Vulnerabilites related to abb - relion_620_iec
CVE-2021-22283 (GCVE-0-2021-22283)
Vulnerability from cvelistv5
Published
2023-02-28 04:21
Modified
2025-03-07 18:12
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-665 - Improper Initialization
Summary
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.
References
Impacted products
Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
► | ABB | Relion protection relays - 611 series |
Version: 1.0.0 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T18:37:18.488Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2021-22283", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2025-03-07T18:11:58.860932Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2025-03-07T18:12:14.516Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Relion protection relays - 611 series", "vendor": "ABB", "versions": [ { "lessThan": "2.0.3", "status": "affected", "version": "1.0.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - 615 series IEC 4.0 FP1", "vendor": "ABB", "versions": [ { "lessThan": " 4.1.9", "status": "affected", "version": "4.1.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - 615 series CN 4.0 FP1", "vendor": "ABB", "versions": [ { "lessThan": "4.1.8", "status": "affected", "version": "4.1.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - 615 series IEC 5.0", "vendor": "ABB", "versions": [ { "lessThan": "5.0.12", "status": "affected", "version": "5.0.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - 615 series IEC 5.0 FP1", "vendor": "ABB", "versions": [ { "lessThan": "5.1.20", "status": "affected", "version": "5.1.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - 620 series IEC/CN 2.0", "vendor": "ABB", "versions": [ { "lessThan": "2.0.11", "status": "affected", "version": "2.0.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - 620 series IEC/CN 2.0 FP1", "vendor": "ABB", "versions": [ { "lessThan": "2.1.15", "status": "affected", "version": "2.1.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - REX640 PCL1", "vendor": "ABB", "versions": [ { "lessThan": "1.0.8", "status": "affected", "version": "1.0.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - REX640 PCL2", "vendor": "ABB", "versions": [ { "lessThan": "1.1.4", "status": "affected", "version": "1.1.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - REX640 PCL3", "vendor": "ABB", "versions": [ { "lessThan": "1.2.1", "status": "affected", "version": "1.2.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Relion protection relays - RER615", "vendor": "ABB", "versions": [ { "lessThan": "2.0.3", "status": "affected", "version": "2.0.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Remote Monitoring and Control - REC615", "vendor": "ABB", "versions": [ { "lessThan": "2.0.3", "status": "affected", "version": "1.0.0", "versionType": "firmware" } ] }, { "defaultStatus": "unaffected", "product": "Merging Unit- SMU615", "vendor": "ABB", "versions": [ { "lessThan": "1.0.2", "status": "affected", "version": "1.0.0", "versionType": "firmware" } ] } ], "datePublic": "2022-12-18T18:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.\u003cp\u003eThis issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.\u003c/p\u003e" } ], "value": "Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.\n\n" } ], "impacts": [ { "capecId": "CAPEC-216", "descriptions": [ { "lang": "en", "value": "CAPEC-216 Communication Channel Manipulation" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-665", "description": "CWE-665 Improper Initialization", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-28T04:21:41.776Z", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "references": [ { "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "source": { "discovery": "UNKNOWN" }, "title": "MMS File Transfer Vulnerability impact on Distribution Automation products", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2021-22283", "datePublished": "2023-02-28T04:21:41.776Z", "dateReserved": "2021-01-05T17:31:49.081Z", "dateUpdated": "2025-03-07T18:12:14.516Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2023-02-28 05:15
Modified
2024-11-21 05:49
Severity ?
6.2 (Medium) - CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Summary
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:smu615_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C01EB90B-8C81-4745-91C2-62747B185AE3", "versionEndExcluding": "1.0.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:smu615:-:*:*:*:*:*:*:*", "matchCriteriaId": "F24FC432-A799-44A1-9D7C-BF02203655C5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:rec615_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AEDB4A6F-2E61-4962-A3D5-350070435A3B", "versionEndExcluding": "2.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:rec615:-:*:*:*:*:*:*:*", "matchCriteriaId": "D5A61686-5740-48D4-AF7C-34F3323F4171", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:rer615_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DBD6846-1876-4EB7-B450-23689D08D05C", "versionEndExcluding": "2.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:rer615:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4FB1663-BA8D-4EDA-85D3-37FF05718FB7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:evd4_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D151411F-BBA1-4CC1-A898-7922CE9C734C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:evd4:-:*:*:*:*:*:*:*", "matchCriteriaId": "EEA5D2E2-AA96-4C81-8979-744778F19CC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:ref615r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5BB52A0A-144A-4701-A169-0DE203AF3733", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:ref615r:-:*:*:*:*:*:*:*", "matchCriteriaId": "9C1A2F33-73B8-488B-A88C-3546CA9FB51D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:rex640_pcl3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E3973E21-DF2C-47BB-8C03-6FA027018873", "versionEndExcluding": "1.2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:rex640_pcl3:-:*:*:*:*:*:*:*", "matchCriteriaId": "90916E18-27EF-46C7-979B-19D53F901CC7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:rex640_pcl2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FBE1B4D1-27C7-4EA9-ADA5-A7FE42E04FF6", "versionEndExcluding": "1.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:rex640_pcl2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE78102B-C672-4969-8B82-FE5ACE2FFC71", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:rex640_pcl1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AAA125ED-192D-4E4E-A4FC-FB7EF387FD90", "versionEndExcluding": "1.0.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:rex640_pcl1:-:*:*:*:*:*:*:*", "matchCriteriaId": "9256FAAB-77CF-482C-B736-FC99885C89D7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:rer620_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F8506D82-076A-4B42-AF41-CECE5B9F42A1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:rer620:-:*:*:*:*:*:*:*", "matchCriteriaId": "A0CDB660-57FB-4B12-B457-D32A20CB054D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:relion_611_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1D7EA08-4326-47EA-8045-135263708315", "versionEndExcluding": "2.0.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:relion_611:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D0BD760-FCEA-4620-A8D9-407C4670BDA0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:ref615_iec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B53D526E-2EE7-4D50-B6AE-43A2E5F51902", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:ref615_iec:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "9A52B165-B93A-4CD5-85F7-8DC085B8BF8D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:ref615_ansi_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6B0493F4-7619-4D98-9D15-069ECAF34EA2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:ref615_ansi:1.0:*:*:*:*:*:*:*", "matchCriteriaId": "27CE34F9-8441-4327-A7CF-BC9ED6C2838C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:ref615_iec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B53D526E-2EE7-4D50-B6AE-43A2E5F51902", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:ref615_iec:1.1:*:*:*:*:*:*:*", "matchCriteriaId": "5C694E31-330C-41B1-A080-278A1C3111A2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:red615_iec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1375F21-B685-4CC8-B781-73D68B07DC5B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:red615_iec:1.1:*:*:*:*:*:*:*", "matchCriteriaId": "B694B186-62A0-4235-97EB-EF4A9F02F185", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:ref615_ansi_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6B0493F4-7619-4D98-9D15-069ECAF34EA2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:ref615_ansi:1.1:*:*:*:*:*:*:*", "matchCriteriaId": "A250B053-1FD7-44F1-8622-C6FDFF4DE575", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:relion_615_iec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81982E5D-C2B7-40E5-B4B1-20E05558C183", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:relion_615_iec:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "E98E9975-0978-4632-9202-A036A2D66C7F", "vulnerable": false }, { "criteria": "cpe:2.3:h:abb:relion_615_iec:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "0954C681-0897-441F-AD78-2B1FBC6EC208", "vulnerable": false }, { "criteria": "cpe:2.3:h:abb:relion_615_iec:4.0:-:*:*:*:*:*:*", "matchCriteriaId": "D9C4BDD6-3EE7-4DC9-97C7-8F7F04DD80F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:relion_615_cn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "50CB9495-DBBC-4B36-AF67-6D5E1CD4CE76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:relion_615_cn:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "D2773068-653B-4F02-8CB8-5CA4CF7D6574", "vulnerable": false }, { "criteria": "cpe:2.3:h:abb:relion_615_cn:3.0:*:*:*:*:*:*:*", "matchCriteriaId": "66B405A7-E16B-48E0-AFC9-36A6AB21451D", "vulnerable": false }, { "criteria": "cpe:2.3:h:abb:relion_615_cn:3.1:*:*:*:*:*:*:*", "matchCriteriaId": "334CAC56-FBBC-45D4-9161-A53197CB30C2", "vulnerable": false }, { "criteria": "cpe:2.3:h:abb:relion_615_cn:4.0:-:*:*:*:*:*:*", "matchCriteriaId": "0B5B5511-A4EF-4814-BD67-F5A2F445B111", "vulnerable": false }, { "criteria": "cpe:2.3:h:abb:relion_615_cn:5.0:fp1:*:*:*:*:*:*", "matchCriteriaId": "431FDF0D-6734-40C0-AFA5-A5513B7324E6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:relion_615_ansi_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "78236AA2-3560-402B-B2FC-13070B805609", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:relion_615_ansi:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "591DB01E-3610-4AD2-A5F9-D8A061B597A5", "vulnerable": false }, { "criteria": "cpe:2.3:h:abb:relion_615_ansi:4.0:-:*:*:*:*:*:*", "matchCriteriaId": "63988EAE-73F9-4362-8B38-EDC3B1207F0F", "vulnerable": false }, { "criteria": "cpe:2.3:h:abb:relion_615_ansi:4.0:fp1:*:*:*:*:*:*", "matchCriteriaId": "05EF9495-C9B5-40C6-B648-C85B35373023", "vulnerable": false }, { "criteria": "cpe:2.3:h:abb:relion_615_ansi:4.0:fp2:*:*:*:*:*:*", "matchCriteriaId": "0208F75C-011B-4A15-AD1B-8DD1550B3077", "vulnerable": false }, { "criteria": "cpe:2.3:h:abb:relion_615_ansi:5.0:fp1:*:*:*:*:*:*", "matchCriteriaId": "8B25AD70-B3B4-45A7-B4B6-E072BA0A336A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:relion_615_iec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C79758CF-9F3B-4A79-A8D4-3D17D5D85497", "versionEndExcluding": "4.1.9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:relion_615_iec:4.0:fp1:*:*:*:*:*:*", "matchCriteriaId": "A6E38E09-2B98-4B3A-BFC0-391DE22ABDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:relion_615_cn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "79918D6E-7694-43B2-B474-649174A00054", "versionEndExcluding": "4.1.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:relion_615_cn:4.0:fp1:*:*:*:*:*:*", "matchCriteriaId": "412F7432-5049-4DB0-8009-6783A3821F1F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:relion_615_iec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3FE9A6FF-BBFD-48D6-B9D2-3AD244221C20", "versionEndExcluding": "5.0.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:relion_615_iec:5.0:-:*:*:*:*:*:*", "matchCriteriaId": "DE999A72-CEED-4235-B68F-590CF1128268", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:relion_615_iec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47DB1FAF-07D7-44FD-8368-BB29FF0DB4AD", "versionEndExcluding": "5.1.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:relion_615_iec:5.0:fp1:*:*:*:*:*:*", "matchCriteriaId": "50330FD9-AA32-439B-9E06-7228A7338F46", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:relion_620_iec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F5E4CADD-7849-40B5-9DC6-8B0571A5B16E", "versionEndExcluding": "2.0.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:relion_620_iec:2.0:-:*:*:*:*:*:*", "matchCriteriaId": "91122A2B-236D-4D36-93BD-93A6C2DB0263", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:relion_620_cn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C7230BC1-056F-4E13-AA11-8B19AC404B71", "versionEndExcluding": "2.0.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:relion_620_cn:2.0:-:*:*:*:*:*:*", "matchCriteriaId": "281A30D2-94DA-4D19-AAA7-30061BD94443", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:relion_620_ansi_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD99BDB2-6F9C-4141-AE1E-919764CD000A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:relion_620_ansi:-:*:*:*:*:*:*:*", "matchCriteriaId": "2A89CD0B-3990-47B0-9129-2BD5951F8C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:relion_620_iec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "315BBD9A-D5ED-4864-B12D-1C95515E7818", "versionEndExcluding": "2.1.15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:relion_620_iec:2.0:fp1:*:*:*:*:*:*", "matchCriteriaId": "CD43DF9B-4D26-4B59-BADA-F333D7E2815D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:abb:relion_620_cn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0BEA650E-EFD1-445D-8022-5C512E98B485", "versionEndExcluding": "2.1.15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:abb:relion_620_cn:2.0:fp1:*:*:*:*:*:*", "matchCriteriaId": "806460AF-BC4A-4584-8172-20092865AEEF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.\n\n" } ], "id": "CVE-2021-22283", "lastModified": "2024-11-21T05:49:50.640", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.5, "impactScore": 3.6, "source": "cybersecurity@ch.abb.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-02-28T05:15:12.260", "references": [ { "source": "cybersecurity@ch.abb.com", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA001147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "sourceIdentifier": "cybersecurity@ch.abb.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-665" } ], "source": "cybersecurity@ch.abb.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-665" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }