7WebsSecurityHandler stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4064", "datePublished": "2024-04-23T20:00:05.584Z", "dateReserved": "2024-04-23T13:22:19.761Z", "dateUpdated": "2024-09-03T18:17:48.583Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2025-01-17 15:15
Modified
2025-05-28 14:42
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/Pr0b1em/IoT/blob/master/TendaAC10v16.03.10.20telnet.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.292412 | Permissions Required, Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.292412 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.478175 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product | |
134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://github.com/Pr0b1em/IoT/blob/master/TendaAC10v16.03.10.20telnet.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.10.20 | |
tenda | ac8 | - | |
tenda | ac10_firmware | 16.03.10.20 | |
tenda | ac10 | - | |
tenda | ac18_firmware | 16.03.10.20 | |
tenda | ac18 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.10.20:*:*:*:*:*:*:*", "matchCriteriaId": "C9DEE72F-A151-4CF5-81C5-EF7BEBC83BDE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "C81F1E48-0204-4478-A937-5D40CDD9E5E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.20:*:*:*:*:*:*:*", "matchCriteriaId": "A19C486B-52A3-4C3E-851D-F349E8E0A706", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9E0489C-31D5-43C4-B15D-1D88119EF226", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:16.03.10.20:*:*:*:*:*:*:*", "matchCriteriaId": "0D1F3C30-9CD0-410F-AB8A-4BD8B15D7ABB", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se ha encontrado una vulnerabilidad clasificada como cr\u00edtica en Tenda AC8, AC10 y AC18 16.03.10.20. Este problema afecta a una funcionalidad desconocida del archivo /goform/telnet del componente HTTP Request Handler. La manipulaci\u00f3n conduce a la inyecci\u00f3n de comandos. El ataque puede ejecutarse de forma remota. El exploit se ha hecho p\u00fablico y puede utilizarse." } ], "id": "CVE-2025-0528", "lastModified": "2025-05-28T14:42:21.953", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "MULTIPLE", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 6.4, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "HIGH", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-01-17T15:15:12.430", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Pr0b1em/IoT/blob/master/TendaAC10v16.03.10.20telnet.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.292412" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.292412" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.478175" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Pr0b1em/IoT/blob/master/TendaAC10v16.03.10.20telnet.md" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-74" }, { "lang": "en", "value": "CWE-77" } ], "source": "cna@vuldb.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-10-18 20:15
Modified
2024-10-28 16:06
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compare_parentcontrol_time of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This is not the same issue like CVE-2023-33671. The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/JohenanLi/router_vuls/blob/main/ac8v4/compare_parentcontrol_time_vul.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.280915 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.280915 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?submit.421340 | Third Party Advisory | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.06. It has been declared as critical. Affected by this vulnerability is the function compare_parentcontrol_time of the file /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This is not the same issue like CVE-2023-33671. The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se ha encontrado una vulnerabilidad en Tenda AC8 16.03.34.06. Se ha declarado como cr\u00edtica. La funci\u00f3n compare_parentcontrol_time del archivo /goform/saveParentControlInfo se ve afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento time provoca un desbordamiento del b\u00fafer basado en la pila. El ataque se puede ejecutar de forma remota. El exploit se ha divulgado al p\u00fablico y puede utilizarse. No se trata del mismo problema que CVE-2023-33671. Se contact\u00f3 al proveedor con anticipaci\u00f3n sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-10123", "lastModified": "2024-10-28T16:06:53.747", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2024-10-18T20:15:02.960", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/JohenanLi/router_vuls/blob/main/ac8v4/compare_parentcontrol_time_vul.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.280915" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?id.280915" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?submit.421340" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-06-02 20:15
Modified
2025-01-08 21:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "C81F1E48-0204-4478-A937-5D40CDD9E5E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function." } ], "id": "CVE-2023-33673", "lastModified": "2025-01-08T21:15:10.503", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-06-02T20:15:09.693", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N6/README.md" }, { "source": "cve@mitre.org", "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N6" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N6/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N6" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-23 21:15
Modified
2025-01-21 18:55
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/fromAdvSetMacMtuWan.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.261792 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.261792 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.316495 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/fromAdvSetMacMtuWan.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.261792 | Permissions Required, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.261792 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.316495 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.09 | |
tenda | ac8 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*", "matchCriteriaId": "EE69F412-6FC7-470D-BC7E-B3AAC6B4585F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "C81F1E48-0204-4478-A937-5D40CDD9E5E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Una vulnerabilidad ha sido encontrada en Tenda AC8 16.03.34.09 y clasificada como cr\u00edtica. La funci\u00f3n fromAdvSetMacMtuWan del fichero /goform/AdvSetMacMtuWan es afectada por la vulnerabilidad. La manipulaci\u00f3n del argumento wanMTU/wanSpeed/cloneType/mac/serviceName/serverName provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible lanzar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador de esta vulnerabilidad es VDB-261792. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-4066", "lastModified": "2025-01-21T18:55:06.723", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-04-23T21:15:49.040", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/fromAdvSetMacMtuWan.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261792" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.261792" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.316495" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/fromAdvSetMacMtuWan.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261792" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.261792" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.316495" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-10-18 22:15
Modified
2024-10-28 16:08
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/JohenanLi/router_vuls/blob/main/ac8v4/FUN_004a8838.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.280918 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.280918 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?submit.422141 | Third Party Advisory | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se ha encontrado una vulnerabilidad clasificada como cr\u00edtica en Tenda AC8 16.03.34.06. Esta vulnerabilidad afecta a la funci\u00f3n formSetRebootTimer del archivo /goform/SetSysAutoRebbotCfg. La manipulaci\u00f3n del argumento rebootTime provoca un desbordamiento del b\u00fafer basado en la pila. El ataque se puede iniciar de forma remota. El exploit se ha hecho p\u00fablico y puede utilizarse. Se contact\u00f3 al proveedor con anticipaci\u00f3n sobre esta revelaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-10130", "lastModified": "2024-10-28T16:08:57.147", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2024-10-18T22:15:04.683", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/JohenanLi/router_vuls/blob/main/ac8v4/FUN_004a8838.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.280918" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?id.280918" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?submit.422141" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-02-20 23:15
Modified
2025-03-17 17:00
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/jangfan/my-vuln/blob/main/Tenda/AC8V4/saveParentControlInfo.md | Broken Link, Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | v4 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:v4:*:*:*:*:*:*:*", "matchCriteriaId": "6EE6A734-72E7-4358-BCA3-A0F1225A8EFB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info." }, { "lang": "es", "value": "Se descubri\u00f3 que Tenda AC8V4 V16.03.34.06 contiene un desbordamiento de pila a trav\u00e9s del par\u00e1metro urls en la funci\u00f3n get_parentControl_list_Info." } ], "id": "CVE-2025-25667", "lastModified": "2025-03-17T17:00:39.953", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-02-20T23:15:12.560", "references": [ { "source": "cve@mitre.org", "tags": [ "Broken Link", "Exploit", "Third Party Advisory" ], "url": "https://github.com/jangfan/my-vuln/blob/main/Tenda/AC8V4/saveParentControlInfo.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2025-03-24 21:15
Modified
2025-04-01 20:06
Severity ?
Summary
Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the parameter list.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:*:*:*:*:*:*:*:*", "matchCriteriaId": "262CFBE2-A086-424E-86F8-8E1C7C72D159", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the parameter list." }, { "lang": "es", "value": "Tenda AC8 V16.03.34.06 es vulnerable al desbordamiento del b\u00fafer en la funci\u00f3n fromSetRouteStatic a trav\u00e9s de la lista de par\u00e1metros." } ], "id": "CVE-2025-29100", "lastModified": "2025-04-01T20:06:53.017", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-03-24T21:15:17.673", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://gist.github.com/Raining-101/b2bd27d16cdca94d330150a8ead9caa8" }, { "source": "cve@mitre.org", "tags": [ "Exploit" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/Tenda%20a8%20V16.03.34.06%20fromSetRouteStatic_stack_overflow.md" }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "tags": [ "Exploit" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/Tenda%20a8%20V16.03.34.06%20fromSetRouteStatic_stack_overflow.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2025-07-24 15:15
Modified
2025-07-28 17:00
Severity ?
Summary
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/fast_setting_wifi_set. The manipulation of the argument `timeZone` leads to stack-based buffer overflow.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://tenda.com | Not Applicable | |
cve@mitre.org | https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51082.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/fast_setting_wifi_set. The manipulation of the argument `timeZone` leads to stack-based buffer overflow." }, { "lang": "es", "value": "Se detect\u00f3 un desbordamiento de pila en Tenda AC8V4 V16.03.34.06 en /goform/fast_setting_wifi_set. La manipulaci\u00f3n del argumento `timeZone` provoca un desbordamiento de b\u00fafer en la pila." } ], "id": "CVE-2025-51082", "lastModified": "2025-07-28T17:00:35.920", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-07-24T15:15:26.453", "references": [ { "source": "cve@mitre.org", "tags": [ "Not Applicable" ], "url": "http://tenda.com" }, { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51082.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2025-07-24 15:15
Modified
2025-07-28 17:01
Severity ?
Summary
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/SetSysTimeCfg. The manipulation of the argument `timeZone` and `timeType` leads to stack-based buffer overflow.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://tenda.com | Not Applicable | |
cve@mitre.org | https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51085.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/SetSysTimeCfg. The manipulation of the argument `timeZone` and `timeType` leads to stack-based buffer overflow." }, { "lang": "es", "value": "Se detect\u00f3 un desbordamiento de pila en Tenda AC8V4 V16.03.34.06 en /goform/SetSysTimeCfg. La manipulaci\u00f3n de los argumentos `timeZone` y `timeType` provoca un desbordamiento de b\u00fafer basado en la pila." } ], "id": "CVE-2025-51085", "lastModified": "2025-07-28T17:01:51.990", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-07-24T15:15:26.577", "references": [ { "source": "cve@mitre.org", "tags": [ "Not Applicable" ], "url": "http://tenda.com" }, { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51085.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2025-02-20 23:15
Modified
2025-03-17 15:10
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC8V4 V16.03.34.06. Affected is the function SUB_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/jangfan/my-vuln/blob/main/Tenda/AC8V4/WifiExtraSet.md | Exploit, Third Party Advisory, Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8V4 V16.03.34.06. Affected is the function SUB_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow." }, { "lang": "es", "value": "Se ha detectado una vulnerabilidad en Tenda AC8V4 V16.03.34.06. La funci\u00f3n SUB_0046AC38 del archivo /goform/WifiExtraSet est\u00e1 afectada. La manipulaci\u00f3n del argumento wpapsk_crypto provoca un desbordamiento del b\u00fafer basado en la pila." } ], "id": "CVE-2025-25663", "lastModified": "2025-03-17T15:10:12.850", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-02-20T23:15:12.350", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/jangfan/my-vuln/blob/main/Tenda/AC8V4/WifiExtraSet.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2025-06-06 20:15
Modified
2025-06-09 19:08
Severity ?
Summary
A vulnerability was found in Tenda AC8 16.03.34.09. It has been classified as critical. Affected is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeType leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://lavender-bicycle-a5a.notion.site/Tenda-AC8-fromSetSysTime-20a53a41781f807b9489fff42f262e11?source=copy_link | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.311352 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.311352 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.591266 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product | |
134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://lavender-bicycle-a5a.notion.site/Tenda-AC8-fromSetSysTime-20a53a41781f807b9489fff42f262e11 | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.09 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*", "matchCriteriaId": "EE69F412-6FC7-470D-BC7E-B3AAC6B4585F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.09. It has been classified as critical. Affected is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeType leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC8 16.03.34.09. Se ha clasificado como cr\u00edtica. La funci\u00f3n fromSetSysTime del archivo /goform/SetSysTimeCfg est\u00e1 afectada. La manipulaci\u00f3n del argumento timeType provoca un desbordamiento del b\u00fafer basado en la pila. Es posible ejecutar el ataque de forma remota. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-5798", "lastModified": "2025-06-09T19:08:05.903", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "PROOF_OF_CONCEPT", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-06-06T20:15:23.577", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC8-fromSetSysTime-20a53a41781f807b9489fff42f262e11?source=copy_link" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.311352" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.311352" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.591266" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC8-fromSetSysTime-20a53a41781f807b9489fff42f262e11" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 | |
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 | |
tenda | ac10_firmware | 16.03.10.13 | |
tenda | ac10 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*", "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function." } ], "id": "CVE-2023-38935", "lastModified": "2024-11-21T08:14:28.643", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:11.277", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetQosBand/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-06-02 20:15
Modified
2025-01-08 21:15
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "C81F1E48-0204-4478-A937-5D40CDD9E5E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function." } ], "id": "CVE-2023-33672", "lastModified": "2025-01-08T21:15:10.270", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-06-02T20:15:09.647", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N2/README.md" }, { "source": "cve@mitre.org", "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N2" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N2/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N2" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2025-01-16 23:15
Modified
2025-03-17 15:04
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
4.6 (Medium) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N
4.6 (Medium) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N
Summary
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Pr0b1em/IoT/blob/master/Tenda%20AC8v4%20V16.03.34.06.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow." }, { "lang": "es", "value": "Tenda AC8v4 V16.03.34.06 tiene una vulnerabilidad de desbordamiento de pila. La funci\u00f3n setSchedWifi del archivo /goform/openSchedWifi se ve afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento schedStartTime provoca un desbordamiento del b\u00fafer basado en la pila." } ], "id": "CVE-2024-57704", "lastModified": "2025-03-17T15:04:57.907", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.1, "impactScore": 2.5, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-01-16T23:15:08.113", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Pr0b1em/IoT/blob/master/Tenda%20AC8v4%20V16.03.34.06.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2025-07-24 15:15
Modified
2025-07-28 17:04
Severity ?
Summary
Tenda AC8V4 V16.03.34.06` was discovered to contain heap overflow at /goform/GetParentControlInfo.The manipulation of the argument `mac` leads to heap-based buffer overflow.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://tenda.com | Not Applicable | |
cve@mitre.org | https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51089.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06` was discovered to contain heap overflow at /goform/GetParentControlInfo.The manipulation of the argument `mac` leads to heap-based buffer overflow." }, { "lang": "es", "value": "Se descubri\u00f3 que Tenda AC8V4 V16.03.34.06` contiene un desbordamiento de mont\u00f3n en /goform/GetParentControlInfo. La manipulaci\u00f3n del argumento `mac` provoca un desbordamiento de b\u00fafer basado en mont\u00f3n." } ], "id": "CVE-2025-51089", "lastModified": "2025-07-28T17:04:40.397", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 2.5, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-07-24T15:15:26.993", "references": [ { "source": "cve@mitre.org", "tags": [ "Not Applicable" ], "url": "http://tenda.com" }, { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51089.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-122" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2025-07-24 15:15
Modified
2025-07-28 17:04
Severity ?
Summary
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/WifiGuestSet. The manipulation of the argument `shareSpeed` leads to stack-based buffer overflow.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://tenda.com | Not Applicable | |
cve@mitre.org | https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51088.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/WifiGuestSet. The manipulation of the argument `shareSpeed` leads to stack-based buffer overflow." }, { "lang": "es", "value": "Se detect\u00f3 un desbordamiento de pila en Tenda AC8V4 V16.03.34.06 en /goform/WifiGuestSet. La manipulaci\u00f3n del argumento `shareSpeed` provoca un desbordamiento de b\u00fafer basado en la pila." } ], "id": "CVE-2025-51088", "lastModified": "2025-07-28T17:04:02.997", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-07-24T15:15:26.877", "references": [ { "source": "cve@mitre.org", "tags": [ "Not Applicable" ], "url": "http://tenda.com" }, { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51088.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac10_firmware | 15.03.06.23 | |
tenda | ac10 | 1.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | ac10_firmware | 16.03.10.13 | |
tenda | ac10 | 4.0 | |
tenda | ac9_firmware | 15.03.06.42_multi | |
tenda | ac9 | 3.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*", "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*", "matchCriteriaId": "7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function." } ], "id": "CVE-2023-38937", "lastModified": "2024-11-21T08:14:28.943", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:11.413", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-02-21 17:15
Modified
2025-04-10 13:36
Severity ?
Summary
Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the get_parentControl_list_Info function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/faqiadegege/IoTVuln/blob/main/tendaAC8_get_parentControl_list_Info_urls_overflow/detail.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "C81F1E48-0204-4478-A937-5D40CDD9E5E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the get_parentControl_list_Info function." }, { "lang": "es", "value": "Tenda AC8 V16.03.34.06 es vulnerable a un desbordamiento de b\u00fafer en la funci\u00f3n get_parentControl_list_Info." } ], "id": "CVE-2025-25510", "lastModified": "2025-04-10T13:36:28.503", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 2.5, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-02-21T17:15:14.567", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/faqiadegege/IoTVuln/blob/main/tendaAC8_get_parentControl_list_Info_urls_overflow/detail.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2025-02-20 23:15
Modified
2025-03-17 15:19
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/jangfan/my-vuln/blob/main/Tenda/AC8V4/SetIpMacBind.md | Exploit, Third Party Advisory, Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 function." }, { "lang": "es", "value": "Se descubri\u00f3 que Tenda AC8V4 V16.03.34.06 contiene un desbordamiento de pila a trav\u00e9s del par\u00e1metro shareSpeed en la funci\u00f3n sub_49E098." } ], "id": "CVE-2025-25664", "lastModified": "2025-03-17T15:19:50.133", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-02-20T23:15:12.453", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory", "Broken Link" ], "url": "https://github.com/jangfan/my-vuln/blob/main/Tenda/AC8V4/SetIpMacBind.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-09-04 00:15
Modified
2024-11-21 08:35
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/GleamingEyes/vul/blob/main/tenda_ac8/ac8_1.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.238633 | Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?id.238633 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/GleamingEyes/vul/blob/main/tenda_ac8/ac8_1.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.238633 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.238633 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.06_cn_TDC01. It has been declared as critical. Affected by this vulnerability is the function formSetDeviceName. The manipulation leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-238633 was assigned to this vulnerability." }, { "lang": "es", "value": "Una vulnerabilidad declarada como cr\u00edtica ha sido encontrada en Tenda AC8 16.03.34.06_cn_TDC01. La funci\u00f3n afectada por esta vulnerabilidad es formSetDeviceName. La manipulaci\u00f3n conduce a un desbordamiento del b\u00fafer. El ataque se puede lanzar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-238633." } ], "id": "CVE-2023-4744", "lastModified": "2024-11-21T08:35:52.997", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-09-04T00:15:07.463", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/GleamingEyes/vul/blob/main/tenda_ac8/ac8_1.md" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?ctiid.238633" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.238633" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/GleamingEyes/vul/blob/main/tenda_ac8/ac8_1.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?ctiid.238633" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?id.238633" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-05-06 16:15
Modified
2025-05-13 20:19
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability, which was classified as critical, was found in Tenda AC8 16.03.34.06. Affected is the function formGetRouterStatus of the file /goform/MtuSetMacWan. The manipulation of the argument shareSpeed leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/fjl1113/cve/blob/main/Tenda.md | Broken Link | |
cna@vuldb.com | https://vuldb.com/?ctiid.307488 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.307488 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.564812 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "C81F1E48-0204-4478-A937-5D40CDD9E5E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda AC8 16.03.34.06. Affected is the function formGetRouterStatus of the file /goform/MtuSetMacWan. The manipulation of the argument shareSpeed leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad clasificada como cr\u00edtica en Tenda AC8 16.03.34.06. La funci\u00f3n formGetRouterStatus del archivo /goform/MtuSetMacWan est\u00e1 afectada. La manipulaci\u00f3n del argumento shareSpeed provoca un desbordamiento del b\u00fafer. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-4368", "lastModified": "2025-05-13T20:19:54.440", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-05-06T16:15:32.037", "references": [ { "source": "cna@vuldb.com", "tags": [ "Broken Link" ], "url": "https://github.com/fjl1113/cve/blob/main/Tenda.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.307488" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.307488" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.564812" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-120" } ], "source": "cna@vuldb.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-23 20:15
Modified
2025-01-21 19:12
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.261790 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.261790 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.316493 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.261790 | Permissions Required, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.261790 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.316493 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.09 | |
tenda | ac8 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*", "matchCriteriaId": "EE69F412-6FC7-470D-BC7E-B3AAC6B4585F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "C81F1E48-0204-4478-A937-5D40CDD9E5E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC8 16.03.34.09. Ha sido declarada cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n R7WebsSecurityHandler del archivo /goform/execCommand. La manipulaci\u00f3n del argumento contrase\u00f1a provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. VDB-261790 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-4064", "lastModified": "2025-01-21T19:12:43.877", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-04-23T20:15:07.997", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261790" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.261790" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.316493" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261790" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.261790" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.316493" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-11-26 21:15
Modified
2024-12-03 15:25
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://tasty-foxtrot-3a8.notion.site/Tenda-AC8v4-route_static_check-stack-overflow-1460448e6195803087a5d39755d2bb6b?pvs=74 | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.286142 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.286142 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?submit.449893 | Third Party Advisory | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.09 | |
tenda | ac8 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*", "matchCriteriaId": "EE69F412-6FC7-470D-BC7E-B3AAC6B4585F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "C81F1E48-0204-4478-A937-5D40CDD9E5E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se ha detectado una vulnerabilidad en Tenda AC8 16.03.34.09 que se ha clasificado como cr\u00edtica. Este problema afecta a la funci\u00f3n route_static_check del archivo /goform/SetStaticRouteCfg. La manipulaci\u00f3n de la lista de argumentos provoca un desbordamiento del b\u00fafer basado en la pila. El ataque puede ejecutarse de forma remota. El exploit se ha hecho p\u00fablico y puede utilizarse." } ], "id": "CVE-2024-11745", "lastModified": "2024-12-03T15:25:28.847", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2024-11-26T21:15:06.733", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://tasty-foxtrot-3a8.notion.site/Tenda-AC8v4-route_static_check-stack-overflow-1460448e6195803087a5d39755d2bb6b?pvs=74" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.286142" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?id.286142" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://vuldb.com/?submit.449893" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-03-19 17:15
Modified
2025-04-01 20:36
Severity ?
Summary
Tenda AC8 V16.03.34.06 was discovered to contain a stack overflow via the src parameter in the function sub_47D878.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:*:*:*:*:*:*:*:*", "matchCriteriaId": "262CFBE2-A086-424E-86F8-8E1C7C72D159", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8 V16.03.34.06 was discovered to contain a stack overflow via the src parameter in the function sub_47D878." }, { "lang": "es", "value": "Se descubri\u00f3 que Tenda AC8 V16.03.34.06 contiene un desbordamiento de pila a trav\u00e9s del par\u00e1metro src en la funci\u00f3n sub_47D878." } ], "id": "CVE-2025-29118", "lastModified": "2025-04-01T20:36:54.203", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-03-19T17:15:41.377", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/tenda-ac8_sub_47D878.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-06-02 20:15
Modified
2025-01-08 21:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub_44db3c function.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "C81F1E48-0204-4478-A937-5D40CDD9E5E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the timeZone parameter in the sub_44db3c function." } ], "id": "CVE-2023-33669", "lastModified": "2025-01-08T21:15:09.473", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-06-02T20:15:09.520", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N1/README.md" }, { "source": "cve@mitre.org", "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N1" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N1/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N1" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-09-20 16:15
Modified
2025-03-17 15:00
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability in the fromAdvSetMacMtuWan function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/zp9080/Tenda/blob/main/Tenda-AC8v4%20V16.03.34.06-fromAdvSetMacMtuWan/overview.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability in the fromAdvSetMacMtuWan function." }, { "lang": "es", "value": "Tenda AC8v4 V16.03.34.06 tiene una vulnerabilidad de desbordamiento de pila en la funci\u00f3n fromAdvSetMacMtuWan." } ], "id": "CVE-2024-46652", "lastModified": "2025-03-17T15:00:28.117", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2024-09-20T16:15:05.063", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/zp9080/Tenda/blob/main/Tenda-AC8v4%20V16.03.34.06-fromAdvSetMacMtuWan/overview.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2025-01-16 23:15
Modified
2025-03-17 14:59
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
7.3 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
Summary
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Pr0b1em/IoT/blob/master/Tenda%20AC8v4%20V16.03.34.06.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow." }, { "lang": "es", "value": " Tenda AC8v4 V16.03.34.06 tiene una vulnerabilidad de desbordamiento de pila. La funci\u00f3n setSchedWifi del archivo /goform/openSchedWifi se ve afectada por esta vulnerabilidad. La manipulaci\u00f3n del argumento schedEndTime provoca un desbordamiento del b\u00fafer basado en la pila." } ], "id": "CVE-2024-57703", "lastModified": "2025-03-17T14:59:32.307", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 2.1, "impactScore": 5.2, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-01-16T23:15:08.003", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Pr0b1em/IoT/blob/master/Tenda%20AC8v4%20V16.03.34.06.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-04-23 20:15
Modified
2025-01-21 19:05
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/formSetRebootTimer.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.261791 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.261791 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.316494 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/formSetRebootTimer.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.261791 | Permissions Required, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.261791 | Permissions Required, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?submit.316494 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.09 | |
tenda | ac8 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*", "matchCriteriaId": "EE69F412-6FC7-470D-BC7E-B3AAC6B4585F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "C81F1E48-0204-4478-A937-5D40CDD9E5E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC8 16.03.34.09. Ha sido calificada como cr\u00edtica. Este problema afecta a la funci\u00f3n formSetRebootTimer del archivo /goform/SetRebootTimer. La manipulaci\u00f3n del argumento rebootTime provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-261791. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera." } ], "id": "CVE-2024-4065", "lastModified": "2025-01-21T19:05:04.657", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-04-23T20:15:08.223", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/formSetRebootTimer.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261791" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?id.261791" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.316494" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/formSetRebootTimer.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.261791" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?id.261791" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.316494" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-07-24 15:15
Modified
2025-07-28 17:02
Severity ?
Summary
Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | http://tenda.com | Not Applicable | |
cve@mitre.org | https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51087.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow." }, { "lang": "es", "value": "Se detect\u00f3 un desbordamiento de pila en Tenda AC8V4 V16.03.34.06 en /goform/saveParentControlInfo. La manipulaci\u00f3n del tiempo del argumento provoca un desbordamiento de b\u00fafer en la pila." } ], "id": "CVE-2025-51087", "lastModified": "2025-07-28T17:02:56.940", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 4.7, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-07-24T15:15:26.693", "references": [ { "source": "cve@mitre.org", "tags": [ "Not Applicable" ], "url": "http://tenda.com" }, { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/TL-SN/IOT/blob/main/Tenda/Tenda-AC8v4%20%20V16.03.34.06/CVE-2025-51087.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2025-03-03 06:15
Modified
2025-03-05 21:28
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda AC8 16.03.34.06 and classified as critical. This issue affects the function sub_49E098 of the file /goform/SetIpMacBind of the component Parameter Handler. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/Raining-101/IOT_cve/blob/main/tenda-ac8_sub_49E098.md | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.298121 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.298121 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.505374 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "C81F1E48-0204-4478-A937-5D40CDD9E5E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.06 and classified as critical. This issue affects the function sub_49E098 of the file /goform/SetIpMacBind of the component Parameter Handler. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se ha detectado una vulnerabilidad en Tenda AC8 16.03.34.06 que se ha clasificado como cr\u00edtica. Este problema afecta a la funci\u00f3n sub_49E098 del archivo /goform/SetIpMacBind del componente Parameter Handler. La manipulaci\u00f3n de la lista de argumentos provoca un desbordamiento del b\u00fafer basado en la pila. El ataque puede iniciarse de forma remota. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-1853", "lastModified": "2025-03-05T21:28:00.130", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-03-03T06:15:21.697", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/tenda-ac8_sub_49E098.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.298121" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.298121" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.505374" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-06-02 20:15
Modified
2025-01-08 21:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "C81F1E48-0204-4478-A937-5D40CDD9E5E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the get_parentControl_list_Info function." } ], "id": "CVE-2023-33675", "lastModified": "2025-01-08T21:15:10.757", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-06-02T20:15:09.733", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N5/README.md" }, { "source": "cve@mitre.org", "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N5" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N5/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N5" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-10-23 14:15
Modified
2024-11-01 14:03
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md | Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.281555 | Permissions Required, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?id.281555 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.426417 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac15_firmware | 15.03.05.18 | |
tenda | ac15_firmware | 15.03.05.19 | |
tenda | ac15 | - | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | - | |
tenda | ac10u_firmware | 15.03.06.48 | |
tenda | ac10u_firmware | 15.03.06.49 | |
tenda | ac10u | - | |
tenda | ac500_firmware | 1.0.0.14 | |
tenda | ac500_firmware | 1.0.0.16 | |
tenda | ac500_firmware | 2.0.1.9\(1307\) | |
tenda | ac500 | - | |
tenda | ac18_firmware | 15.03.05.05 | |
tenda | ac18_firmware | 15.03.05.19\(6318\) | |
tenda | ac18 | - | |
tenda | ac9_firmware | 15.03.2.13 | |
tenda | ac9_firmware | 15.03.05.14 | |
tenda | ac9_firmware | 15.03.05.19\(6318\) | |
tenda | ac9 | 1.0 | |
tenda | ac9_firmware | 15.03.06.42 | |
tenda | ac9 | 3.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac10_firmware | 16.03.10.13 | |
tenda | ac10_firmware | 16.03.10.20 | |
tenda | ac10 | 4.0 | |
tenda | ac10_firmware | 16.03.48.19 | |
tenda | ac10_firmware | 16.03.48.23 | |
tenda | ac10 | 5.0 | |
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8_firmware | 16.03.34.09 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.18:*:*:*:*:*:*:*", "matchCriteriaId": "56881C41-A993-45CC-BAE6-E9DE17FA56E2", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*", "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "A3BEE979-5BF3-48ED-AF42-0546D4F896E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.48:*:*:*:*:*:*:*", "matchCriteriaId": "1C2AFD04-833D-4085-BAD6-32A2715FA785", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac10u_firmware:15.03.06.49:*:*:*:*:*:*:*", "matchCriteriaId": "0F101E88-BEA9-4017-9048-860DF3D1BBBC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10u:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDBE5E26-7967-4FDD-A29F-7740B29C4B8E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac500_firmware:1.0.0.14:*:*:*:*:*:*:*", "matchCriteriaId": "61BA4026-93A8-4D83-815E-397A2EC0A279", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac500_firmware:1.0.0.16:*:*:*:*:*:*:*", "matchCriteriaId": "816A7A37-5952-4B22-80F7-8CD09383E079", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac500_firmware:2.0.1.9\\(1307\\):*:*:*:*:*:*:*", "matchCriteriaId": "2F0EEFAB-B3B0-4C10-A712-7A35F5FD076E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac500:-:*:*:*:*:*:*:*", "matchCriteriaId": "64192A8B-CC65-44EC-942B-CC16AADF0D69", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*", "matchCriteriaId": "4D5CB727-FC6B-4212-A61E-2888A0DADFB0", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*", "matchCriteriaId": "3AC468E5-44D1-4B94-B308-C1025DB1BB7B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.2.13:*:*:*:*:*:*:*", "matchCriteriaId": "3473D6FD-4D42-46D0-9D96-F95D6D856E8E", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.14:*:*:*:*:*:*:*", "matchCriteriaId": "DA7503C5-02C6-4016-A4C6-414146719BFF", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.05.19\\(6318\\):*:*:*:*:*:*:*", "matchCriteriaId": "D8F25141-8B57-463D-AB97-F52C0143973C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "566DA530-18FC-4A46-95B4-2A7D343A96A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42:*:*:*:*:*:*:*", "matchCriteriaId": "5B0A5168-9E0C-43F7-BF7B-3943A3316CB8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "7F482F89-B0F6-450D-B675-43EC0A9E6A4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*", "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.20:*:*:*:*:*:*:*", "matchCriteriaId": "A19C486B-52A3-4C3E-851D-F349E8E0A706", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.48.19:*:*:*:*:*:*:*", "matchCriteriaId": "DABA74C0-297A-4372-B84D-00BA0D334318", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.48.23:*:*:*:*:*:*:*", "matchCriteriaId": "AC3020CA-7422-4B9A-AA7B-C2B1A03A4450", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:5.0:*:*:*:*:*:*:*", "matchCriteriaId": "2BCFFBD6-3DAD-4FEA-9B5D-D7CBFC36572D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true }, { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*", "matchCriteriaId": "EE69F412-6FC7-470D-BC7E-B3AAC6B4585F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se ha detectado una vulnerabilidad en Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 y AC1206 hasta 20241022. Se ha calificado como problem\u00e1tica. Este problema afecta a la funci\u00f3n websReadEvent del archivo /goform/GetIPTV. La manipulaci\u00f3n del argumento Content-Length provoca la desreferenciaci\u00f3n de puntero nulo. El ataque puede iniciarse de forma remota. El exploit se ha hecho p\u00fablico y puede utilizarse." } ], "id": "CVE-2024-10280", "lastModified": "2024-11-01T14:03:20.267", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 6.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "cna@vuldb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2024-10-23T14:15:04.500", "references": [ { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory" ], "url": "https://github.com/JohenanLi/router_vuls/blob/main/websReadEvent/websReadEvent.md" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required", "VDB Entry" ], "url": "https://vuldb.com/?ctiid.281555" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.281555" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.426417" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-476" } ], "source": "cna@vuldb.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-03-20 13:15
Modified
2025-03-25 17:37
Severity ?
Summary
Tenda AC8V4.0 V16.03.34.06 was discovered to contain a stack overflow via the deviceid parameter in the get_parentControl_list_Info function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/Raining-101/IOT_cve/blob/main/tenda-ac8_get_parentControl_list_Info_overflow.md | Exploit, Third Party Advisory | |
134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://github.com/Raining-101/IOT_cve/blob/main/tenda-ac8_get_parentControl_list_Info_overflow.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4.0 V16.03.34.06 was discovered to contain a stack overflow via the deviceid parameter in the get_parentControl_list_Info function." }, { "lang": "es", "value": "Se descubri\u00f3 que Tenda AC8V4.0 V16.03.34.06 contiene un desbordamiento de pila a trav\u00e9s del par\u00e1metro deviceid en la funci\u00f3n get_parentControl_list_Info." } ], "id": "CVE-2025-29101", "lastModified": "2025-03-25T17:37:22.543", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-03-20T13:15:36.467", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/tenda-ac8_get_parentControl_list_Info_overflow.md" }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/Raining-101/IOT_cve/blob/main/tenda-ac8_get_parentControl_list_Info_overflow.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-06-02 20:15
Modified
2025-01-08 21:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "C81F1E48-0204-4478-A937-5D40CDD9E5E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the deviceId parameter in the saveParentControlInfo function." } ], "id": "CVE-2023-33671", "lastModified": "2025-01-08T21:15:10.023", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-06-02T20:15:09.607", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N4/README.md" }, { "source": "cve@mitre.org", "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N4" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N4/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N4" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2025-02-20 23:15
Modified
2025-03-17 16:59
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_47D878 function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/jangfan/my-vuln/blob/main/Tenda/AC8V4/setMacFilterCfg.md | Broken Link, Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | v4 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:v4:*:*:*:*:*:*:*", "matchCriteriaId": "6EE6A734-72E7-4358-BCA3-A0F1225A8EFB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_47D878 function." }, { "lang": "es", "value": "Se descubri\u00f3 que Tenda AC8V4 V16.03.34.06 contiene un desbordamiento de pila a trav\u00e9s del par\u00e1metro shareSpeed en la funci\u00f3n sub_47D878." } ], "id": "CVE-2025-25668", "lastModified": "2025-03-17T16:59:59.693", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2025-02-20T23:15:12.660", "references": [ { "source": "cve@mitre.org", "tags": [ "Broken Link", "Exploit", "Third Party Advisory" ], "url": "https://github.com/jangfan/my-vuln/blob/main/Tenda/AC8V4/setMacFilterCfg.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-06-02 20:15
Modified
2025-01-08 21:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "C81F1E48-0204-4478-A937-5D40CDD9E5E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC8V4.0-V16.03.34.06 was discovered to contain a stack overflow via the time parameter in the sub_4a79ec function." } ], "id": "CVE-2023-33670", "lastModified": "2025-01-08T21:15:09.780", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }, "published": "2023-06-02T20:15:09.563", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N3/README.md" }, { "source": "cve@mitre.org", "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N3" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/DDizzzy79/Tenda-CVE/blob/main/AC8V4.0/N3/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://github.com/DDizzzy79/Tenda-CVE/tree/main/AC8V4.0/N3" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2023-08-07 19:15
Modified
2024-11-21 08:14
Severity ?
Summary
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function.
References
▶ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac10_firmware | 15.03.06.23 | |
tenda | ac10 | 1.0 | |
tenda | ac1206_firmware | 15.03.06.23 | |
tenda | ac1206 | - | |
tenda | ac8_firmware | 16.03.34.06 | |
tenda | ac8 | 4.0 | |
tenda | ac6_firmware | 15.03.06.23 | |
tenda | ac6 | 2.0 | |
tenda | ac7_firmware | 15.03.06.44 | |
tenda | ac7 | 1.0 | |
tenda | f1203_firmware | 2.0.1.6 | |
tenda | f1203 | - | |
tenda | ac5_firmware | 15.03.06.28 | |
tenda | ac5 | 1.0 | |
tenda | ac10_firmware | 16.03.10.13 | |
tenda | ac10 | 4.0 | |
tenda | fh1203_firmware | 2.0.1.6 | |
tenda | fh1203 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "66ED84F0-B0EB-4F55-9AD6-C8B682BAB472", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "AF790B76-6CAD-483A-95FA-80955643825B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "787A50A1-EDBC-44EB-8CF2-11C4FC63719D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*", "matchCriteriaId": "29D5013D-520A-461A-95FF-43B2BE160F91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*", "matchCriteriaId": "9C1D64DC-1EDC-4F62-8D22-E1890B71843C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "D82FD30C-AF3C-4E3B-B674-002A5C9ED09D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E382AD7E-1450-40FC-AE9D-698B491805F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*", "matchCriteriaId": "4D94B37C-491D-4E7C-8273-F46FEDA62C9F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "96503617-6B69-4862-ADFE-4EF379876F0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "0B3530E4-70D6-4246-84CA-E25797329DE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FB77DC8-C11D-418A-AB87-5FE0226CA6CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*", "matchCriteriaId": "7F928648-C8B2-4D37-8343-C74AABEFAB07", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "D141716B-56F0-4061-9D87-943B7858F2F4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*", "matchCriteriaId": "6F1C8715-D7B4-4D1A-9E90-079C72049332", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "970AEBF4-2B32-4633-A75B-2D2C598C048D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*", "matchCriteriaId": "E28AF51D-EBFB-4EC8-9FCB-C3DFAE1DBB2E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E7A0DCB-AC18-4F32-86E2-F2C2E9118A71", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function." } ], "id": "CVE-2023-38931", "lastModified": "2024-11-21T08:14:28.000", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-08-07T19:15:10.977", "references": [ { "source": "cve@mitre.org", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2025-06-06 20:15
Modified
2025-06-09 19:07
Severity ?
Summary
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
References
▶ | URL | Tags | |
---|---|---|---|
cna@vuldb.com | https://lavender-bicycle-a5a.notion.site/Tenda-AC8-fromSetWirelessRepeat-20a53a41781f803d9156f0babaf94fca?source=copy_link | Exploit, Third Party Advisory | |
cna@vuldb.com | https://vuldb.com/?ctiid.311353 | Permissions Required | |
cna@vuldb.com | https://vuldb.com/?id.311353 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://vuldb.com/?submit.591270 | Third Party Advisory, VDB Entry | |
cna@vuldb.com | https://www.tenda.com.cn/ | Product | |
134c704f-9b21-4f2e-91b3-4a467353bcc0 | https://lavender-bicycle-a5a.notion.site/Tenda-AC8-fromSetWirelessRepeat-20a53a41781f803d9156f0babaf94fca | Exploit, Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
tenda | ac8_firmware | 16.03.34.09 | |
tenda | ac8 | 4.0 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.09:*:*:*:*:*:*:*", "matchCriteriaId": "EE69F412-6FC7-470D-BC7E-B3AAC6B4585F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*", "matchCriteriaId": "655619B2-6E8B-4D2E-98E7-028E69597E80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. Affected by this vulnerability is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used." }, { "lang": "es", "value": "Se encontr\u00f3 una vulnerabilidad en Tenda AC8 16.03.34.09. Se ha declarado cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n fromSetWirelessRepeat del archivo /goform/WifiExtraSet. La manipulaci\u00f3n del argumento wpapsk_crypto provoca un desbordamiento del b\u00fafer basado en la pila. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado." } ], "id": "CVE-2025-5799", "lastModified": "2025-06-09T19:07:59.197", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "cna@vuldb.com", "type": "Secondary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cna@vuldb.com", "type": "Secondary" } ], "cvssMetricV40": [ { "cvssData": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "PROOF_OF_CONCEPT", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "source": "cna@vuldb.com", "type": "Secondary" } ] }, "published": "2025-06-06T20:15:23.770", "references": [ { "source": "cna@vuldb.com", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC8-fromSetWirelessRepeat-20a53a41781f803d9156f0babaf94fca?source=copy_link" }, { "source": "cna@vuldb.com", "tags": [ "Permissions Required" ], "url": "https://vuldb.com/?ctiid.311353" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?id.311353" }, { "source": "cna@vuldb.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://vuldb.com/?submit.591270" }, { "source": "cna@vuldb.com", "tags": [ "Product" ], "url": "https://www.tenda.com.cn/" }, { "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC8-fromSetWirelessRepeat-20a53a41781f803d9156f0babaf94fca" } ], "sourceIdentifier": "cna@vuldb.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" }, { "lang": "en", "value": "CWE-121" } ], "source": "cna@vuldb.com", "type": "Secondary" } ] }