Vulnerabilites related to mitsubishielectric - melsec-q
CVE-2020-5594 (GCVE-0-2020-5594)
Vulnerability from cvelistv5
Published
2020-06-23 07:35
Modified
2024-08-04 08:30
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- Cleartext Transmission of Sensitive Information
Summary
Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors.
References
► | URL | Tags | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
Mitsubishi Electric Corporation | MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules |
Version: all versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:30:24.558Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules", "vendor": "Mitsubishi Electric Corporation", "versions": [ { "status": "affected", "version": "all versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors." } ], "problemTypes": [ { "descriptions": [ { "description": "Cleartext Transmission of Sensitive Information", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-23T07:35:23", "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "shortName": "jpcert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vultures@jpcert.or.jp", "ID": "CVE-2020-5594", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules", "version": { "version_data": [ { "version_value": "all versions" } ] } } ] }, "vendor_name": "Mitsubishi Electric Corporation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Cleartext Transmission of Sensitive Information" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf" }, { "name": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf" }, { "name": "https://jvn.jp/en/vu/JVNVU91424496/index.html", "refsource": "MISC", "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce", "assignerShortName": "jpcert", "cveId": "CVE-2020-5594", "datePublished": "2020-06-23T07:35:23", "dateReserved": "2020-01-06T00:00:00", "dateUpdated": "2024-08-04T08:30:24.558Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2020-06-23 08:15
Modified
2024-11-21 05:34
Severity ?
Summary
Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F2A20BD-77FE-42A3-9AC6-597470CD1212", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-r:-:*:*:*:*:*:*:*", "matchCriteriaId": "71CC1A84-A51D-4E56-BA7A-9C1D21DDF8D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:melsec_iq-f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1644AECC-4A04-4209-9654-668D6B3B093B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:melsec_iq-f:-:*:*:*:*:*:*:*", "matchCriteriaId": "175AA161-6775-4715-85A2-4AD426D131F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:melsec-q_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1047B633-7FE4-47C2-846F-5878DA5D3038", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:melsec-q:-:*:*:*:*:*:*:*", "matchCriteriaId": "418EA7F6-FB8D-4192-8BEC-E34BBF98400A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:melsec-l_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93701E98-1A2C-45EE-933F-2FA9D803A875", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:melsec-l:-:*:*:*:*:*:*:*", "matchCriteriaId": "FCADAD32-6840-45C7-94E1-DD7BE0A59417", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:melsec-fx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "25DCC54F-CA89-41BC-8C3F-89084911956D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:melsec-fx:-:*:*:*:*:*:*:*", "matchCriteriaId": "455C03F1-8A83-493D-9DAD-F7D0950105AF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L, and FX series CPU modules all versions contain a vulnerability that allows cleartext transmission of sensitive information between CPU modules and GX Works3 and/or GX Works2 via unspecified vectors." }, { "lang": "es", "value": "Todos los m\u00f3dulos de CPU de las series Mitsubishi Electric MELSEC iQ-R, iQ-F, Q, L y FX, contienen una vulnerabilidad que permite la transmisi\u00f3n de informaci\u00f3n confidencial entre m\u00f3dulos de CPU y GX Works3 y/o GX Works2 por medio de vectores no especificados" } ], "id": "CVE-2020-5594", "lastModified": "2024-11-21T05:34:19.893", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-23T08:15:10.487", "references": [ { "source": "vultures@jpcert.or.jp", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html" }, { "source": "vultures@jpcert.or.jp", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf" }, { "source": "vultures@jpcert.or.jp", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/en/vu/JVNVU91424496/index.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-003.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-003_en.pdf" } ], "sourceIdentifier": "vultures@jpcert.or.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-319" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }