Vulnerabilites related to siemens - q200_firmware
Vulnerability from fkie_nvd
Published
2023-06-13 09:15
Modified
2024-11-21 08:01
Severity ?
5.5 (Medium) - CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:L
4.8 (Medium) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N
Summary
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | q200_firmware | * | |
siemens | q200 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:q200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1D626C5-92BF-4C9B-9EF2-24347CF24491", "versionEndExcluding": "2.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:q200:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC2EA3F6-418C-49A4-B23C-E7BD56395466", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user." } ], "id": "CVE-2023-31238", "lastModified": "2024-11-21T08:01:41.260", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 1.3, "impactScore": 3.7, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 2.5, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-06-13T09:15:18.093", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-732" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-732" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-06-13 09:15
Modified
2024-11-21 08:01
Severity ?
4.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | q200_firmware | * | |
siemens | q200 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:q200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1D626C5-92BF-4C9B-9EF2-24347CF24491", "versionEndExcluding": "2.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:q200:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC2EA3F6-418C-49A4-B23C-E7BD56395466", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user." } ], "id": "CVE-2023-30901", "lastModified": "2024-11-21T08:01:02.097", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 1.4, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-06-13T09:15:17.763", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2023-30901 (GCVE-0-2023-30901)
Vulnerability from cvelistv5
Published
2023-06-13 08:17
Modified
2025-03-05 18:58
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF)
Summary
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens | POWER METER SICAM Q100 |
Version: All versions < V2.60 |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:37:15.518Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-30901", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-05T18:36:33.559072Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-05T18:58:01.759Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.60" } ] }, { "defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.60" } ] }, { "defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.60" } ] }, { "defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.60" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-352", "description": "CWE-352: Cross-Site Request Forgery (CSRF)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T09:59:13.439Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-30901", "datePublished": "2023-06-13T08:17:12.290Z", "dateReserved": "2023-04-20T12:49:03.482Z", "dateUpdated": "2025-03-05T18:58:01.759Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2023-31238 (GCVE-0-2023-31238)
Vulnerability from cvelistv5
Published
2023-06-13 08:17
Modified
2025-03-05 18:57
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Summary
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60), POWER METER SICAM Q100 (All versions < V2.60). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | Siemens | POWER METER SICAM Q100 |
Version: All versions < V2.60 |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:53:29.691Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-31238", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-05T18:36:30.697761Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-05T18:57:56.165Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.60" } ] }, { "defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.60" } ] }, { "defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.60" } ] }, { "defaultStatus": "unknown", "product": "POWER METER SICAM Q100", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.60" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60), POWER METER SICAM Q100 (All versions \u003c V2.60). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:C/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732: Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-01-09T09:59:42.265Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480095.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-31238", "datePublished": "2023-06-13T08:17:13.351Z", "dateReserved": "2023-04-26T17:03:00.579Z", "dateUpdated": "2025-03-05T18:57:56.165Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }