Vulnerabilites related to Cambium Networks - cnPilot
CVE-2017-5263 (GCVE-0-2017-5263)
Vulnerability from cvelistv5
Published
2017-12-20 22:00
Modified
2024-08-05 14:55
Severity ?
CWE
  • CWE-352 - (Cross-Site Request Forgery (CSRF))
Summary
Versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware lack CSRF controls that can mitigate the effects of CSRF attacks, which are most typically implemented as randomized per-session tokens associated with any web application function, especially destructive ones.
Impacted products
Vendor Product Version
Cambium Networks cnPilot Version: 4.3.2-R4 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:55:35.817Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "cnPilot",
          "vendor": "Cambium Networks",
          "versions": [
            {
              "status": "affected",
              "version": "4.3.2-R4 and prior"
            }
          ]
        }
      ],
      "datePublic": "2017-12-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware lack CSRF controls that can mitigate the effects of CSRF attacks, which are most typically implemented as randomized per-session tokens associated with any web application function, especially destructive ones."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-352",
              "description": "CWE-352 (Cross-Site Request Forgery (CSRF))",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-20T21:57:01",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "ID": "CVE-2017-5263",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "cnPilot",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.3.2-R4 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cambium Networks"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware lack CSRF controls that can mitigate the effects of CSRF attacks, which are most typically implemented as randomized per-session tokens associated with any web application function, especially destructive ones."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-352 (Cross-Site Request Forgery (CSRF))"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/",
              "refsource": "MISC",
              "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2017-5263",
    "datePublished": "2017-12-20T22:00:00",
    "dateReserved": "2017-01-09T00:00:00",
    "dateUpdated": "2024-08-05T14:55:35.817Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-5262 (GCVE-0-2017-5262)
Vulnerability from cvelistv5
Published
2017-12-20 22:00
Modified
2024-08-05 14:55
Severity ?
CWE
Summary
In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, the SNMP read-only (RO) community string has access to sensitive information by OID reference.
Impacted products
Vendor Product Version
Cambium Networks cnPilot Version: 4.3.2-R4 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:55:35.706Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "cnPilot",
          "vendor": "Cambium Networks",
          "versions": [
            {
              "status": "affected",
              "version": "4.3.2-R4 and prior"
            }
          ]
        }
      ],
      "datePublic": "2017-12-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, the SNMP read-only (RO) community string has access to sensitive information by OID reference."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 (Information Exposure)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-20T21:57:01",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "ID": "CVE-2017-5262",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "cnPilot",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.3.2-R4 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cambium Networks"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, the SNMP read-only (RO) community string has access to sensitive information by OID reference."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200 (Information Exposure)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/",
              "refsource": "MISC",
              "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2017-5262",
    "datePublished": "2017-12-20T22:00:00",
    "dateReserved": "2017-01-09T00:00:00",
    "dateUpdated": "2024-08-05T14:55:35.706Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-5259 (GCVE-0-2017-5259)
Vulnerability from cvelistv5
Published
2017-12-20 22:00
Modified
2024-08-05 14:55
Severity ?
CWE
Summary
In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, an undocumented, root-privilege administration web shell is available using the HTTP path https://<device-ip-or-hostname>/adm/syscmd.asp.
Impacted products
Vendor Product Version
Cambium Networks cnPilot Version: 4.3.2-R4 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:55:35.778Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "cnPilot",
          "vendor": "Cambium Networks",
          "versions": [
            {
              "status": "affected",
              "version": "4.3.2-R4 and prior"
            }
          ]
        }
      ],
      "datePublic": "2017-12-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, an undocumented, root-privilege administration web shell is available using the HTTP path https://\u003cdevice-ip-or-hostname\u003e/adm/syscmd.asp."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-489",
              "description": "CWE-489 (Leftover Debug Code)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-20T21:57:01",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "ID": "CVE-2017-5259",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "cnPilot",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.3.2-R4 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cambium Networks"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, an undocumented, root-privilege administration web shell is available using the HTTP path https://\u003cdevice-ip-or-hostname\u003e/adm/syscmd.asp."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-489 (Leftover Debug Code)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/",
              "refsource": "MISC",
              "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2017-5259",
    "datePublished": "2017-12-20T22:00:00",
    "dateReserved": "2017-01-09T00:00:00",
    "dateUpdated": "2024-08-05T14:55:35.778Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-5260 (GCVE-0-2017-5260)
Vulnerability from cvelistv5
Published
2017-12-20 22:00
Modified
2024-08-05 14:55
Severity ?
