Vulnerabilites related to dlink - dir-809
Vulnerability from fkie_nvd
Published
2021-12-01 22:15
Modified
2024-11-21 06:08
Severity ?
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_800462c4 in /formAdvFirewall. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
dlink dir-809_firmware *
dlink dir-809 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-809_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83964738-E503-43D1-90AB-42C46699702B",
              "versionEndIncluding": "1.12wwb03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-809:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FD4771B-A3F0-4F1C-841C-D718AC7D8E40",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_800462c4 in /formAdvFirewall. This vulnerability is triggered via a crafted POST request."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que los dispositivos D-Link DIR-809 con versi\u00f3n de firmware hasta DIR-809Ax_FW1.12WB03_20190410, contienen una vulnerabilidad de desbordamiento del b\u00fafer de la pila en la funci\u00f3n FUN_800462c4 en /formAdvFirewall. Esta vulnerabilidad es desencadenada por medio de una petici\u00f3n POST dise\u00f1ada"
    }
  ],
  "id": "CVE-2021-33270",
  "lastModified": "2024-11-21T06:08:37.883",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-01T22:15:07.827",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln06"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln06"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-01 22:15
Modified
2024-11-21 06:08
Severity ?
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function sub_80046EB4 in /formSetPortTr. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
dlink dir-809_firmware *
dlink dir-809 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-809_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83964738-E503-43D1-90AB-42C46699702B",
              "versionEndIncluding": "1.12wwb03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-809:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FD4771B-A3F0-4F1C-841C-D718AC7D8E40",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function sub_80046EB4 in /formSetPortTr. This vulnerability is triggered via a crafted POST request."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que los dispositivos D-Link DIR-809 con versi\u00f3n de firmware hasta DIR-809Ax_FW1.12WB03_20190410, contienen una vulnerabilidad de desbordamiento del b\u00fafer de la pila en la funci\u00f3n sub_80046EB4 en /formSetPortTr. Esta vulnerabilidad es desencadenada por medio de una petici\u00f3n POST dise\u00f1ada"
    }
  ],
  "id": "CVE-2021-33271",
  "lastModified": "2024-11-21T06:08:38.040",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-01T22:15:07.863",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln11"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln11"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-01 22:15
Modified
2024-11-21 06:08
Severity ?
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_8004776c in /formVirtualApp. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
dlink dir-809_firmware *
dlink dir-809 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-809_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83964738-E503-43D1-90AB-42C46699702B",
              "versionEndIncluding": "1.12wwb03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-809:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FD4771B-A3F0-4F1C-841C-D718AC7D8E40",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_8004776c in /formVirtualApp. This vulnerability is triggered via a crafted POST request."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que los dispositivos D-Link DIR-809 con versi\u00f3n de firmware hasta DIR-809Ax_FW1.12WB03_20190410, contienen una vulnerabilidad de desbordamiento del b\u00fafer de la pila en la funci\u00f3n FUN_8004776c en /formVirtualApp. Esta vulnerabilidad es desencadenada por medio de una petici\u00f3n POST dise\u00f1ada"
    }
  ],
  "id": "CVE-2021-33266",
  "lastModified": "2024-11-21T06:08:34.643",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-01T22:15:07.647",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln04"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-01 22:15
Modified
2024-11-21 06:08
Severity ?
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80034d60 in /formStaticDHCP. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
dlink dir-809_firmware *
dlink dir-809 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-809_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83964738-E503-43D1-90AB-42C46699702B",
              "versionEndIncluding": "1.12wwb03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-809:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FD4771B-A3F0-4F1C-841C-D718AC7D8E40",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80034d60 in /formStaticDHCP. This vulnerability is triggered via a crafted POST request."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que los dispositivos D-Link DIR-809 con versi\u00f3n de firmware hasta DIR-809Ax_FW1.12WB03_20190410, contienen una vulnerabilidad de desbordamiento del b\u00fafer de la pila en la funci\u00f3n FUN_80034d60 en /formStaticDHCP. Esta vulnerabilidad es desencadenada por medio de una petici\u00f3n POST dise\u00f1ada"
    }
  ],
  "id": "CVE-2021-33267",
  "lastModified": "2024-11-21T06:08:37.420",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-01T22:15:07.690",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln02"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2015-05-01 15:59
Modified
2025-04-12 10:46
Summary
The miniigd SOAP service in Realtek SDK allows remote attackers to execute arbitrary code via a crafted NewInternalClient request, as exploited in the wild through 2023.
References
cve@mitre.orghttp://jvn.jp/en/jp/JVN47580234/index.htmlThird Party Advisory
cve@mitre.orghttp://jvn.jp/en/jp/JVN67456944/index.htmlThird Party Advisory
cve@mitre.orghttp://packetstormsecurity.com/files/132090/Realtek-SDK-Miniigd-UPnP-SOAP-Command-Execution.htmlThird Party Advisory, VDB Entry
cve@mitre.orghttp://securityadvisories.dlink.com/security/publication.aspx?name=SAP10055Vendor Advisory
cve@mitre.orghttp://www.securityfocus.com/bid/74330Broken Link, Third Party Advisory, VDB Entry
cve@mitre.orghttp://www.zerodayinitiative.com/advisories/ZDI-15-155/Third Party Advisory, VDB Entry
cve@mitre.orghttps://sensorstechforum.com/hinatabot-cve-2014-8361-ddos/Third Party Advisory
cve@mitre.orghttps://web.archive.org/web/20150909230440/http://securityadvisories.dlink.com/security/publication.aspx?name=SAP10055Third Party Advisory
cve@mitre.orghttps://www.exploit-db.com/exploits/37169/Third Party Advisory, VDB Entry
af854a3a-2127-422b-91ae-364da2661108http://jvn.jp/en/jp/JVN47580234/index.htmlThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108http://jvn.jp/en/jp/JVN67456944/index.htmlThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108http://packetstormsecurity.com/files/132090/Realtek-SDK-Miniigd-UPnP-SOAP-Command-Execution.htmlThird Party Advisory, VDB Entry
af854a3a-2127-422b-91ae-364da2661108http://securityadvisories.dlink.com/security/publication.aspx?name=SAP10055Vendor Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.securityfocus.com/bid/74330Broken Link, Third Party Advisory, VDB Entry
af854a3a-2127-422b-91ae-364da2661108http://www.zerodayinitiative.com/advisories/ZDI-15-155/Third Party Advisory, VDB Entry
af854a3a-2127-422b-91ae-364da2661108https://sensorstechforum.com/hinatabot-cve-2014-8361-ddos/Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://web.archive.org/web/20150909230440/http://securityadvisories.dlink.com/security/publication.aspx?name=SAP10055Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.exploit-db.com/exploits/37169/Third Party Advisory, VDB Entry



{
  "cisaActionDue": "2023-10-09",
  "cisaExploitAdd": "2023-09-18",
  "cisaRequiredAction": "Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.",
  "cisaVulnerabilityName": "Realtek SDK Improper Input Validation Vulnerability",
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-905l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "05CB91FD-6322-48FB-8CCE-3E7DDB622063",
              "versionEndIncluding": "2.05b01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-905l:a1:*:*:*:*:*:*:*",
              "matchCriteriaId": "F50CC55A-1EA1-4096-8489-1CE1E991B305",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:dlink:dir-905l:b1:*:*:*:*:*:*:*",
              "matchCriteriaId": "21EDEA1E-6F3C-4E92-A732-270D1E086576",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-605l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "01D15D52-C442-4ABE-917C-A50908082089",
              "versionEndIncluding": "1.14b06",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-605l:a1:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA9038E9-8519-4DC7-8843-74ADB3527A3F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-600l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "90962768-A07F-4A1E-9500-F743FD1ECA96",
              "versionEndIncluding": "1.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-600l:a1:*:*:*:*:*:*:*",
              "matchCriteriaId": "F75E7D9C-03BE-4301-AF9E-9929C33F4EEA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-619l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "22544CBE-CE28-4E13-99CD-9855A76F8EDF",
              "versionEndIncluding": "1.15",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-619l:a1:*:*:*:*:*:*:*",
              "matchCriteriaId": "3271958C-23CD-4937-A21A-905A18ECA736",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-619l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FCD4837-81DE-4C00-AC6C-0E7D6036E1D6",
              "versionEndIncluding": "2.07b02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-619l:b1:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F28B093-482C-4105-A89D-8B1F1FFD59E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-605l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "89CE2A47-DC82-49A7-874E-C9533E153ECF",
              "versionEndIncluding": "2.07b02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-605l:b1:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B1FC91F-1B77-406F-ADB5-98B07866601E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-605l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B8247C1-8A71-4004-8ECE-1984335D697D",
              "versionEndIncluding": "3.03b07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-605l:c1:*:*:*:*:*:*:*",
              "matchCriteriaId": "4DD38B14-B291-423A-912C-B1BB2070A9C9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-600l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C66EAA7D-A420-4CBF-AD01-754983012129",
              "versionEndIncluding": "2.056b06",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-600l:b1:*:*:*:*:*:*:*",
              "matchCriteriaId": "6966FB89-8C98-4FA3-B4CA-21CAD495A830",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-809_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4CCC25F5-5E8A-4164-84D8-DDC0D3519E2B",
              "versionEndIncluding": "1.04b02",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-809:a1:*:*:*:*:*:*:*",
              "matchCriteriaId": "184F3169-C4BE-4ABF-AFED-B8D39522092F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:dlink:dir-809:a2:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CE2F27F-A180-4459-8D73-5544568BB53D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-900l_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3757810-6826-4389-8621-A87267D71B64",
              "versionEndExcluding": "1.15b01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-900l:a1:*:*:*:*:*:*:*",
              "matchCriteriaId": "2396542D-7E98-41B4-9BF1-31CE699B0FF9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:realtek:realtek_sdk:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "62471288-17B2-4FCA-A673-CC4B24FB6262",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-501_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C1339C5-FD81-4885-AF24-A05BC1A3B02A",
              "versionEndIncluding": "1.01b04",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-501:a1:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A8C6464-A044-4C0B-8ADB-C2F61C3009E5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-515_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5FA66695-A646-4AB9-B128-A3D87C4C8284",
              "versionEndIncluding": "1.01b04",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-515:a1:*:*:*:*:*:*:*",
              "matchCriteriaId": "037A3A92-EC1C-41AC-A93A-7319E8E98240",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-615_firmware:10.01b02:*:*:*:*:*:*:*",
              "matchCriteriaId": "17FD57FF-A596-4151-860C-3F0486CD85F4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-615:j1:*:*:*:*:*:*:*",
              "matchCriteriaId": "30B14CF6-4239-4BAB-ABA0-284AFDA2C9E8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F41E73AD-5615-4084-AC4E-516A934303CA",
              "versionEndIncluding": "6.06b03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-615:fx:*:*:*:*:*:*:*",
              "matchCriteriaId": "63134C26-FEA9-4EF5-97D9-FEDA14B34516",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:wg1900hp2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A05F11D3-7701-4152-9937-04D7134B4FE6",
              "versionEndIncluding": "1.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:wg1900hp2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E007A9B5-74FE-4230-9E3E-ACEA89FCABA8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:wg1900hp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D0DD2168-9BE3-49E8-952D-4775911C04D6",
              "versionEndIncluding": "2.5.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:wg1900hp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "70FC2B64-D47F-42DF-B9B4-7FB07F98A150",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:wg1800hp4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BCE7372C-DB92-419F-877C-CCE0DC3EBD6C",
              "versionEndIncluding": "1.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:wg1800hp4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9BB5205-0D2E-43AF-B228-9C728B404EA3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:wg1800hp3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBDC178B-2033-47EA-B6CC-99880D5772A2",
              "versionEndIncluding": "1.5.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:wg1800hp3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD47CE10-EBD2-49A9-9F1A-B77A502AC196",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:wg1200hs2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "424AB1C2-6C52-4416-8983-53D4BCAA0F80",
              "versionEndIncluding": "2.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:wg1200hs2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC88BDE5-19B4-4EF4-8C14-2DEB8EAD3D91",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:wg1200hp3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7ED15E56-530C-42A3-B3D3-9F1090C524D5",
              "versionEndIncluding": "1.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:wg1200hp3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F13C13D3-FB31-4E20-A5D4-992D4CF6BBCC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:wg1200hp2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7FDD550-9FDE-4001-933E-51FF4FBDC5AA",
              "versionEndIncluding": "2.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:wg1200hp2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "347DFD5E-56E0-473F-A2B1-E3FD2E99573A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:w1200ex_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "88A2A125-9991-459A-99D2-5158B72372BD",
              "versionEndIncluding": "1.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:w1200ex:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6D0D008-E851-4756-87E4-5FA60EE65040",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:w1200ex-ms_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C69CCDC3-BB41-45F2-987D-674FAD937F40",
              "versionEndIncluding": "1.3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:w1200ex-ms:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EBD0A960-9FA2-4838-A867-7AC688749771",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:wg1200hs_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C5C80AB-4775-4D46-9FC7-C341CEAB08A0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:wg1200hs:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "05C494FC-4284-4325-A05C-DDAAF86857F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:wg1200hp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC81201F-93A7-4B54-A7FE-51E4FD12AE54",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:wg1200hp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E80DDB01-BA42-40E1-91A3-EBFCEC3F8A49",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:wf800hp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D83ABC6-AB7F-494C-B386-EB4212F50C55",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:wf800hp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "141077D2-4439-44AA-9BD1-C60E253B4C6F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:wf300hp2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EF09945-D1B9-45FF-87DF-1573DB5F51BC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:wf300hp2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "514DD5D5-E44F-432E-AE87-25DDA62636AB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:wr8165n_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "08699FDC-5E04-4CF3-9C9A-9231795A6420",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:wr8165n:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "90FC20CF-70E5-4E50-A383-E24CB0987280",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:w500p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54E372D5-C699-4ED4-9AB3-326ADC9834BB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:w500p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9CC1968-0B25-4324-AB07-688B32770220",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:aterm:w300p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B02F690-7098-4C8C-B453-3EC8C01F0343",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:aterm:w300p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A810B81E-8EE7-4F63-9380-7C68CB33B404",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The miniigd SOAP service in Realtek SDK allows remote attackers to execute arbitrary code via a crafted NewInternalClient request, as exploited in the wild through 2023."
    },
    {
      "lang": "es",
      "value": "El servicio SOAP miniigd en Realtek SDK permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de una solicitud NewInternalClient manipulada espec\u00edficamente, como se explot\u00f3 de forma activa hasta 2023."
    }
  ],
  "id": "CVE-2014-8361",
  "lastModified": "2025-04-12T10:46:40.837",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2015-05-01T15:59:01.287",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://jvn.jp/en/jp/JVN47580234/index.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://jvn.jp/en/jp/JVN67456944/index.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://packetstormsecurity.com/files/132090/Realtek-SDK-Miniigd-UPnP-SOAP-Command-Execution.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://securityadvisories.dlink.com/security/publication.aspx?name=SAP10055"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Broken Link",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/74330"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-155/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://sensorstechforum.com/hinatabot-cve-2014-8361-ddos/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://web.archive.org/web/20150909230440/http://securityadvisories.dlink.com/security/publication.aspx?name=SAP10055"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.exploit-db.com/exploits/37169/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://jvn.jp/en/jp/JVN47580234/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://jvn.jp/en/jp/JVN67456944/index.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://packetstormsecurity.com/files/132090/Realtek-SDK-Miniigd-UPnP-SOAP-Command-Execution.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://securityadvisories.dlink.com/security/publication.aspx?name=SAP10055"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/74330"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-155/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://sensorstechforum.com/hinatabot-cve-2014-8361-ddos/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://web.archive.org/web/20150909230440/http://securityadvisories.dlink.com/security/publication.aspx?name=SAP10055"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.exploit-db.com/exploits/37169/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-01 22:15
Modified
2024-11-21 06:08
Severity ?
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_8004776c in /formVirtualServ. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
dlink dir-809_firmware *
dlink dir-809 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-809_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83964738-E503-43D1-90AB-42C46699702B",
              "versionEndIncluding": "1.12wwb03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-809:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FD4771B-A3F0-4F1C-841C-D718AC7D8E40",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_8004776c in /formVirtualServ. This vulnerability is triggered via a crafted POST request."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que los dispositivos D-Link DIR-809 con versi\u00f3n de firmware hasta DIR-809Ax_FW1.12WB03_20190410, contienen una vulnerabilidad de desbordamiento del b\u00fafer de la pila en la funci\u00f3n FUN_8004776c en /formVirtualServ. Esta vulnerabilidad es desencadenada por medio de una petici\u00f3n POST dise\u00f1ada"
    }
  ],
  "id": "CVE-2021-33269",
  "lastModified": "2024-11-21T06:08:37.733",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-01T22:15:07.780",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln01"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-01 22:15
Modified
2024-11-21 06:08
Severity ?
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80040af8 in /formWlanSetup. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
dlink dir-809_firmware *
dlink dir-809 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-809_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83964738-E503-43D1-90AB-42C46699702B",
              "versionEndIncluding": "1.12wwb03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-809:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FD4771B-A3F0-4F1C-841C-D718AC7D8E40",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80040af8 in /formWlanSetup. This vulnerability is triggered via a crafted POST request."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que los dispositivos D-Link DIR-809 con versi\u00f3n de firmware hasta DIR-809Ax_FW1.12WB03_20190410, contienen una vulnerabilidad de desbordamiento del b\u00fafer de la pila en la funci\u00f3n FUN_80040af8 en /formWlanSetup. Esta vulnerabilidad es desencadenada por medio de una petici\u00f3n POST dise\u00f1ada"
    }
  ],
  "id": "CVE-2021-33274",
  "lastModified": "2024-11-21T06:08:38.187",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-01T22:15:07.907",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln07"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln07"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-01 22:15
Modified
2024-11-21 06:08
Severity ?
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80046eb4 in /formSetPortTr. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
dlink dir-809_firmware *
dlink dir-809 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-809_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83964738-E503-43D1-90AB-42C46699702B",
              "versionEndIncluding": "1.12wwb03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-809:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FD4771B-A3F0-4F1C-841C-D718AC7D8E40",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80046eb4 in /formSetPortTr. This vulnerability is triggered via a crafted POST request."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que los dispositivos D-Link DIR-809 con versi\u00f3n de firmware hasta DIR-809Ax_FW1.12WB03_20190410, contienen una vulnerabilidad de desbordamiento del b\u00fafer de la pila en la funci\u00f3n FUN_80046eb4 en /formSetPortTr. Esta vulnerabilidad es desencadenada por medio de una petici\u00f3n POST dise\u00f1ada"
    }
  ],
  "id": "CVE-2021-33265",
  "lastModified": "2024-11-21T06:08:34.490",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.2,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-01T22:15:07.557",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln05"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-01 22:15
Modified
2024-11-21 06:08
Severity ?
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function sub_8003183C in /fromLogin. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
dlink dir-809_firmware *
dlink dir-809 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-809_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83964738-E503-43D1-90AB-42C46699702B",
              "versionEndIncluding": "1.12wwb03",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-809:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FD4771B-A3F0-4F1C-841C-D718AC7D8E40",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function sub_8003183C in /fromLogin. This vulnerability is triggered via a crafted POST request."
    },
    {
      "lang": "es",
      "value": "Se ha detectado que los dispositivos D-Link DIR-809 con versi\u00f3n de firmware hasta DIR-809Ax_FW1.12WB03_20190410, contienen una vulnerabilidad de desbordamiento del b\u00fafer de la pila en la funci\u00f3n sub_8003183C en /fromLogin. Esta vulnerabilidad es desencadenada por medio de una petici\u00f3n POST dise\u00f1ada"
    }
  ],
  "id": "CVE-2021-33268",
  "lastModified": "2024-11-21T06:08:37.590",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-01T22:15:07.733",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln03"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.dlink.com/en/security-bulletin/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-10-09 17:29
Modified
2024-11-21 03:48
Severity ?
Summary
An issue was discovered on D-Link DIR-809 A1 through 1.09, A2 through 1.11, and Guest Zone through 1.09 devices. Device passwords, such as the admin password and the WPA key, are stored in cleartext.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:d-link:dir-809_a1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA79E6FC-1E52-4C38-88DB-B3A8D0567A1E",
              "versionEndIncluding": "1.09",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:d-link:dir-809_a2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAB04A2F-EE93-453C-A953-0491908CA242",
              "versionEndIncluding": "1.11",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:d-link:dir-809_guestzone_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "02C23BEA-B55D-41DF-A762-3B61752BA151",
              "versionEndIncluding": "1.09",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-809:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D348FC9-9375-4379-A631-C51A78F80D75",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on D-Link DIR-809 A1 through 1.09, A2 through 1.11, and Guest Zone through 1.09 devices. Device passwords, such as the admin password and the WPA key, are stored in cleartext."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en dispositivos D-Link DIR-809 A1 hasta la versi\u00f3n 1.09, A2 hasta la versi\u00f3n 1.11 y Guest Zone hasta la versi\u00f3n 1.09. Las contrase\u00f1as del dispositivo, como la contrase\u00f1a de administrador y la clave WPA, est\u00e1n almacenadas en texto claro."
    }
  ],
  "id": "CVE-2018-14081",
  "lastModified": "2024-11-21T03:48:35.100",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-10-09T17:29:00.973",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://blog.nivel4.com/investigaciones/nuevas-vulnerabilidades-en-router-d-link-permiten-tomar-control-remoto-del-dispositivo/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://blog.nivel4.com/investigaciones/nuevas-vulnerabilidades-en-router-d-link-permiten-tomar-control-remoto-del-dispositivo/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-10-09 17:29
Modified
2024-11-21 03:48
Summary
An issue was discovered on D-Link DIR-809 A1 through 1.09, A2 through 1.11, and Guest Zone through 1.09 devices. One can bypass authentication mechanisms to download the configuration file.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:d-link:dir-809_a1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA79E6FC-1E52-4C38-88DB-B3A8D0567A1E",
              "versionEndIncluding": "1.09",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:d-link:dir-809_a2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAB04A2F-EE93-453C-A953-0491908CA242",
              "versionEndIncluding": "1.11",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:d-link:dir-809_guestzone_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "02C23BEA-B55D-41DF-A762-3B61752BA151",
              "versionEndIncluding": "1.09",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-809:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D348FC9-9375-4379-A631-C51A78F80D75",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on D-Link DIR-809 A1 through 1.09, A2 through 1.11, and Guest Zone through 1.09 devices. One can bypass authentication mechanisms to download the configuration file."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema en dispositivos D-Link DIR-809 A1 hasta la versi\u00f3n 1.09, A2 hasta la versi\u00f3n 1.11 y Guest Zone hasta la versi\u00f3n 1.09. Se pueden omitir los mecanismos de autenticaci\u00f3n para descargar el archivo de configuraci\u00f3n."
    }
  ],
  "id": "CVE-2018-14080",
  "lastModified": "2024-11-21T03:48:34.950",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-10-09T17:29:00.863",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://blog.nivel4.com/investigaciones/nuevas-vulnerabilidades-en-router-d-link-permiten-tomar-control-remoto-del-dispositivo/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://blog.nivel4.com/investigaciones/nuevas-vulnerabilidades-en-router-d-link-permiten-tomar-control-remoto-del-dispositivo/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2021-33267 (GCVE-0-2021-33267)
Vulnerability from cvelistv5
Published
2021-12-01 21:20
Modified
2024-08-03 23:42
Severity ?
CWE
  • n/a
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80034d60 in /formStaticDHCP. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:42:20.289Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dlink.com/en/security-bulletin/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80034d60 in /formStaticDHCP. This vulnerability is triggered via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-01T21:20:54",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dlink.com/en/security-bulletin/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-33267",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80034d60 in /formStaticDHCP. This vulnerability is triggered via a crafted POST request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dlink.com/en/security-bulletin/",
              "refsource": "MISC",
              "url": "https://www.dlink.com/en/security-bulletin/"
            },
            {
              "name": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln02",
              "refsource": "MISC",
              "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-33267",
    "datePublished": "2021-12-01T21:20:54",
    "dateReserved": "2021-05-20T00:00:00",
    "dateUpdated": "2024-08-03T23:42:20.289Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-14081 (GCVE-0-2018-14081)
Vulnerability from cvelistv5
Published
2018-10-09 15:00
Modified
2024-08-05 09:21
Severity ?
CWE
  • n/a
Summary
An issue was discovered on D-Link DIR-809 A1 through 1.09, A2 through 1.11, and Guest Zone through 1.09 devices. Device passwords, such as the admin password and the WPA key, are stored in cleartext.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:21:41.195Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.nivel4.com/investigaciones/nuevas-vulnerabilidades-en-router-d-link-permiten-tomar-control-remoto-del-dispositivo/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on D-Link DIR-809 A1 through 1.09, A2 through 1.11, and Guest Zone through 1.09 devices. Device passwords, such as the admin password and the WPA key, are stored in cleartext."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-09T14:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://blog.nivel4.com/investigaciones/nuevas-vulnerabilidades-en-router-d-link-permiten-tomar-control-remoto-del-dispositivo/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-14081",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on D-Link DIR-809 A1 through 1.09, A2 through 1.11, and Guest Zone through 1.09 devices. Device passwords, such as the admin password and the WPA key, are stored in cleartext."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://blog.nivel4.com/investigaciones/nuevas-vulnerabilidades-en-router-d-link-permiten-tomar-control-remoto-del-dispositivo/",
              "refsource": "MISC",
              "url": "https://blog.nivel4.com/investigaciones/nuevas-vulnerabilidades-en-router-d-link-permiten-tomar-control-remoto-del-dispositivo/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-14081",
    "datePublished": "2018-10-09T15:00:00",
    "dateReserved": "2018-07-15T00:00:00",
    "dateUpdated": "2024-08-05T09:21:41.195Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-33271 (GCVE-0-2021-33271)
Vulnerability from cvelistv5
Published
2021-12-01 21:20
Modified
2024-08-03 23:42
Severity ?
CWE
  • n/a
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function sub_80046EB4 in /formSetPortTr. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:42:20.417Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dlink.com/en/security-bulletin/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln11"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function sub_80046EB4 in /formSetPortTr. This vulnerability is triggered via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-01T21:20:52",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dlink.com/en/security-bulletin/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln11"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-33271",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function sub_80046EB4 in /formSetPortTr. This vulnerability is triggered via a crafted POST request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dlink.com/en/security-bulletin/",
              "refsource": "MISC",
              "url": "https://www.dlink.com/en/security-bulletin/"
            },
            {
              "name": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln11",
              "refsource": "MISC",
              "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln11"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-33271",
    "datePublished": "2021-12-01T21:20:52",
    "dateReserved": "2021-05-20T00:00:00",
    "dateUpdated": "2024-08-03T23:42:20.417Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-33266 (GCVE-0-2021-33266)
Vulnerability from cvelistv5
Published
2021-12-01 21:20
Modified
2024-08-03 23:42
Severity ?
CWE
  • n/a
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_8004776c in /formVirtualApp. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:42:20.318Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dlink.com/en/security-bulletin/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_8004776c in /formVirtualApp. This vulnerability is triggered via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-01T21:20:55",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dlink.com/en/security-bulletin/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln04"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-33266",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_8004776c in /formVirtualApp. This vulnerability is triggered via a crafted POST request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dlink.com/en/security-bulletin/",
              "refsource": "MISC",
              "url": "https://www.dlink.com/en/security-bulletin/"
            },
            {
              "name": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln04",
              "refsource": "MISC",
              "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln04"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-33266",
    "datePublished": "2021-12-01T21:20:55",
    "dateReserved": "2021-05-20T00:00:00",
    "dateUpdated": "2024-08-03T23:42:20.318Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-33268 (GCVE-0-2021-33268)
Vulnerability from cvelistv5
Published
2021-12-01 21:20
Modified
2024-08-03 23:42
Severity ?
CWE
  • n/a
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function sub_8003183C in /fromLogin. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:42:20.363Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dlink.com/en/security-bulletin/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function sub_8003183C in /fromLogin. This vulnerability is triggered via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-01T21:20:54",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dlink.com/en/security-bulletin/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-33268",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function sub_8003183C in /fromLogin. This vulnerability is triggered via a crafted POST request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dlink.com/en/security-bulletin/",
              "refsource": "MISC",
              "url": "https://www.dlink.com/en/security-bulletin/"
            },
            {
              "name": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln03",
              "refsource": "MISC",
              "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-33268",
    "datePublished": "2021-12-01T21:20:54",
    "dateReserved": "2021-05-20T00:00:00",
    "dateUpdated": "2024-08-03T23:42:20.363Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-33274 (GCVE-0-2021-33274)
Vulnerability from cvelistv5
Published
2021-12-01 21:20
Modified
2024-08-03 23:42
Severity ?
CWE
  • n/a
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80040af8 in /formWlanSetup. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:42:20.269Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dlink.com/en/security-bulletin/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln07"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80040af8 in /formWlanSetup. This vulnerability is triggered via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-01T21:20:51",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dlink.com/en/security-bulletin/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln07"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-33274",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80040af8 in /formWlanSetup. This vulnerability is triggered via a crafted POST request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dlink.com/en/security-bulletin/",
              "refsource": "MISC",
              "url": "https://www.dlink.com/en/security-bulletin/"
            },
            {
              "name": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln07",
              "refsource": "MISC",
              "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln07"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-33274",
    "datePublished": "2021-12-01T21:20:51",
    "dateReserved": "2021-05-20T00:00:00",
    "dateUpdated": "2024-08-03T23:42:20.269Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-8361 (GCVE-0-2014-8361)
Vulnerability from cvelistv5
Published
2015-05-01 00:00
Modified
2025-07-30 01:46
Severity ?
CWE
  • n/a
Summary
The miniigd SOAP service in Realtek SDK allows remote attackers to execute arbitrary code via a crafted NewInternalClient request, as exploited in the wild through 2023.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:18:47.756Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-155/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://securityadvisories.dlink.com/security/publication.aspx?name=SAP10055"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/132090/Realtek-SDK-Miniigd-UPnP-SOAP-Command-Execution.html"
          },
          {
            "name": "74330",
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/74330"
          },
          {
            "name": "37169",
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/37169/"
          },
          {
            "name": "JVN#47580234",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "http://jvn.jp/en/jp/JVN47580234/index.html"
          },
          {
            "name": "JVN#67456944",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "http://jvn.jp/en/jp/JVN67456944/index.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://sensorstechforum.com/hinatabot-cve-2014-8361-ddos/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://web.archive.org/web/20150909230440/http://securityadvisories.dlink.com/security/publication.aspx?name=SAP10055"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2014-8361",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-07T21:57:55.692724Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2023-09-18",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2014-8361"
              },
              "type": "kev"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "description": "CWE-noinfo Not enough information",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-30T01:46:45.224Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "timeline": [
          {
            "lang": "en",
            "time": "2023-09-18T00:00:00+00:00",
            "value": "CVE-2014-8361 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-04-30T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The miniigd SOAP service in Realtek SDK allows remote attackers to execute arbitrary code via a crafted NewInternalClient request, as exploited in the wild through 2023."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-05T21:35:13.232Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "http://www.zerodayinitiative.com/advisories/ZDI-15-155/"
        },
        {
          "url": "http://securityadvisories.dlink.com/security/publication.aspx?name=SAP10055"
        },
        {
          "url": "http://packetstormsecurity.com/files/132090/Realtek-SDK-Miniigd-UPnP-SOAP-Command-Execution.html"
        },
        {
          "name": "74330",
          "tags": [
            "vdb-entry"
          ],
          "url": "http://www.securityfocus.com/bid/74330"
        },
        {
          "name": "37169",
          "tags": [
            "exploit"
          ],
          "url": "https://www.exploit-db.com/exploits/37169/"
        },
        {
          "name": "JVN#47580234",
          "tags": [
            "third-party-advisory"
          ],
          "url": "http://jvn.jp/en/jp/JVN47580234/index.html"
        },
        {
          "name": "JVN#67456944",
          "tags": [
            "third-party-advisory"
          ],
          "url": "http://jvn.jp/en/jp/JVN67456944/index.html"
        },
        {
          "url": "https://sensorstechforum.com/hinatabot-cve-2014-8361-ddos/"
        },
        {
          "url": "https://web.archive.org/web/20150909230440/http://securityadvisories.dlink.com/security/publication.aspx?name=SAP10055"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-8361",
    "datePublished": "2015-05-01T00:00:00.000Z",
    "dateReserved": "2014-10-20T00:00:00.000Z",
    "dateUpdated": "2025-07-30T01:46:45.224Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-33269 (GCVE-0-2021-33269)
Vulnerability from cvelistv5
Published
2021-12-01 21:20
Modified
2024-08-03 23:42
Severity ?
CWE
  • n/a
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_8004776c in /formVirtualServ. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:42:20.286Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dlink.com/en/security-bulletin/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_8004776c in /formVirtualServ. This vulnerability is triggered via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-01T21:20:53",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dlink.com/en/security-bulletin/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-33269",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_8004776c in /formVirtualServ. This vulnerability is triggered via a crafted POST request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dlink.com/en/security-bulletin/",
              "refsource": "MISC",
              "url": "https://www.dlink.com/en/security-bulletin/"
            },
            {
              "name": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln01",
              "refsource": "MISC",
              "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-33269",
    "datePublished": "2021-12-01T21:20:53",
    "dateReserved": "2021-05-20T00:00:00",
    "dateUpdated": "2024-08-03T23:42:20.286Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-33270 (GCVE-0-2021-33270)
Vulnerability from cvelistv5
Published
2021-12-01 21:20
Modified
2024-08-03 23:42
Severity ?
CWE
  • n/a
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_800462c4 in /formAdvFirewall. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:42:20.284Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dlink.com/en/security-bulletin/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln06"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_800462c4 in /formAdvFirewall. This vulnerability is triggered via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-01T21:20:52",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dlink.com/en/security-bulletin/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln06"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-33270",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_800462c4 in /formAdvFirewall. This vulnerability is triggered via a crafted POST request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dlink.com/en/security-bulletin/",
              "refsource": "MISC",
              "url": "https://www.dlink.com/en/security-bulletin/"
            },
            {
              "name": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln06",
              "refsource": "MISC",
              "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln06"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-33270",
    "datePublished": "2021-12-01T21:20:52",
    "dateReserved": "2021-05-20T00:00:00",
    "dateUpdated": "2024-08-03T23:42:20.284Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-33265 (GCVE-0-2021-33265)
Vulnerability from cvelistv5
Published
2021-12-01 21:20
Modified
2024-08-03 23:42
Severity ?
CWE
  • n/a
Summary
D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80046eb4 in /formSetPortTr. This vulnerability is triggered via a crafted POST request.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:42:20.299Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dlink.com/en/security-bulletin/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80046eb4 in /formSetPortTr. This vulnerability is triggered via a crafted POST request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-01T21:20:56",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dlink.com/en/security-bulletin/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln05"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-33265",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80046eb4 in /formSetPortTr. This vulnerability is triggered via a crafted POST request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dlink.com/en/security-bulletin/",
              "refsource": "MISC",
              "url": "https://www.dlink.com/en/security-bulletin/"
            },
            {
              "name": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln05",
              "refsource": "MISC",
              "url": "https://github.com/Lnkvct/IoT-poc/tree/master/D-Link-DIR809/vuln05"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-33265",
    "datePublished": "2021-12-01T21:20:56",
    "dateReserved": "2021-05-20T00:00:00",
    "dateUpdated": "2024-08-03T23:42:20.299Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-14080 (GCVE-0-2018-14080)
Vulnerability from cvelistv5
Published
2018-10-09 15:00
Modified
2024-08-05 09:21
Severity ?
CWE
  • n/a
Summary
An issue was discovered on D-Link DIR-809 A1 through 1.09, A2 through 1.11, and Guest Zone through 1.09 devices. One can bypass authentication mechanisms to download the configuration file.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T09:21:41.305Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.nivel4.com/investigaciones/nuevas-vulnerabilidades-en-router-d-link-permiten-tomar-control-remoto-del-dispositivo/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-10-01T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on D-Link DIR-809 A1 through 1.09, A2 through 1.11, and Guest Zone through 1.09 devices. One can bypass authentication mechanisms to download the configuration file."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-09T14:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://blog.nivel4.com/investigaciones/nuevas-vulnerabilidades-en-router-d-link-permiten-tomar-control-remoto-del-dispositivo/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-14080",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on D-Link DIR-809 A1 through 1.09, A2 through 1.11, and Guest Zone through 1.09 devices. One can bypass authentication mechanisms to download the configuration file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://blog.nivel4.com/investigaciones/nuevas-vulnerabilidades-en-router-d-link-permiten-tomar-control-remoto-del-dispositivo/",
              "refsource": "MISC",
              "url": "https://blog.nivel4.com/investigaciones/nuevas-vulnerabilidades-en-router-d-link-permiten-tomar-control-remoto-del-dispositivo/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-14080",
    "datePublished": "2018-10-09T15:00:00",
    "dateReserved": "2018-07-15T00:00:00",
    "dateUpdated": "2024-08-05T09:21:41.305Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}