Vulnerabilites related to rockwellautomation - connected_component_workbench
Vulnerability from fkie_nvd
Published
2022-05-17 20:15
Modified
2024-11-21 06:40
Severity ?
8.6 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://www.cisa.gov/uscert/ics/advisories/icsa-22-095-01 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-22-095-01 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:rockwellautomation:connected_component_workbench:*:*:*:*:*:*:*:*", "matchCriteriaId": "68034639-8E86-45CE-97EA-AAC8EAEE6600", "versionEndIncluding": "13.00.00", "vulnerable": true }, { "criteria": "cpe:2.3:a:rockwellautomation:isagraf_workbench:*:*:*:*:*:*:*:*", "matchCriteriaId": "54E95041-485F-48A3-A3C3-AA59F74EF64E", "versionEndIncluding": "6.6.9", "versionStartIncluding": "6.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:rockwellautomation:safety_instrumented_systems_workstation:*:*:*:*:*:*:*:*", "matchCriteriaId": "0CDC3A7A-94B0-4B10-B478-C8C9E1FAD73C", "versionEndIncluding": "1.2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited" }, { "lang": "es", "value": "Connected Components Workbench (versiones v13.00.00 y anteriores), ISaGRAF Workbench (versiones v6.0 hasta v6.6.9), y Safety Instrumented System Workstation (versiones v1.2 y anteriores (para Trusted Controllers)) no limitan los objetos que pueden ser deserializados. Esto permite a atacantes dise\u00f1ar un objeto serializado malicioso que, si es abierto por un usuario local en Connected Components Workbench, puede resultar en una ejecuci\u00f3n de c\u00f3digo arbitrario. Esta vulnerabilidad requiere la interacci\u00f3n del usuario para ser explotada con \u00e9xito" } ], "id": "CVE-2022-1118", "lastModified": "2024-11-21T06:40:05.017", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 6.0, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-05-17T20:15:08.173", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-095-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-095-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-502" } ], "source": "ics-cert@hq.dhs.gov", "type": "Primary" } ] }
CVE-2022-1118 (GCVE-0-2022-1118)
Vulnerability from cvelistv5
Published
2022-05-17 19:47
Modified
2025-04-16 17:54
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-502 - Deserialization of Untrusted Data
Summary
Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Rockwell Automation | Connected Component Workbench |
Version: All < |
|||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T23:55:23.946Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-095-01" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2022-1118", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2025-04-16T17:29:15.658155Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-04-16T17:54:25.317Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Connected Component Workbench", "vendor": "Rockwell Automation", "versions": [ { "lessThanOrEqual": "v13.00.00", "status": "affected", "version": "All ", "versionType": "custom" } ] }, { "product": "ISaGRAF Workbench", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "All v6.0 through v6.6.9" } ] }, { "product": "Safety Instrumented Systems Workstation", "vendor": "Rockwell Automation", "versions": [ { "lessThanOrEqual": "v1.2 (for Trusted Controllers)", "status": "affected", "version": "All", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-502", "description": "CWE-502 Deserialization of Untrusted Data", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-17T19:47:10.000Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-095-01" } ], "source": { "advisory": "ICSA-22-095-01", "discovery": "UNKNOWN" }, "title": "Rockwell Automation ISaGRAF Deserialization of Untrusted Data", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-1118", "STATE": "PUBLIC", "TITLE": "Rockwell Automation ISaGRAF Deserialization of Untrusted Data" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Connected Component Workbench", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All ", "version_value": "v13.00.00" } ] } }, { "product_name": "ISaGRAF Workbench", "version": { "version_data": [ { "version_affected": "=", "version_name": "All", "version_value": "v6.0 through v6.6.9" } ] } }, { "product_name": "Safety Instrumented Systems Workstation", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "All", "version_value": "v1.2 (for Trusted Controllers)" } ] } } ] }, "vendor_name": "Rockwell Automation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited" } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-502 Deserialization of Untrusted Data" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-095-01", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-095-01" } ] }, "source": { "advisory": "ICSA-22-095-01", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-1118", "datePublished": "2022-05-17T19:47:10.000Z", "dateReserved": "2022-03-28T00:00:00.000Z", "dateUpdated": "2025-04-16T17:54:25.317Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }