Vulnerabilites related to abb - plant_connect
Vulnerability from fkie_nvd
Published
2019-11-26 00:15
Modified
2024-11-21 04:32
Severity ?
Summary
In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device.
References
▶ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://www.us-cert.gov/ics/advisories/icsa-19-318-05 | Not Applicable, Permissions Required, Third Party Advisory, US Government Resource | |
nvd@nist.gov | https://iotsecuritynews.com/abb-power-generation-information-manager-pgim-and-plant-connect/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-19-318-05 | Not Applicable, Permissions Required, Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
abb | plant_connect | * | |
abb | power_generation_information_manager | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:abb:plant_connect:*:*:*:*:*:*:*:*", "matchCriteriaId": "2376DF85-21FD-4C6A-A9C1-B1E5FF276866", "vulnerable": true }, { "criteria": "cpe:2.3:a:abb:power_generation_information_manager:*:*:*:*:*:*:*:*", "matchCriteriaId": "928D741D-5A9A-4EB9-827A-6DF53D7BBBD0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device." }, { "lang": "es", "value": "En todas las versiones de ABB Power Generation Information Manager (PGIM) y Plant Connect, el producto afectado es vulnerable a una omisi\u00f3n de autenticaci\u00f3n, lo que puede permitir a un atacante omitir remotamente la autenticaci\u00f3n y extraer credenciales del dispositivo afectado." } ], "id": "CVE-2019-18250", "lastModified": "2024-11-21T04:32:55.277", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-11-26T00:15:11.780", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Not Applicable", "Permissions Required", "Third Party Advisory", "US Government Resource" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-318-05" }, { "source": "nvd@nist.gov", "tags": [ "Third Party Advisory" ], "url": "https://iotsecuritynews.com/abb-power-generation-information-manager-pgim-and-plant-connect/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Not Applicable", "Permissions Required", "Third Party Advisory", "US Government Resource" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-318-05" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-288" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2019-18250 (GCVE-0-2019-18250)
Vulnerability from cvelistv5
Published
2019-11-25 23:13
Modified
2024-08-05 01:47
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-288 - AUTHENTICATION BYPASS USING AN ALTERNATE PATH OR CHANNEL
Summary
In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | ABB Power Generation Information Manager (PGIM) and Plant Connect All Versions |
Version: ABB Power Generation Information Manager (PGIM) and Plant Connect All Versions |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T01:47:14.143Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-318-05" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "ABB Power Generation Information Manager (PGIM) and Plant Connect All Versions", "vendor": "n/a", "versions": [ { "status": "affected", "version": "ABB Power Generation Information Manager (PGIM) and Plant Connect All Versions" } ] } ], "descriptions": [ { "lang": "en", "value": "In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-288", "description": "AUTHENTICATION BYPASS USING AN ALTERNATE PATH OR CHANNEL CWE-288", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-11-25T23:13:29", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-318-05" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2019-18250", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "ABB Power Generation Information Manager (PGIM) and Plant Connect All Versions", "version": { "version_data": [ { "version_value": "ABB Power Generation Information Manager (PGIM) and Plant Connect All Versions" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "AUTHENTICATION BYPASS USING AN ALTERNATE PATH OR CHANNEL CWE-288" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.us-cert.gov/ics/advisories/icsa-19-318-05", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-19-318-05" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2019-18250", "datePublished": "2019-11-25T23:13:29", "dateReserved": "2019-10-22T00:00:00", "dateUpdated": "2024-08-05T01:47:14.143Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }