Vulnerabilites related to grandstream - gwn7610
CVE-2019-10658 (GCVE-0-2019-10658)
Vulnerability from cvelistv5
Published
2019-03-30 16:42
Modified
2024-08-04 22:32
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Grandstream GWN7610 before 1.0.8.18 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the filename in a /ubus/controller.icc.update_nds_webroot_from_tmp update_nds_webroot_from_tmp API call.
References
► | URL | Tags |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T22:32:00.693Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920\u0026dl=1" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/scarvell/grandstream_exploits" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Grandstream GWN7610 before 1.0.8.18 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the filename in a /ubus/controller.icc.update_nds_webroot_from_tmp update_nds_webroot_from_tmp API call." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-04-12T17:27:07", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920\u0026dl=1" }, { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/scarvell/grandstream_exploits" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-10658", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Grandstream GWN7610 before 1.0.8.18 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the filename in a /ubus/controller.icc.update_nds_webroot_from_tmp update_nds_webroot_from_tmp API call." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920\u0026dl=1", "refsource": "MISC", "url": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920\u0026dl=1" }, { "name": "https://github.com/scarvell/grandstream_exploits", "refsource": "MISC", "url": "https://github.com/scarvell/grandstream_exploits" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-10658", "datePublished": "2019-03-30T16:42:54", "dateReserved": "2019-03-30T00:00:00", "dateUpdated": "2024-08-04T22:32:00.693Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2019-10657 (GCVE-0-2019-10657)
Vulnerability from cvelistv5
Published
2019-03-30 16:42
Modified
2024-08-04 22:32
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Grandstream GWN7000 before 1.0.6.32 and GWN7610 before 1.0.8.18 devices allow remote authenticated users to discover passwords via a /ubus/uci.apply config request.
References
► | URL | Tags |
---|---|---|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T22:32:00.873Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920\u0026dl=1" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://github.com/scarvell/grandstream_exploits" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Grandstream GWN7000 before 1.0.6.32 and GWN7610 before 1.0.8.18 devices allow remote authenticated users to discover passwords via a /ubus/uci.apply config request." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-04-12T17:26:25", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920\u0026dl=1" }, { "tags": [ "x_refsource_MISC" ], "url": "https://github.com/scarvell/grandstream_exploits" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-10657", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Grandstream GWN7000 before 1.0.6.32 and GWN7610 before 1.0.8.18 devices allow remote authenticated users to discover passwords via a /ubus/uci.apply config request." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920\u0026dl=1", "refsource": "MISC", "url": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920\u0026dl=1" }, { "name": "https://github.com/scarvell/grandstream_exploits", "refsource": "MISC", "url": "https://github.com/scarvell/grandstream_exploits" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-10657", "datePublished": "2019-03-30T16:42:42", "dateReserved": "2019-03-30T00:00:00", "dateUpdated": "2024-08-04T22:32:00.873Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2019-03-30 17:29
Modified
2024-11-21 04:19
Severity ?
Summary
Grandstream GWN7610 before 1.0.8.18 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the filename in a /ubus/controller.icc.update_nds_webroot_from_tmp update_nds_webroot_from_tmp API call.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
grandstream | gwn7610_firmware | * | |
grandstream | gwn7610 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:grandstream:gwn7610_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "50F4C37E-EACE-4FE4-A5A7-DFC7089312B5", "versionEndExcluding": "1.0.8.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:grandstream:gwn7610:-:*:*:*:*:*:*:*", "matchCriteriaId": "290DB24B-0CD0-47DE-9501-66F22933F5AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Grandstream GWN7610 before 1.0.8.18 devices allow remote authenticated users to execute arbitrary code via shell metacharacters in the filename in a /ubus/controller.icc.update_nds_webroot_from_tmp update_nds_webroot_from_tmp API call." }, { "lang": "es", "value": "Los dispositivos Grandstream GWN7610, en versiones anteriores a la 1.0.8.18, permiten a los usuarios remotos ejecutar c\u00f3digo arbitrario mediante metacaracteres shell en el nombre de archivo en una llamada API en /ubus/controller.icc.update_nds_webroot_from_tmp update_nds_webroot_from_tmp." } ], "id": "CVE-2019-10658", "lastModified": "2024-11-21T04:19:41.580", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-03-30T17:29:00.527", "references": [ { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://github.com/scarvell/grandstream_exploits" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920\u0026dl=1" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://github.com/scarvell/grandstream_exploits" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920\u0026dl=1" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-03-30 17:29
Modified
2024-11-21 04:19
Severity ?
Summary
Grandstream GWN7000 before 1.0.6.32 and GWN7610 before 1.0.8.18 devices allow remote authenticated users to discover passwords via a /ubus/uci.apply config request.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
grandstream | gwn7610_firmware | * | |
grandstream | gwn7610 | - | |
grandstream | gwn7000_firmware | * | |
grandstream | gwn7000 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:grandstream:gwn7610_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "50F4C37E-EACE-4FE4-A5A7-DFC7089312B5", "versionEndExcluding": "1.0.8.18", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:grandstream:gwn7610:-:*:*:*:*:*:*:*", "matchCriteriaId": "290DB24B-0CD0-47DE-9501-66F22933F5AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:grandstream:gwn7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33C63F32-3EA3-4CF3-AD72-DF2083C8080B", "versionEndExcluding": "1.0.6.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:grandstream:gwn7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "E0139B06-8FDD-4A29-B378-B917EAAD84A0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Grandstream GWN7000 before 1.0.6.32 and GWN7610 before 1.0.8.18 devices allow remote authenticated users to discover passwords via a /ubus/uci.apply config request." }, { "lang": "es", "value": "Los dispositivos Grandstream GWN7000, en versiones anteriores a la 1.0.6.32, y Grandstream GWN7610, en versiones anteriores a la 1.0.8.18, permite a los usuarios remotos autenticados descubrir contrase\u00f1as mediante una petici\u00f3n de configuraci\u00f3n en /ubus/uci.apply." } ], "id": "CVE-2019-10657", "lastModified": "2024-11-21T04:19:41.440", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 4.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-03-30T17:29:00.480", "references": [ { "source": "cve@mitre.org", "tags": [ "Not Applicable" ], "url": "https://github.com/scarvell/grandstream_exploits" }, { "source": "cve@mitre.org", "tags": [ "Third Party Advisory" ], "url": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920\u0026dl=1" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Not Applicable" ], "url": "https://github.com/scarvell/grandstream_exploits" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://www.trustwave.com/en-us/resources/security-resources/security-advisories/?fid=23920\u0026dl=1" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-78" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }