Vulnerabilites related to philips - intellivue_np90_firmware
Vulnerability from fkie_nvd
Published
2018-06-05 20:29
Modified
2024-11-21 03:41
Summary
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory ("write-what-where") from an attacker-chosen device address within the same subnet.
References



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D4DC680B-B8F8-4FAA-B4C3-D36003BDDCCA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9178E4C-8965-496C-9FF7-1DF87371DC48",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_x2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E42604C2-7CB6-42AC-9272-CFABFC4DC85A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_x2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29626D40-46F7-485F-A700-070424820F16",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp30_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "314F12E4-D613-43C4-9B14-5FC9F598AD55",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E089B9E5-8B28-4DBA-A5D0-B6BBB7D5F3E8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp50_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EE71984-367F-428F-AD0E-D168F76A2002",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp50:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7216177F-179D-451E-ABC3-C1843AF0D35F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp70_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "41A04EC9-FAC7-4C36-8E95-4BDC1E0702FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp70:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F608D38-1096-41F9-9EB5-854C79068144",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_np90_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A47C624-AF39-4BE2-9484-54A5E51A784B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_np90:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C202FA49-1CC4-46E6-AA11-3EAB17008AA2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx700_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "43C2466F-A371-4386-B098-F724D5CD14CB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DDF21FA3-9650-442F-8E13-281A9975C47B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx800_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9C6A5F3-C845-4561-A451-DC3C966E8D8C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C38B732B-8629-40FE-A333-E69A7F2CFB18",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx400_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58F21718-A0DE-419E-B82D-447ADC337E30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27B8D0E2-316A-45E5-8FC1-AE70F07DB7FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx450_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C337EAF0-41E9-4BF3-8483-6FC74EA93B5A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx450:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E73CF245-4519-4F35-A5EE-74981E0BDB9F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx500_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E119897D-9FB5-461C-8463-EBA3CFC87855",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0CEB056-7422-4E4E-86A5-D58311129788",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx550_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6D72DF93-DF02-411D-80BE-85286F553B1E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx550:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B03E7D9-01DC-492F-BA52-9165E78BE498",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_x3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "708EB7F4-9747-4B0C-937D-F1ED07300FAE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_x3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F68AF067-6802-40E7-9D34-03D83D9F3E77",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx100_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D7C4F77-6005-4AAA-83CA-CA9F60043A7A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D2A5BBF-C360-4281-AD34-C0941831DA64",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm20_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3834798-6741-4274-B5C5-0CA2C13A7B12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm20:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A418F05-18B3-405E-A62C-4D9677C297DB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm30_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5634CF44-3593-4D58-8B72-D3DA253530F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C74CF2F-501F-4D18-82C7-4D25D42905E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm40_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55DCC271-9428-4A34-B2C8-DA3CCB74D2DD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm40:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FD8C562-C918-47DF-AFEB-4CFA53DE3D22",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm50_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AB9A60A-D567-4B7A-A73A-AA566CAD739A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm50:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D192DA1-C9F4-4666-B0E3-6B0529E3BF3B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory (\"write-what-where\") from an attacker-chosen device address within the same subnet."
    },
    {
      "lang": "es",
      "value": "IntelliVue Patient Monitors MP Series (incluyendo MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M y (X3/MX100 solo para Rev M) y Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 con software Revisions F.0, G.0 y J.3 tienen una vulnerabilidad que permite que un atacante no autenticado acceda a memoria (\"write-what-where\") desde una direcci\u00f3n del dispositivo escogida por el atacante en la misma subred."
    }
  ],
  "id": "CVE-2018-10597",
  "lastModified": "2024-11-21T03:41:37.970",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.4,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:A/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 5.5,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 6.0,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-06-05T20:29:00.827",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-06-05 20:29
Modified
2024-11-21 03:41
Summary
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet.
References



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D4DC680B-B8F8-4FAA-B4C3-D36003BDDCCA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9178E4C-8965-496C-9FF7-1DF87371DC48",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_x2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E42604C2-7CB6-42AC-9272-CFABFC4DC85A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_x2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29626D40-46F7-485F-A700-070424820F16",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp30_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "314F12E4-D613-43C4-9B14-5FC9F598AD55",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E089B9E5-8B28-4DBA-A5D0-B6BBB7D5F3E8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp50_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EE71984-367F-428F-AD0E-D168F76A2002",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp50:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7216177F-179D-451E-ABC3-C1843AF0D35F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp70_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "41A04EC9-FAC7-4C36-8E95-4BDC1E0702FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp70:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F608D38-1096-41F9-9EB5-854C79068144",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_np90_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A47C624-AF39-4BE2-9484-54A5E51A784B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_np90:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C202FA49-1CC4-46E6-AA11-3EAB17008AA2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx700_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "43C2466F-A371-4386-B098-F724D5CD14CB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DDF21FA3-9650-442F-8E13-281A9975C47B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx800_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9C6A5F3-C845-4561-A451-DC3C966E8D8C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C38B732B-8629-40FE-A333-E69A7F2CFB18",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx400_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58F21718-A0DE-419E-B82D-447ADC337E30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27B8D0E2-316A-45E5-8FC1-AE70F07DB7FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx450_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C337EAF0-41E9-4BF3-8483-6FC74EA93B5A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx450:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E73CF245-4519-4F35-A5EE-74981E0BDB9F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx500_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E119897D-9FB5-461C-8463-EBA3CFC87855",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0CEB056-7422-4E4E-86A5-D58311129788",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx550_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6D72DF93-DF02-411D-80BE-85286F553B1E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx550:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B03E7D9-01DC-492F-BA52-9165E78BE498",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_x3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "708EB7F4-9747-4B0C-937D-F1ED07300FAE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_x3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F68AF067-6802-40E7-9D34-03D83D9F3E77",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx100_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D7C4F77-6005-4AAA-83CA-CA9F60043A7A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D2A5BBF-C360-4281-AD34-C0941831DA64",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm20_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3834798-6741-4274-B5C5-0CA2C13A7B12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm20:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A418F05-18B3-405E-A62C-4D9677C297DB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm30_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5634CF44-3593-4D58-8B72-D3DA253530F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C74CF2F-501F-4D18-82C7-4D25D42905E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm40_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55DCC271-9428-4A34-B2C8-DA3CCB74D2DD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm40:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FD8C562-C918-47DF-AFEB-4CFA53DE3D22",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm50_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AB9A60A-D567-4B7A-A73A-AA566CAD739A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm50:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D192DA1-C9F4-4666-B0E3-6B0529E3BF3B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet."
    },
    {
      "lang": "es",
      "value": "IntelliVue Patient Monitors MP Series (incluyendo MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M y (X3/MX100 solo para Rev M) y Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 con software Revisions F.0, G.0 y J.3 tienen una vulnerabilidad que permite que un atacante no autenticado lea memoria desde una direcci\u00f3n del dispositivo escogida por el atacante en la misma subred."
    }
  ],
  "id": "CVE-2018-10599",
  "lastModified": "2024-11-21T03:41:38.247",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 2.9,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:A/AC:M/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 5.5,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-06-05T20:29:00.873",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-06-05 20:29
Modified
2024-11-21 03:41
Summary
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an "echo" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.
References



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D4DC680B-B8F8-4FAA-B4C3-D36003BDDCCA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9178E4C-8965-496C-9FF7-1DF87371DC48",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_x2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E42604C2-7CB6-42AC-9272-CFABFC4DC85A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_x2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29626D40-46F7-485F-A700-070424820F16",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp30_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "314F12E4-D613-43C4-9B14-5FC9F598AD55",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E089B9E5-8B28-4DBA-A5D0-B6BBB7D5F3E8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp50_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EE71984-367F-428F-AD0E-D168F76A2002",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp50:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7216177F-179D-451E-ABC3-C1843AF0D35F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mp70_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "41A04EC9-FAC7-4C36-8E95-4BDC1E0702FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mp70:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F608D38-1096-41F9-9EB5-854C79068144",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_np90_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A47C624-AF39-4BE2-9484-54A5E51A784B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_np90:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C202FA49-1CC4-46E6-AA11-3EAB17008AA2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx700_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "43C2466F-A371-4386-B098-F724D5CD14CB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DDF21FA3-9650-442F-8E13-281A9975C47B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx800_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9C6A5F3-C845-4561-A451-DC3C966E8D8C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C38B732B-8629-40FE-A333-E69A7F2CFB18",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx400_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58F21718-A0DE-419E-B82D-447ADC337E30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27B8D0E2-316A-45E5-8FC1-AE70F07DB7FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx450_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C337EAF0-41E9-4BF3-8483-6FC74EA93B5A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx450:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E73CF245-4519-4F35-A5EE-74981E0BDB9F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx500_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E119897D-9FB5-461C-8463-EBA3CFC87855",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0CEB056-7422-4E4E-86A5-D58311129788",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx550_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6D72DF93-DF02-411D-80BE-85286F553B1E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx550:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B03E7D9-01DC-492F-BA52-9165E78BE498",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_x3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "708EB7F4-9747-4B0C-937D-F1ED07300FAE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_x3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F68AF067-6802-40E7-9D34-03D83D9F3E77",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:intellivue_mx100_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D7C4F77-6005-4AAA-83CA-CA9F60043A7A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:intellivue_mx100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D2A5BBF-C360-4281-AD34-C0941831DA64",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm20_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3834798-6741-4274-B5C5-0CA2C13A7B12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm20:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A418F05-18B3-405E-A62C-4D9677C297DB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm30_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5634CF44-3593-4D58-8B72-D3DA253530F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C74CF2F-501F-4D18-82C7-4D25D42905E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm40_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55DCC271-9428-4A34-B2C8-DA3CCB74D2DD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm40:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FD8C562-C918-47DF-AFEB-4CFA53DE3D22",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:philips:avalon_fetal\\/maternal_monitors_fm50_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AB9A60A-D567-4B7A-A73A-AA566CAD739A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:philips:avalon_fetal\\/maternal_monitors_fm50:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D192DA1-C9F4-4666-B0E3-6B0529E3BF3B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an \"echo\" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow."
    },
    {
      "lang": "es",
      "value": "IntelliVue Patient Monitors MP Series (incluyendo MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M y (X3/MX100 solo para Rev M) y Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 con software en Revisions F.0, G.0 y J.3 tienen una vulnerabilidad que expone un servicio \"echo\" por el cual un b\u00fafer enviado por el atacante a una direcci\u00f3n de dispositivo en la misma subred elegida por el atacante se copia a la pila sin comprobaciones de l\u00edmites, lo que resulta en un desbordamiento de pila."
    }
  ],
  "id": "CVE-2018-10601",
  "lastModified": "2024-11-21T03:41:38.507",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.4,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:A/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 5.5,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:L/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 6.0,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-06-05T20:29:00.903",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2018-10597 (GCVE-0-2018-10597)
Vulnerability from cvelistv5
Published
2018-06-05 20:00
Modified
2024-09-16 23:46
Severity ?
CWE
  • CWE-287 - IMPROPER AUTHENTICATION
Summary
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory ("write-what-where") from an attacker-chosen device address within the same subnet.
References
Impacted products
Vendor Product Version
ICS-CERT IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors Version: The following IntelliVue Patient Monitors versions are affected: IntelliVue Patient Monitors MP Series (includingMP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, and IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only). The following Avalon Fetal/Maternal Monitors versions are affected: Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:39:08.450Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "The following IntelliVue Patient Monitors versions are affected: IntelliVue Patient Monitors MP Series (includingMP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, and IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only). The following Avalon Fetal/Maternal Monitors versions are affected: Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3"
            }
          ]
        }
      ],
      "datePublic": "2018-06-05T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory (\"write-what-where\") from an attacker-chosen device address within the same subnet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "IMPROPER AUTHENTICATION CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-06-05T19:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-06-05T00:00:00",
          "ID": "CVE-2018-10597",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "The following IntelliVue Patient Monitors versions are affected: IntelliVue Patient Monitors MP Series (includingMP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, and IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only). The following Avalon Fetal/Maternal Monitors versions are affected: Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to access memory (\"write-what-where\") from an attacker-chosen device address within the same subnet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER AUTHENTICATION CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-10597",
    "datePublished": "2018-06-05T20:00:00Z",
    "dateReserved": "2018-05-01T00:00:00",
    "dateUpdated": "2024-09-16T23:46:22.088Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-10601 (GCVE-0-2018-10601)
Vulnerability from cvelistv5
Published
2018-06-05 20:00
Modified
2024-09-17 02:36
Severity ?
CWE
  • CWE-121 - STACK-BASED BUFFER OVERFLOW
Summary
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an "echo" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.
References
Impacted products
Vendor Product Version
ICS-CERT IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors Version: The following IntelliVue Patient Monitors versions are affected: IntelliVue Patient Monitors MP Series (includingMP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, and IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only). The following Avalon Fetal/Maternal Monitors versions are affected: Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:39:08.363Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "The following IntelliVue Patient Monitors versions are affected: IntelliVue Patient Monitors MP Series (includingMP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, and IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only). The following Avalon Fetal/Maternal Monitors versions are affected: Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3"
            }
          ]
        }
      ],
      "datePublic": "2018-06-05T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an \"echo\" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "STACK-BASED BUFFER OVERFLOW CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-06-05T19:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-06-05T00:00:00",
          "ID": "CVE-2018-10601",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "The following IntelliVue Patient Monitors versions are affected: IntelliVue Patient Monitors MP Series (includingMP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, and IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only). The following Avalon Fetal/Maternal Monitors versions are affected: Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that exposes an \"echo\" service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "STACK-BASED BUFFER OVERFLOW CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-10601",
    "datePublished": "2018-06-05T20:00:00Z",
    "dateReserved": "2018-05-01T00:00:00",
    "dateUpdated": "2024-09-17T02:36:04.782Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-10599 (GCVE-0-2018-10599)
Vulnerability from cvelistv5
Published
2018-06-05 20:00
Modified
2024-09-16 16:33
Severity ?
CWE
Summary
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet.
References
Impacted products
Vendor Product Version
ICS-CERT IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors Version: The following IntelliVue Patient Monitors versions are affected: IntelliVue Patient Monitors MP Series (includingMP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, and IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only). The following Avalon Fetal/Maternal Monitors versions are affected: Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:39:08.304Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "The following IntelliVue Patient Monitors versions are affected: IntelliVue Patient Monitors MP Series (includingMP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, and IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only). The following Avalon Fetal/Maternal Monitors versions are affected: Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3"
            }
          ]
        }
      ],
      "datePublic": "2018-06-05T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "INFORMATION EXPOSURE CWE-200",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-06-05T19:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-06-05T00:00:00",
          "ID": "CVE-2018-10599",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IntelliVue Patient Monitors, Avalon Fetal/Maternal Monitors",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "The following IntelliVue Patient Monitors versions are affected: IntelliVue Patient Monitors MP Series (includingMP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, and IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only). The following Avalon Fetal/Maternal Monitors versions are affected: Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "INFORMATION EXPOSURE CWE-200"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-156-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-10599",
    "datePublished": "2018-06-05T20:00:00Z",
    "dateReserved": "2018-05-01T00:00:00",
    "dateUpdated": "2024-09-16T16:33:25.211Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}