Vulnerabilites related to bosch - divar_ip_7000_r2_firmware
Vulnerability from fkie_nvd
Published
2023-12-18 13:15
Modified
2024-11-21 08:08
Severity ?
5.9 (Medium) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H
5.9 (Medium) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H
5.9 (Medium) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
An improper handling of a malformed API answer packets to API clients in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation. To exploit this vulnerability an attacker has to replace an existing API server e.g. through Man-in-the-Middle attacks.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:building_integration_system_video_engine:*:*:*:*:*:*:*:*", "matchCriteriaId": "F28540F2-5651-4443-8B98-F3880609FDF4", "versionEndIncluding": "5.0.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:bosch_video_management_system:*:*:*:*:*:*:*:*", "matchCriteriaId": "E174ECD4-2F81-4F4D-81D5-2D6449E776C5", "versionEndIncluding": "12.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:video_management_system_viewer:*:*:*:*:*:*:*:*", "matchCriteriaId": "DEF983D4-76C3-4B0B-B5D4-38B382817827", "versionEndIncluding": "12.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:configuration_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "B63F7045-9EA4-4ACA-851C-DF1D6B444022", "versionEndIncluding": "7.62", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_7000_r2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CBE6F03E-7671-45D3-9C9F-19112D8422D2", "versionEndIncluding": "12.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_7000_r2:-:*:*:*:*:*:*:*", "matchCriteriaId": "7C27C0C9-7FC8-4B0C-BBF1-C7833CA9B2DE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_all-in-one_4000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E2F28D9-444C-4FE8-8129-57A65397380D", "versionEndIncluding": "12.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_all-in-one_4000:-:*:*:*:*:*:*:*", "matchCriteriaId": "058E1EC6-5D7E-4AA4-AC6F-B235753AF06F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_all-in-one_5000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D3475E4D-0F6A-4D7E-A667-F3B90F679535", "versionEndIncluding": "12.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_all-in-one_5000:-:*:*:*:*:*:*:*", "matchCriteriaId": "7075A014-A297-4E41-81D8-2535BC2BD4E9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_all-in-one_6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F70C23B-1262-458A-89DA-56C767D23E46", "versionEndIncluding": "12.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_all-in-one_6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "56136987-D034-4001-9D91-86205EA42C82", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_all-in-one_7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "40AE6FA0-24E1-4E16-BF04-FF267769C090", "versionEndIncluding": "12.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_all-in-one_7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "E531FC6E-B7AF-48DF-ACC2-91B5BD2B68DB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_all-in-one_7000_r3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1F993333-427F-4EA8-B509-63324D40C272", "versionEndIncluding": "12.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_all-in-one_7000_r3:-:*:*:*:*:*:*:*", "matchCriteriaId": "5AF06298-9397-4111-9660-637A7A4484FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:intelligent_insights:*:*:*:*:*:*:*:*", "matchCriteriaId": "DC6B338D-31A4-4192-936A-CD462112822F", "versionEndIncluding": "1.0.3.14", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:_onvif_camera_event_driver_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "8169AFEE-532B-4A40-B7E5-D1E8BDF29FF5", "versionEndIncluding": "2.0.0.8", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:project_assistant:*:*:*:*:*:*:*:*", "matchCriteriaId": "39DB5F35-7309-4B50-817B-6DD03AC64A91", "versionEndIncluding": "2.3", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:video_security_client:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C32C11F-D04D-4CE1-A8A4-68D5DF11F041", "versionEndIncluding": "3.3.5", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An improper handling of a malformed API answer packets to API clients in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation. To exploit this vulnerability an attacker has to replace an existing API server e.g. through Man-in-the-Middle attacks." }, { "lang": "es", "value": "Un manejo inadecuado de paquetes de respuesta API con formato incorrecto para clientes API en productos de software Bosch BT puede permitir que un atacante no autenticado provoque una situaci\u00f3n de denegaci\u00f3n de servicio (DoS). Para aprovechar esta vulnerabilidad, un atacante debe reemplazar un servidor API existente, por ejemplo mediante ataques Man-in-the-Middle." } ], "id": "CVE-2023-35867", "lastModified": "2024-11-21T08:08:51.793", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 3.6, "source": "psirt@bosch.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-12-18T13:15:07.010", "references": [ { "source": "psirt@bosch.com", "tags": [ "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html" } ], "sourceIdentifier": "psirt@bosch.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-703" } ], "source": "psirt@bosch.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-06-15 11:15
Modified
2024-11-21 07:54
Severity ?
7.1 (High) - CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:L/A:N
7.7 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N
7.7 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N
Summary
Improper Authorization in SSH server in Bosch VMS 11.0, 11.1.0, and 11.1.1 allows a remote authenticated user to access resources within the trusted internal network via a port forwarding request.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:bosch:video_management_system:*:*:*:*:*:*:*:*", "matchCriteriaId": "19576583-FEDD-4D73-AE62-863636F9CC3F", "versionEndIncluding": "11.1.1", "versionStartIncluding": "7.5", "vulnerable": true }, { "criteria": "cpe:2.3:a:bosch:video_management_system_viewer:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE49F10A-B283-4A83-B2D4-FC2EF44C9CC7", "versionEndIncluding": "11.1.1", "versionStartIncluding": "7.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_4000:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF7AC49B-19B5-474A-B2AD-8801440663B2", "vulnerable": false }, { "criteria": "cpe:2.3:h:bosch:divar_ip_5000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AB0DE1C9-D3C0-49BF-9FFD-B765F9AF6691", "vulnerable": false }, { "criteria": "cpe:2.3:h:bosch:divar_ip_6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "790EF36F-6C6B-477E-A2B8-369E6D113004", "vulnerable": false }, { "criteria": "cpe:2.3:h:bosch:divar_ip_7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "10D23E90-110B-4ADC-8417-CD0149D126D2", "vulnerable": false }, { "criteria": "cpe:2.3:h:bosch:divar_ip_7000_r2:-:*:*:*:*:*:*:*", "matchCriteriaId": "7C27C0C9-7FC8-4B0C-BBF1-C7833CA9B2DE", "vulnerable": false }, { "criteria": "cpe:2.3:h:bosch:divar_ip_7000_r3:-:*:*:*:*:*:*:*", "matchCriteriaId": "C021F78B-FBA2-4C35-8B26-FF0E3D4B9907", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_3000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "167DFF9C-69C3-4C70-B8A7-992D8D2AAD95", "versionEndIncluding": "8.0", "versionStartIncluding": "7.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_3000:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EE760B-9B65-49A3-92E5-93880C58A628", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_6000_firmware:11.1.1:*:*:*:*:*:*:*", "matchCriteriaId": "D313D23C-C0A8-4F36-93F5-9CF39EF6463F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "790EF36F-6C6B-477E-A2B8-369E6D113004", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_4000_firmware:11.1.1:*:*:*:*:*:*:*", "matchCriteriaId": "92342086-0830-4ABE-A3CF-91255FB7D0B6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_4000:-:*:*:*:*:*:*:*", "matchCriteriaId": "CF7AC49B-19B5-474A-B2AD-8801440663B2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_5000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A981D11-E964-412C-A333-96BB930758CC", "versionEndIncluding": "11.1.1", "versionStartIncluding": "9.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_5000:-:*:*:*:*:*:*:*", "matchCriteriaId": "AB0DE1C9-D3C0-49BF-9FFD-B765F9AF6691", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_7000_r2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1622C8F-3DD5-4112-BE15-C8873EDFA67E", "versionEndIncluding": "11.1.1", "versionStartIncluding": "7.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_7000_r2:-:*:*:*:*:*:*:*", "matchCriteriaId": "7C27C0C9-7FC8-4B0C-BBF1-C7833CA9B2DE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "69B16286-EF3B-4A4A-AB48-4149CFE6C862", "versionEndIncluding": "8.0", "versionStartIncluding": "7.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "10D23E90-110B-4ADC-8417-CD0149D126D2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:divar_ip_7000_r3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9BCD391-4552-4375-BCE7-0EF1BD81A03E", "versionEndIncluding": "11.1.1", "versionStartIncluding": "10.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:divar_ip_7000_r3:-:*:*:*:*:*:*:*", "matchCriteriaId": "C021F78B-FBA2-4C35-8B26-FF0E3D4B9907", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper Authorization in SSH server in Bosch VMS 11.0, 11.1.0, and 11.1.1 allows a remote authenticated user to access resources within the trusted internal network via a port forwarding request." } ], "id": "CVE-2023-28175", "lastModified": "2024-11-21T07:54:32.270", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 4.7, "source": "psirt@bosch.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.7, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.1, "impactScore": 4.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-06-15T11:15:09.227", "references": [ { "source": "psirt@bosch.com", "tags": [ "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html" } ], "sourceIdentifier": "psirt@bosch.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "psirt@bosch.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-863" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2023-35867 (GCVE-0-2023-35867)
Vulnerability from cvelistv5
Published
2023-12-18 12:59
Modified
2024-08-02 16:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-703 - Improper Check or Handling of Exceptional Conditions
Summary
An improper handling of a malformed API answer packets to API clients in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation. To exploit this vulnerability an attacker has to replace an existing API server e.g. through Man-in-the-Middle attacks.
References
► | URL | Tags |
---|---|---|
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Bosch | BVMS |
Version: 0 < |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T16:30:45.391Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "BVMS", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "12.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "BVMS Viewer", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "12.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "Configuration Manager", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "7.62", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "DIVAR IP 7000 R2", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "12.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "DIVAR IP all-in-one 5000", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "12.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "DIVAR IP all-in-one 7000", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "12.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "DIVAR IP all-in-one 7000 R3", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "12.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "DIVAR IP all-in-one 4000", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "12.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "DIVAR IP all-in-one 6000", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "12.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "Project Assistant", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "Video Security Client", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "3.3.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "BIS Video Engine", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "5.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "Intelligent Insights", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "1.0.3.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "product": "ONVIF Camera Event Driver Tool", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "2.0.0.8", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "An improper handling of a malformed API answer packets to API clients in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation. To exploit this vulnerability an attacker has to replace an existing API server e.g. through Man-in-the-Middle attacks." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-703", "description": "CWE-703 Improper Check or Handling of Exceptional Conditions", "lang": "en-US" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-18T12:59:48.604Z", "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c", "shortName": "bosch" }, "references": [ { "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html", "tags": [ "vendor-advisory" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html" } ] } }, "cveMetadata": { "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c", "assignerShortName": "bosch", "cveId": "CVE-2023-35867", "datePublished": "2023-12-18T12:59:48.604Z", "dateReserved": "2023-06-19T09:15:32.387Z", "dateUpdated": "2024-08-02T16:30:45.391Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-28175 (GCVE-0-2023-28175)
Vulnerability from cvelistv5
Published
2023-06-15 10:14
Modified
2024-12-17 20:51
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Summary
Improper Authorization in SSH server in Bosch VMS 11.0, 11.1.0, and 11.1.1 allows a remote authenticated user to access resources within the trusted internal network via a port forwarding request.
References
► | URL | Tags |
---|---|---|
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Bosch | BVMS |
Version: 7.5 < |
||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:30:24.180Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-28175", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-12-17T20:49:39.796592Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-12-17T20:51:14.639Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "BVMS", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "11.1.1", "status": "affected", "version": "7.5", "versionType": "custom" } ] }, { "product": "BVMS Viewer", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "11.1.1", "status": "affected", "version": "7.5", "versionType": "custom" } ] }, { "product": "Bosch DIVAR IP 3000", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "8.0", "status": "affected", "version": "7.5", "versionType": "custom" } ] }, { "product": "Bosch DIVAR IP 7000 R1", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "8.0", "status": "affected", "version": "7.5", "versionType": "custom" } ] }, { "product": "Bosch DIVAR IP 7000 R2", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "11.1.1", "status": "affected", "version": "7.5", "versionType": "custom" } ] }, { "product": "Bosch DIVAR IP all-in-one 7000 R3", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "11.1.1", "status": "affected", "version": "10.1.1", "versionType": "custom" } ] }, { "product": "Bosch DIVAR IP all-in-one 5000", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "11.1.1", "status": "affected", "version": "9.0", "versionType": "custom" } ] }, { "product": "Bosch DIVAR IP all-in-one 7000", "vendor": "Bosch", "versions": [ { "lessThanOrEqual": "11.1.1", "status": "affected", "version": "9.0", "versionType": "custom" } ] }, { "product": "DIVAR IP all-in-one 4000", "vendor": "Bosch", "versions": [ { "status": "affected", "version": "11.1.1" } ] }, { "product": "DIVAR IP all-in-one 6000", "vendor": "Bosch", "versions": [ { "status": "affected", "version": "11.1.1" } ] } ], "descriptions": [ { "lang": "en", "value": "Improper Authorization in SSH server in Bosch VMS 11.0, 11.1.0, and 11.1.1 allows a remote authenticated user to access resources within the trusted internal network via a port forwarding request." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:L/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor", "lang": "en-US" } ] } ], "providerMetadata": { "dateUpdated": "2023-06-15T10:14:34.076Z", "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c", "shortName": "bosch" }, "references": [ { "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html", "tags": [ "vendor-advisory" ], "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html" } ] } }, "cveMetadata": { "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c", "assignerShortName": "bosch", "cveId": "CVE-2023-28175", "datePublished": "2023-06-15T10:14:34.076Z", "dateReserved": "2023-03-13T15:46:37.814Z", "dateUpdated": "2024-12-17T20:51:14.639Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }