Vulnerabilites related to ni - measurementstudio
Vulnerability from fkie_nvd
Published
2013-08-06 20:55
Modified
2025-04-11 00:51
Severity ?
Summary
Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
ni | labview | * | |
ni | labwindows | * | |
ni | measurementstudio | * | |
ni | teststand | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*", "matchCriteriaId": "3815CFE4-4E5E-44BB-B206-520C39DE3674", "versionEndIncluding": "2012", "vulnerable": true }, { "criteria": "cpe:2.3:a:ni:labwindows:*:*:*:*:*:*:*:*", "matchCriteriaId": "EC46A398-C8F3-49B2-BDDE-20DEA80EC941", "versionEndIncluding": "2012", "vulnerable": true }, { "criteria": "cpe:2.3:a:ni:measurementstudio:*:*:*:*:*:*:*:*", "matchCriteriaId": "A12E5F42-B2FC-48F4-8D04-5B59A3869461", "versionEndIncluding": "2013", "vulnerable": true }, { "criteria": "cpe:2.3:a:ni:teststand:*:*:*:*:*:*:*:*", "matchCriteriaId": "68051582-D70F-4B32-A9F9-64A5E33CB481", "versionEndIncluding": "2012", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value." }, { "lang": "es", "value": "Una vulnerabilidad de salto de ruta (path) en el control de 3D Graph ActiveX en el archivo cw3dgrph.ocx en LabWindows/CVI 2012 SP1 y anteriores, LabVIEW 2012 SP1 y anteriores, y otros productos de National Instruments, permiten a los atacantes remotos crear y ejecutar archivos arbitrarios por medio de una ruta (path) de acceso completa en un argumento para el m\u00e9todo ExportStyle, en conjunci\u00f3n con el contenido del archivo en el valor de la propiedad (a) Caption o (b) FormatString." } ], "id": "CVE-2013-5022", "lastModified": "2025-04-11T00:51:21.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2013-08-06T20:55:05.413", "references": [ { "source": "cve@mitre.org", "url": "http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument" }, { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2013-08-06 20:55
Modified
2025-04-11 00:51
Severity ?
Summary
Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
ni | labview | * | |
ni | labwindows | * | |
ni | measurementstudio | * | |
ni | teststand | * | |
abb | datamanager | 1.0.0 | |
abb | datamanager | 6.3.6 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*", "matchCriteriaId": "3815CFE4-4E5E-44BB-B206-520C39DE3674", "versionEndIncluding": "2012", "vulnerable": true }, { "criteria": "cpe:2.3:a:ni:labwindows:*:*:*:*:*:*:*:*", "matchCriteriaId": "EC46A398-C8F3-49B2-BDDE-20DEA80EC941", "versionEndIncluding": "2012", "vulnerable": true }, { "criteria": "cpe:2.3:a:ni:measurementstudio:*:*:*:*:*:*:*:*", "matchCriteriaId": "A12E5F42-B2FC-48F4-8D04-5B59A3869461", "versionEndIncluding": "2013", "vulnerable": true }, { "criteria": "cpe:2.3:a:ni:teststand:*:*:*:*:*:*:*:*", "matchCriteriaId": "68051582-D70F-4B32-A9F9-64A5E33CB481", "versionEndIncluding": "2012", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:abb:datamanager:1.0.0:*:*:*:*:*:*:*", "matchCriteriaId": "A711CA4A-494A-4702-A620-7B09F1FA8495", "vulnerable": true }, { "criteria": "cpe:2.3:a:abb:datamanager:6.3.6:*:*:*:*:*:*:*", "matchCriteriaId": "899330B9-95DB-4229-9BE9-41384016AC12", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value." }, { "lang": "es", "value": "M\u00faltiples vulnerabilidades de salto de ruta (path) en el archivo cwui.ocx de National Instruments , como se usado en National Instruments LabWindows/CVI 2012 SP1 y anteriores, National Instruments LabVIEW 2012 SP1 y anteriores, el componente de Data Analysis en ABB DataManager versi\u00f3n 1 hasta 6.3.6, y otros productos permiten atacantes remotos crear y ejecutar archivos arbitrarios por medio de un acceso de ruta (path) completo en un argumento del m\u00e9todo ExportStyle en el control de (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide o (5) ActiveX CWKnob, en conjunci\u00f3n con el contenido del archivo en el valor de la propiedad (a) Caption o (b) FormatString." } ], "id": "CVE-2013-5021", "lastModified": "2025-04-11T00:51:21.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ] }, "published": "2013-08-06T20:55:05.287", "references": [ { "source": "cve@mitre.org", "url": "http://digital.ni.com/public.nsf/allkb/04B876608790082C86257BD1000CC950?OpenDocument" }, { "source": "cve@mitre.org", "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" }, { "source": "cve@mitre.org", "url": "http://www05.abb.com/global/scot/scot203.nsf/veritydisplay/5975a8a86c82eec2c125798e00551522/%24file/SECURITY_BULLETIN_-_ABBVU-PACT-3BSE072617_DataManager_Vulnerability.pdf" }, { "source": "cve@mitre.org", "url": "http://zerodayinitiative.com/advisories/ZDI-13-120/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://digital.ni.com/public.nsf/allkb/04B876608790082C86257BD1000CC950?OpenDocument" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www05.abb.com/global/scot/scot203.nsf/veritydisplay/5975a8a86c82eec2c125798e00551522/%24file/SECURITY_BULLETIN_-_ABBVU-PACT-3BSE072617_DataManager_Vulnerability.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://zerodayinitiative.com/advisories/ZDI-13-120/" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2013-08-06 20:55
Modified
2025-04-11 00:51
Severity ?
Summary
An ActiveX control in NationalInstruments.Help2.dll in National Instruments NI .NET Class Library Help, as used in Measurement Studio 2013 and earlier and other products, allows remote attackers to obtain sensitive information about the existence of registry keys via crafted (1) key-open or (2) key-close method calls.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
ni | measurementstudio | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:ni:measurementstudio:*:*:*:*:*:*:*:*", "matchCriteriaId": "A12E5F42-B2FC-48F4-8D04-5B59A3869461", "versionEndIncluding": "2013", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "An ActiveX control in NationalInstruments.Help2.dll in National Instruments NI .NET Class Library Help, as used in Measurement Studio 2013 and earlier and other products, allows remote attackers to obtain sensitive information about the existence of registry keys via crafted (1) key-open or (2) key-close method calls." }, { "lang": "es", "value": "Vulnerabilidad sin especificar en un control ActiveX en NationalInstruments.Help2.dll en National Instruments NI .NET Class Library Help tiene un impacto y vectores de ataque desconocidos." } ], "id": "CVE-2013-5024", "lastModified": "2025-04-11T00:51:21.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ] }, "published": "2013-08-06T20:55:05.477", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/allkb/548965C170D6AA2586257BD3004B146B?OpenDocument" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/websearch/D8E97E95D59AC17086257B3600508823?OpenDocument" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/allkb/548965C170D6AA2586257BD3004B146B?OpenDocument" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/websearch/D8E97E95D59AC17086257B3600508823?OpenDocument" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2013-08-06 20:55
Modified
2025-04-11 00:51
Severity ?
Summary
The ActiveX controls in the HelpAsst component in NI Help Links in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allow remote attackers to cause a denial of service by triggering the display of local .chm files.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
ni | diadem | * | |
ni | labview | * | |
ni | labwindows | * | |
ni | measurementstudio | * | |
ni | teststand | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:ni:diadem:*:*:*:*:*:*:*:*", "matchCriteriaId": "651A3465-0A7A-4EE2-B46E-D1E6972767A6", "versionEndIncluding": "2012", "vulnerable": true }, { "criteria": "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*", "matchCriteriaId": "3815CFE4-4E5E-44BB-B206-520C39DE3674", "versionEndIncluding": "2012", "vulnerable": true }, { "criteria": "cpe:2.3:a:ni:labwindows:*:*:*:*:*:*:*:*", "matchCriteriaId": "EC46A398-C8F3-49B2-BDDE-20DEA80EC941", "versionEndIncluding": "2012", "vulnerable": true }, { "criteria": "cpe:2.3:a:ni:measurementstudio:*:*:*:*:*:*:*:*", "matchCriteriaId": "A12E5F42-B2FC-48F4-8D04-5B59A3869461", "versionEndIncluding": "2013", "vulnerable": true }, { "criteria": "cpe:2.3:a:ni:teststand:*:*:*:*:*:*:*:*", "matchCriteriaId": "68051582-D70F-4B32-A9F9-64A5E33CB481", "versionEndIncluding": "2012", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The ActiveX controls in the HelpAsst component in NI Help Links in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allow remote attackers to cause a denial of service by triggering the display of local .chm files." }, { "lang": "es", "value": "Vulnerabilidad sin especificar en un control ActiveX en el componente HelpAsst en NI Help Links in National Instruments LabWindows/CVI, LabVIEW, y otros productos, tiene un impacto desconocido y vectores de ataque remotos." } ], "id": "CVE-2013-5023", "lastModified": "2025-04-11T00:51:21.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ] }, "published": "2013-08-06T20:55:05.453", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/allkb/E6BC4F119D49A97A86257BD3004FE019?OpenDocument" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" }, { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/websearch/5C87A3AA7300868986257B3600501FE6?OpenDocument" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/allkb/E6BC4F119D49A97A86257BD3004FE019?OpenDocument" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://digital.ni.com/public.nsf/websearch/5C87A3AA7300868986257B3600501FE6?OpenDocument" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Deferred", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2013-5022 (GCVE-0-2013-5022)
Vulnerability from cvelistv5
Published
2013-08-06 18:00
Modified
2024-08-06 16:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value.
References
► | URL | Tags |
---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T16:59:41.206Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2013-05-20T00:00:00", "descriptions": [ { "lang": "en", "value": "Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2013-09-17T09:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2013-5022", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method, in conjunction with file content in the (1) Caption or (2) FormatString property value." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument", "refsource": "CONFIRM", "url": "http://digital.ni.com/public.nsf/allkb/782E4F31442D833186257BD3004AEB47?OpenDocument" }, { "name": "http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument", "refsource": "CONFIRM", "url": "http://digital.ni.com/public.nsf/websearch/C4619A438F7E78E486257B360050BD7D?OpenDocument" }, { "name": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument", "refsource": "CONFIRM", "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2013-5022", "datePublished": "2013-08-06T18:00:00", "dateReserved": "2013-07-31T00:00:00", "dateUpdated": "2024-08-06T16:59:41.206Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2013-5021 (GCVE-0-2013-5021)
Vulnerability from cvelistv5
Published
2013-08-06 18:00
Modified
2024-08-06 16:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T16:59:41.367Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www05.abb.com/global/scot/scot203.nsf/veritydisplay/5975a8a86c82eec2c125798e00551522/%24file/SECURITY_BULLETIN_-_ABBVU-PACT-3BSE072617_DataManager_Vulnerability.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://zerodayinitiative.com/advisories/ZDI-13-120/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://digital.ni.com/public.nsf/allkb/04B876608790082C86257BD1000CC950?OpenDocument" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2013-05-20T00:00:00", "descriptions": [ { "lang": "en", "value": "Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2013-09-17T09:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www05.abb.com/global/scot/scot203.nsf/veritydisplay/5975a8a86c82eec2c125798e00551522/%24file/SECURITY_BULLETIN_-_ABBVU-PACT-3BSE072617_DataManager_Vulnerability.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "http://zerodayinitiative.com/advisories/ZDI-13-120/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://digital.ni.com/public.nsf/allkb/04B876608790082C86257BD1000CC950?OpenDocument" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2013-5021", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www05.abb.com/global/scot/scot203.nsf/veritydisplay/5975a8a86c82eec2c125798e00551522/$file/SECURITY_BULLETIN_-_ABBVU-PACT-3BSE072617_DataManager_Vulnerability.pdf", "refsource": "CONFIRM", "url": "http://www05.abb.com/global/scot/scot203.nsf/veritydisplay/5975a8a86c82eec2c125798e00551522/$file/SECURITY_BULLETIN_-_ABBVU-PACT-3BSE072617_DataManager_Vulnerability.pdf" }, { "name": "http://zerodayinitiative.com/advisories/ZDI-13-120/", "refsource": "MISC", "url": "http://zerodayinitiative.com/advisories/ZDI-13-120/" }, { "name": "http://digital.ni.com/public.nsf/allkb/04B876608790082C86257BD1000CC950?OpenDocument", "refsource": "CONFIRM", "url": "http://digital.ni.com/public.nsf/allkb/04B876608790082C86257BD1000CC950?OpenDocument" }, { "name": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument", "refsource": "CONFIRM", "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2013-5021", "datePublished": "2013-08-06T18:00:00", "dateReserved": "2013-07-31T00:00:00", "dateUpdated": "2024-08-06T16:59:41.367Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2013-5024 (GCVE-0-2013-5024)
Vulnerability from cvelistv5
Published
2013-08-06 18:00
Modified
2024-08-06 16:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
An ActiveX control in NationalInstruments.Help2.dll in National Instruments NI .NET Class Library Help, as used in Measurement Studio 2013 and earlier and other products, allows remote attackers to obtain sensitive information about the existence of registry keys via crafted (1) key-open or (2) key-close method calls.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T16:59:41.194Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://digital.ni.com/public.nsf/websearch/D8E97E95D59AC17086257B3600508823?OpenDocument" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://digital.ni.com/public.nsf/allkb/548965C170D6AA2586257BD3004B146B?OpenDocument" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2013-05-20T00:00:00", "descriptions": [ { "lang": "en", "value": "An ActiveX control in NationalInstruments.Help2.dll in National Instruments NI .NET Class Library Help, as used in Measurement Studio 2013 and earlier and other products, allows remote attackers to obtain sensitive information about the existence of registry keys via crafted (1) key-open or (2) key-close method calls." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2013-09-17T09:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://digital.ni.com/public.nsf/websearch/D8E97E95D59AC17086257B3600508823?OpenDocument" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://digital.ni.com/public.nsf/allkb/548965C170D6AA2586257BD3004B146B?OpenDocument" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2013-5024", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An ActiveX control in NationalInstruments.Help2.dll in National Instruments NI .NET Class Library Help, as used in Measurement Studio 2013 and earlier and other products, allows remote attackers to obtain sensitive information about the existence of registry keys via crafted (1) key-open or (2) key-close method calls." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://digital.ni.com/public.nsf/websearch/D8E97E95D59AC17086257B3600508823?OpenDocument", "refsource": "CONFIRM", "url": "http://digital.ni.com/public.nsf/websearch/D8E97E95D59AC17086257B3600508823?OpenDocument" }, { "name": "http://digital.ni.com/public.nsf/allkb/548965C170D6AA2586257BD3004B146B?OpenDocument", "refsource": "CONFIRM", "url": "http://digital.ni.com/public.nsf/allkb/548965C170D6AA2586257BD3004B146B?OpenDocument" }, { "name": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument", "refsource": "CONFIRM", "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2013-5024", "datePublished": "2013-08-06T18:00:00", "dateReserved": "2013-07-31T00:00:00", "dateUpdated": "2024-08-06T16:59:41.194Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2013-5023 (GCVE-0-2013-5023)
Vulnerability from cvelistv5
Published
2013-08-06 18:00
Modified
2024-08-06 16:59
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- n/a
Summary
The ActiveX controls in the HelpAsst component in NI Help Links in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allow remote attackers to cause a denial of service by triggering the display of local .chm files.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T16:59:41.216Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://digital.ni.com/public.nsf/allkb/E6BC4F119D49A97A86257BD3004FE019?OpenDocument" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://digital.ni.com/public.nsf/websearch/5C87A3AA7300868986257B3600501FE6?OpenDocument" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2013-05-20T00:00:00", "descriptions": [ { "lang": "en", "value": "The ActiveX controls in the HelpAsst component in NI Help Links in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allow remote attackers to cause a denial of service by triggering the display of local .chm files." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2013-09-17T09:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://digital.ni.com/public.nsf/allkb/E6BC4F119D49A97A86257BD3004FE019?OpenDocument" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://digital.ni.com/public.nsf/websearch/5C87A3AA7300868986257B3600501FE6?OpenDocument" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2013-5023", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The ActiveX controls in the HelpAsst component in NI Help Links in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allow remote attackers to cause a denial of service by triggering the display of local .chm files." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://digital.ni.com/public.nsf/allkb/E6BC4F119D49A97A86257BD3004FE019?OpenDocument", "refsource": "CONFIRM", "url": "http://digital.ni.com/public.nsf/allkb/E6BC4F119D49A97A86257BD3004FE019?OpenDocument" }, { "name": "http://digital.ni.com/public.nsf/websearch/5C87A3AA7300868986257B3600501FE6?OpenDocument", "refsource": "CONFIRM", "url": "http://digital.ni.com/public.nsf/websearch/5C87A3AA7300868986257B3600501FE6?OpenDocument" }, { "name": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument", "refsource": "CONFIRM", "url": "http://digital.ni.com/public.nsf/websearch/507DEC9DA57A708186257B3600512623?OpenDocument" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2013-5023", "datePublished": "2013-08-06T18:00:00", "dateReserved": "2013-07-31T00:00:00", "dateUpdated": "2024-08-06T16:59:41.216Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }