CVE-2020-5344 (GCVE-0-2020-5344)
Vulnerability from cvelistv5
Published
2020-03-31 21:30
Modified
2024-09-17 02:02
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Summary
Dell EMC iDRAC7, iDRAC8 and iDRAC9 versions prior to 2.65.65.65, 2.70.70.70, 4.00.00.00 contain a stack-based buffer overflow vulnerability. An unauthenticated remote attacker may exploit this vulnerability to crash the affected process or execute arbitrary code on the system by sending specially crafted input data.
References
► | URL | Tags |
---|---|---|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell | Integrated Dell Remote Access Controller (iDRAC) |
Version: unspecified < 2.65.65.65 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:30:23.389Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/article/en-us/sln320717/dsa-2020-063-idrac-buffer-overflow-vulnerability?lang=en" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Integrated Dell Remote Access Controller (iDRAC)", "vendor": "Dell", "versions": [ { "lessThan": "2.65.65.65", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2020-03-26T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell EMC iDRAC7, iDRAC8 and iDRAC9 versions prior to 2.65.65.65, 2.70.70.70, 4.00.00.00 contain a stack-based buffer overflow vulnerability. An unauthenticated remote attacker may exploit this vulnerability to crash the affected process or execute arbitrary code on the system by sending specially crafted input data." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-03-31T21:30:13", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/article/en-us/sln320717/dsa-2020-063-idrac-buffer-overflow-vulnerability?lang=en" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2020-03-26", "ID": "CVE-2020-5344", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Integrated Dell Remote Access Controller (iDRAC)", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "2.65.65.65" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell EMC iDRAC7, iDRAC8 and iDRAC9 versions prior to 2.65.65.65, 2.70.70.70, 4.00.00.00 contain a stack-based buffer overflow vulnerability. An unauthenticated remote attacker may exploit this vulnerability to crash the affected process or execute arbitrary code on the system by sending specially crafted input data." } ] }, "impact": { "cvss": { "baseScore": 7, "baseSeverity": "High", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-121: Stack-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/article/en-us/sln320717/dsa-2020-063-idrac-buffer-overflow-vulnerability?lang=en", "refsource": "MISC", "url": "https://www.dell.com/support/article/en-us/sln320717/dsa-2020-063-idrac-buffer-overflow-vulnerability?lang=en" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2020-5344", "datePublished": "2020-03-31T21:30:13.281285Z", "dateReserved": "2020-01-03T00:00:00", "dateUpdated": "2024-09-17T02:02:37.472Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2014-8272 (GCVE-0-2014-8272)
Vulnerability from cvelistv5
Published
2014-12-19 11:00
Modified
2024-08-06 13:10
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
The IPMI 1.5 functionality in Dell iDRAC6 modular before 3.65, iDRAC6 monolithic before 1.98, and iDRAC7 before 1.57.57 does not properly select session ID values, which makes it easier for remote attackers to execute arbitrary commands via a brute-force attack.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T13:10:50.943Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.kb.cert.org/vuls/id/BLUU-9RDQHM" }, { "name": "35770", "tags": [ "exploit", "x_refsource_EXPLOIT-DB", "x_transferred" ], "url": "http://www.exploit-db.com/exploits/35770" }, { "name": "VU#843044", "tags": [ "third-party-advisory", "x_refsource_CERT-VN", "x_transferred" ], "url": "http://www.kb.cert.org/vuls/id/843044" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2014-12-18T00:00:00", "descriptions": [ { "lang": "en", "value": "The IPMI 1.5 functionality in Dell iDRAC6 modular before 3.65, iDRAC6 monolithic before 1.98, and iDRAC7 before 1.57.57 does not properly select session ID values, which makes it easier for remote attackers to execute arbitrary commands via a brute-force attack." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2015-02-02T15:57:00", "orgId": "37e5125f-f79b-445b-8fad-9564f167944b", "shortName": "certcc" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.kb.cert.org/vuls/id/BLUU-9RDQHM" }, { "name": "35770", "tags": [ "exploit", "x_refsource_EXPLOIT-DB" ], "url": "http://www.exploit-db.com/exploits/35770" }, { "name": "VU#843044", "tags": [ "third-party-advisory", "x_refsource_CERT-VN" ], "url": "http://www.kb.cert.org/vuls/id/843044" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cert@cert.org", "ID": "CVE-2014-8272", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The IPMI 1.5 functionality in Dell iDRAC6 modular before 3.65, iDRAC6 monolithic before 1.98, and iDRAC7 before 1.57.57 does not properly select session ID values, which makes it easier for remote attackers to execute arbitrary commands via a brute-force attack." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.kb.cert.org/vuls/id/BLUU-9RDQHM", "refsource": "CONFIRM", "url": "http://www.kb.cert.org/vuls/id/BLUU-9RDQHM" }, { "name": "35770", "refsource": "EXPLOIT-DB", "url": "http://www.exploit-db.com/exploits/35770" }, { "name": "VU#843044", "refsource": "CERT-VN", "url": "http://www.kb.cert.org/vuls/id/843044" } ] } } } }, "cveMetadata": { "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b", "assignerShortName": "certcc", "cveId": "CVE-2014-8272", "datePublished": "2014-12-19T11:00:00", "dateReserved": "2014-10-12T00:00:00", "dateUpdated": "2024-08-06T13:10:50.943Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2016-5685 (GCVE-0-2016-5685)
Vulnerability from cvelistv5
Published
2016-11-29 15:00
Modified
2024-08-06 01:08
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- string injection
Summary
Dell iDRAC7 and iDRAC8 devices with firmware before 2.40.40.40 allow authenticated users to gain Bash shell access through a string injection.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Dell EMC | iDRAC7 and iDRAC8 |
Version: firmware before 2.40.40.40 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T01:08:00.545Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://en.community.dell.com/techcenter/extras/m/white_papers/20443326" }, { "name": "94585", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/94585" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "iDRAC7 and iDRAC8", "vendor": "Dell EMC", "versions": [ { "status": "affected", "version": "firmware before 2.40.40.40" } ] } ], "datePublic": "2016-11-16T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell iDRAC7 and iDRAC8 devices with firmware before 2.40.40.40 allow authenticated users to gain Bash shell access through a string injection." } ], "problemTypes": [ { "descriptions": [ { "description": "string injection", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2016-12-12T14:57:01", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://en.community.dell.com/techcenter/extras/m/white_papers/20443326" }, { "name": "94585", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/94585" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "security_alert@emc.com", "ID": "CVE-2016-5685", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "iDRAC7 and iDRAC8", "version": { "version_data": [ { "version_value": "firmware before 2.40.40.40" } ] } } ] }, "vendor_name": "Dell EMC" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell iDRAC7 and iDRAC8 devices with firmware before 2.40.40.40 allow authenticated users to gain Bash shell access through a string injection." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "string injection" } ] } ] }, "references": { "reference_data": [ { "name": "http://en.community.dell.com/techcenter/extras/m/white_papers/20443326", "refsource": "CONFIRM", "url": "http://en.community.dell.com/techcenter/extras/m/white_papers/20443326" }, { "name": "94585", "refsource": "BID", "url": "http://www.securityfocus.com/bid/94585" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2016-5685", "datePublished": "2016-11-29T15:00:00", "dateReserved": "2016-06-16T00:00:00", "dateUpdated": "2024-08-06T01:08:00.545Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2013-3589 (GCVE-0-2013-3589)
Vulnerability from cvelistv5
Published
2013-09-24 10:00
Modified
2024-09-16 18:23
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Cross-site scripting (XSS) vulnerability in the login page in the Administrative Web Interface on Dell iDRAC6 monolithic devices with firmware before 1.96 and iDRAC7 devices with firmware before 1.46.45 allows remote attackers to inject arbitrary web script or HTML via the ErrorMsg parameter.
