Vulnerabilites related to siemens - nucleus_readystart
Vulnerability from fkie_nvd
Published
2021-02-09 18:15
Modified
2024-11-21 05:22
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus ReadyStart V3 (All versions < V2012.12), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). Initial Sequence Numbers (ISNs) for TCP connections are derived from an insufficiently random source. As a result, the ISN of current and future TCP connections could be predictable. An attacker could hijack existing sessions or spoof future ones.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EC45D63-0FB7-4995-AF45-B41F6EF6A9E2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7AA3D291-7974-459E-8629-82EEE9222881",
              "versionEndExcluding": "5.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "07DAF9C3-B56A-4F40-B90B-D0DE96869A44",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:pluscontrol_1st_gen:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A79FC04-B321-46B2-A363-5B964032856E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:nucleus_readystart:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C4577E0-9A51-45E6-8B07-C4AB711F2801",
              "versionEndExcluding": "2012.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:arm:arm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7533C487-7AD2-4B6E-B4B1-9D82BBF83CF3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:mips:mips:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "838DEE07-4C15-4107-90B0-BEC2E081B3F0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:powerpc_project:powerpc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA4BF0DF-EE3D-4649-B7EE-F30D6473BE0B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions \u003c V5.2), Nucleus ReadyStart V3 (All versions \u003c V2012.12), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). Initial Sequence Numbers (ISNs) for TCP connections are derived from an insufficiently random source. As a result, the ISN of current and future TCP connections could be predictable. An attacker could hijack existing sessions or spoof future ones."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Capital VSTAR (Todas las versiones), Nucleus NET (Todas las versiones anteriores a V5.2), Nucleus ReadyStart V3 (Todas las versiones anteriores a V2012.12), Nucleus Source Code (Todas las versiones), PLUSCONTROL 1st Gen (Todas las versiones). Los n\u00fameros de secuencia iniciales (ISN) para las conexiones TCP se derivan de una fuente insuficientemente aleatoria. Como resultado, el ISN de las conexiones TCP actuales y futuras podr\u00eda ser predecible. Un atacante podr\u00eda secuestrar las sesiones existentes o falsificar las futuras"
    }
  ],
  "id": "CVE-2020-28388",
  "lastModified": "2024-11-21T05:22:42.130",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.5,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-02-09T18:15:34.590",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-362164.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436469.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-362164.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436469.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-342"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-01-16 16:15
Modified
2025-06-10 16:15
Summary
A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions < V2.8.2), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8.2 < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8.2 < V2.8.19), Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Desigo PXC00-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC00-U (All versions >= V2.3x and < V6.00.327), Desigo PXC001-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC100-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC12-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC128-U (All versions >= V2.3x and < V6.00.327), Desigo PXC200-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC22-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC50-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC64-U (All versions >= V2.3x and < V6.00.327), Desigo PXM20-E (All versions >= V2.3 < V6.0.327), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All versions < V0.3.0.330), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EC45D63-0FB7-4995-AF45-B41F6EF6A9E2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A987CFB-4A41-4F82-8C7F-31DE8F0650DE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:nucleus_readystart:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE16530A-D354-43A0-A2C7-DB312646C69C",
              "versionEndExcluding": "2017.02.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:nucleus_safetycert:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7ED0DBA9-FFB1-407C-8429-BCD24DCB33FF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "07DAF9C3-B56A-4F40-B90B-D0DE96869A44",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:nucleus_rtos:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "485540AD-9966-49B0-AC24-BEFE81C4D4E3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:apogee_modular_equiment_controller_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8240E52-8D3B-40AF-944F-5AD993279B07",
              "versionEndExcluding": "2.8.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:apogee_modular_equiment_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7945BF7D-AB3A-4285-9C58-D56149ADFC15",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "217F3116-5F09-4D60-BD65-8960401434AF",
              "versionEndExcluding": "2.8.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5F978E7-3DD9-4948-BFFB-E7273003477B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:apogee_pxc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1206DD28-16D8-4F71-BABA-FDCE3CD9A91D",
              "versionEndIncluding": "2.8.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:apogee_pxc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B73DAA70-4CFB-4E63-ADC7-EC8A93E0BBBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigo_pxc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "741E43A3-43D1-4ECF-915A-92E035FF8903",
              "versionStartIncluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigo_pxc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8ED54EF-1BAB-465B-A4D1-E779F63CF4F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigo_pxm20_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "669CAA1B-9E47-4331-8E1F-92D562F3CFF2",
              "versionStartIncluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigo_pxm20:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "408DD298-FAC6-45E6-BF04-832C16B13927",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simotics_connect_400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E01F98E1-441B-48CC-90FC-E9391D65844E",
              "versionEndIncluding": "0.3.0.95",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simotics_connect_400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "48BFF9EF-D1C1-4107-8D1E-51315C03FFF0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:talon_tc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EC32195-D888-4A8B-AC77-D0C98A83E88A",
              "versionStartIncluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:talon_tc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F30FF737-174E-4760-A454-1DD174B4C966",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigo_pxc00-e.d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC441789-6954-48E7-9A42-1A2993C93066",
              "versionEndExcluding": "6.00.327",
              "versionStartIncluding": "2.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigo_pxc00-e.d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1727849-2FD8-40A2-91D3-E0C9662B45BC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigo_pxc00-u_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E396F519-8055-486E-A2DB-F9E6DD5B1E2D",
              "versionEndExcluding": "6.00.327",
              "versionStartIncluding": "2.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigo_pxc00-u:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD39D011-8AE2-46FE-9207-C110E2FBC07C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigo_pxc001-e.d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8ACD8296-AC32-42CE-8B8D-A3F6FFD7A869",
              "versionEndExcluding": "6.00.327",
              "versionStartIncluding": "2.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigo_pxc001-e.d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCC50C13-FA05-4459-BA1E-482D886B842B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigo_pxc12-e.d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6B65BC2-7D65-4216-8B3A-773825297CFE",
              "versionEndExcluding": "6.00.327",
              "versionStartIncluding": "2.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigo_pxc12-e.d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DDA404C0-FD6D-47CC-950C-E5DCC993C8E6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigo_pxc22-e.d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C4CDD0E-FAB0-4F44-96AB-9ADDEFB456EC",
              "versionEndExcluding": "6.00.327",
              "versionStartIncluding": "2.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigo_pxc22-e.d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A4D84CE-07AB-4305-9C48-54392772D4EB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigo_pxc22.1-e.d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5B66D45-3F60-469D-ADF6-ECB02567970C",
              "versionEndExcluding": "6.00.327",
              "versionStartIncluding": "2.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigo_pxc22.1-e.d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E67F374-BF75-4334-A6D5-AB570E0A70D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigo_pxc36.1-e.d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1C11C33-5757-44C5-9CC2-4BC3F287DD75",
              "versionEndExcluding": "6.00.327",
              "versionStartIncluding": "2.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigo_pxc36.1-e.d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CA7EF94-2EE2-4B53-A544-F675306DF84F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigopxc50-e.d_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "93AC0E5C-5A08-43E4-88E5-7681755126F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigopxc50-e.d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F2D5B24-63B5-41C8-B20B-98699C4979F9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigopxc64-u_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BCB6399E-E7BD-4469-8166-B03B74E421BE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigopxc64-u:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "980885C3-B98A-4AC9-AB86-A8BBFF23F37D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigopxc100-e.d_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9118355-1BBC-43C7-9923-0F8FAEA70D40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigopxc100-e.d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "93E5FEC8-EAE9-4235-91EE-FE68CCE19C43",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigopxc128-u_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD7B8DC6-A346-4D4B-B6F6-9831E7D1F999",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigopxc128-u:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF17316C-DDD6-42F9-A147-6729632D9902",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigopxc200-e.d_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED820905-73EA-41F8-A2C5-17CD6BCF1707",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigopxc200-e.d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E05F84E0-808C-4C40-9D50-9BE0117B791E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:desigopxm20-e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2EFE56A4-408F-4807-A76D-B54AD9C85C28",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:desigopxm20-e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "162C32E8-05CD-40A2-AB56-17CE4D85842F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions \u003c V2.8.2), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions \u003e= V2.8.2 \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions \u003e= V2.8.2 \u003c V2.8.19), Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), Desigo PXC00-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC00-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXC001-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC100-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC12-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC128-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXC200-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC22-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC22.1-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC36.1-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC50-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC64-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXM20-E (All versions \u003e= V2.3 \u003c V6.0.327), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.3.0.330), TALON TC Compact (BACnet) (All versions \u003c V3.5.3), TALON TC Modular (BACnet) (All versions \u003c V3.5.3). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en APOGEE MEC/MBC/PXC (P2) (Todas las versiones anteriores a V2.8.2), APOGEE PXC Series (BACnet) (Todas las versiones anteriores a V3.5.3), APOGEE PXC Series (P2) (Todas las versiones posteriores o iguales a V2. 8.2 y anteriores a V2.8.19), Desigo PXC00-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC00-U (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC001-E. D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC100-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC12-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00. 327), Desigo PXC128-U (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC200-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC22-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00. 327), Desigo PXC22.1-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC36.1-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC50-E. D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC64-U (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXM20-E (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00. 327), Nucleus NET (Todas las versiones), Nucleus RTOS (Todas las versiones), Nucleus ReadyStart para ARM, MIPS y PPC (Todas las versiones anteriores a V2017.02.2 con parche \"Nucleus 2017.02. 02 Nucleus NET Patch\"), Nucleus SafetyCert (Todas las versiones), Nucleus Source Code (Todas las versiones), SIMOTICS CONNECT 400 (Todas las versiones anteriores a V0.3.0.330), TALON TC Series (BACnet) (Todas las versiones anteriores a V3.5.3), VSTAR (Todas las versiones). Al enviar paquetes DHCP especialmente dise\u00f1ados a un dispositivo donde el cliente DHCP est\u00e1 habilitado, un atacante podr\u00eda cambiar la direcci\u00f3n IP del dispositivo a un valor no v\u00e1lido. La vulnerabilidad podr\u00eda afectar a la disponibilidad e integridad del dispositivo. Se requiere acceso a la red adyacente, pero no se necesita autenticaci\u00f3n ni interacci\u00f3n del usuario para realizar un ataque"
    }
  ],
  "id": "CVE-2019-13939",
  "lastModified": "2025-06-10T16:15:33.853",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:A/AC:L/Au:N/C:N/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 4.2,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 4.2,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "ADJACENT",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "NONE",
          "vulnIntegrityImpact": "LOW",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2020-01-16T16:15:16.277",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-162506.html"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-434032.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-105-06"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-162506.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-434032.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-105-06"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-04-22 21:15
Modified
2025-03-11 10:15
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:capital_vstar:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EEBF34F7-F37A-4FD1-957E-B2E5DEE7A778",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A987CFB-4A41-4F82-8C7F-31DE8F0650DE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:nucleus_readystart:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A5FA7B8-2F94-4762-ADBF-71C0F37231AB",
              "versionEndExcluding": "4.1.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:nucleus_source_code:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "53A38C64-612A-4BC5-83D5-D3FA1C90E0F7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:nucleus_readystart:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F768DEFE-CE6F-4210-B728-9C4CA2AF03FE",
              "versionEndExcluding": "2017.02.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Capital VSTAR (Versiones que incluyen la pila IPv6 afectada), Nucleus NET (Todas las versiones), Nucleus ReadyStart V3 (Todas las versiones anteriores a V2017.02.4), Nucleus ReadyStart V4 (Todas las versiones anteriores a V4.1.0), Nucleus Source Code (Versiones que incluyen la pila IPv6 afectada). La funci\u00f3n que procesa las cabeceras de IPv6 no comprueba las longitudes de las opciones de las cabeceras de extensi\u00f3n, lo que permite a los atacantes poner esta funci\u00f3n en un bucle infinito con valores de longitud manipulados"
    }
  ],
  "id": "CVE-2021-25663",
  "lastModified": "2025-03-11T10:15:13.240",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2021-04-22T21:15:09.957",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-248289.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-248289.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-05"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-835"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-835"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2020-28388 (GCVE-0-2020-28388)
Vulnerability from cvelistv5
Published
2021-02-09 00:00
Modified
2024-08-04 16:33
CWE
  • CWE-342 - Predictable Exact Value from Previous Values
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus ReadyStart V3 (All versions < V2012.12), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). Initial Sequence Numbers (ISNs) for TCP connections are derived from an insufficiently random source. As a result, the ISN of current and future TCP connections could be predictable. An attacker could hijack existing sessions or spoof future ones.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:58.999Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-362164.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436469.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.20"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2012.12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "PLUSCONTROL 1st Gen",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.5.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions \u003c V5.2), Nucleus ReadyStart V3 (All versions \u003c V2012.12), Nucleus Source Code (All versions), PLUSCONTROL 1st Gen (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). Initial Sequence Numbers (ISNs) for TCP connections are derived from an insufficiently random source. As a result, the ISN of current and future TCP connections could be predictable. An attacker could hijack existing sessions or spoof future ones."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-342",
              "description": "CWE-342: Predictable Exact Value from Previous Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-08T09:20:06.562Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-362164.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-436469.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28388",
    "datePublished": "2021-02-09T00:00:00",
    "dateReserved": "2020-11-10T00:00:00",
    "dateUpdated": "2024-08-04T16:33:58.999Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-13939 (GCVE-0-2019-13939)
Vulnerability from cvelistv5
Published
2020-01-16 15:35
Modified
2025-06-10 15:17
CWE
  • CWE-20 - Improper Input Validation
Summary
A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions < V2.8.2), APOGEE PXC Compact (BACnet) (All versions < V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions >= V2.8.2 < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions >= V2.8.2 < V2.8.19), Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Desigo PXC00-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC00-U (All versions >= V2.3x and < V6.00.327), Desigo PXC001-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC100-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC12-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC128-U (All versions >= V2.3x and < V6.00.327), Desigo PXC200-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC22-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC50-E.D (All versions >= V2.3 < V6.0.327), Desigo PXC64-U (All versions >= V2.3x and < V6.00.327), Desigo PXM20-E (All versions >= V2.3 < V6.0.327), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All versions < V0.3.0.330), TALON TC Compact (BACnet) (All versions < V3.5.3), TALON TC Modular (BACnet) (All versions < V3.5.3). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value.
Impacted products
Vendor Product Version
Siemens APOGEE MEC/MBC/PXC (P2) Version: All versions < V2.8.2
Create a notification for this product.
   Siemens APOGEE PXC Compact (BACnet) Version: 0   < V3.5.3
Create a notification for this product.
   Siemens APOGEE PXC Compact (P2 Ethernet) Version: V2.8.2   < V2.8.19
Create a notification for this product.
   Siemens APOGEE PXC Modular (BACnet) Version: 0   < V3.5.3
Create a notification for this product.
   Siemens APOGEE PXC Modular (P2 Ethernet) Version: V2.8.2   < V2.8.19
Create a notification for this product.
   Siemens Capital Embedded AR Classic 431-422 Version: 0   < *
Create a notification for this product.
   Siemens Capital Embedded AR Classic R20-11 Version: 0   < V2303
Create a notification for this product.
   Siemens Desigo PXC00-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC00-U Version: All versions >= V2.3x and < V6.00.327
Create a notification for this product.
   Siemens Desigo PXC001-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC100-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC12-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC128-U Version: All versions >= V2.3x and < V6.00.327
Create a notification for this product.
   Siemens Desigo PXC200-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC22-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC22.1-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC36.1-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC50-E.D Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Desigo PXC64-U Version: All versions >= V2.3x and < V6.00.327
Create a notification for this product.
   Siemens Desigo PXM20-E Version: V2.3   < V6.0.327
Create a notification for this product.
   Siemens Nucleus NET Version: 0   < *
Create a notification for this product.
   Siemens Nucleus ReadyStart V3 Version: 0   < V2017.02.3
Create a notification for this product.
   Siemens Nucleus Source Code Version: 0   < *
Create a notification for this product.
   Siemens SIMOTICS CONNECT 400 Version: All versions < V0.3.0.330
Create a notification for this product.
   Siemens TALON TC Compact (BACnet) Version: 0   < V3.5.3
Create a notification for this product.
   Siemens TALON TC Modular (BACnet) Version: 0   < V3.5.3
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:05:43.738Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-105-06"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-434032.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-162506.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "APOGEE MEC/MBC/PXC (P2)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Compact (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.8.19",
              "status": "affected",
              "version": "V2.8.2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "APOGEE PXC Modular (P2 Ethernet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.8.19",
              "status": "affected",
              "version": "V2.8.2",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC00-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC00-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3x and \u003c V6.00.327"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC001-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC100-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC12-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC128-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3x and \u003c V6.00.327"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC200-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC22-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC22.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC36.1-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC50-E.D",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXC64-U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.3x and \u003c V6.00.327"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Desigo PXM20-E",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.327",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2017.02.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTICS CONNECT 400",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V0.3.0.330"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Compact (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TALON TC Modular (BACnet)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in APOGEE MEC/MBC/PXC (P2) (All versions \u003c V2.8.2), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Compact (P2 Ethernet) (All versions \u003e= V2.8.2 \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.3), APOGEE PXC Modular (P2 Ethernet) (All versions \u003e= V2.8.2 \u003c V2.8.19), Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), Desigo PXC00-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC00-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXC001-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC100-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC12-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC128-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXC200-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC22-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC22.1-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC36.1-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC50-E.D (All versions \u003e= V2.3 \u003c V6.0.327), Desigo PXC64-U (All versions \u003e= V2.3x and \u003c V6.00.327), Desigo PXM20-E (All versions \u003e= V2.3 \u003c V6.0.327), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.3), Nucleus Source Code (All versions), SIMOTICS CONNECT 400 (All versions \u003c V0.3.0.330), TALON TC Compact (BACnet) (All versions \u003c V3.5.3), TALON TC Modular (BACnet) (All versions \u003c V3.5.3). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-06-10T15:17:09.328Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-105-06"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-434032.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-162506.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-13939",
    "datePublished": "2020-01-16T15:35:24",
    "dateReserved": "2019-07-18T00:00:00",
    "dateUpdated": "2025-06-10T15:17:09.328Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-25663 (GCVE-0-2021-25663)
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2025-03-11 09:47
CWE
  • CWE-835 - Loop with Unreachable Exit Condition ('Infinite Loop')
Summary
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:11:27.118Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-05"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-248289.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic 431-422",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Capital Embedded AR Classic R20-11",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2303",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus NET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2017.02.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus ReadyStart V4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Nucleus Source Code",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus ReadyStart V4 (All versions \u003c V4.1.0), Nucleus Source Code (All versions including affected IPv6 stack). The function that processes IPv6 headers does not check the lengths of extension header options, allowing attackers to put this function into an infinite loop with crafted length values."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-835",
              "description": "CWE-835: Loop with Unreachable Exit Condition (\u0027Infinite Loop\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-11T09:47:33.806Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-05"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-248289.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-25663",
    "datePublished": "2021-04-22T20:42:20",
    "dateReserved": "2021-01-21T00:00:00",
    "dateUpdated": "2025-03-11T09:47:33.806Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}