Vulnerabilites related to schneider-electric - modbus
Vulnerability from fkie_nvd
Published
2017-06-30 03:29
Modified
2025-04-20 01:37
Severity ?
Summary
An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:modbus_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDF59532-F8A6-4EFC-9B65-7FE1C37B6222",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:modbus:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B98D3886-8E25-44A6-9BA0-97274DBE4D39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema de omisi\u00f3n de autenticaci\u00f3n por captura por reproducci\u00f3n en el protocolo Modicon Modbus, de Schneider Electric. Se transmite informaci\u00f3n sensible en texto claro en el protocolo Modicon Modbus, lo que podr\u00eda permitir que un atacante reproduzca los siguientes comandos: run, stop, upload y download."
    }
  ],
  "id": "CVE-2017-6034",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-06-30T03:29:00.453",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/97562"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/97562"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-294"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2017-06-30 03:29
Modified
2025-04-20 01:37
Summary
A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:modbus_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDF59532-F8A6-4EFC-9B65-7FE1C37B6222",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:modbus:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B98D3886-8E25-44A6-9BA0-97274DBE4D39",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks."
    },
    {
      "lang": "es",
      "value": "Se ha descubierto un problema de violaci\u00f3n de principios de dise\u00f1o seguro en el protocolo Modicon Modbus, de Schneider Electric. El protocolo Modicon Modbus tiene una debilidad relacionada con la sesi\u00f3n que lo hace susceptible a ataques de fuerza bruta."
    }
  ],
  "id": "CVE-2017-6032",
  "lastModified": "2025-04-20T01:37:25.860",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2017-06-30T03:29:00.423",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/97562"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/97562"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-657"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-358"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2017-6032 (GCVE-0-2017-6032)
Vulnerability from cvelistv5
Published
2017-06-30 02:35
Modified
2024-08-05 15:18
Severity ?
CWE
Summary
A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks.
References
Impacted products
Vendor Product Version
n/a Schneider Electric Modicon Modbus Protocol Version: Schneider Electric Modicon Modbus Protocol
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:18:49.406Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
          },
          {
            "name": "97562",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/97562"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Schneider Electric Modicon Modbus Protocol",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Schneider Electric Modicon Modbus Protocol"
            }
          ]
        }
      ],
      "datePublic": "2017-06-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-657",
              "description": "CWE-657",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-06-30T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
        },
        {
          "name": "97562",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/97562"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-6032",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Schneider Electric Modicon Modbus Protocol",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Schneider Electric Modicon Modbus Protocol"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-657"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
            },
            {
              "name": "97562",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/97562"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-6032",
    "datePublished": "2017-06-30T02:35:00",
    "dateReserved": "2017-02-16T00:00:00",
    "dateUpdated": "2024-08-05T15:18:49.406Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-6034 (GCVE-0-2017-6034)
Vulnerability from cvelistv5
Published
2017-06-30 02:35
Modified
2024-08-05 15:18
Severity ?
CWE
Summary
An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download.
References
Impacted products
Vendor Product Version
n/a Schneider Electric Modicon Modbus Protocol Version: Schneider Electric Modicon Modbus Protocol
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:18:49.398Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
          },
          {
            "name": "97562",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/97562"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Schneider Electric Modicon Modbus Protocol",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Schneider Electric Modicon Modbus Protocol"
            }
          ]
        }
      ],
      "datePublic": "2017-06-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-294",
              "description": "CWE-294",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-06-30T09:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
        },
        {
          "name": "97562",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/97562"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-6034",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Schneider Electric Modicon Modbus Protocol",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Schneider Electric Modicon Modbus Protocol"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Authentication Bypass by Capture-Replay issue was discovered in Schneider Electric Modicon Modbus Protocol. Sensitive information is transmitted in cleartext in the Modicon Modbus protocol, which may allow an attacker to replay the following commands: run, stop, upload, and download."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-294"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-101-01"
            },
            {
              "name": "97562",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/97562"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-6034",
    "datePublished": "2017-06-30T02:35:00",
    "dateReserved": "2017-02-16T00:00:00",
    "dateUpdated": "2024-08-05T15:18:49.398Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}