Summary
Login with hash: The login routine allows the client to log in to the system not by using the password, but by using the hash of the password. Combined with CVE-2021-23858, this allows an attacker to subsequently login to the system.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_l20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E75C9D7-9A6A-43D6-A260-9535673B87AA", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_l20:-:*:*:*:*:*:*:*", "matchCriteriaId": "B81F392D-9700-415D-A541-7D45035A2C67", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_l40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4E20554-1346-4F07-A277-38BBC2436E20", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_l40:-:*:*:*:*:*:*:*", "matchCriteriaId": "33698277-B03B-4D12-B4E2-F32E3BE8E786", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_l25_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72F2443A-5B3B-46F1-8ECF-93BA2E68D241", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_l25:-:*:*:*:*:*:*:*", "matchCriteriaId": "107BE5D1-062D-4D61-AB79-24D8C8FF3055", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_l45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "58B97235-37D0-45A7-8526-F9201D2E4021", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_l45:-:*:*:*:*:*:*:*", "matchCriteriaId": "30B3081C-5AB6-41B4-A53F-8C0B521DCE07", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_l65_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8C38E88B-69AA-47F5-B3DC-7F78461229BD", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_l65:-:*:*:*:*:*:*:*", "matchCriteriaId": "67F66AE1-9551-4E91-9476-D04B06245718", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_l75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52593B92-03AC-4972-B444-01E6384E3ECC", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_l75:-:*:*:*:*:*:*:*", "matchCriteriaId": "D0F46438-8E48-4AE8-92B4-6BA66A69BF60", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_l85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7455F0FF-89D9-4CDA-995E-BE2B64AAC241", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_l85:-:*:*:*:*:*:*:*", "matchCriteriaId": "1E637053-B9E4-4F91-88D9-FC4039445466", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_xm22_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "510A903A-B50D-4AB8-91CE-C18ABD7F8998", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_xm22:-:*:*:*:*:*:*:*", "matchCriteriaId": "49FF38C9-2239-4C88-B13B-448B6D38FA0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_xm21_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8420BD49-53E1-4467-9371-198967D0E56C", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_xm21:-:*:*:*:*:*:*:*", "matchCriteriaId": "13163AF4-8079-42D7-A68E-AF92E79D11A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_xm41_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "62D2DB9E-BC01-4FF2-B9E1-110E14EE3CA4", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_xm41:-:*:*:*:*:*:*:*", "matchCriteriaId": "B953972B-48C7-40A5-9A6C-6B876B0FF4D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_xm42_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "345732C4-1C46-472B-9C74-5BB399A459F4", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_xm42:-:*:*:*:*:*:*:*", "matchCriteriaId": "FFD5CE21-DB9C-4221-9C2D-A884622952D5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_xlc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BBDF65CA-43E0-4A26-B472-7AA0E97C6293", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_xlc:-:*:*:*:*:*:*:*", "matchCriteriaId": "19900CD6-4870-4F0C-BA1E-80F33C1DA287", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Login with hash: The login routine allows the client to log in to the system not by using the password, but by using the hash of the password. Combined with CVE-2021-23858, this allows an attacker to subsequently login to the system." }, { "lang": "es", "value": "Inicio de sesi\u00f3n con hash: La rutina de inicio de sesi\u00f3n permite al cliente iniciar la sesi\u00f3n en el sistema no por usar la contrase\u00f1a, sino al usar el hash de la contrase\u00f1a. Combinado con CVE-2021-23858, esto permite a un atacante iniciar posteriormente la sesi\u00f3n en el sistema" } ], "id": "CVE-2021-23857", "lastModified": "2024-11-21T05:51:57.673", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 6.0, "source": "psirt@bosch.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-10-04T18:15:07.797", "references": [ { "source": "psirt@bosch.com", "tags": [ "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/bosch-sa-741752.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/bosch-sa-741752.html" } ], "sourceIdentifier": "psirt@bosch.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-836" } ], "source": "psirt@bosch.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-10-04 18:15
Modified
2024-11-21 05:51
Severity ?
8.6 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
Information disclosure: The main configuration, including users and their hashed passwords, is exposed by an unprotected web server resource and can be accessed without authentication. Additionally, device details are exposed which include the serial number and the firmware version by another unprotected web server resource.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_l20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E75C9D7-9A6A-43D6-A260-9535673B87AA", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_l20:-:*:*:*:*:*:*:*", "matchCriteriaId": "B81F392D-9700-415D-A541-7D45035A2C67", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_l40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4E20554-1346-4F07-A277-38BBC2436E20", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_l40:-:*:*:*:*:*:*:*", "matchCriteriaId": "33698277-B03B-4D12-B4E2-F32E3BE8E786", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_l25_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72F2443A-5B3B-46F1-8ECF-93BA2E68D241", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_l25:-:*:*:*:*:*:*:*", "matchCriteriaId": "107BE5D1-062D-4D61-AB79-24D8C8FF3055", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_l45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "58B97235-37D0-45A7-8526-F9201D2E4021", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_l45:-:*:*:*:*:*:*:*", "matchCriteriaId": "30B3081C-5AB6-41B4-A53F-8C0B521DCE07", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_l65_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8C38E88B-69AA-47F5-B3DC-7F78461229BD", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_l65:-:*:*:*:*:*:*:*", "matchCriteriaId": "67F66AE1-9551-4E91-9476-D04B06245718", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_l85_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7455F0FF-89D9-4CDA-995E-BE2B64AAC241", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_l85:-:*:*:*:*:*:*:*", "matchCriteriaId": "1E637053-B9E4-4F91-88D9-FC4039445466", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_xm21_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8420BD49-53E1-4467-9371-198967D0E56C", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_xm21:-:*:*:*:*:*:*:*", "matchCriteriaId": "13163AF4-8079-42D7-A68E-AF92E79D11A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_xm22_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "510A903A-B50D-4AB8-91CE-C18ABD7F8998", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_xm22:-:*:*:*:*:*:*:*", "matchCriteriaId": "49FF38C9-2239-4C88-B13B-448B6D38FA0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_xm41_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "62D2DB9E-BC01-4FF2-B9E1-110E14EE3CA4", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_xm41:-:*:*:*:*:*:*:*", "matchCriteriaId": "B953972B-48C7-40A5-9A6C-6B876B0FF4D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_xm42_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "345732C4-1C46-472B-9C74-5BB399A459F4", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_xm42:-:*:*:*:*:*:*:*", "matchCriteriaId": "FFD5CE21-DB9C-4221-9C2D-A884622952D5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:indracontrol_xlc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "227FDBBE-EF02-4B57-BAE7-A06803AB1198", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:indracontrol_xlc:-:*:*:*:*:*:*:*", "matchCriteriaId": "A8C713B8-D965-46F8-A84D-EA61FFBB269D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:bosch:rexroth_indramotion_mlc_l75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52593B92-03AC-4972-B444-01E6384E3ECC", "versionEndIncluding": "12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:bosch:rexroth_indramotion_mlc_l75:-:*:*:*:*:*:*:*", "matchCriteriaId": "D0F46438-8E48-4AE8-92B4-6BA66A69BF60", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Information disclosure: The main configuration, including users and their hashed passwords, is exposed by an unprotected web server resource and can be accessed without authentication. Additionally, device details are exposed which include the serial number and the firmware version by another unprotected web server resource." }, { "lang": "es", "value": "Revelaci\u00f3n de informaci\u00f3n: La configuraci\u00f3n principal, incluyendo los usuarios y sus contrase\u00f1as con hash, est\u00e1 expuesta por un recurso del servidor web no protegido y puede ser accedido a ella sin autenticaci\u00f3n. Adicionalmente, los detalles del dispositivo est\u00e1n expuestos, incluyendo el n\u00famero de serie y la versi\u00f3n del firmware, por otro recurso de servidor web desprotegido" } ], "id": "CVE-2021-23858", "lastModified": "2024-11-21T05:51:57.813", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 7.8, "confidentialityImpact": "COMPLETE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 4.0, "source": "psirt@bosch.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-10-04T18:15:07.987", "references": [ { "source": "psirt@bosch.com", "tags": [ "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/bosch-sa-741752.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://psirt.bosch.com/security-advisories/bosch-sa-741752.html" } ], "sourceIdentifier": "psirt@bosch.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "psirt@bosch.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
CVE-2021-23858 (GCVE-0-2021-23858)
Vulnerability from cvelistv5
Published
2021-10-04 17:32
Modified
2024-08-03 19:14
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Summary
Information disclosure: The main configuration, including users and their hashed passwords, is exposed by an unprotected web server resource and can be accessed without authentication. Additionally, device details are exposed which include the serial number and the firmware version by another unprotected web server resource.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Rexroth | IndraMotion MLC L25, L45, L65, L75, L85, XM21, XM22, XM41 and XM42 IndraControl XLC |
Version: 12 VRS < unspecified |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T19:14:09.398Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://psirt.bosch.com/security-advisories/bosch-sa-741752.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "IndraMotion MLC L25, L45, L65, L75, L85, XM21, XM22, XM41 and XM42 IndraControl XLC", "vendor": "Rexroth", "versions": [ { "lessThan": "unspecified", "status": "affected", "version": "12 VRS", "versionType": "custom" } ] }, { "product": "IndraMotion MLC L20, L40", "vendor": "Rexroth", "versions": [ { "lessThan": "unspecified", "status": "affected", "version": "12 VRS", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "Information disclosure: The main configuration, including users and their hashed passwords, is exposed by an unprotected web server resource and can be accessed without authentication. Additionally, device details are exposed which include the serial number and the firmware version by another unprotected web server resource." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-04T17:32:22", "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c", "shortName": "bosch" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://psirt.bosch.com/security-advisories/bosch-sa-741752.html" } ], "source": { "advisory": "BOSCH-SA-741752 ", "discovery": "UNKNOWN" }, "title": "Information disclosure", "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@bosch.com", "ID": "CVE-2021-23858", "STATE": "PUBLIC", "TITLE": "Information disclosure" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "IndraMotion MLC L25, L45, L65, L75, L85, XM21, XM22, XM41 and XM42 IndraControl XLC", "version": { "version_data": [ { "version_affected": "\u003e=", "version_value": "12 VRS" } ] } }, { "product_name": "IndraMotion MLC L20, L40", "version": { "version_data": [ { "version_affected": "\u003e=", "version_value": "12 VRS" } ] } } ] }, "vendor_name": "Rexroth" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Information disclosure: The main configuration, including users and their hashed passwords, is exposed by an unprotected web server resource and can be accessed without authentication. Additionally, device details are exposed which include the serial number and the firmware version by another unprotected web server resource." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 8.6, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor" } ] } ] }, "references": { "reference_data": [ { "name": "https://psirt.bosch.com/security-advisories/bosch-sa-741752.html", "refsource": "CONFIRM", "url": "https://psirt.bosch.com/security-advisories/bosch-sa-741752.html" } ] }, "source": { "advisory": "BOSCH-SA-741752 ", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c", "assignerShortName": "bosch", "cveId": "CVE-2021-23858", "datePublished": "2021-10-04T17:32:22", "dateReserved": "2021-01-12T00:00:00", "dateUpdated": "2024-08-03T19:14:09.398Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
CVE-2021-23857 (GCVE-0-2021-23857)
Vulnerability from cvelistv5
Published
2021-10-04 17:32
Modified
2024-08-03 19:14
Severity ?
VLAI Severity ?
EPSS score ?
CWE
- CWE-836 - Use of Password Hash Instead of Password for Authentication
Summary
Login with hash: The login routine allows the client to log in to the system not by using the password, but by using the hash of the password. Combined with CVE-2021-23858, this allows an attacker to subsequently login to the system.
References
► | URL | Tags | |||
---|---|---|---|---|---|
|
Impacted products
Vendor | Product | Version | |||||||
---|---|---|---|---|---|---|---|---|---|
► | Rexroth | IndraMotion MLC L25, L45, L65, L75, L85, XM21, XM22, XM41 and XM42 IndraMotion XLC |
Version: 12 VRS < unspecified |
||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T19:14:09.701Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://psirt.bosch.com/security-advisories/bosch-sa-741752.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "IndraMotion MLC L25, L45, L65, L75, L85, XM21, XM22, XM41 and XM42 IndraMotion XLC", "vendor": "Rexroth", "versions": [ { "lessThan": "unspecified", "status": "affected", "version": "12 VRS", "versionType": "custom" } ] }, { "product": "IndraMotion MLC L20, L40", "vendor": "Rexroth", "versions": [ { "lessThan": "unspecified", "status": "affected", "version": "12 VRS", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "Login with hash: The login routine allows the client to log in to the system not by using the password, but by using the hash of the password. Combined with CVE-2021-23858, this allows an attacker to subsequently login to the system." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-836", "description": "CWE-836 Use of Password Hash Instead of Password for Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-04T17:32:36", "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c", "shortName": "bosch" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://psirt.bosch.com/security-advisories/bosch-sa-741752.html" } ], "source": { "advisory": "BOSCH-SA-741752 ", "discovery": "UNKNOWN" }, "title": "Login with hash", "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@bosch.com", "ID": "CVE-2021-23857", "STATE": "PUBLIC", "TITLE": "Login with hash" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "IndraMotion MLC L25, L45, L65, L75, L85, XM21, XM22, XM41 and XM42 IndraMotion XLC", "version": { "version_data": [ { "version_affected": "\u003e=", "version_value": "12 VRS" } ] } }, { "product_name": "IndraMotion MLC L20, L40", "version": { "version_data": [ { "version_affected": "\u003e=", "version_value": "12 VRS" } ] } } ] }, "vendor_name": "Rexroth" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Login with hash: The login routine allows the client to log in to the system not by using the password, but by using the hash of the password. Combined with CVE-2021-23858, this allows an attacker to subsequently login to the system." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-836 Use of Password Hash Instead of Password for Authentication" } ] } ] }, "references": { "reference_data": [ { "name": "https://psirt.bosch.com/security-advisories/bosch-sa-741752.html", "refsource": "CONFIRM", "url": "https://psirt.bosch.com/security-advisories/bosch-sa-741752.html" } ] }, "source": { "advisory": "BOSCH-SA-741752 ", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c", "assignerShortName": "bosch", "cveId": "CVE-2021-23857", "datePublished": "2021-10-04T17:32:36", "dateReserved": "2021-01-12T00:00:00", "dateUpdated": "2024-08-03T19:14:09.701Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }