Vulnerabilites related to automationdirect - d0-06ar_firmware
Vulnerability from fkie_nvd
Published
2022-08-31 16:15
Modified
2024-11-21 07:00
Summary
AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;
References



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06dd1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AFBA65E-338B-4236-BCA6-FA305930A8F4",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06dd1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F961CF86-3277-4EDB-A5B2-7EB305BACCD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06dd2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8FDFC703-2915-4CF7-97A8-BE4F2007E4F9",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06dd2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E91FF447-5939-4521-915E-517F0E16B0A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06dr_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C2B1AF8-9448-428E-8FF3-D862C66241B0",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06dr:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7BEE237B-5775-4610-B431-44E124D880A0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06da_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0567F254-00C6-4B3F-A24A-C5605B9A1A6F",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06da:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "677B72A1-2582-4635-900A-F99192633727",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06ar_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D5F91FD-8F20-4BCF-9F0B-3E3A3029A31A",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06ar:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5E373157-8264-49FE-AB64-4C5B46BC7DB5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06aa_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86D28B71-15E7-43F4-90F4-A5CD1081C05F",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06aa:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "13D409FE-21AA-48B6-83EF-2F5205649538",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06dd1-d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5751A9A-844A-48C6-A0DB-9BFE1A5E5285",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06dd1-d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9112C3CC-5D82-44AC-8F6D-0F57EE4D6199",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06dd2-d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1E5DC0D-DF94-4FF0-B831-22288823B80B",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06dd2-d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "57D5814E-B776-43BF-84F6-17A366350F57",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06dr-d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "440477AD-8CCA-4F8E-ADA4-DF6B2C973B2F",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06dr-d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B38DA966-2520-44AB-9DC0-680A0F578177",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;"
    },
    {
      "lang": "es",
      "value": "AutomationDirect DirectLOGIC es vulnerable a un mensaje serie espec\u00edficamente dise\u00f1ado para el puerto serie de la CPU que causar\u00e1 que el PLC responda con la contrase\u00f1a del PLC en texto sin cifrar. Esto podr\u00eda permitir a un atacante acceder y realizar cambios no autorizados. Este problema afecta a: CPUs de la serie D0-06 de AutomationDirect D0-06DD1 versiones anteriores a 2.72; D0-06DD2 versiones anteriores a 2.72; D0-06DR versiones anteriores a 2.72; D0-06DA versiones anteriores a 2.72; D0-06AR versiones anteriores a 2.72; D0-06AA versiones anteriores a 2.72; D0-06DD1-D versiones anteriores a 2.72; D0-06DD2-D versiones anteriores a 2.72; D0-06DR-D versiones anteriores a 2.72"
    }
  ],
  "id": "CVE-2022-2003",
  "lastModified": "2024-11-21T07:00:09.463",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 7.7,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.5,
        "impactScore": 5.2,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-08-31T16:15:10.393",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-02"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-319"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-08-31 16:15
Modified
2024-11-21 07:00
Summary
AutomationDirect DirectLOGIC is vulnerable to a a specially crafted packet can be sent continuously to the PLC to prevent access from DirectSoft and other devices, causing a denial-of-service condition. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03Patch, Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03Patch, Third Party Advisory, US Government Resource



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06dd1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AFBA65E-338B-4236-BCA6-FA305930A8F4",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06dd1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F961CF86-3277-4EDB-A5B2-7EB305BACCD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06dd2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8FDFC703-2915-4CF7-97A8-BE4F2007E4F9",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06dd2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E91FF447-5939-4521-915E-517F0E16B0A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06dr_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C2B1AF8-9448-428E-8FF3-D862C66241B0",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06dr:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7BEE237B-5775-4610-B431-44E124D880A0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06da_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0567F254-00C6-4B3F-A24A-C5605B9A1A6F",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06da:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "677B72A1-2582-4635-900A-F99192633727",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06ar_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D5F91FD-8F20-4BCF-9F0B-3E3A3029A31A",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06ar:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5E373157-8264-49FE-AB64-4C5B46BC7DB5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06aa_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86D28B71-15E7-43F4-90F4-A5CD1081C05F",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06aa:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "13D409FE-21AA-48B6-83EF-2F5205649538",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06dd1-d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5751A9A-844A-48C6-A0DB-9BFE1A5E5285",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06dd1-d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9112C3CC-5D82-44AC-8F6D-0F57EE4D6199",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06dd2-d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1E5DC0D-DF94-4FF0-B831-22288823B80B",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06dd2-d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "57D5814E-B776-43BF-84F6-17A366350F57",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:automationdirect:d0-06dr-d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "440477AD-8CCA-4F8E-ADA4-DF6B2C973B2F",
              "versionEndExcluding": "2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:automationdirect:d0-06dr-d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B38DA966-2520-44AB-9DC0-680A0F578177",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "AutomationDirect DirectLOGIC is vulnerable to a a specially crafted packet can be sent continuously to the PLC to prevent access from DirectSoft and other devices, causing a denial-of-service condition. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;"
    },
    {
      "lang": "es",
      "value": "AutomationDirect DirectLOGIC es vulnerable a un paquete especialmente dise\u00f1ado puede ser enviado continuamente al PLC para evitar el acceso de DirectSoft y otros dispositivos, causando una condici\u00f3n de denegaci\u00f3n de servicio. Este problema afecta a: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versiones anteriores a 2.72; D0-06DD2 versiones anteriores a 2.72; D0-06DR versiones anteriores a 2.72; D0-06DA versiones anteriores a 2.72; D0-06AR versiones anteriores a 2.72; D0-06AA versiones anteriores a 2.72; D0-06DD1-D versiones anteriores a 2.72; D0-06DD2-D versiones anteriores a 2.72; D0-06DR-D versiones anteriores a 2.72;"
    }
  ],
  "id": "CVE-2022-2004",
  "lastModified": "2024-11-21T07:00:09.590",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-08-31T16:15:10.460",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Primary"
    }
  ]
}

CVE-2022-2003 (GCVE-0-2022-2003)
Vulnerability from cvelistv5
Published
2022-08-31 15:59
Modified
2025-04-16 17:49
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Summary
AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;
Impacted products
Vendor Product Version
AutomationDirect DirectLOGIC D0-06 series CPUs Version: D0-06DD1   < 2.72
Version: D0-06DD2   < 2.72
Version: D0-06DR   < 2.72
Version: D0-06DA   < 2.72
Version: D0-06AR   < 2.72
Version: D0-06AA   < 2.72
Version: D0-06DD1-D   < 2.72
Version: D0-06DD2-D   < 2.72
Version: D0-06DR-D   < 2.72
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:24:44.055Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2003",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:27:42.525536Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:49:17.171Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DirectLOGIC D0-06 series CPUs",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DD1",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DD2",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DR",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DA",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06AR",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06AA",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DD1-D",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DD2-D",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DR-D",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Sam Hanson of Dragos reported this vulnerability to CISA."
        }
      ],
      "datePublic": "2022-06-16T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T15:59:33.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "AutomationDirect recommends users upgrade to firmware Version 2.72 or later, which will no longer respond with the password when requested with the specially crafted message.\n\nAdditional mitigation for brute force password access has also been added. Three incorrect password entries will result in a 3-hour lock out of password entry. Power cycle will allow subsequent password attempts.\n\nWhile automation networks and systems have built-in password protection schemes, this is only one step in securing the affected systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products, and other SCADA system products perform independent network security analysis to determine the proper level of security required for the application.\n\nAutomationDirect has identified the specific mitigation actions listed below:\n\nSecure physical access.\nIsolate and air gap networks when possible.\nConsider some of the AutomationDirect newer PLC families."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "AutomationDirect DirectLOGIC with Serial Communication Cleartext Transmission",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-06-16T17:00:00.000Z",
          "ID": "CVE-2022-2003",
          "STATE": "PUBLIC",
          "TITLE": "AutomationDirect DirectLOGIC with Serial Communication Cleartext Transmission"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DirectLOGIC D0-06 series CPUs",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DD1",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DD2",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DR",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DA",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06AR",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06AA",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DD1-D",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DD2-D",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DR-D",
                            "version_value": "2.72"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "AutomationDirect"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Sam Hanson of Dragos reported this vulnerability to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC password in cleartext. This could allow an attacker to access and make unauthorized changes. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-319 Cleartext Transmission of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-02",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-02"
            },
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "AutomationDirect recommends users upgrade to firmware Version 2.72 or later, which will no longer respond with the password when requested with the specially crafted message.\n\nAdditional mitigation for brute force password access has also been added. Three incorrect password entries will result in a 3-hour lock out of password entry. Power cycle will allow subsequent password attempts.\n\nWhile automation networks and systems have built-in password protection schemes, this is only one step in securing the affected systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products, and other SCADA system products perform independent network security analysis to determine the proper level of security required for the application.\n\nAutomationDirect has identified the specific mitigation actions listed below:\n\nSecure physical access.\nIsolate and air gap networks when possible.\nConsider some of the AutomationDirect newer PLC families."
          }
        ],
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2003",
    "datePublished": "2022-08-31T15:59:33.369Z",
    "dateReserved": "2022-06-06T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:49:17.171Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2004 (GCVE-0-2022-2004)
Vulnerability from cvelistv5
Published
2022-08-31 15:59
Modified
2025-04-16 16:11
CWE
  • CWE-400 - Uncontrolled Resource Consumption
Summary
AutomationDirect DirectLOGIC is vulnerable to a a specially crafted packet can be sent continuously to the PLC to prevent access from DirectSoft and other devices, causing a denial-of-service condition. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;
References
Impacted products
Vendor Product Version
AutomationDirect DirectLOGIC D0-06 series CPUs Version: D0-06DD1   < 2.72
Version: D0-06DD2   < 2.72
Version: D0-06DR   < 2.72
Version: D0-06DA   < 2.72
Version: D0-06AR   < 2.72
Version: D0-06AA   < 2.72
Version: D0-06DD1-D   < 2.72
Version: D0-06DD2-D   < 2.72
Version: D0-06DR-D   < 2.72
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:24:43.769Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2004",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:54:35.593506Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:11:14.677Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DirectLOGIC D0-06 series CPUs",
          "vendor": "AutomationDirect",
          "versions": [
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DD1",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DD2",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DR",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DA",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06AR",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06AA",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DD1-D",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DD2-D",
              "versionType": "custom"
            },
            {
              "lessThan": "2.72",
              "status": "affected",
              "version": "D0-06DR-D",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Sam Hanson of Dragos reported this vulnerability to CISA."
        }
      ],
      "datePublic": "2022-06-16T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "AutomationDirect DirectLOGIC is vulnerable to a a specially crafted packet can be sent continuously to the PLC to prevent access from DirectSoft and other devices, causing a denial-of-service condition. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400 Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-31T15:59:33.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "AutomationDirect recommends users upgrade to firmware Version 2.72 or later for all DL06 CPUs for CVE-2022-2002.\n\nAdditional brute force mitigation for password access has also been added. Three incorrect password entries will result in a three hour lock out of password entry. Power cycle will allow subsequent password attempts.\n\nPlease see the security network practices below for CVE-2022-2004.\nWhile automation networks and systems have built-in password protection schemes, this is only one step in securing the affected systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products, and other SCADA system products perform independent network security analysis to determine the proper level of security required for the application.\n\nAutomationDirect has identified the specific mitigation actions listed below:\n\nSecure physical access.\nIsolate and air gap networks when possible.\nConsider some of the AutomationDirect newer PLC families."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "AutomationDirect DirectLOGIC with Ethernet Communication Uncontrolled Resource Consumption",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-06-16T17:00:00.000Z",
          "ID": "CVE-2022-2004",
          "STATE": "PUBLIC",
          "TITLE": "AutomationDirect DirectLOGIC with Ethernet Communication Uncontrolled Resource Consumption"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DirectLOGIC D0-06 series CPUs",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DD1",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DD2",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DR",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DA",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06AR",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06AA",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DD1-D",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DD2-D",
                            "version_value": "2.72"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "D0-06DR-D",
                            "version_value": "2.72"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "AutomationDirect"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Sam Hanson of Dragos reported this vulnerability to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "AutomationDirect DirectLOGIC is vulnerable to a a specially crafted packet can be sent continuously to the PLC to prevent access from DirectSoft and other devices, causing a denial-of-service condition. This issue affects: AutomationDirect DirectLOGIC D0-06 series CPUs D0-06DD1 versions prior to 2.72; D0-06DD2 versions prior to 2.72; D0-06DR versions prior to 2.72; D0-06DA versions prior to 2.72; D0-06AR versions prior to 2.72; D0-06AA versions prior to 2.72; D0-06DD1-D versions prior to 2.72; D0-06DD2-D versions prior to 2.72; D0-06DR-D versions prior to 2.72;"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400 Uncontrolled Resource Consumption"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-167-03"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "AutomationDirect recommends users upgrade to firmware Version 2.72 or later for all DL06 CPUs for CVE-2022-2002.\n\nAdditional brute force mitigation for password access has also been added. Three incorrect password entries will result in a three hour lock out of password entry. Power cycle will allow subsequent password attempts.\n\nPlease see the security network practices below for CVE-2022-2004.\nWhile automation networks and systems have built-in password protection schemes, this is only one step in securing the affected systems. Automation control system networks must incorporate data protection and security measures at least as robust as a typical business computer system. AutomationDirect recommends users of PLCs, HMI products, and other SCADA system products perform independent network security analysis to determine the proper level of security required for the application.\n\nAutomationDirect has identified the specific mitigation actions listed below:\n\nSecure physical access.\nIsolate and air gap networks when possible.\nConsider some of the AutomationDirect newer PLC families."
          }
        ],
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2004",
    "datePublished": "2022-08-31T15:59:33.591Z",
    "dateReserved": "2022-06-06T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:11:14.677Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}