Vulnerabilites related to totolink - n300rh-v3
CVE-2020-25499 (GCVE-0-2020-25499)
Vulnerability from cvelistv5
Published
2020-12-09 20:30
Modified
2024-08-04 15:33
Severity ?
CWE
  • n/a
Summary
TOTOLINK A3002RU-V2.0.0 B20190814.1034 allows authenticated remote users to modify the system's 'Run Command'. An attacker can use this functionality to execute arbitrary OS commands on the router.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:33:05.689Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.totolink.net/home/index/newsss/id/196.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2020-10-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "TOTOLINK A3002RU-V2.0.0 B20190814.1034 allows authenticated remote users to modify the system\u0027s \u0027Run Command\u0027. An attacker can use this functionality to execute arbitrary OS commands on the router."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-09T20:30:55",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.totolink.net/home/index/newsss/id/196.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-25499",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "TOTOLINK A3002RU-V2.0.0 B20190814.1034 allows authenticated remote users to modify the system\u0027s \u0027Run Command\u0027. An attacker can use this functionality to execute arbitrary OS commands on the router."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.totolink.net/home/index/newsss/id/196.html",
              "refsource": "CONFIRM",
              "url": "https://www.totolink.net/home/index/newsss/id/196.html"
            },
            {
              "name": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2",
              "refsource": "MISC",
              "url": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-25499",
    "datePublished": "2020-12-09T20:30:55",
    "dateReserved": "2020-09-14T00:00:00",
    "dateUpdated": "2024-08-04T15:33:05.689Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2015-9550 (GCVE-0-2015-9550)
Vulnerability from cvelistv5
Published
2020-11-24 21:01
Modified
2024-08-06 08:51
Severity ?
CWE
  • n/a
Summary
An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. By sending a specific hel,xasf packet to the WAN interface, it is possible to open the web management interface on the WAN interface.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T08:51:05.311Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. By sending a specific hel,xasf packet to the WAN interface, it is possible to open the web management interface on the WAN interface."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-11-24T21:01:41",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2015-9550",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. By sending a specific hel,xasf packet to the WAN interface, it is possible to open the web management interface on the WAN interface."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html",
              "refsource": "MISC",
              "url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2015-9550",
    "datePublished": "2020-11-24T21:01:41",
    "dateReserved": "2020-11-24T00:00:00",
    "dateUpdated": "2024-08-06T08:51:05.311Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2015-9551 (GCVE-0-2015-9551)
Vulnerability from cvelistv5
Published
2020-11-24 21:01
Modified
2024-08-06 08:58
Severity ?
CWE
  • n/a
Summary
An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T08:58:24.569Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-11-24T21:01:27",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2015-9551",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html",
              "refsource": "MISC",
              "url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2015-9551",
    "datePublished": "2020-11-24T21:01:27",
    "dateReserved": "2020-11-24T00:00:00",
    "dateUpdated": "2024-08-06T08:58:24.569Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Vulnerability from fkie_nvd
Published
2020-11-24 21:15
Modified
2024-11-21 02:40
Summary
An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. By sending a specific hel,xasf packet to the WAN interface, it is possible to open the web management interface on the WAN interface.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:a850r-v1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DDFAFC-3538-45B5-AB36-3895F16BD764",
              "versionEndExcluding": "1.0.1-b20150707.1612",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:a850r-v1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "74953383-D90B-4B54-B02B-617BCF8010E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:f1-v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FBC80064-797F-487C-99C1-D8F4981D4990",
              "versionEndExcluding": "2.1.1-b20150708.1646",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:f1-v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "611785C4-C11E-4F73-BB8B-DFEE66F3FB6A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:f2-v1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6844CA14-C66E-4E6B-ABC6-1D083EEF9D82",
              "versionEndExcluding": "2.1.0-b20150320.1611",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:f2-v1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B693CF6C-A0C7-42DD-AA82-36887087BCED",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n150rt-v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "572842ED-48C4-4D90-B107-EF6DBFC19585",
              "versionEndExcluding": "2.1.1-b20150708.1548",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n150rt-v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0251C2F8-9BCC-4B34-8747-09CA39E6CE7C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n151rt-v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7E9FE34-8EBD-47BD-AD90-F07381E0C06A",
              "versionEndExcluding": "1.1-b20150708.1559",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n151rt-v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00922E42-2177-4214-8A1E-8FEB6BDE2869",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n300rh-v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D436BD3-1C39-49CE-BC15-50C890F58931",
              "versionEndExcluding": "2.0.1-b20150708.1625",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n300rh-v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0ECED9E-930D-4061-ABB4-CC2DD2346BBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n300rh-v3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BC6C344-01DD-4EB6-B1A3-60B782E81BA4",
              "versionEndExcluding": "3.0.0-b20150331.0858",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n300rh-v3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "058F675A-3C67-4B73-808C-8C65D7D65C12",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n300rt-v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "74971352-B072-4A9A-B07E-4E92F35C716A",
              "versionEndExcluding": "2.1.1-b20150708.1613",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n300rt-v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4637323A-10A8-4841-BC49-3EF2894C5F86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. By sending a specific hel,xasf packet to the WAN interface, it is possible to open the web management interface on the WAN interface."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 un problema en los dispositivos TOTOLINK A850R-V1 versiones hasta 1.0.1-B20150707.1612 y F1-V2 versiones hasta 1.1-B20150708.1646.\u0026#xa0;Mediante el env\u00edo de un paquete hel,xasf espec\u00edfico hacia la interfaz WAN, es posible abrir la interfaz de administraci\u00f3n web sobre la interfaz WAN"
    }
  ],
  "id": "CVE-2015-9550",
  "lastModified": "2024-11-21T02:40:54.460",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-11-24T21:15:11.353",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-668"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-12-09 21:15
Modified
2024-11-21 05:18
Summary
TOTOLINK A3002RU-V2.0.0 B20190814.1034 allows authenticated remote users to modify the system's 'Run Command'. An attacker can use this functionality to execute arbitrary OS commands on the router.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:a3002r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5AA5F65-A666-4A60-91D7-EABF708170EB",
              "versionEndExcluding": "1.1.1-b20200824.0128",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:a3002r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CBBBC48-8918-4D59-8059-285404AE7716",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:a3002ru-v1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E0F90C0-EC26-4F57-8624-0EB1057302D3",
              "versionEndExcluding": "3.4.0-b20201030.1754",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:a3002ru-v1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5CD41BE-CDB7-4837-82D1-6C0B66037CD3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:a3002ru-v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C4A5C22-01E2-429D-867C-9351822F20E6",
              "versionEndExcluding": "2.1.1-b20200911.1756",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:a3002ru-v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "720DB583-0A2B-4538-88A4-F90D32FC67EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:a702r-v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56024E88-14F8-485D-B222-0DBFBF8AEBBE",
              "versionEndExcluding": "1.0.0-b20201028.1743",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:a702r-v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4793791A-832B-4CE9-904A-CD2C42A1B2CC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:a702r-v3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E956F23E-F4F0-42FE-B53A-62F13E6EA7DD",
              "versionEndExcluding": "1.0.0-b20201103.1713",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:a702r-v3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4402B575-14BC-441C-BF49-A5E0275650D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n100re-v3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C533E019-DF7C-4AF1-8530-03E879AE49BD",
              "versionEndExcluding": "3.4.0-b20201030.0926",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n100re-v3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EAEB0A7-37C9-418C-9658-FA321594F9BB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n150rt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "43BF4C58-31C2-4AE7-8858-2C5C4BED4A74",
              "versionEndExcluding": "3.4.0-b20201030.1142",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n150rt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7525BE05-F394-4ED7-B7A6-F9005EDE90D7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n200re-v3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E2C8202-4F82-4A74-9919-0E8C4A97A113",
              "versionEndExcluding": "3.4.0-b20201029.1811",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n200re-v3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BA1AA4B-5CFA-4200-B132-75D8B8981396",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n200re-v4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E9DDDBB-F4C0-417E-BB39-2324D4A25EEC",
              "versionEndExcluding": "4.0.0-b20200805.1507",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n200re-v4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BFDB792-2EB3-4045-A5A8-A57B72B8368E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n210re_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56450DF0-5C38-4D19-9E50-222BBB1C0329",
              "versionEndExcluding": "1.0.0-b20201030.2030",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n210re:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "93445A4F-C8AA-4A55-80A7-41CAAB588A99",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n300rh-v3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F391AC8-AEF5-4E97-97AC-58ECFCFDD626",
              "versionEndExcluding": "3.2.4-b20201029.1838",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n300rh-v3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "058F675A-3C67-4B73-808C-8C65D7D65C12",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n300rt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6A01759-06EE-40F0-AE11-8FFFAB3074F6",
              "versionEndExcluding": "3.4.0-b20201026.2033",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n300rt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0581174-E6B1-4E3D-8384-7852EC53FC14",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n302r_plus_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2DCBB0C-FEB1-45B4-BA07-F73F08BCBE47",
              "versionEndExcluding": "3.4.0-b20201028.2224",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n302r_plus:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C06D3FD9-582D-4E26-9928-DF3609EF3373",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "TOTOLINK A3002RU-V2.0.0 B20190814.1034 allows authenticated remote users to modify the system\u0027s \u0027Run Command\u0027. An attacker can use this functionality to execute arbitrary OS commands on the router."
    },
    {
      "lang": "es",
      "value": "TOTOLINK A3002RU-V2.0.0 versi\u00f3n B20190814.1034, permite a usuarios remotos autenticados modificar el \"Run Command\" del sistema.\u0026#xa0;Un atacante puede usar esta funcionalidad para ejecutar comandos arbitrarios del sistema operativo en el enrutador"
    }
  ],
  "id": "CVE-2020-25499",
  "lastModified": "2024-11-21T05:18:04.130",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-12-09T21:15:15.477",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.totolink.net/home/index/newsss/id/196.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/kdoos/Vulnerabilities/blob/main/RCE_TOTOLINK-A3002RU-V2"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.totolink.net/home/index/newsss/id/196.html"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        },
        {
          "lang": "en",
          "value": "CWE-862"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-11-24 21:15
Modified
2024-11-21 02:40
Severity ?
Summary
An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:a850r-v1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DDFAFC-3538-45B5-AB36-3895F16BD764",
              "versionEndExcluding": "1.0.1-b20150707.1612",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:a850r-v1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "74953383-D90B-4B54-B02B-617BCF8010E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:f1-v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FBC80064-797F-487C-99C1-D8F4981D4990",
              "versionEndExcluding": "2.1.1-b20150708.1646",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:f1-v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "611785C4-C11E-4F73-BB8B-DFEE66F3FB6A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:f2-v1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6844CA14-C66E-4E6B-ABC6-1D083EEF9D82",
              "versionEndExcluding": "2.1.0-b20150320.1611",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:f2-v1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B693CF6C-A0C7-42DD-AA82-36887087BCED",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n150rt-v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "572842ED-48C4-4D90-B107-EF6DBFC19585",
              "versionEndExcluding": "2.1.1-b20150708.1548",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n150rt-v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0251C2F8-9BCC-4B34-8747-09CA39E6CE7C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n151rt-v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7E9FE34-8EBD-47BD-AD90-F07381E0C06A",
              "versionEndExcluding": "1.1-b20150708.1559",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n151rt-v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00922E42-2177-4214-8A1E-8FEB6BDE2869",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n300rh-v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D436BD3-1C39-49CE-BC15-50C890F58931",
              "versionEndExcluding": "2.0.1-b20150708.1625",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n300rh-v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0ECED9E-930D-4061-ABB4-CC2DD2346BBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n300rh-v3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BC6C344-01DD-4EB6-B1A3-60B782E81BA4",
              "versionEndExcluding": "3.0.0-b20150331.0858",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n300rh-v3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "058F675A-3C67-4B73-808C-8C65D7D65C12",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:totolink:n300rt-v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "74971352-B072-4A9A-B07E-4E92F35C716A",
              "versionEndExcluding": "2.1.1-b20150708.1613",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:totolink:n300rt-v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4637323A-10A8-4841-BC49-3EF2894C5F86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered on TOTOLINK A850R-V1 through 1.0.1-B20150707.1612 and F1-V2 through 1.1-B20150708.1646 devices. There is Remote Code Execution in the management interface via the formSysCmd sysCmd parameter."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 un problema en los dispositivos TOTOLINK A850R-V1 versiones hasta 1.0.1-B20150707.1612 y F1-V2 versiones hasta 1.1-B20150708.1646.\u0026#xa0;Se presenta una Ejecuci\u00f3n de C\u00f3digo Remota en la interfaz de administraci\u00f3n por medio del par\u00e1metro formSysCmd sysCmd"
    }
  ],
  "id": "CVE-2015-9551",
  "lastModified": "2024-11-21T02:40:54.613",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-11-24T21:15:11.417",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://pierrekim.github.io/blog/2015-07-16-backdoor-and-RCE-found-in-8-TOTOLINK-products.html"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}