Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called “CMA Connect”, to interact with the iC Module on behalf of the user. Every time a user submits a password to the CLI password prompt, the buffer containing their input is passed as the password parameter to the checkPassword function.
Impacted products
Vendor Product Version
garrett ic_module_cma 5.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:garrett:ic_module_cma:5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "784C02B2-BE54-4105-8386-8E620CF5A318",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called \u201cCMA Connect\u201d, to interact with the iC Module on behalf of the user. Every time a user submits a password to the CLI password prompt, the buffer containing their input is passed as the password parameter to the checkPassword function."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria en la forma en que es usada la funci\u00f3n CMA readfile de Garrett Metal Detectors iC Module CMA Versi\u00f3n 5.0, en varios lugares. El Garrett iC Module expone una CLI autenticada a trav\u00e9s del puerto TCP 6877. Esta interfaz es usada por un cliente GUI secundario, llamado \"CMA Connect\", para interactuar con el iC Module en nombre del usuario. Cada vez que un usuario env\u00eda una contrase\u00f1a a la solicitud de contrase\u00f1a de la CLI, el b\u00fafer que contiene su entrada es pasado como par\u00e1metro de contrase\u00f1a a la funci\u00f3n checkPassword"
    }
  ],
  "id": "CVE-2021-21906",
  "lastModified": "2024-11-21T05:49:13.130",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.5,
        "impactScore": 6.0,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-22T19:15:09.837",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1357"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1357"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "talos-cna@cisco.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-22 19:15
Modified
2024-11-21 05:49
Summary
A directory traversal vulnerability exists in the CMA CLI setenv command of Garrett Metal Detectors’ iC Module CMA Version 5.0. An attacker can provide malicious input to trigger this vulnerability
Impacted products
Vendor Product Version
garrett ic_module_cma 5.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:garrett:ic_module_cma:5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "784C02B2-BE54-4105-8386-8E620CF5A318",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A directory traversal vulnerability exists in the CMA CLI setenv command of Garrett Metal Detectors\u2019 iC Module CMA Version 5.0. An attacker can provide malicious input to trigger this vulnerability"
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de salto de directorio en el comando CMA CLI setenv de iC Module CMA de Garrett Metal Detectors versi\u00f3n 5.0. Un atacante puede proporcionar una entrada maliciosa para desencadenar esta vulnerabilidad"
    }
  ],
  "id": "CVE-2021-21904",
  "lastModified": "2024-11-21T05:49:12.917",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 2.3,
        "impactScore": 6.0,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-22T19:15:09.743",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1356"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1356"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "talos-cna@cisco.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-22 19:15
Modified
2024-11-21 05:49
Severity ?
Summary
A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors’ iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to strcpy. An attacker can send a malicious packet to trigger this vulnerability.
Impacted products
Vendor Product Version
garrett ic_module_cma 5.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:garrett:ic_module_cma:5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "784C02B2-BE54-4105-8386-8E620CF5A318",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors\u2019 iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to strcpy. An attacker can send a malicious packet to trigger this vulnerability."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria en la funci\u00f3n CMA check_udp_crc de Garrett Metal Detectors\u2019 iC Module CMA Versi\u00f3n 5.0. Un paquete especialmente dise\u00f1ado puede conllevar a un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria durante una llamada a strcpy. Un atacante puede enviar un paquete malicioso para desencadenar esta vulnerabilidad"
    }
  ],
  "id": "CVE-2021-21903",
  "lastModified": "2024-11-21T05:49:12.807",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-22T19:15:09.707",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1355"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1355"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "talos-cna@cisco.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-22 19:15
Modified
2024-11-21 05:49
Summary
A directory traversal vulnerability exists in the CMA CLI getenv command functionality of Garrett Metal Detectors’ iC Module CMA Version 5.0. A specially-crafted command line argument can lead to local file inclusion. An attacker can provide malicious input to trigger this vulnerability.
Impacted products
Vendor Product Version
garrett ic_module_cma 5.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:garrett:ic_module_cma:5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "784C02B2-BE54-4105-8386-8E620CF5A318",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A directory traversal vulnerability exists in the CMA CLI getenv command functionality of Garrett Metal Detectors\u2019 iC Module CMA Version 5.0. A specially-crafted command line argument can lead to local file inclusion. An attacker can provide malicious input to trigger this vulnerability."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de salto de directorio en la funcionalidad getenv command de CMA CLI de Garrett Metal Detectors\u2019 iC Module CMA versi\u00f3n 5.0. Un argumento de l\u00ednea de comandos especialmente dise\u00f1ado puede conllevar a una inclusi\u00f3n de archivos locales. Un atacante puede proporcionar una entrada maliciosa para desencadenar esta vulnerabilidad"
    }
  ],
  "id": "CVE-2021-21907",
  "lastModified": "2024-11-21T05:49:13.237",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 4.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 3.6,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-22T19:15:09.877",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1358"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1358"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "talos-cna@cisco.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-22 19:15
Modified
2024-11-21 05:49
Summary
An authentication bypass vulnerability exists in the CMA run_server_6877 functionality of Garrett Metal Detectors iC Module CMA Version 5.0. A properly-timed network connection can lead to authentication bypass via session hijacking. An attacker can send a sequence of requests to trigger this vulnerability.
Impacted products
Vendor Product Version
garrett ic_module_cma 5.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:garrett:ic_module_cma:5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "784C02B2-BE54-4105-8386-8E620CF5A318",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An authentication bypass vulnerability exists in the CMA run_server_6877 functionality of Garrett Metal Detectors iC Module CMA Version 5.0. A properly-timed network connection can lead to authentication bypass via session hijacking. An attacker can send a sequence of requests to trigger this vulnerability."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n en la funcionalidad CMA run_server_6877 de Garrett Metal Detectors iC Module CMA Versi\u00f3n 5.0. Una conexi\u00f3n de red debidamente programada puede conllevar a una omisi\u00f3n de autenticaci\u00f3n por medio de un secuestro de sesi\u00f3n. Un atacante puede enviar una secuencia de peticiones para desencadenar esta vulnerabilidad"
    }
  ],
  "id": "CVE-2021-21902",
  "lastModified": "2024-11-21T05:49:12.700",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.3,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 5.9,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-22T19:15:09.667",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1354"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1354"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-303"
        }
      ],
      "source": "talos-cna@cisco.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-22 19:15
Modified
2024-11-21 05:49
Summary
Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called “CMA Connect”, to interact with the iC Module on behalf of the user. After a client successfully authenticates, they can send plaintext commands to manipulate the device.
Impacted products
Vendor Product Version
garrett ic_module_cma 5.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:garrett:ic_module_cma:5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "784C02B2-BE54-4105-8386-8E620CF5A318",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called \u201cCMA Connect\u201d, to interact with the iC Module on behalf of the user. After a client successfully authenticates, they can send plaintext commands to manipulate the device."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria se presenta en la forma en que es usada la funci\u00f3n CMA readfile de Garrett Metal Detectors iC Module Versi\u00f3n 5.0, en varios lugares. El Garrett iC Module expone una CLI autenticada a trav\u00e9s del puerto TCP 6877. Esta interfaz es usada por un cliente GUI secundario, llamado \"CMA Connect\", para interactuar con el iC Module en nombre del usuario. Despu\u00e9s de que un cliente sea autenticado con \u00e9xito, puede enviar comandos de texto plano para manipular el dispositivo"
    }
  ],
  "id": "CVE-2021-21905",
  "lastModified": "2024-11-21T05:49:13.023",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 8.5,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:M/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.5,
        "impactScore": 6.0,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-22T19:15:09.797",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1357"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1357"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "talos-cna@cisco.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-12-22 19:15
Modified
2024-11-21 05:49
Summary
A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors’ iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to memcpy. An attacker can send a malicious packet to trigger this vulnerability.
Impacted products
Vendor Product Version
garrett ic_module_cma 5.0



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:garrett:ic_module_cma:5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "784C02B2-BE54-4105-8386-8E620CF5A318",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors\u2019 iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to memcpy. An attacker can send a malicious packet to trigger this vulnerability."
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria en la funci\u00f3n CMA check_udp_crc de iC Module CMA de Garrett Metal Detectors versi\u00f3n 5.0. Un paquete especialmente dise\u00f1ado puede conllevar a un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria durante una llamada a memcpy. Un atacante puede enviar un paquete malicioso para desencadenar esta vulnerabilidad"
    }
  ],
  "id": "CVE-2021-21901",
  "lastModified": "2024-11-21T05:49:12.597",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-22T19:15:09.630",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1353"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1353"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "talos-cna@cisco.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2021-21906 (GCVE-0-2021-21906)
Vulnerability from cvelistv5
Published
2021-12-22 18:06
Modified
2024-08-03 18:30
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called “CMA Connect”, to interact with the iC Module on behalf of the user. Every time a user submits a password to the CLI password prompt, the buffer containing their input is passed as the password parameter to the checkPassword function.
Impacted products
Vendor Product Version
n/a Garrett Metal Detectors Version: Garrett Metal Detectors iC Module CMA Version 5.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:30:22.875Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1357"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Garrett Metal Detectors",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Garrett Metal Detectors iC Module CMA Version 5.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called \u201cCMA Connect\u201d, to interact with the iC Module on behalf of the user. Every time a user submits a password to the CLI password prompt, the buffer containing their input is passed as the password parameter to the checkPassword function."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-22T18:06:48",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1357"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2021-21906",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Garrett Metal Detectors",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Garrett Metal Detectors iC Module CMA Version 5.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called \u201cCMA Connect\u201d, to interact with the iC Module on behalf of the user. Every time a user submits a password to the CLI password prompt, the buffer containing their input is passed as the password parameter to the checkPassword function."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 8.2,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121: Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1357",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1357"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2021-21906",
    "datePublished": "2021-12-22T18:06:48",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-08-03T18:30:22.875Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21901 (GCVE-0-2021-21901)
Vulnerability from cvelistv5
Published
2021-12-22 18:06
Modified
2024-08-03 18:30
Severity ?
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Summary
A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors’ iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to memcpy. An attacker can send a malicious packet to trigger this vulnerability.
Impacted products
Vendor Product Version
n/a Garrett Metal Detectors Version: Garrett Metal Detectors iC Module CMA Version 5.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:30:22.888Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1353"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Garrett Metal Detectors",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Garrett Metal Detectors iC Module CMA Version 5.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors\u2019 iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to memcpy. An attacker can send a malicious packet to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-22T18:06:43",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1353"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2021-21901",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Garrett Metal Detectors",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Garrett Metal Detectors iC Module CMA Version 5.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors\u2019 iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to memcpy. An attacker can send a malicious packet to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1353",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1353"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2021-21901",
    "datePublished": "2021-12-22T18:06:43",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-08-03T18:30:22.888Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21902 (GCVE-0-2021-21902)
Vulnerability from cvelistv5
Published
2021-12-22 18:06
Modified
2024-08-03 18:30
CWE
  • CWE-303 - Incorrect Implementation of Authentication Algorithm
Summary
An authentication bypass vulnerability exists in the CMA run_server_6877 functionality of Garrett Metal Detectors iC Module CMA Version 5.0. A properly-timed network connection can lead to authentication bypass via session hijacking. An attacker can send a sequence of requests to trigger this vulnerability.
Impacted products
Vendor Product Version
n/a Garrett Metal Detectors Version: Garrett Metal Detectors iC Module CMA Version 5.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:30:22.862Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1354"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Garrett Metal Detectors",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Garrett Metal Detectors iC Module CMA Version 5.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An authentication bypass vulnerability exists in the CMA run_server_6877 functionality of Garrett Metal Detectors iC Module CMA Version 5.0. A properly-timed network connection can lead to authentication bypass via session hijacking. An attacker can send a sequence of requests to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-303",
              "description": "CWE-303: Incorrect Implementation of Authentication Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-22T18:06:44",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1354"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2021-21902",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Garrett Metal Detectors",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Garrett Metal Detectors iC Module CMA Version 5.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An authentication bypass vulnerability exists in the CMA run_server_6877 functionality of Garrett Metal Detectors iC Module CMA Version 5.0. A properly-timed network connection can lead to authentication bypass via session hijacking. An attacker can send a sequence of requests to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.5,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-303: Incorrect Implementation of Authentication Algorithm"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1354",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1354"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2021-21902",
    "datePublished": "2021-12-22T18:06:44",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-08-03T18:30:22.862Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21904 (GCVE-0-2021-21904)
Vulnerability from cvelistv5
Published
2021-12-22 18:06
Modified
2024-08-03 18:30
Severity ?
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
A directory traversal vulnerability exists in the CMA CLI setenv command of Garrett Metal Detectors’ iC Module CMA Version 5.0. An attacker can provide malicious input to trigger this vulnerability
Impacted products
Vendor Product Version
n/a Garrett Metal Detectors Version: Garrett Metal Detectors iC Module CMA Version 5.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:30:23.143Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1356"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Garrett Metal Detectors",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Garrett Metal Detectors iC Module CMA Version 5.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A directory traversal vulnerability exists in the CMA CLI setenv command of Garrett Metal Detectors\u2019 iC Module CMA Version 5.0. An attacker can provide malicious input to trigger this vulnerability"
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-22T18:06:46",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1356"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2021-21904",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Garrett Metal Detectors",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Garrett Metal Detectors iC Module CMA Version 5.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A directory traversal vulnerability exists in the CMA CLI setenv command of Garrett Metal Detectors\u2019 iC Module CMA Version 5.0. An attacker can provide malicious input to trigger this vulnerability"
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 9.1,
            "baseSeverity": "Critical",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1356",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1356"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2021-21904",
    "datePublished": "2021-12-22T18:06:46",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-08-03T18:30:23.143Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21905 (GCVE-0-2021-21905)
Vulnerability from cvelistv5
Published
2021-12-22 18:06
Modified
2024-08-03 18:30
CWE
  • CWE-121 - Stack-based Buffer Overflow
Summary
Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called “CMA Connect”, to interact with the iC Module on behalf of the user. After a client successfully authenticates, they can send plaintext commands to manipulate the device.
Impacted products
Vendor Product Version
n/a Garrett Metal Detectors Version: Garrett Metal Detectors iC Module CMA Version 5.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:30:23.083Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1357"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Garrett Metal Detectors",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Garrett Metal Detectors iC Module CMA Version 5.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called \u201cCMA Connect\u201d, to interact with the iC Module on behalf of the user. After a client successfully authenticates, they can send plaintext commands to manipulate the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-22T18:06:47",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1357"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2021-21905",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Garrett Metal Detectors",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Garrett Metal Detectors iC Module CMA Version 5.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based buffer overflow vulnerability exists in how the CMA readfile function of Garrett Metal Detectors iC Module CMA Version 5.0 is used at various locations. The Garrett iC Module exposes an authenticated CLI over TCP port 6877. This interface is used by a secondary GUI client, called \u201cCMA Connect\u201d, to interact with the iC Module on behalf of the user. After a client successfully authenticates, they can send plaintext commands to manipulate the device."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 8.2,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121: Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1357",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1357"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2021-21905",
    "datePublished": "2021-12-22T18:06:47",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-08-03T18:30:23.083Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21903 (GCVE-0-2021-21903)
Vulnerability from cvelistv5
Published
2021-12-22 18:06
Modified
2024-08-03 18:30
Severity ?
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Summary
A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors’ iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to strcpy. An attacker can send a malicious packet to trigger this vulnerability.
Impacted products
Vendor Product Version
n/a Garrett Metal Detectors Version: Garrett Metal Detectors iC Module CMA Version 5.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:30:23.455Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1355"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Garrett Metal Detectors",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Garrett Metal Detectors iC Module CMA Version 5.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors\u2019 iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to strcpy. An attacker can send a malicious packet to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-22T18:06:45",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1355"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2021-21903",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Garrett Metal Detectors",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Garrett Metal Detectors iC Module CMA Version 5.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A stack-based buffer overflow vulnerability exists in the CMA check_udp_crc function of Garrett Metal Detectors\u2019 iC Module CMA Version 5.0. A specially-crafted packet can lead to a stack-based buffer overflow during a call to strcpy. An attacker can send a malicious packet to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1355",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1355"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2021-21903",
    "datePublished": "2021-12-22T18:06:45",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-08-03T18:30:23.455Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-21907 (GCVE-0-2021-21907)
Vulnerability from cvelistv5
Published
2021-12-22 18:06
Modified
2024-08-03 18:30
CWE
  • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Summary
A directory traversal vulnerability exists in the CMA CLI getenv command functionality of Garrett Metal Detectors’ iC Module CMA Version 5.0. A specially-crafted command line argument can lead to local file inclusion. An attacker can provide malicious input to trigger this vulnerability.
Impacted products
Vendor Product Version
n/a Garrett Metal Detectors Version: Garrett Metal Detectors iC Module CMA Version 5.0
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:30:22.876Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1358"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Garrett Metal Detectors",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Garrett Metal Detectors iC Module CMA Version 5.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A directory traversal vulnerability exists in the CMA CLI getenv command functionality of Garrett Metal Detectors\u2019 iC Module CMA Version 5.0. A specially-crafted command line argument can lead to local file inclusion. An attacker can provide malicious input to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-22T18:06:49",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1358"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "ID": "CVE-2021-21907",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Garrett Metal Detectors",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Garrett Metal Detectors iC Module CMA Version 5.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A directory traversal vulnerability exists in the CMA CLI getenv command functionality of Garrett Metal Detectors\u2019 iC Module CMA Version 5.0. A specially-crafted command line argument can lead to local file inclusion. An attacker can provide malicious input to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 4.9,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1358",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1358"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2021-21907",
    "datePublished": "2021-12-22T18:06:49",
    "dateReserved": "2021-01-04T00:00:00",
    "dateUpdated": "2024-08-03T18:30:22.876Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}