References
► | URL | Tags | ||||||
---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T16:14:56.448Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.kb.cert.org/vuls/id/BLUU-997QVW" }, { "name": "VU#920038", "tags": [ "third-party-advisory", "x_refsource_CERT-VN", "x_transferred" ], "url": "http://www.kb.cert.org/vuls/id/920038" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Cross-site scripting (XSS) vulnerability in the login page in the Administrative Web Interface on Dell iDRAC6 monolithic devices with firmware before 1.96 and iDRAC7 devices with firmware before 1.46.45 allows remote attackers to inject arbitrary web script or HTML via the ErrorMsg parameter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2013-09-24T10:00:00Z", "orgId": "37e5125f-f79b-445b-8fad-9564f167944b", "shortName": "certcc" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.kb.cert.org/vuls/id/BLUU-997QVW" }, { "name": "VU#920038", "tags": [ "third-party-advisory", "x_refsource_CERT-VN" ], "url": "http://www.kb.cert.org/vuls/id/920038" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cert@cert.org", "ID": "CVE-2013-3589", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Cross-site scripting (XSS) vulnerability in the login page in the Administrative Web Interface on Dell iDRAC6 monolithic devices with firmware before 1.96 and iDRAC7 devices with firmware before 1.46.45 allows remote attackers to inject arbitrary web script or HTML via the ErrorMsg parameter." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.kb.cert.org/vuls/id/BLUU-997QVW", "refsource": "CONFIRM", "url": "http://www.kb.cert.org/vuls/id/BLUU-997QVW" }, { "name": "VU#920038", "refsource": "CERT-VN", "url": "http://www.kb.cert.org/vuls/id/920038" } ] } } } }, "cveMetadata": { "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b", "assignerShortName": "certcc", "cveId": "CVE-2013-3589", "datePublished": "2013-09-24T10:00:00Z", "dateReserved": "2013-05-21T00:00:00Z", "dateUpdated": "2024-09-16T18:23:58.443Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2016-11-29 15:59
Modified
2025-04-12 10:46
Severity ?
Summary
Dell iDRAC7 and iDRAC8 devices with firmware before 2.40.40.40 allow authenticated users to gain Bash shell access through a string injection.
References
▶ | URL | Tags | |
---|---|---|---|
security_alert@emc.com | http://en.community.dell.com/techcenter/extras/m/white_papers/20443326 | Vendor Advisory | |
security_alert@emc.com | http://www.securityfocus.com/bid/94585 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | http://en.community.dell.com/techcenter/extras/m/white_papers/20443326 | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/94585 | Third Party Advisory, VDB Entry |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dell | idrac7_firmware | * | |
dell | idrac8_firmware | * | |
dell | idrac7 | - | |
dell | idrac8 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dell:idrac7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2A6BAA26-9F81-4B51-8898-0B1CEB980A7C", "versionEndIncluding": "2.30.30.30", "vulnerable": true }, { "criteria": "cpe:2.3:o:dell:idrac8_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3237F85F-972C-4701-A57A-2DE97488FC22", "versionEndIncluding": "2.30.30.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dell:idrac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "6B004193-6FCE-4E0C-9B3F-D56B4605701B", "vulnerable": false }, { "criteria": "cpe:2.3:h:dell:idrac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "B0591F64-CBB4-440D-AB35-F8D5AC8A536B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Dell iDRAC7 and iDRAC8 devices with firmware before 2.40.40.40 allow authenticated users to gain Bash shell access through a string injection." }, { "lang": "es", "value": "Los dispositivos Dell iDRAC7 e iDRAC8 con firmware en versiones anteriores a 2.40.40.40 permiten a usuarios autenticados obtener acceso al shell Bash a trav\u00e9s de una inyecci\u00f3n de cadena." } ], "id": "CVE-2016-5685", "lastModified": "2025-04-12T10:46:40.837", "metrics": { "cvssMetricV2": [ { "acInsufInfo": true, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2016-11-29T15:59:00.200", "references": [ { "source": "security_alert@emc.com", "tags": [ "Vendor Advisory" ], "url": "http://en.community.dell.com/techcenter/extras/m/white_papers/20443326" }, { "source": "security_alert@emc.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/94585" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://en.community.dell.com/techcenter/extras/m/white_papers/20443326" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/94585" } ], "sourceIdentifier": "security_alert@emc.com", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-74" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2014-12-19 11:59
Modified
2025-04-12 10:46
Severity ?
Summary
The IPMI 1.5 functionality in Dell iDRAC6 modular before 3.65, iDRAC6 monolithic before 1.98, and iDRAC7 before 1.57.57 does not properly select session ID values, which makes it easier for remote attackers to execute arbitrary commands via a brute-force attack.
References
▶ | URL | Tags | |
---|---|---|---|
cret@cert.org | http://www.exploit-db.com/exploits/35770 | Exploit | |
cret@cert.org | http://www.kb.cert.org/vuls/id/843044 | Third Party Advisory, US Government Resource | |
cret@cert.org | http://www.kb.cert.org/vuls/id/BLUU-9RDQHM | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.exploit-db.com/exploits/35770 | Exploit | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.kb.cert.org/vuls/id/843044 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.kb.cert.org/vuls/id/BLUU-9RDQHM | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dell | idrac6_modular | * | |
dell | idrac7 | * | |
intel | ipmi | 1.5 | |
dell | idrac6_monolithic | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:dell:idrac6_modular:*:*:*:*:*:*:*:*", "matchCriteriaId": "A460E054-878C-4E63-945F-7FC03D07E302", "versionEndIncluding": "3.60", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:dell:idrac7:*:*:*:*:*:*:*:*", "matchCriteriaId": "A4DBDA63-E3CD-486A-864A-9C9B078ACC97", "versionEndIncluding": "1.56.55", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:ipmi:1.5:*:*:*:*:*:*:*", "matchCriteriaId": "21DFF96C-EBE3-4CAC-B281-50C0A2728C10", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:dell:idrac6_monolithic:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3D463D1-92B9-481C-BC39-3E5EDA630A3E", "versionEndIncluding": "1.97", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The IPMI 1.5 functionality in Dell iDRAC6 modular before 3.65, iDRAC6 monolithic before 1.98, and iDRAC7 before 1.57.57 does not properly select session ID values, which makes it easier for remote attackers to execute arbitrary commands via a brute-force attack." }, { "lang": "es", "value": "La funcionalidad IPMI 1.5 en Dell iDRAC6 modular anterior a 3.65, iDRAC6 monol\u00edtico anterior a 1.98 e iDRAC7 anterior a 1.57.57 no selecciona correctamente los valores ID de sesi\u00f3n, lo que facilita a atacantes remotos ejecutar comandos arbitrarios a trav\u00e9s de ataques de fuerza bruta." } ], "evaluatorComment": "\u003ca href=\"http://cwe.mitre.org/data/definitions/330.html\"\u003eCWE-330: Use of Insufficiently Random Values\u003c/a\u003e", "id": "CVE-2014-8272", "lastModified": "2025-04-12T10:46:40.837", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2014-12-19T11:59:05.290", "references": [ { "source": "cret@cert.org", "tags": [ "Exploit" ], "url": "http://www.exploit-db.com/exploits/35770" }, { "source": "cret@cert.org", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "http://www.kb.cert.org/vuls/id/843044" }, { "source": "cret@cert.org", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "http://www.kb.cert.org/vuls/id/BLUU-9RDQHM" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Exploit" ], "url": "http://www.exploit-db.com/exploits/35770" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "http://www.kb.cert.org/vuls/id/843044" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "http://www.kb.cert.org/vuls/id/BLUU-9RDQHM" } ], "sourceIdentifier": "cret@cert.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-03-31 22:15
Modified
2024-11-21 05:33
Severity ?
7.0 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Dell EMC iDRAC7, iDRAC8 and iDRAC9 versions prior to 2.65.65.65, 2.70.70.70, 4.00.00.00 contain a stack-based buffer overflow vulnerability. An unauthenticated remote attacker may exploit this vulnerability to crash the affected process or execute arbitrary code on the system by sending specially crafted input data.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dell | idrac7_firmware | * | |
dell | idrac7 | - | |
dell | idrac8_firmware | * | |
dell | idrac8 | - | |
dell | idrac9_firmware | * | |
dell | idrac9 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dell:idrac7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3494B3FA-1BE5-4817-9F92-1A19F2776680", "versionEndExcluding": "2.65.65.65", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dell:idrac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "6B004193-6FCE-4E0C-9B3F-D56B4605701B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dell:idrac8_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3081DFE4-72FC-497B-946D-9B9AB9AFCC76", "versionEndExcluding": "2.70.70.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dell:idrac8:-:*:*:*:*:*:*:*", "matchCriteriaId": "B0591F64-CBB4-440D-AB35-F8D5AC8A536B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3F9892D-A0B0-4938-9C38-C8A511860011", "versionEndExcluding": "4.00.00.00", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dell:idrac9:-:*:*:*:*:*:*:*", "matchCriteriaId": "BD8B684E-092F-496C-9D94-51CCD1F3575A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Dell EMC iDRAC7, iDRAC8 and iDRAC9 versions prior to 2.65.65.65, 2.70.70.70, 4.00.00.00 contain a stack-based buffer overflow vulnerability. An unauthenticated remote attacker may exploit this vulnerability to crash the affected process or execute arbitrary code on the system by sending specially crafted input data." }, { "lang": "es", "value": "Dell EMC iDRAC7, iDRAC8 e iDRAC9 versiones anteriores a 2.65.65.65, 2.70.70.70, 4.00.00.00, contienen una vulnerabilidad de desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria. Un atacante remoto no autenticado puede explotar esta vulnerabilidad para bloquear el proceso afectado o ejecutar c\u00f3digo arbitrario sobre el sistema mediante el env\u00edo de datos de entrada especialmente dise\u00f1ados." } ], "id": "CVE-2020-5344", "lastModified": "2024-11-21T05:33:57.083", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.0, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 4.7, "source": "security_alert@emc.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-03-31T22:15:14.760", "references": [ { "source": "security_alert@emc.com", "tags": [ "Vendor Advisory" ], "url": "https://www.dell.com/support/article/en-us/sln320717/dsa-2020-063-idrac-buffer-overflow-vulnerability?lang=en" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dell.com/support/article/en-us/sln320717/dsa-2020-063-idrac-buffer-overflow-vulnerability?lang=en" } ], "sourceIdentifier": "security_alert@emc.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "security_alert@emc.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2013-09-24 10:35
Modified
2025-04-11 00:51
Severity ?
Summary
Cross-site scripting (XSS) vulnerability in the login page in the Administrative Web Interface on Dell iDRAC6 monolithic devices with firmware before 1.96 and iDRAC7 devices with firmware before 1.46.45 allows remote attackers to inject arbitrary web script or HTML via the ErrorMsg parameter.
References
▶ | URL | Tags | |
---|---|---|---|
cret@cert.org | http://www.kb.cert.org/vuls/id/920038 | US Government Resource | |
cret@cert.org | http://www.kb.cert.org/vuls/id/BLUU-997QVW | US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.kb.cert.org/vuls/id/920038 | US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.kb.cert.org/vuls/id/BLUU-997QVW | US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dell | idrac6_firmware | * | |
dell | idrac6_firmware | 1.0 | |
dell | idrac6_firmware | 1.1 | |
dell | idrac6_firmware | 1.2 | |
dell | idrac6_firmware | 1.3 | |
dell | idrac6_firmware | 1.5 | |
dell | idrac6_firmware | 1.6 | |
dell | idrac6_firmware | 1.8 | |
dell | idrac6_monolithic | - | |
dell | idrac7_firmware | * | |
dell | idrac7_firmware | 1.00.00 | |
dell | idrac7_firmware | 1.06.06 | |
dell | idrac7_firmware | 1.10.10 | |
dell | idrac7_firmware | 1.20.20 | |
dell | idrac7_firmware | 1.23.23 | |
dell | idrac7_firmware | 1.37.35 | |
dell | idrac7 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dell:idrac6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D9D5B45-9540-438A-9865-C2BC1FABECE8", "versionEndIncluding": "1.95", "vulnerable": true }, { "criteria": "cpe:2.3:o:dell:idrac6_firmware:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "8165B5AB-8EC5-409A-9B82-2FE1C801E93E", "vulnerable": true }, { "criteria": "cpe:2.3:o:dell:idrac6_firmware:1.1:*:*:*:*:*:*:*", "matchCriteriaId": "E0432217-2FD7-49B4-8CB3-F9CD107F321B", "vulnerable": true }, { "criteria": "cpe:2.3:o:dell:idrac6_firmware:1.2:*:*:*:*:*:*:*", "matchCriteriaId": "3CE3EFC4-0E43-4474-95A0-EE010E4432EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:dell:idrac6_firmware:1.3:*:*:*:*:*:*:*", "matchCriteriaId": "88F80B6F-D37C-4EF8-9307-548289B8D0E8", "vulnerable": true }, { "criteria": "cpe:2.3:o:dell:idrac6_firmware:1.5:*:*:*:*:*:*:*", "matchCriteriaId": "37C84DCC-B988-41FC-83FF-3265FBD20436", "vulnerable": true }, { "criteria": "cpe:2.3:o:dell:idrac6_firmware:1.6:*:*:*:*:*:*:*", "matchCriteriaId": "282B62D0-949E-4664-AFE0-19A32AAE8583", "vulnerable": true }, { "criteria": "cpe:2.3:o:dell:idrac6_firmware:1.8:*:*:*:*:*:*:*", "matchCriteriaId": "D5272179-2DFF-4880-9FA5-4AC95A584B62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dell:idrac6_monolithic:-:*:*:*:*:*:*:*", "matchCriteriaId": "1178ECF0-A8BD-4236-83D8-5F39CD8BF6F2", "vulnerable": true } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dell:idrac7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93014C51-F915-4635-A479-EEE4FC3816A1", "versionEndIncluding": "1.40.40", "vulnerable": true }, { "criteria": "cpe:2.3:o:dell:idrac7_firmware:1.00.00:*:*:*:*:*:*:*", "matchCriteriaId": "E072CD73-1FB4-46A5-96B4-C9440ACCD2B5", "vulnerable": true }, { "criteria": "cpe:2.3:o:dell:idrac7_firmware:1.06.06:*:*:*:*:*:*:*", "matchCriteriaId": "5F7E3E21-56E5-4F13-AE6C-6BD2A5D57FEE", "vulnerable": true }, { "criteria": "cpe:2.3:o:dell:idrac7_firmware:1.10.10:*:*:*:*:*:*:*", "matchCriteriaId": "F8E06108-77C9-4F9C-A0B1-BEDC5C23D862", "vulnerable": true }, { "criteria": "cpe:2.3:o:dell:idrac7_firmware:1.20.20:*:*:*:*:*:*:*", "matchCriteriaId": "3542F818-1A1F-4B75-BA24-E5699F602301", "vulnerable": true }, { "criteria": "cpe:2.3:o:dell:idrac7_firmware:1.23.23:*:*:*:*:*:*:*", "matchCriteriaId": "539A6346-747E-4ACA-B048-3C7DEF6CC2AA", "vulnerable": true }, { "criteria": "cpe:2.3:o:dell:idrac7_firmware:1.37.35:*:*:*:*:*:*:*", "matchCriteriaId": "32A7E775-FB16-4031-B85B-F0944251F4B6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dell:idrac7:-:*:*:*:*:*:*:*", "matchCriteriaId": "6B004193-6FCE-4E0C-9B3F-D56B4605701B", "vulnerable": true } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Cross-site scripting (XSS) vulnerability in the login page in the Administrative Web Interface on Dell iDRAC6 monolithic devices with firmware before 1.96 and iDRAC7 devices with firmware before 1.46.45 allows remote attackers to inject arbitrary web script or HTML via the ErrorMsg parameter." }, { "lang": "es", "value": "Vulnerabilidad XSS en la p\u00e1gina de login del interfaz de administraci\u00f3n web en los dispositivos monol\u00edticos Dell iDRAC6 con firmware anterior a v1.46.45 permite a atacantes remotos inyectar secuencias de comandos web o HTML arbitrarias a trav\u00e9s del par\u00e1metro \"ErrorMsg\"." } ], "id": "CVE-2013-3589", "lastModified": "2025-04-11T00:51:21.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ] }, "published": "2013-09-24T10:35:51.923", "references": [ { "source": "cret@cert.org", "tags": [ "US Government Resource" ], "url": "http://www.kb.cert.org/vuls/id/920038" }, { "source": "cret@cert.org", "tags": [ "US Government Resource" ], "url": "http://www.kb.cert.org/vuls/id/BLUU-997QVW" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "US Government Resource" ], "url": "http://www.kb.cert.org/vuls/id/920038" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "US Government Resource" ], "url": "http://www.kb.cert.org/vuls/id/BLUU-997QVW" } ], "sourceIdentifier": "cret@cert.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }