Vulnerabilites related to ui - es-16-xg
CVE-2019-5445 (GCVE-0-2019-5445)
Vulnerability from cvelistv5
Published
2019-07-10 19:45
Modified
2024-08-04 19:54
Severity ?
CWE
Summary
DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands.
Impacted products
Vendor Product Version
n/a EdgeMAX Version: 1.8.1
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:54:53.583Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EdgeMAX",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "1.8.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "Denial of Service (CWE-400)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-07-10T19:45:09",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "support@hackerone.com",
          "ID": "CVE-2019-5445",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EdgeMAX",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.8.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Denial of Service (CWE-400)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7",
              "refsource": "MISC",
              "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2019-5445",
    "datePublished": "2019-07-10T19:45:09",
    "dateReserved": "2019-01-04T00:00:00",
    "dateUpdated": "2024-08-04T19:54:53.583Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-8234 (GCVE-0-2020-8234)
Vulnerability from cvelistv5
Published
2020-08-21 20:37
Modified
2024-08-04 09:56
Severity ?
CWE
  • CWE-613 - Insufficient Session Expiration ()
Summary
A vulnerability exists in The EdgeMax EdgeSwitch firmware <v1.9.1 where the EdgeSwitch legacy web interface SIDSSL cookie for admin can be guessed, enabling the attacker to obtain high privileges and get a root shell by a Command injection.
Impacted products
Vendor Product Version
n/a EdgeSwitch firmware v1.9.0 and prior Version: Fixed in EdgeMarx Edge Switch firmware v1.9.1
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:56:27.524Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.ui.com/download/edgemax"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821%2C"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c%2C"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EdgeSwitch firmware v1.9.0 and prior",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Fixed in EdgeMarx Edge Switch firmware v1.9.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability exists in The EdgeMax EdgeSwitch firmware \u003cv1.9.1 where the EdgeSwitch legacy web interface SIDSSL cookie for admin can be guessed, enabling the attacker to obtain high privileges and get a root shell by a Command injection."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-613",
              "description": "Insufficient Session Expiration (CWE-613)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-08-21T20:37:22",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.ui.com/download/edgemax"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821%2C"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c%2C"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "support@hackerone.com",
          "ID": "CVE-2020-8234",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EdgeSwitch firmware v1.9.0 and prior",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Fixed in EdgeMarx Edge Switch firmware v1.9.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability exists in The EdgeMax EdgeSwitch firmware \u003cv1.9.1 where the EdgeSwitch legacy web interface SIDSSL cookie for admin can be guessed, enabling the attacker to obtain high privileges and get a root shell by a Command injection."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Insufficient Session Expiration (CWE-613)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.ui.com/download/edgemax",
              "refsource": "MISC",
              "url": "https://www.ui.com/download/edgemax"
            },
            {
              "name": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821,",
              "refsource": "MISC",
              "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821,"
            },
            {
              "name": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c,",
              "refsource": "MISC",
              "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c,"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2020-8234",
    "datePublished": "2020-08-21T20:37:22",
    "dateReserved": "2020-01-28T00:00:00",
    "dateUpdated": "2024-08-04T09:56:27.524Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-5446 (GCVE-0-2019-5446)
Vulnerability from cvelistv5
Published
2019-07-10 19:47
Modified
2024-08-04 19:54
Severity ?
CWE
  • CWE-77 - Command Injection - Generic ()
Summary
Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root.
Impacted products
Vendor Product Version
n/a EdgeMAX Version: 1.8.1
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:54:53.484Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EdgeMAX",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "1.8.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection - Generic (CWE-77)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-07-10T19:47:07",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "support@hackerone.com",
          "ID": "CVE-2019-5446",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EdgeMAX",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.8.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Command Injection - Generic (CWE-77)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7",
              "refsource": "MISC",
              "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2019-5446",
    "datePublished": "2019-07-10T19:47:07",
    "dateReserved": "2019-01-04T00:00:00",
    "dateUpdated": "2024-08-04T19:54:53.484Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2020-08-21 21:15
Modified
2024-11-21 05:38
Severity ?
Summary
A vulnerability exists in The EdgeMax EdgeSwitch firmware <v1.9.1 where the EdgeSwitch legacy web interface SIDSSL cookie for admin can be guessed, enabling the attacker to obtain high privileges and get a root shell by a Command injection.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ui:edgemax_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9A1458F-C99F-4F7F-8D07-151492B0AED6",
              "versionEndExcluding": "1.9.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ui:ep-s16:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D52DC6E-7DEA-47B0-9202-0EDEF033D09D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:o:ui:es-12f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16EDA969-F46D-4D35-8502-0BF23FF843BA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:o:ui:es-16-150w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB3291E6-3349-4BC1-B4D9-D14D5B4F2CC2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:o:ui:es-16-xg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DC80F08E-FE2C-4D6F-8861-410A8CB488C9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:o:ui:es-24-250w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "15658C2B-DDDB-4E63-AB3B-95E1244A2985",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:o:ui:es-24-500w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F13AA35A-5F54-4332-9F5E-7216931C1FF3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:o:ui:es-24-lite:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C61D8B37-AAAA-40B3-BFDB-0D0BC476E5CB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:o:ui:es-48-500w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50F1E43E-30CF-4CAF-B6F2-E0743588865E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:o:ui:es-48-750w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00789E82-2933-4A83-95F7-D2CBCCBF4E17",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:o:ui:es-48-lite:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC3D3131-90F7-4035-88BE-D4090C5D12AB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:o:ui:es-8-150w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A8CD2F2-92BA-4AE9-9D1B-CF4063E417C0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability exists in The EdgeMax EdgeSwitch firmware \u003cv1.9.1 where the EdgeSwitch legacy web interface SIDSSL cookie for admin can be guessed, enabling the attacker to obtain high privileges and get a root shell by a Command injection."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad en The EdgeMax EdgeSwitch versiones de firmware anteriores a v1.9.1, donde puede ser adivinada la cookie SIDSSL de la interfaz web heredada de EdgeSwitch para el administrador, permitiendo al atacante obtener altos privilegios y obtener un shell root mediante una inyecci\u00f3n de Comando."
    }
  ],
  "id": "CVE-2020-8234",
  "lastModified": "2024-11-21T05:38:33.570",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-08-21T21:15:12.027",
  "references": [
    {
      "source": "support@hackerone.com",
      "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c%2C"
    },
    {
      "source": "support@hackerone.com",
      "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821%2C"
    },
    {
      "source": "support@hackerone.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.ui.com/download/edgemax"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-9-1-v1-9-1/8a87dfc5-70f5-4055-8d67-570db1f5695c%2C"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://community.ui.com/releases/Security-advisory-bulletin-014-014/1c32c056-2c64-4e60-ac23-ce7d8f387821%2C"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Product"
      ],
      "url": "https://www.ui.com/download/edgemax"
    }
  ],
  "sourceIdentifier": "support@hackerone.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-613"
        }
      ],
      "source": "support@hackerone.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-613"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-07-10 20:15
Modified
2024-11-21 04:44
Summary
Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ui:edgeswitch_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB6F9B35-509E-4380-A473-796E32BCA88B",
              "versionEndExcluding": "1.8.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ui:ep-s16.:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E496145-AC02-4EF5-8FE2-BF5593F89ABA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-12f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "35E11BF8-2295-4DC3-B463-DC305B2ED456",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-16-150w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD4B5024-6E26-4011-9392-26E304C0B00C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-16-xg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "82590A80-2DA6-4BA3-BAF9-DA6B9118C7E2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-24-250w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EBA2938D-8AF2-47D5-B881-AD27A999989D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-24-500w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CDFD81A-C3D6-4B54-97C6-718FEB23C57C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-24-lite:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0085DBEE-368A-400D-A2E7-AC090CCD6324",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-48-500w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7AC5ECE-A2E4-4AD8-B65D-4B5CFFF0A044",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-48-750w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "287F2ABB-2855-4938-A5F3-857744ABC4E6",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-48-lite:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8A7623-0F2F-49F3-81F4-515E29A907EF",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-8-150w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD0CDC1D-D5F7-437D-9544-95E8DBFBF1F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root."
    },
    {
      "lang": "es",
      "value": "Una Inyecci\u00f3n de Comandos en EdgeMAX EdgeSwitch versiones anteriores a 1.8.2, permite a un usuario administrador ejecutar comandos como root."
    }
  ],
  "id": "CVE-2019-5446",
  "lastModified": "2024-11-21T04:44:57.033",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-07-10T20:15:12.763",
  "references": [
    {
      "source": "support@hackerone.com",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
    }
  ],
  "sourceIdentifier": "support@hackerone.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "support@hackerone.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-07-10 20:15
Modified
2024-11-21 04:44
Summary
DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:ui:edgeswitch_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB6F9B35-509E-4380-A473-796E32BCA88B",
              "versionEndExcluding": "1.8.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:ui:ep-s16.:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E496145-AC02-4EF5-8FE2-BF5593F89ABA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-12f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "35E11BF8-2295-4DC3-B463-DC305B2ED456",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-16-150w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD4B5024-6E26-4011-9392-26E304C0B00C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-16-xg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "82590A80-2DA6-4BA3-BAF9-DA6B9118C7E2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-24-250w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EBA2938D-8AF2-47D5-B881-AD27A999989D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-24-500w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CDFD81A-C3D6-4B54-97C6-718FEB23C57C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-24-lite:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0085DBEE-368A-400D-A2E7-AC090CCD6324",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-48-500w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7AC5ECE-A2E4-4AD8-B65D-4B5CFFF0A044",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-48-750w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "287F2ABB-2855-4938-A5F3-857744ABC4E6",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-48-lite:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0C8A7623-0F2F-49F3-81F4-515E29A907EF",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:ui:es-8-150w:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD0CDC1D-D5F7-437D-9544-95E8DBFBF1F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "DoS in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to Crash the SSH CLI interface by using crafted commands."
    },
    {
      "lang": "es",
      "value": "Una DoS en EdgeMAX EdgeSwitch versiones anteriores a 1.8.2, permite que un usuario administrador Bloquee la interfaz de la CLI de SSH mediante el uso de comandos especialmente dise\u00f1ados."
    }
  ],
  "id": "CVE-2019-5445",
  "lastModified": "2024-11-21T04:44:56.923",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 4.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-07-10T20:15:12.687",
  "references": [
    {
      "source": "support@hackerone.com",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Vendor Advisory"
      ],
      "url": "https://community.ui.com/releases/EdgeMAX-EdgeSwitch-Firmware-v1-8-2/824d58b1-6027-49cf-878d-2076c01948b7"
    }
  ],
  "sourceIdentifier": "support@hackerone.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "support@hackerone.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}