Vulnerabilites related to arcinfo - frontvue
Vulnerability from fkie_nvd
Published
2012-04-03 03:44
Modified
2025-04-11 00:51
Severity ?
Summary
An unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to execute arbitrary code by using a crafted HTML document to obtain control of a function pointer.
Impacted products
Vendor Product Version
arcinfo frontvue *
arcinfo pcvue 6.0
arcinfo pcvue 8.2
arcinfo pcvue 9.0
arcinfo pcvue 10.0
arcinfo plantvue *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:arcinfo:frontvue:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B019234-D1AB-498E-A047-00BCC3615CF2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:6.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "AEA0A812-C7F7-4651-9290-EFB099D111C8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:8.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9CA6F24-A3D3-4FE7-80C9-625BE5DDFAC2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1719190-35E4-4056-AC19-ED8C3190BF6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:10.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "210BA70E-D58C-446C-8701-94089B844DB0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:plantvue:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "241F982C-C133-4685-8031-C17EBEECBE92",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to execute arbitrary code by using a crafted HTML document to obtain control of a function pointer."
    },
    {
      "lang": "es",
      "value": "Control ActiveX no determinado en SVUIGrd.ocx en ARC Informatique PcVue v6.0 hasta v10.0, FrontVue, y PlantVue permite a atacantes remotos ejecutar c\u00f3digo usando un documento HTML manipulado para obtener el control de un puntero a una funci\u00f3n."
    }
  ],
  "id": "CVE-2011-4042",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.3,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ]
  },
  "published": "2012-04-03T03:44:35.930",
  "references": [
    {
      "source": "cret@cert.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
    },
    {
      "source": "cret@cert.org",
      "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
    }
  ],
  "sourceIdentifier": "cret@cert.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2012-04-03 03:44
Modified
2025-04-11 00:51
Severity ?
Summary
Buffer overflow in an unspecified ActiveX control in aipgctl.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to cause a denial of service via a crafted HTML document.
Impacted products
Vendor Product Version
arcinfo frontvue -
arcinfo pcvue 6.0
arcinfo pcvue 8.2
arcinfo pcvue 9.0
arcinfo pcvue 10.0
arcinfo plantvue -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:arcinfo:frontvue:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B70D1F4-70EC-4AA9-8C9E-2D98A64443AF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:6.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "AEA0A812-C7F7-4651-9290-EFB099D111C8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:8.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9CA6F24-A3D3-4FE7-80C9-625BE5DDFAC2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1719190-35E4-4056-AC19-ED8C3190BF6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:10.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "210BA70E-D58C-446C-8701-94089B844DB0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:plantvue:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4005489C-7D69-40A1-9CAE-EB95251BE6D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Buffer overflow in an unspecified ActiveX control in aipgctl.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to cause a denial of service via a crafted HTML document."
    },
    {
      "lang": "es",
      "value": "Desbordamiento de b\u00fafer en un control ActiveX no determinado en aipgctl.ocx en ARC Informatique PcVue v6.0 hasta v10.0, FrontVue, y PlantVue, permite a atacantes remotos provocar una denegaci\u00f3n de servicio mediante un documento HTML manipulado."
    }
  ],
  "id": "CVE-2011-4045",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ]
  },
  "published": "2012-04-03T03:44:36.070",
  "references": [
    {
      "source": "cret@cert.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
    },
    {
      "source": "cret@cert.org",
      "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
    }
  ],
  "sourceIdentifier": "cret@cert.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2012-04-03 03:44
Modified
2025-04-11 00:51
Severity ?
Summary
Integer overflow in an unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to execute arbitrary code via a large value for an integer parameter, leading to a buffer overflow.
Impacted products
Vendor Product Version
arcinfo frontvue -
arcinfo pcvue 6.0
arcinfo pcvue 8.2
arcinfo pcvue 9.0
arcinfo pcvue 10.0
arcinfo plantvue -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:arcinfo:frontvue:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B70D1F4-70EC-4AA9-8C9E-2D98A64443AF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:6.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "AEA0A812-C7F7-4651-9290-EFB099D111C8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:8.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9CA6F24-A3D3-4FE7-80C9-625BE5DDFAC2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1719190-35E4-4056-AC19-ED8C3190BF6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:10.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "210BA70E-D58C-446C-8701-94089B844DB0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:plantvue:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4005489C-7D69-40A1-9CAE-EB95251BE6D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Integer overflow in an unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to execute arbitrary code via a large value for an integer parameter, leading to a buffer overflow."
    },
    {
      "lang": "es",
      "value": "Desbordamiento de entero en un control ActiveX no terminado en SVUIGrd.ocx en ARC Informatique PcVue v6.0 hasta v10.0, FrontVue, y PlantVue, permite a los atacantes remotos ejecutar c\u00f3digo a su elecci\u00f3n a trav\u00e9s de un valor muy grande en un par\u00e1metro entero, provocando un desbordamiento de b\u00fafer."
    }
  ],
  "id": "CVE-2011-4043",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.3,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ]
  },
  "published": "2012-04-03T03:44:35.977",
  "references": [
    {
      "source": "cret@cert.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
    },
    {
      "source": "cret@cert.org",
      "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
    }
  ],
  "sourceIdentifier": "cret@cert.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-189"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2012-04-03 03:44
Modified
2025-04-11 00:51
Severity ?
Summary
An unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to modify files via calls to unknown methods.
Impacted products
Vendor Product Version
arcinfo frontvue -
arcinfo pcvue 6.0
arcinfo pcvue 8.2
arcinfo pcvue 9.0
arcinfo pcvue 10.0
arcinfo plantvue -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:arcinfo:frontvue:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B70D1F4-70EC-4AA9-8C9E-2D98A64443AF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:6.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "AEA0A812-C7F7-4651-9290-EFB099D111C8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:8.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9CA6F24-A3D3-4FE7-80C9-625BE5DDFAC2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1719190-35E4-4056-AC19-ED8C3190BF6F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:pcvue:10.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "210BA70E-D58C-446C-8701-94089B844DB0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arcinfo:plantvue:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4005489C-7D69-40A1-9CAE-EB95251BE6D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to modify files via calls to unknown methods."
    },
    {
      "lang": "es",
      "value": "Control ActiveX no determinado en SVUIGrd.ocx en ARC Informatique PcVue v6.0 hasta v10.0, FrontVue, y PlantVue permite a atacantes remotos modificar ficheros a trav\u00e9s de llamadas a m\u00e9todos no determinados."
    }
  ],
  "id": "CVE-2011-4044",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ]
  },
  "published": "2012-04-03T03:44:36.023",
  "references": [
    {
      "source": "cret@cert.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
    },
    {
      "source": "cret@cert.org",
      "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
    }
  ],
  "sourceIdentifier": "cret@cert.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2011-4045 (GCVE-0-2011-4045)
Vulnerability from cvelistv5
Published
2012-04-03 01:00
Modified
2024-09-17 02:37
Severity ?
CWE
  • n/a
Summary
Buffer overflow in an unspecified ActiveX control in aipgctl.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to cause a denial of service via a crafted HTML document.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T23:53:32.605Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Buffer overflow in an unspecified ActiveX control in aipgctl.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to cause a denial of service via a crafted HTML document."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-04-03T01:00:00Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2011-4045",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Buffer overflow in an unspecified ActiveX control in aipgctl.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to cause a denial of service via a crafted HTML document."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
            },
            {
              "name": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257",
              "refsource": "CONFIRM",
              "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
            },
            {
              "name": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440",
              "refsource": "CONFIRM",
              "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2011-4045",
    "datePublished": "2012-04-03T01:00:00Z",
    "dateReserved": "2011-10-13T00:00:00Z",
    "dateUpdated": "2024-09-17T02:37:27.840Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2011-4043 (GCVE-0-2011-4043)
Vulnerability from cvelistv5
Published
2012-04-03 01:00
Modified
2024-09-16 20:06
Severity ?
CWE
  • n/a
Summary
Integer overflow in an unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to execute arbitrary code via a large value for an integer parameter, leading to a buffer overflow.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T23:53:32.649Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Integer overflow in an unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to execute arbitrary code via a large value for an integer parameter, leading to a buffer overflow."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-04-03T01:00:00Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2011-4043",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Integer overflow in an unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to execute arbitrary code via a large value for an integer parameter, leading to a buffer overflow."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
            },
            {
              "name": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257",
              "refsource": "CONFIRM",
              "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
            },
            {
              "name": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440",
              "refsource": "CONFIRM",
              "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2011-4043",
    "datePublished": "2012-04-03T01:00:00Z",
    "dateReserved": "2011-10-13T00:00:00Z",
    "dateUpdated": "2024-09-16T20:06:55.150Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2011-4042 (GCVE-0-2011-4042)
Vulnerability from cvelistv5
Published
2012-04-03 01:00
Modified
2024-09-16 23:36
Severity ?
CWE
  • n/a
Summary
An unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to execute arbitrary code by using a crafted HTML document to obtain control of a function pointer.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T23:53:32.609Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to execute arbitrary code by using a crafted HTML document to obtain control of a function pointer."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-04-03T01:00:00Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2011-4042",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to execute arbitrary code by using a crafted HTML document to obtain control of a function pointer."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
            },
            {
              "name": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257",
              "refsource": "CONFIRM",
              "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
            },
            {
              "name": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440",
              "refsource": "CONFIRM",
              "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2011-4042",
    "datePublished": "2012-04-03T01:00:00Z",
    "dateReserved": "2011-10-13T00:00:00Z",
    "dateUpdated": "2024-09-16T23:36:32.865Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2011-4044 (GCVE-0-2011-4044)
Vulnerability from cvelistv5
Published
2012-04-03 01:00
Modified
2024-09-17 00:01
Severity ?
CWE
  • n/a
Summary
An unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to modify files via calls to unknown methods.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T23:53:32.613Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to modify files via calls to unknown methods."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-04-03T01:00:00Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2011-4044",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An unspecified ActiveX control in SVUIGrd.ocx in ARC Informatique PcVue 6.0 through 10.0, FrontVue, and PlantVue allows remote attackers to modify files via calls to unknown methods."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-340-01.pdf"
            },
            {
              "name": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257",
              "refsource": "CONFIRM",
              "url": "http://www.pcvuesolutions.com/index.php?option=com_content\u0026view=article\u0026id=244\u0026Itemid=257"
            },
            {
              "name": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440",
              "refsource": "CONFIRM",
              "url": "https://support.pcvuescada.com/index.php?option=com_k2\u0026view=item\u0026id=512\u0026Itemid=440"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2011-4044",
    "datePublished": "2012-04-03T01:00:00Z",
    "dateReserved": "2011-10-13T00:00:00Z",
    "dateUpdated": "2024-09-17T00:01:11.566Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}