CWE
  • CWE-472 - (External Control of Assumed-Immutable Web Parameter)
Summary
In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, although the option to access the configuration file is not available in the normal web administrative console for the 'user' account, the configuration file is accessible via direct object reference (DRO) at http://<device-ip-or-hostname>/goform/down_cfg_file by this otherwise low privilege 'user' account.
Impacted products
Vendor Product Version
Cambium Networks cnPilot Version: 4.3.2-R4 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:55:35.713Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "cnPilot",
          "vendor": "Cambium Networks",
          "versions": [
            {
              "status": "affected",
              "version": "4.3.2-R4 and prior"
            }
          ]
        }
      ],
      "datePublic": "2017-12-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, although the option to access the configuration file is not available in the normal web administrative console for the \u0027user\u0027 account, the configuration file is accessible via direct object reference (DRO) at http://\u003cdevice-ip-or-hostname\u003e/goform/down_cfg_file by this otherwise low privilege \u0027user\u0027 account."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-472",
              "description": "CWE-472 (External Control of Assumed-Immutable Web Parameter)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-20T21:57:01",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "ID": "CVE-2017-5260",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "cnPilot",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.3.2-R4 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cambium Networks"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, although the option to access the configuration file is not available in the normal web administrative console for the \u0027user\u0027 account, the configuration file is accessible via direct object reference (DRO) at http://\u003cdevice-ip-or-hostname\u003e/goform/down_cfg_file by this otherwise low privilege \u0027user\u0027 account."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-472 (External Control of Assumed-Immutable Web Parameter)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/",
              "refsource": "MISC",
              "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2017-5260",
    "datePublished": "2017-12-20T22:00:00",
    "dateReserved": "2017-01-09T00:00:00",
    "dateUpdated": "2024-08-05T14:55:35.713Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-5261 (GCVE-0-2017-5261)
Vulnerability from cvelistv5
Published
2017-12-20 22:00
Modified
2024-08-05 14:55
Severity ?
CWE
  • CWE-472 - (External Control of Assumed-Immutable Web Parameter)
Summary
In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, the 'ping' and 'traceroute' functions of the web administrative console expose a file path traversal vulnerability, accessible to all authenticated users.
Impacted products
Vendor Product Version
Cambium Networks cnPilot Version: 4.3.2-R4 and prior
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:55:35.709Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "cnPilot",
          "vendor": "Cambium Networks",
          "versions": [
            {
              "status": "affected",
              "version": "4.3.2-R4 and prior"
            }
          ]
        }
      ],
      "datePublic": "2017-12-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, the \u0027ping\u0027 and \u0027traceroute\u0027 functions of the web administrative console expose a file path traversal vulnerability, accessible to all authenticated users."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-472",
              "description": "CWE-472 (External Control of Assumed-Immutable Web Parameter)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-20T21:57:01",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "ID": "CVE-2017-5261",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "cnPilot",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "4.3.2-R4 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cambium Networks"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In versions 4.3.2-R4 and prior of Cambium Networks cnPilot firmware, the \u0027ping\u0027 and \u0027traceroute\u0027 functions of the web administrative console expose a file path traversal vulnerability, accessible to all authenticated users."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-472 (External Control of Assumed-Immutable Web Parameter)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/",
              "refsource": "MISC",
              "url": "https://blog.rapid7.com/2017/12/19/r7-2017-25-cambium-epmp-and-cnpilot-multiple-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2017-5261",
    "datePublished": "2017-12-20T22:00:00",
    "dateReserved": "2017-01-09T00:00:00",
    "dateUpdated": "2024-08-05T14:55:35.709Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",